Search NASA⌕ Search

SEARCH · Search NASA

Results for “battery fire”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

82 records · Page 5

Could on-site fuel storage economically reduce power plant-gas grid dependence in pipeline constrained areas like New England?

In the Northeastern United States, natural gas supply constraints have led to periods when gas shortages have caused up to a quarter of all unscheduled power plant outages. Dual fuel oil/gas generators or local gas storage might mitigate gas supply shortages. We use historical power plant operational and availability data to develop a supply curve of the costs required for generators to mitigate fuel shortage failures in New England. Based on 2012–2018 data, we find that the historical fuel shortages at approximately 2 GW worth of gas-fired capacity could be mitigated using on-site fuel storage. For comparison, New England’s average reserve margin was 1.7–2.8 GW over our sample period. Oil dual fuel plants would recoup their investment if compensated with a reliability adder of $\$ 3-7$/MWh during their normal operations, while $\$ 7-16$/MWh would incentivize using onsite, compressed natural gas storage. We estimate that the capital expenses associated with the fuel storage options would be less expensive than installing battery backup for resource adequacy at current battery prices.

03 NATURAL GAS↗

Calculating Behind-the-Meter Energy Storage Incentives on an Avoided Cost Basis

Behind-the-meter (BTM) energy storage offers the potential for shared investment by utilities and their customers, in which both parties share in the costs and benefits of battery investment. Several utilities and a handful of states have begun providing incentives to help customers purchase BTM energy storage, and in exchange, operate that battery on behalf of the customer to realize grid benefits such as meeting peak capacity needs. But there is wide variation in the value and structure of these incentives, suggesting a lack of clarity on the value of BTM storage to the grid and to non-participating customers who fund the incentives for participating customers. This paper provides an objective framework for establishing BTM energy storage incentives based on the avoided cost of generation from a marginal, gas-fired peaking plant. It also conducts several sensitivity analyses to see how those avoided costs vary with emissions pricing, gas prices, plant heat rates, and utility capital structures. This work may be of use to utilities, regulators, and energy system stakeholders in providing a value-based framework for BTM incentive programs that can be used in the absence of policy guidance.

Twitchell, Jeremy B.↗

Incident Energy Systems Model: User Guide and Examples

U.S. Forest Service (USFS) wildfire base camps use portable power for electrical needs, including yurts and trailers from which logistics staff work during the incident. These yurts and trailers are conventionally powered by portable diesel generators. Hybrid portable power systems consisting of a combination of solar photovoltaics (PV), battery energy storage systems (BESS), and/or backup diesel generators have been used in recent years and were piloted by the National Technology and Development Program (NTDP) on incidents in fall 2024 as part of NTDP's Portable Power Project. As part of that project, this work included the development of two Excel-based tools and two reports explaining the tools. The first tool, the Incident Energy Systems Model, is an Excel-based tool that models the power output of hybrid portable power systems powering yurts and/or trailers at fire camps over a typical day.

14 SOLAR ENERGY↗

GEMINI Case Study

Sandia's GEMINI-Scout Mine Rescue Robot is an unmanned ground vehicle designed to enter potentially hazardous environments to explore, assess, and evaluate dangerous situations first responders may face when conducting a rescue mission. GEMINI is approximately four feet long and two feet tall, which enables the robot to maneuver through small locations on rough terrains caused by earthquakes, fires, or radiological incidents. GEMINI uses track propulsion to climb stairs, travel through gravel and sand pits, pivot in place, and traverse 45-degree climbs with few problems. Furthermore, the vehicle's dual tracked-chassis design allows it to operate in hostile, dark, muddy, high-temperature, and explosive debris-strewn environments, while maintaining efficient ground mobility. The mobility and modularity of the vehicle allow for easy integration of sensors to conduct gas and temperature sensing and offers pan/tilt, zoom color, and thermal camera video streaming capabilities. The vehicle is also able to carry a payload of about 50 pounds of batteries and can handle an additional 200 pounds of payload, whether for additional diagnostics, supplies, or clothing for those trapped in an effected area. GEMINI is remotely operated through a wireless connection and an onboard computer running a customized embedded control application, which directly communicates to all onboard components except for the audio and video systems. When line of sight is not possible, operators use a shockresistant fiber optic cable to ensure continuous functionality of the vehicle. This allows for direct local control of the vehicle, which streams collected data back to the operator for enhanced situational awareness. In addition, the vehicle incorporates safety features such as explosion proof housing to ensure safe electronic operations in hazardous gas or flooded environments; a four-channel video link and two-way audio to ensure located survivors can communicate with operators; and an MSHA-approved multi-gas sensor to monitor air quality.

42 ENGINEERING↗

Overcharge-to-thermal-runaway behavior and safety assessment of commercial lithium-ion cells with different cathode materials: A comparison study

In this paper, overcharge behaviors and thermal runaway (TR) features of large format lithium-ion (Li-ion) cells with different cathode materials (LiFePO 4 (LFP), Li[Ni 1/3 Co 1/3 Mn 1/3 ]O 2 (NCM111), Li[Ni 0.6 Co 0.2 Mn 0.2 ]O 2 (NCM622) and Li[Ni 0.8 Co 0.1 Mn 0.1 ]O 2 (NCM811)) were investigated. The results showed that, under the same overcharge condition, the TR of LFP Li-ion cell occurred earlier compared with the NCM Li-ion cells, indicating its poor overcharge tolerance and high TR risk. However, when TR occurred, LFP Li-ion cell exhibited lower maximum temperature and mild TR response. All NCM Li-ion cells caught fire or exploded during TR, while the LFP Li-ion cell only released a large amount of smoke without fire. According to the overcharge behaviors and TR features, a safety assessment score system was proposed to evaluate the safety of the cells. In short, NCM Li-ion cells have better performance in energy density and overcharge tolerance (or low TR risk), while LFP Li-ion cell showed less severe response to overcharging (or less TR hazards). For NCM Li-ion cells, as the ratio of nickel in cathode material increases, the thermal stability of the cathode materials becomes poorer, and the TR hazards increase. Such a comparison study on large format Li-ion cells with different cathode materials can provide deeper insights into the overcharge behaviors and TR features, and provide guidance for engineers to reasonably choose battery materials in automotive applications.

25 ENERGY STORAGE↗

Grid Resilient, Self-Powered, Fuel Flexible, High Efficiency Heating System (Final Report)

The Grid Independent High Efficiency System (GIHES) delivers a heating system that operates free from the power grid and provides ultra-low emissions and high efficiency heating for residential and commercial buildings. The project demonstrated two weeks of continuous grid independent operation of a storage water heater equipped with a powered damper. The Thermoelectric Generator (TEG) integrated GIHES technology revolutionizes heating systems to provide grid resilient hot water production, while delivering significant value to the end user by eliminating impacts of power interruption and enhancing comfort, convenience and productivity. The system maximizes the thermal-to-electric conversion efficiency by optimizing location and orientation of the TEGs and durability while lowering system costs. The TEGs generate enough power to charge a battery and run the storage water heater unit with a powered damper uninterrupted by providing the required parasitic electrical power for start-up, shutdown and during idling. Several TEGs were analytically and experimentally evaluated based on the size, surface area and the power being generated before designing and fabricating a complete multi-TEG assembly for integration with the water heater. The GIHES technology can be extended to boilers, furnaces and tankless water heaters and integrated with heat pump to further increase the overall equipment efficiency. The technology has the potential to reduce the amount of dispatch power and peak power plant operation. An advanced burner was designed, developed and 3D printed for fuel flexible operation. The burner was designed to enable tighter integration with TEGs for potentially higher TEG output, should this be necessary. A bench-scale test rig to perform testing of a 200,000 Btu/h burner and capable of handling up to 10% H2 (by volume) was setup at GTI’s laboratory with appropriate safety and controls to ensure smooth and safe operation. Testing of the 3D burner showed < 5 ppm NOx emissions can be achieved for the entire firing range and with different levels of hydrogen blends with natural gas. The burner will enable a more integrated TEG-burner module design for improved system performance, should this be required in the future. Techno-economic analysis (TEA) of the TEG integrated with the water heaters was performed. The testing data and the power output were used to develop the TEA. The analysis for the storage unit with damper showed that the TEG integrated system costs $95. This is much lower than a one-time charge needed to wire and install dedicated power. Discussions with TEG manufacturers and OEM’s will provide more detailed information and methods to further lower these costs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Integration of Superconducting Magnetic Energy Storage (SMES) Systems Optimized with Second-Generation, High-Temperature Superconducting (2G-HTS) Technology with a Major Fossil-Fueled Asset

Utility companies and fossil fueled generation assets are seeking combinations of “hybrid energy storage” to allow power to be provided in advance of, and to otherwise complement, peaking natural gas-fired generation. American Maglev Technology of Florida Inc. (AMT) learned during the Phase I program based on interactions with NRG Energy (NRG) that energy storage such as superconducting magnetic energy storage (SMES) can qualify as a Black Start unit in most markets, ensuring orderly re-start of grid operations and fossil fueled power plants and serving as an important asset of hybrid energy storage technology. In conjunction with the University of Houston (UH), AMT and NRG are working together to scale up low-cost, high- efficiency, second-generation high-temperature superconducting (2G-HTS) technology for deployment across several markets, with a primary focus on the commercial development of utility grid-scale SMES (g-SMES) systems. Ultimately the program confirmed that the novel g-SMES design can meet the performance and financial requirements of the fossil power plant industry, while exhibiting continuous grid-voltage regulation; cost-effective, peak-hour energy storage with almost infinite life; increased input/output efficiency; and the capability to undergo millions of charging cycles, without degradation, representing a significant improvement over lithium ion and other conventional storage technologies. We believe wide scale deployment of this technology is feasible and practical when compared to the higher life cycle cost and relatively short lifespan of chemical batteries. Based on these findings, the future for deployment of SMES at many fossil-fueled power plants exceeding 100MW capability is bright. Further de-risking g-SMES technology would pave the way for the construction of a subscale prototype. Eventually, scaled-down versions of SMES are expected to be competitive with the multi-billion-dollar lithium-ion market for a wide range of commercial, industrial, and transportation uses. There is long-term potential for commercialization and widespread deployment of this disruptive technology, which would spawn a new worldwide supply chain and create domestic, high-tech manufacturing jobs in the green industry.

20 FOSSIL-FUELED POWER PLANTS↗

Retrofitting Holcim Ste. Genevieve Cement Plant with CO2 Capture Plant Using Air Liquide Cryocap™ FG Technology

The global cement manufacturing industry is a major contributor to carbon dioxide emissions. The International Energy Agency's "Net Zero Emissions by 2050 Scenario" identifies CCS as a major strategy for meeting that goal. This project is among the first attempts to transfer capture technology developed at coal-fired power plants to the cement industry. The main objective of the project is to execute and complete a front-end engineering and design (FEED) studies for commercial-scale, carbon capture projects that separates 95% of the total CO2 emissions at the Holcim (US) Ste. Genevieve cement manufacturing facility using Air Liquide’s Pressure Swing Adsorption system (PSA) assisted Cryocap™ technology. The Holcim Ste. Genevieve cement plant in Missouri, US, boasts one of the largest single cement production lines in the world, with a capacity of approximately 12,000 t/day. The plant currently uses traditional fuels, namely coal and petcoke. The captured CO2 will be pipeline and geological storage grade. The industrial host site emits approximately 3.0 million tonne CO2/yr. Air Liquide’s Cryocap™ technology has been developed over the last 18+ years for CO2 capture applications. It has been shown to be applicable to a variety of industrial applications (e.g., steel, cement, SMR, Fluidized Catalytic Crackers (FCCs)). Cryocap™ FG consists of a Pressure Swing Adsorption (PSA) unit coupled with a Cryogenic System. The PSA pre-concentrates the CO2 from the flue gas, while the cryogenic unit enables the CO2 purity to be increased to the desired level. The project team is led by the Prairie Research Institute at the University of Illinois at Urbana-Champaign. The tasks include: complete FEED study for retrofitting the industrial facility with a carbon capture system to support developing a detailed cost estimate; business case analysis outlining the anticipated revenue and credits if projects was built and operated; technoeconomic analysis (TEA) outlining how capture system achieves DOE capture goals; and life cycle (LCA) analysis demonstrating zero net carbon emissions. The FEED study was successfully completed. This includes completing the process basis of design; preliminary engineering; outside battery limits (OSBL) detailed engineering including a Zero Liquid Discharge (ZLD) wastewater treatment system; inside battery limits (ISBL) detailed engineering [1]. An overall project capital cost estimate within a -20%/+30% accuracy was developed. The major contributors to the Total Plant Cost (TPC), by system, are the costs associated with the Outside Battery Limit (OSBL) section of the plant which includes a new river water intake structure and a Zero Liquid Discharge (ZLD) system. By cost category, the major contributors to the TPC are equipment and subcontractor costs, followed closely by engineering, construction management, home office and contractor fees. The TEA has been created to reflect the findings of the project. It analyzes the economic performance of the Cryocap™ technology by reviewing the estimated capital costs, operating cost, and revenue. The Cost of Capture (COC) associated with the Cryocap™ technology for 95% CO2 capture, when considering NETL 2018 economic assumptions (42/58 debt/equity ratio, 5.15% interest on debt and 1.42% return on equity in real dollars) and 2022 economic assumptions (42/58 debt/equity ratio, 8.82% interest on debt and 4.90% return on equity in real dollars) was found to be much lower than that for the DOE-NETL’s base-line cases. The highest contributors to the COC are annualized capital expenditures (CAPEX) and electricity consumption which can be offset by using lower cost renewable sources. The LCA was conducted using OpenLCA which is an open-source software that is recommended by NETL. The database utilized for this study was a modified version of TRACI 2.1 (developed by the US. Environmental Protection Agency’s National Risk Management Research Laboratory and modified by NETL). The Cryocap™ FG technology does not consume fuels in significant quantities and does not utilize specialized chemical solvents subject to decomposition, such as those utilized in amine-based carbon capture systems. The Cryocap™ FG technology mainly utilizes electricity as its energy input; hence, its calculated emissions are mainly associated with the generation of electricity offsite and are dependent on the energy matrix of the grid at the time of project implementation. The water consumption impact of the Cryocap™ FG is mostly for makeup of the water lost by evaporation in the cooling tower; however, the carbon capture plant will be equipped with a ZLD system to avoid effluent streams and minimize water consumption. The successful construction and operation of this plant based on this study results will provide a means to demonstrate an economically attractive and transformational capture technology that can be used to retrofit existing plants and be deployed at new plants.

01 COAL, LIGNITE, AND PEAT↗

Investigation of powertrain system decarbonization using electrically assisted turbocharging and hybridization in off-road vehicles

In recent years, the causes, effects, and existential threat of a global anthropogenic climate shift have drawn significant attention and stimulated mitigation efforts from all genres of scientific, political, and industrial bodies. The greenhouse effect and the detrimental environmental impact of excess greenhouse gas (GHG) emissions, like carbon dioxide, is well studied and targeted as the primary culprit for aversive action. However, some fields exist where reducing GHG emissions is met by considerable challenges. One such field is the production and operations of off-road vehicles. Applications of these vehicles are highly diverse and are often characterized by rugged, especially transient, and power intensive duty cycles that make one-fits-all vehicle configuration solutions impractical. This research surveys existing literature to identify the modern technologies packages and challenges that face development and configuration of powertrain systems which currently navigate the regulated emissions and unique duty cycle requirements of this market space. A novel powertrain concept is proposed and evaluated with respect to the pinnacle objectives of load performance improvement, criteria pollutant reduction, and reducing the life cycle GHG intensity of its operation. A sure-fire path to vehicular GHG reduction is through improving the fuel efficiency of internal combustion engines (ICEs), an entrenched component of the off-road vehicle sector. Unfortunately, this is more easily said than done. An approach that has proven successful in this endeavor is engine downsizing and turbocharging, where a larger engine is replaced with a smaller one with added air system boosting via turbocharger to reduce frictional and pumping losses while also enabling access to additional fuel energy. However, practical realization of these potential benefits is often impeded by the transient response capability of the smaller engine across the operating space. For this reason, downsized ICE powertrains have turned to electrified forced induction systems (EFISs) for a decoupling of exhaust energy and engine speed from boost capability. Platformed on 48V hybrid technology, these systems introduce the need for more sophisticated controls around the engine gas-exchange process for the management of boost performance and exhaust gas emissions. On this account, simulation studies utilizing a GT-POWER model of a turbocharged 4.5 L engine outfit with an EFIS using an electrically driven compressor (eBooster®) are conducted to provide insight into the performance of this air handling architecture on an off-road engine. The results show that improvement in transient torque response time in sync with reduction in engine-out soot and NOx emissions are possible with an engine recalibration that leverages the transient air-fuel ratio authority of the eBooster®. Benefits are further demonstrated when duty cycle simulations of the 48V mild-hybrid engine concept are exercised, showing an acute decrease in cumulative fuel usage and soot production. Powertrain hybridization is another technological pathway achieving pronounced GHG reduction successes in modern on-road vehicle applications through integration of Li-ion battery technology. In the off-road vehicle segment, a review of available literature concludes that hybridized architectures are present but generally lack the depth of technologies that have both high specific energy and power capabilities, and thus are limited in their inclusion of Li-ion batteries for ICE assistance and enhanced energy storage capability. Therefore, building on the mild-hybrid engine results, the downsized and eBoosted engine concept was integrated into a larger high-voltage battery-hybrid series-electric powertrain system. Hybrid powertrain parameter sensitivity studies were carried out in a numerical charge-sustaining framework, providing novel insights into power flows between the battery and the engine and how their respective capabilities and operation contribute to GHG and criteria pollutant emissions of diverse duty cycles. Application of supervisory power management introduced robustness into the power sourcing and battery SOC control process and showed that optimum specification of battery properties can yield synergies between GHG emissions and battery energy capacity. Furthermore, examination of recent literature on Li-ion batteries has shown that pack manufacturing is a highly energy intensive process, thereby producing considerable quantities of GHGs that scale with energy storage capacity. Also scaling with a battery’s energy storage capacity is its investment cost. In consideration of these factors, an inclusive technoeconomic and GHG life cycle analysis is conducted. This analysis systematically compares the carbon footprint and total cost of ownership associated with the proposed hybrid powertrain concept to reference and alternative powertrain configurations, facilitating a thorough evaluation of the decarbonization effectiveness and economic viability.

99 GENERAL AND MISCELLANEOUS↗

Repurposing Fossil-Fueled Assets For Energy Storage

The annual retirement of U.S. coal-fired electricity generation units (CF-EGU) is at an all-time high and is expected to continue. This loss of reliable baseload generation, combined with predicted growth of variable renewable energy (VRE) generation, is expected to stress grid reliability as the number of load-following resources drops below the experienced load variability. Many regions are already experiencing challenges, and fossil retirement-related warnings by the North American Electric Reliability Corp. are becoming more dire. All CF-EGU retirements pose significant challenges to asset owners, local workforces, and their communities. Repurposing a retiring CF-EGU as a long-duration energy storage plant can address these challenges and offer a suite of additional benefits to asset owners, the grid, and society. This project performed a techno-economic evaluation and assessment of repurposing a Duke Energy fossil-fueled asset (in particular, a coal plant) into an energy storage system by integrating the retiring asset with a Malta long duration Pumped Heat Energy Storage (PHES) system. The project validated the technoeconomic benefits of repurposing retiring coal plants into long-duration energy storage using Malta’s PHES. Key findings for this project are summarized below: (1) Technical: (a) Retiring coal plants (and other steam turbine fossil generation) can be repurposed to enable the clean energy transition using Malta’s technology. (b) For older retiring coal plants, repurposing the site and electrical interconnection for a standalone PHES plant is the most economically favorable option. (c) For newer coal plants where there is also a local peaking capacity need, repowering the steam cycle into a hybrid integration with PHES is attractive. (d) A process was developed to assist fossil generation owners in choosing the best path for each plant’s circumstances. (2) Economic (a) Communities facing economic challenges caused by the retirement of fossil generation would benefit from repurposing the plant as long-duration energy storage using Malta’s PHES. (b) On a $/MW basis, repowering retiring coal units into Malta PHES plants can maintain the same number and types of jobs and economic activity. (c) For a 70% carbon reduction scenario, a 10-hour Malta PHES plant is more economic for the asset owner than similar-power 4-hour batteries. This project showed that repurposing a retiring coal unit into thermal energy storage, by integrating it with a Malta PHES system, makes techno-economic sense. At least two integration options are available, with the optimal solution depending on the coal plant and its location. Repurposing retiring coal plant into energy storage results in economic benefits for the plant owner and local communities.

20 FOSSIL-FUELED POWER PLANTS↗