At least 91 records · Page 5

A review of thermal physics and management inside lithium-ion batteries for high energy density and fast charging

Traditionally it has been assumed that battery thermal management systems should be designed to maintain the battery temperature around room temperature. That is not always true as lithium-ion battery (LIB) R&D is pivoting towards the development of high energy density and fast charging batteries. Therefore, it is necessary to have a comprehensive review of thermal considerations for LIBs targeted for high energy density and fast charging, i.e., the optimal thermal condition, thermal physics (heat transport and generation) inside the battery, and thermal management strategies. As the energy density and charge rate increases, the optimal battery temperature can shift to be higher than room temperature. In the first part of the review various sources of heat generation inside LIBs and various approaches to minimizing battery heat generation are summarized. The importance of heat of mixing due to ion diffusion during fast charging is also highlighted. To improve the temperature uniformity and avoid excessive internal temperature rise, heat transfer inside the battery needs to be enhanced, and reducing the thermal contact resistance between the electrodes and separator can significantly increase the effective thermal conductivity of batteries. In the second part of the review various challenges and latest developments related to thermal transport and properties of LIBs are discussed. Finally, a summary of latest advancement on smart control of internal temperature of LIBs is discussed as depending on the ambient temperature and the optimal temperature; the battery heat needs to be retained or dissipated to elevate or avoid temperature rise.

25 ENERGY STORAGE↗

Effect of thermal environments on fast charging Li-ion batteries

Battery thermal management systems (BTMSs) are expected to keep the battery temperature at a moderate level (~30 °C) to minimize the thermally exacerbated degradation. However, during fast charging, a strong cooling system is required to restrict the temperature rise of Li-ion batteries (LiBs), which significantly increases the cost and weight of battery packs, and induces a large temperature variation inside the battery. Here, in this work, we find that all these drawbacks could be relieved by allowing LiBs to charge at higher temperatures. Since the fast charging of a LiB only takes a tiny fraction of its lifetime, the aging rate is limited even at a charging temperature of 60 °C. Three types of thermal environments are proposed: kept constant at 30 °C, preheated to 60 °C, and adiabatic fast charging. With an experimentally validated electrochemical-thermal (ECT) coupled model, we explore the interplay between thermal management and the fast-charging performance. It is found that a gradually increasing temperature profile is the best option to balance the lithium plating and thermal management of the battery. Combining adiabatic fast charging with a preheating step, we can achieve minimal cooling need, perfect temperature uniformity within a battery, and fast-charging capability simultaneously.

25 ENERGY STORAGE↗

Thermal regulation of batteries

A battery thermal management system for an air vehicle includes a liquid heat exchange circuit. The system includes at least one battery in thermal communication with the liquid heat exchange circuit. The system includes a controller operatively connected to the liquid heat exchange circuit. The controller is configured and adapted to variably select whether heat will be rejected to the liquid heat exchange circuit. The system includes at least one heat exchanger positioned on the liquid heat exchange circuit. The at least one heat exchanger is a liquid-air heat exchanger or a liquid-liquid heat exchanger. A method for controlling a thermal management system for an air vehicle includes determining an expected temperature of at least one battery, and cooling the at least one battery with a cooling device if the expected temperature exceeds a pre-determined expected temperature threshold.

Rheaume, Jonathan↗

A Novel Modular, Reconfigurable Battery Energy Storage System: Design, Control, and Experimentation

This paper presents a novel modular, reconfigurable battery energy storage system. The proposed design is characterized by a tight integration of reconfigurable power switches and DC/DC converters. This characteristic enables isolation of faulty cells from the system and allows fine power control for individual cells toward optimal system-level performance. An optimal power management approach is developed to extensively exploit the merits of the proposed design. Based on receding-horizon convex optimization, this approach aims to minimize the total power losses in charging/discharging while allocating the power in line with each cell’s condition to achieve state of-charge (SoC) and temperature balancing. By appropriate design, the approach manages to regulate the power of a cell across its full SoC range and guarantee the feasibility of the optimization problem. Here, we perform extensive simulations and further develop a lab-scale prototype to validate the proposed system design and power management approach.

25 ENERGY STORAGE↗

Advanced diagnostics to evaluate heterogeneity in lithium-ion battery modules

Battery packs for electric and stationary applications experience varied operating conditions, including abuse—e.g., fast charging, overcharging, thermal, vibration, shock, etc.—throughout their lifetimes. Innovative diagnostic tools and algorithms that go beyond single cells and deal with modules and packs are essential for early detection of off-normal issues. High-resolution tools with known detection limits are key to developing appropriate mitigation strategies. With the advent of rapid impedance spectroscopy that can generate a broadband impedance spectrum in ~10 sec, the case for impedance-based diagnostics that can be readily aligned with other methods, such as incremental capacity or dQ.dV -1 , has become promising. This study used the aforementioned diagnostic methods to identify realistic in-vehicle battery abnormalities (e.g., localized self-discharge and non-uniform aging), in series (up to 10S) and parallel (4P) strings, using 16 Ah graphite/NMC cells. The impedance-based diagnostic is found to be sensitive to the string size and state. Depending on the type of abnormality, detection frequency varied. The dQ.dV -1 method showed the potential to detect long-term aging-related heterogeneity in modules. In general, both the impedance and dQ.dV -1 methods were able to detect series strings’ abnormalities, but struggled to find those issues within parallel modules.

25 ENERGY STORAGE↗

Catalyzing deep decarbonization with federated battery diagnosis and prognosis for better data management in energy storage systems

Industrial data analytics methods play a central role in improving energy storage performance and efficiency, impacting the future of electrified transportation and renewable electricity generation. However, significant challenges hinder the large-scale deployment of batteries. Conventional methods rely on centralized collection and processing of fleet-level data, leading to database size issues and privacy concerns due to potential data breaches. To enable scalable deployment of battery management systems, this article proposes a federated battery diagnosis and prognosis model, which distributes the processing of battery standard current-voltage-time-usage data in a privacy-preserving manner. Instead of transferring the raw data, this approach communicates only the locally processed parameters, thus reducing communication load and preserving data confidentiality. The federated model offers a paradigm shift in battery health management through privacy-preserving distributed methods for battery data processing and lifetime prediction, ensuring the reliable and sustainable deployment of lithium-ion batteries in a rapidly evolving world.

asset health management↗

Thermal regulation of batteries

A battery thermal management system for an air vehicle includes a first heat exchange circuit, a battery in thermal communication with the first heat exchange circuit, and a heat exchanger positioned on the first heat exchange circuit. The heat exchanger is operatively connected to a second heat exchange circuit. The system includes a controller operatively connected to the second heat exchange circuit. The controller is configured to variably select whether heat will be rejected to the second heat exchange circuit. A method for controlling a thermal management system for an air vehicle includes determining an expected fluid temperature of fluid in a fluid heat exchange circuit. The method includes commanding a flow restrictor at least partially closed or commanding the flow restrictor at least partially open.

Macdonald, Malcolm↗

A Path to 100 Percent Renewable Energy: Grid-Forming Inverters will Give Us the Grid We Need Now

This is a more urgent problem than it might sound. The westernmost Hawaiian island of significant size, Kauai is home to around 70,000 residents and 30,000 tourists at any given time. Renewable energy accounts for 70 percent of the energy produced in a typical year - a proportion that's among the highest in the world and that can be hard to sustain for such a small and isolated grid. During the day, the local system operator, the Kauai Island Utility Cooperative, sometimes reaches levels of 90 percent from solar alone. But on 2 April, the 26-MW generator was running near its peak output, to compensate for the drop in solar output as the sun set. At the moment when it failed, that single generator had been supplying 60 percent of the load for the entire island, with the rest being met by a mix of smaller generators and several utility-scale solar-and-battery systems.

battery management systems↗

Heat Generation Concerns Associated with Extreme Fast Charging

Present-day thermal management systems for battery electric vehicles are inadequate in limiting the maximum temperature rise of the battery during extreme fast charging. Incorrect thermal management designs for extreme fast charging conditions could result in cells reaching abuse temperatures and potentially sending the cells into thermal runaway. Furthermore, the cell and module design needs to be improved to meet the lifetime expectations of the consumer. Each of these aspects is explored and addressed as well as outlining where the heat is generated in a cell, the efficiencies of power and energy cells, and how to potentially measure the internal temperatures of a battery. Thermal management is not a limiting condition with regards to extreme fast charging, but many factors need to be addressed especially for future high specific energy density cells to meet U.S. Department of Energy cost and volume goals.

ADVANCED PROPULSION SYSTEMS↗

White Paper on Case Study of Safe Installation of Second-Life Energy Storage System

This technical report provides for a case study for the safe installation of a second-life, or repurposed, battery, that has been reconfigured for use as a stationary energy storage systems (ESS). Driven by legislative requirements such as California Senate Bill 615 and projections that retired EV batteries could meet a substantial portion of U.S. grid ESS needs beginning in 2035, the repurposing of EV batteries is anticipated to grow significantly. However, safety concerns arise from the effects of aging, unknown prior usage history, and changes in thermal runaway behavior, which may increase failure risks compared to new batteries. NFPA 855, the predominant U.S. standard for ESS installation, mandates that second-life batteries meet all requirements for new batteries, with repurposers complying with UL 1974 in addition to obtaining UL 9540 and UL 1973 listings. These are certifications that few repurposers have achieved and represent a regulatory barrier to entry for the market as a whole.

47 OTHER INSTRUMENTATION↗

Design and Performance of lithium-Ion Batteries for Achieving Electric Vehicle Takeoff, Flight, and Landing

Today, the burgeoning drive towards global urbanization with over half the earth’s population living in cities, has created major challenges with regards to intracity and intercity transit and mobility. This problem is compounded due to the fact that almost always urbanization and increase in standard of living drives individual automobile ownerships. Over 95% of automobiles are presently powered by some form of fossil fuel and as an unintended consequence, urban centers have also been centers for peak greenhouse gas emissions, a major contributor to global climate change. A revolutionary solution to this conundrum is flight capable electric automobiles or electric aerial vehicles that can tackle both urban mobility and climate change challenges. For such advanced electric platforms, energy storage and delivery component is the vital component towards achieving takeoff, flight, cruise, and landing. The requirements and duty cycle demands on the energy storage system is drastically different when compared to the performance metrics required for terrestrial electric vehicles. As the widely deployed lithium ion-based battery systems are often the primary go-to energy storage choice in electric vehicle related applications, it is imperative that performance metrics and specifications for such batteries towards areal electric vehicles need to be established. In this nascent field, there exists ample opportunities for battery material innovations, understanding degradation mechanism, battery design, development and deployment of battery control and management systems. Thus, this chapter comprehensively discusses battery requirements and identifies battery material chemistries suitable for handling aerial electric automobile duty cycles. The chapter also discusses the battery cell-level metrics pertaining to electrochemical, chemical, mechanical, and structural parameters. Furthermore, specific models for battery degradation, state of health (SOH), capacity and models for full cell performance and degradation are also discussed here. Finally, the chapter also discusses battery safety and future directions of batteries that would power these next generation urban electric aircrafts.

Amin, Ruhul↗

LuSEE-night power distribution system design

The Lunar Surface Electromagnetic Experiment at Night (LuSEE-Night) is a low-frequency, 0.5 to 50 MHz, radio experiment on the radio-quiet far side of the Moon. The instrument will be launched by NASA Commercial Lunar Payload Services in 2026. The LuSEE-Night instrument core is composed of a radio frequency spectrometer (SPT) processing signals from four antennas, the Data Controller Board (DCB), low electromagnetic interference (EMI) Picket Fence Power Supply (PFPS), and Power Distribution Unit (PDU). The battery powers the instrument during the lunar night and stores energy harvested by the solar panel array during the lunar day. The battery charging is controlled by the Power Conditioning and Distribution Unit (PCDU). The unregulated power is supplied either by the SpaceCraft (S/C) or the battery and gets distributed to the PFPS, communication radio, heaters, and deployables through the PDU. The PFPS generates all regulated low-voltage rails using switching regulation synchronized to the LuSEE-Night clock, which ensures self-generated EMI will be confined to well-defined frequency bins. Here, we discussed the unregulated power distribution system architecture and functionality. The PDU engineering and flight modules are developed and characterized to confirm compliance with LuSEE-Night requirements. At the time of writing, all power subsystem components have been integrated into the payload.

47 OTHER INSTRUMENTATION↗

Demonstrating the data center as a flexible grid asset using a C-HIL setup

Increasing data center demand is outpacing grid infrastructure development. Artificial intelligence workloads and hyperscale cloud growth are creating unprecedented demand for power, while traditional grid expansion faces multiyear development timelines. Verrus is developing an innovative datacenter solution for this challenge, data centers that act as active grid-supportive assets rather than passive loads. Our approach integrates a novel grid-aware power flow management system with battery energy storage systems(BESS) into a microgrid-controlled, medium-voltage power distribution architecture that delivers critical capabilities, such as: * Fast response to grid disturbances such over/ under voltage or over/ under frequency * Demand flexibility that can service requests from the utility within 10 s * Uninterrupted transition to islanded operation during grid outages * Continuous uptime assurance for compute loads while maintaining all customer service level agreements. Through Verrus' strategic partnership with the National Renewable Energy Laboratory (NREL), these capabilities were validated using NREL's Advanced Research on Integrated Energy Systems (ARIES) virtual emulation environment to model a 70-MW grid-interactive data center. This paper outlines the design, methodology, and results of this emulated deployment, demonstrating that data centers can provide both critical load resilience and ancillary grid support without compromising uptime requirements. Specifically, we present a digital real time simulation of a 70 MW data center integrated with a physical microgrid controller, and demonstrate the data center response in the event of a grid voltage and frequency event, utility demand response request and utility outage.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Extreme fast charging of commercial Li-ion batteries via combined thermal switching and self-heating approaches

Abstract The mass adoption of electric vehicles is hindered by the inadequate extreme fast charging (XFC) performance (i.e., less than 15 min charging time to reach 80% state of charge) of commercial high-specific-energy (i.e., >200 Wh/kg) lithium-ion batteries (LIBs). Here, to enable the XFC of commercial LIBs, we propose the regulation of the battery’s self-generated heat via active thermal switching. We demonstrate that retaining the heat during XFC with the switch OFF boosts the cell’s kinetics while dissipating the heat after XFC with the switch ON reduces detrimental reactions in the battery. Without modifying cell materials or structures, the proposed XFC approach enables reliable battery operation by applying <15 min of charge and 1 h of discharge. These results are almost identical regarding operativity for the same battery type tested applying a 1 h of charge and 1 h of discharge, thus, meeting the XFC targets set by the United States Department of Energy. Finally, we also demonstrate the feasibility of integrating the XFC approach in a commercial battery thermal management system.

25 ENERGY STORAGE↗

Application of Cyber-Informed Engineering for Protecting BESS

This white paper synthesizes an array of crucial grid services provided by BESS technology, assesses its architecture and communications, and presents a case study for analysis against the principles introduced by Cyber-Informed Engineering (CIE). Furthermore, in walking through the analysis, this paper presents a framework to evaluate risks and solutions when considering BESS components. Asset owners and buyers could perform this analysis to assess their BESS product implementations, alternative inverter-based resources (IBR), and energy management systems (EMS). Battery systems fulfill various roles contingent on the unique market demands and the specific challenges presented by regional grid infrastructures. These roles also vary due to the differing utility models for ownership and operation, which are adapted to meet regional and local capabilities and requirements. Concerns have been raised regarding the potential for adversaries to exploit knowledge of battery operational patterns to orchestrate decisive attacks. However, the security of operational data for these systems may not be the primary vulnerability, as much of this information is already well-understood within the community. Applying a modest degree of subject matter expertise can often yield valuable predictions regarding how a battery will respond under certain conditions, such as grid emergencies, high or low-temperature days, Public Safety Power Shutoff (PSPS) events, and outages. The operational characteristics of batteries are well-documented, and their capabilities, including the risks associated with misoperation and the resulting consequences, are published and understood within the industry. CIE practices represent the next step in gaining functional assurance and providing an acceptable level of risk, regardless of whether a battery vendor can support a trusted and validated supply chain. While this issue has exacerbated supply chain challenges, it is not an isolated condition. This foreign supply route is the primary source of BESS for the U.S. market. Significant efforts are underway through the Bipartisan Infrastructure Law (BIL) to change that. Still, strategic short-term operational mitigations are needed to ensure the security of our operational technology (OT) systems, which are enhanced by instilling trust and are separate from vendors implementing CIE principles.

25 ENERGY STORAGE↗

Li-Ion Battery Thermal Characterization for Thermal Management Design

Battery design efforts often prioritize enhancing the energy density of the active materials and their utilization. However, optimizing thermal management systems at both the cell and pack levels is also key to achieving mission-relevant battery design. Battery thermal management systems, responsible for managing the thermal profile of battery cells, are crucial for balancing the trade-offs between battery performance and lifetime. Designing such systems requires accounting for the multitude of heat sources within battery cells and packs. This paper provides a summary of heat generation characterizations observed in several commercial Li-ion battery cells using isothermal battery calorimetry. The primary focus is on assessing the impact of temperatures, C-rates, and formation cycles. Moreover, a module-level characterization demonstrated the significant additional heat generated by module interconnects. Characterizing heat signatures at each level helps inform manufacturing at the design, production, and characterization phases that might otherwise go unaccounted for at the full pack level. Further testing of a 5 kWh battery pack revealed that a considerable temperature non-uniformity may arise due to inefficient cooling arrangements. To mitigate this type of challenge, a combined thermal characterization and multi-domain modeling approach is proposed, offering a solution without the need for constructing a costly module prototype.

25 ENERGY STORAGE↗

Virtual Battery Aggregator (Virtual Battery Aggregator for Distributed Energy Resource Management Systems)

Distributed energy resource management systems (DERMS) are being deployed in feeders with high distributed energy resource (DER) penetration to provide visibility of DERs and enable DER control strategies for grid operators. DERMS can support centralized grid controls by aggregating individual DER information into a single virtual DER model. This codebase creates algorithms for a DERMS platform that are able to aggregate a set of DERs that can be modeled as batteries, create a virtual battery model for centralized grid controls, and dispatch power setpoints to the individual DERs based on a desired virtual power setpoint received from the centralized grid control. It integrates with existing co-simulation frameworks and models for buildings, DERs, and distribution systems. While the DERMS is designed to work with batteries, it can be used with any DER that can be defined by a generalized battery model.

Blonsky, Michael↗

Software defined grid energy storage

Today, consumer battery installations are isolated, physical devices. Virtual power plants (VPPs) allow consumer devices to aggregate for grid services, but they are are vertically integrated, vendor controlled systems (e.g., Tesla’s VPP). Consumer batteries are therefore unable to participate in energy markets or other grid services outside what their vendor provides. We describe a software system that provides software control of multiple, networked battery energy storage systems in the electric grid. The system introduces two new ideas that enable flexible and dependable management of energy storage. The first is a virtual battery, which can either partition a battery or aggregate multiple batteries. The second is a reservation-based API which allows asynchronous control of batteries to meet contractual guarantees in a safe and dependable manner. Virtual batteries and a reservation-based API address the unique challenges of achieving high and efficient utilization of energy storage systems, including heterogeneity of battery systems such as varying C-rates, participation in energy markets, utility bill management systems, community resource sharing, and reliability. Using a testbed comprised of sonnen Inc. storage units installed in several homes and a lab, we demonstrate that virtualized batteries can seamlessly replace physical batteries, flexibly manage energy storage resources, isolate multiple clients using a shared battery, and create new energy storage applications.

25 ENERGY STORAGE↗