Search NASA⌕ Search

SEARCH · Search NASA

Results for “battery thermal modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Heat Generation versus Heat Dissipation Maps for Batteries (Battery Safety Maps) [SWR-21-27]

NREL's Battery Safety Map (Heat Generation versus Heat Dissipation Maps for Batteries) generates a response surface that is grouped into regions where the battery is deemed safe from the propagation of thermal runaway, those where an engineering solution would render the battery safe, and finally instances where thermal runaway is inevitable. The demarcation for the different regions is provided by specifications or constraints imposed by the end user. NREL's Battery Safety Map is a user-defined subroutine that sweeps through a set of parameters describing the operating conditions and short-circuit scenarios for battery safety simulations. For each run, the electrochemical-thermal model implementing reaction kinetics and gas generation are run to evaluate the amount of heat generated. A thermal model then captures the amount of heat dissipation based on boundary conditions defined (e.g., forced convection, constant temperature at the surface, etc.). Based on the rate of heat transfer and the amount of heat generated, each run is classified into "safe," "mitigation possible," or "unsafe" zones. These categories are defined based on constraints or tolerance specifications provided by the end user.

Santhanagopalan, Shriram↗

Methods for Representing Flexible, Energy-Constrained Technologies in Utility Planning Tools

Capacity expansion models are widely used by power system researchers, planners, and policy analysts to evaluate alternative power system investment scenarios. With the increasing deployment of wind and solar in the US, there has been much focus on improving the representations of variable generation (VG) technologies within capacity expansion models. Models that capture the variable net-load profiles and larger reserve requirements associated with high penetration VG systems represent an improvement to classic capacity expansion models, but fall short of capturing the complexities associated with storage technologies, such as battery energy storage (BES) and concentrating solar power with thermal energy storage (CSP with TES). While difficult to model in a capacity expansion setting, these technologies are potentially competitive sources of flexibility with the intriguing characteristics of being able to absorb VG that would otherwise be curtailed and directly contribute to renewable energy goals, respectively. In this paper we present methods for accurately representing these technologies in a large-scale capacity expansion model with high electrical and geospatial resolution. VG modeling techniques, including novel methods for capturing curtailment due to unit commitment and other hourly dispatch phenomena, are also reviewed. Modeling for a region in the southwestern United States demonstrates the economic relevance of being able to explicitly trade off the costs and capabilities of energy-constrained technologies, especially BES, against other resources in the near-term, in time to make plans for the coming decade

24 POWER TRANSMISSION AND DISTRIBUTION↗

Synergies Between Building-Sited Batteries and Thermal Energy Storage

As renewable penetration increases, there is a greater need for energy storage systems located at buildings. This storage can include batteries, which directly shift the metered load, or thermal energy storage, which shifts thermal-driven electric loads like air conditioning. This presentation covers modeling results of the potential demand reduction and annualized cost savings for different combinations of thermal and battery energy storage sizes. It also shows how battery storage can expand the usefulness of thermal energy storage for electric load shaving, and how thermal storage can lower the cost of the overall storage system and extend battery lifetime by reducing cycling.

batteries↗

MODELING AND OPTIMIZATION OF A PCM-BASED OCEAN THERMAL ENERGY HARVESTER FOR POWERING UNMANNED UNDERWATER VEHICLES

As oceans cover over 70% of the planet’s surface, they represent a large reservoir of resources that remained vastly untapped. Uncrewed Underwater Vehicles (UUVs) are becoming key technology for ocean exploration. Ocean thermal gradient is a permanent and reliable energy source that can be used to power UUVs using phase change material (PCM)-based thermal engines. However, the main drawback of this technology is its low conversion efficiency. When using PCM-based thermal engines to power UUVs, there are different energy conversion stages, thermal-hydraulic, hydraulic-kinetic, kinetic-electrical, dependent of a wide variety of parameters. Thus, optimization of the overall energy conversion is still a challenge for powering the increasing energy demanding UUVs for long missions. The goal of this study is to propose a PCM-based ocean thermal energy harvesting system for powering the Solo II float. Using the ocean thermal energy reduces the cost for battery replacement and expands the float’s mission time. For this purpose, we developed a multiphysics model for a system consisting of thermal material, hydraulic, and electrical systems. This system is designed to provide the electrical power needed for the instruments aboard the underwater vehicle. The models of the hydraulic and the electric systems are implemented in MATLAB-Simulink/Simscape environment. The final model developed can provide 13.66 kJ of electrical energy, which is more than 1.5 times the energy requirement per cycle for the SOLO II float.

Ouro-Koura, Habilou↗

Comparing the economic performance of ice storage and batteries for buildings with on-site PV through model predictive control and optimal sizing

Integrating renewable energy and energy storage systems provides a way of operating the electrical grid system more energy efficiently and stably. Thermal storage and batteries are the most common devices for integration. However, it is not clear which integrated storage system performs better in terms of overall economics. Ice storage has low initial and maintenance costs, but there is an efficiency penalty for charging of storage and it can only shift electrical loads associated with building cooling requirements. A battery's round-trip efficiency, on the contrary, is quite consistent and batteries can be used to shift both HVAC and non-HVAC loads. However, batteries have greater initial costs and a shorter life. Finally, this research presents a tool, using model predictive control and optimal sizing, and provides a case study for comparing life-cycle economics of battery and ice storage systems for commercial buildings that have chillers for cooling and an on-site photovoltaic system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Investigation on the explosion dynamics of large-format lithium-ion pouch cells

Explosion is the most extreme case of thermal runaway of lithium-ion (Li-ion) batteries. In this study, explosion dynamics of large-format Li-ion cells are investigated experimentally and numerically. Overcharge-to-explosion tests are conducted on 40 Ah Li-ion cells with Li[Ni 0.8 Co 0.1 Mn 0.1 ]O 2 cathode. Based on the explosion physics, shockwave and detonation models are used to characterize the shock effect of the cell explosion and evaluate the explosion equivalent. Von Neumann peak is observed on the pressure curves, and the shockwave velocity is supersonic at this time; the unwrinkled spherical flame phenomenon observed in the experiment indicates that it is detonation. Additionally, a geometric model is established based on the real testing scenario, and the explosion behavior is numerically studied. The characteristics of the explosion dynamics process are interpreted and the propagation mechanism of the shockwave are revealed; the deflagration to detonation transition (DDT) phenomenon in this process is caused by the formation of “hot spots”, and the explosion of the cells eventually turns into stable combustion. Here this study fills the gap in the research on thermal runaway of Li-ion cells, especially in the extreme cases of fire and explosion, and provide useful guidance for battery safety.

42 ENGINEERING↗

Operando Depth-Resolved Measurement of Solvation Entropy, Interfacial Transport, and Charge-Transfer Kinetics in Lithium-Ion Batteries

Understanding and improving the performance and longevity of lithium-ion batteries critically depends on insight into the dynamic processes occurring at buried electrode-electrolyte interfaces. However, direct, depth-resolved, and operando diagnosis of these interfaces remains a longstanding challenge due to their inaccessibility beneath bulk materials, the limitations of conventional surface- and bulk-sensitive characterization tools, and the difficulty of maintaining realistic cell environments during measurement. These challenges have made it nearly impossible to uniquely resolve important interfacial properties such as charge transfer resistance, SEI (solid electrolyte interphase) resistance, and solvation entropy at the individual electrode interfaces within a working cell, information that is essential for mechanistic insight and accelerated battery design. Here, in this study, we report the development of multiharmonic electro-thermal spectroscopy (METS), an operando technique that enables depth-resolved measurement of solvation entropy, interfacial transport resistance, charge-transfer resistance, and SEI resistance at individual electrode-electrolyte interfaces within practical lithium-ion batteries. By leveraging frequency-dependent, thermal-wave sensing and interface-specific modeling, METS uniquely attributes interfacial properties to specific electrodes, as validated by comparison with traditional electrochemical impedance spectroscopy (EIS). The ability to spatially and temporally resolve interfacial processes in real time provides new diagnostic capabilities that are crucial for mechanistic studies of battery degradation and for the rapid development of next-generation energy storage systems.

Chalise, Divya [University of California, Berkeley↗

Modelling and analysis of nuclear reactor system coupled with a liquid metal battery

Traditionally, nuclear power plants in the U.S. provide baseload power to the power grid because they have less flexibility for ramping their output power than natural gas peaking plants. However, achieving climate goals to reduce the consumption of fossil‐based natural gas places pressure on nuclear power plants and other power generators to ramp up their power output to balance grid generation with demand. This paper presents the modelling and performance analysis of a nuclear reactor system (NRS) coupled to a liquid‐metal battery (LMB) to improve its dynamic response and enable its black start capability. The NRS and LMB thermal behaviour are modelled in Dymola, while the electrical dynamics of the LMB and power grid are modelled in RTDS‐RSCAD. Both simulation platforms are coupled and share their thermal and electrical data using a Transmission Control Protocol/Internet Protocol (TCP/IP) communication protocol. The dynamic performance of the NRS‐LMB integration is tested on the IEEE 9 bus, which demonstrates its ability to respond and provide frequency and voltage regulation. The black start capability of the NRS‐LMB is also evaluated by simulating a grid outage and using the LMB to supply the auxiliary loads required to bring the NRS back online as soon as possible. The results show that coupling an NRS to an LMB improves the system dynamic performance and enables it to black start after being disconnected from the grid for several days.

25 ENERGY STORAGE↗

Techno-Economic Analysis and Market Potential of Geological Thermal Energy Storage (GeoTES) Charged With Solar Thermal and Heat Pumps

In this project, we developed a techno-economic analysis (TEA) model that can be used to evaluate the viability of a proposed Geological Thermal Energy Storage (GeoTES) design. This MATLAB-based model integrates distinct subsystem models for the reservoir, wells, power cycle, and solar field to capture their distinct characteristics. It applies this approach in simulating GeoTES storage and dispatch operations for durations ranging from hourly to seasonal. Using cases studies based on GeoTES designs provided by industry partners - Premier Resource Management (PRM) and EarthBridge Energy - we validated the TEA model estimations of system performance and costs (such as thermal and electrical power/energy inflow and outflow, capital costs, and levelized costs of energy and storage) for both concentrating solar thermal (CST) and Carnot Battery (CB) pairings with GeoTES (CST-GeoTES and CB-GeoTES). For the CST-GeoTES case, the model was validated against the proposed system designed by PRM. It showed good agreement with PRM's estimations when well and pump costs derived from PRM's estimations were used. When GETEM-based costs were used, there was a slight overprediction due to GETEM's project/site agnostic assumption of these costs. From a sensitivity analysis perspective, the levelized cost of electricity (LCOE) of the CST-GeoTES case was most sensitive to well flow rate and the charging temperature. An optimal design scenario resulted in an LCOE of 0.11 $\$$/kWhe. CST-GeoTES can also provide a source of heat to meet seasonal demands. With 12-hour and 24-hour levelized cost of heat (LCOH) of 0.018 $\$$/kWhth and 0.022 $\$$/kWhth, respectively, CST-GeoTES could be competitive in the California market with an average industrial price of natural gas in California between 0.041-0.047 $\$$/kWhth. The levelized cost of storage (LCOS) for CST-GeoTES depends on the energy storage duration. Although the LCOS is relatively higher for shorter durations (e.g., ~0.50 $\$$/kWhe for 1 hour of storage), it is an order of magnitude lower (0.06 $\$$/kWhe) for longer storage durations and competitive with lithium-ion batteries (beyond 12 hours of storage) and molten-salt thermal energy storage (beyond 32 hours). Energy. Three options were explored and applied to the EarthBridge case study: (1) A Carnot Battery design using R125 working fluid with both hot and cold storage; (2) A Carnot Battery design using R125 working fluid with only hot storage; (3) A Carnot Battery using a commercially available heat pump with carbon dioxide (CO2) working fluid and hot storage only. The CB-GeoTES with cold storage only had a slight (round-trip) efficiency advantage over the system without (43.4% vs. 42.8%). This is because the cold storage is limited by the freezing point of water, so the cold storage is not much colder than the environment. The system using commercially available technologies was the least efficient - partly because different cycles were used in the heat pump (CO2) and heat engine (binary cycle) which leads to some inefficiencies. Using the commercially available design, the levelized cost of energy (LCOS) from the model (0.10 $\$$/kWhe) was higher than that estimated by EarthBridge (0.068 $\$$/kWhe). This is because of the low round-trip (38.7%) efficiency of the commercially available design. Sensitivity analysis reveals that the model is most sensitive to electricity price. Including electricity price in the TEA for CB-GeoTES leads to an increase in LCOS from the base value to 0.25 $\$$/kWhe. To determine storage sites suitable for GeoTES, we gathered and analyzed geological, petrophysical, and geophysical data of oil and gas reservoir and aquifers in California and Texas. We down-selected possible sites based on cut-off values for site characteristics (e.g., reservoir temperature, formation thickness, permeability, porosity, depth, and brine salinity) and preliminary costs. Using this approach, the Carrizo-Wilcox, Yegua-Jackson, and Dockum brackish aquifers in Texas were identified as having the highest suitability. Similarly, in the central California region, the White Wolf, Belridge South Tulare, and Belridge South Reef Ridge were the most suitable. Going further, we assessed the storage potential in the selected sites. To do this we developed distributions of reservoir characteristic data and applied a Monte Carlo-based analysis to account for intrinsic uncertainty in the acquired data. The analysis revealed that the Carrizo-Wilcox aquifer had the highest storage potential with a mean capacity of 554 TWhth (i.e., 63 TWhe). The estimated capacity serves as an upper limit of storage potential given that not all fields in the basin will be developed. We participated in multiple outreach activities including conference presentations, panel session discussions, and the facilitation of a GeoTES workshop at the NREL Golden campus.

15 GEOTHERMAL ENERGY↗

Observation and Modeling of Dynamic Fracture Behaviors of Battery Cell Under Impact Loading Using Enhanced Representative Volume Element Concept

The burgeoning electric automobile industry has increased interest in battery safety. Battery cells experience significant mechanical stress during operation, including the impact of accidents and vibrations from driving. The potential for thermal runaway reactions in battery cells raises safety concerns. Although numerous researchers have defined the dynamic behavior of battery cells and proposed numerical models to describe it, few studies have focused on the high-strain rate mechanical impact phase correlated with the onset of fracture. In this study, we describe the dynamic behavior of pouch battery cells and propose a modeling method to study their mechanical failure under impact situations. Impact tests are conducted at various velocities and heights. To overcome numerical issues commonly encountered under rapid deformation scenarios, a new finite element model is developed based on the representative volume element model. The proposed approach efficiently simulates continuous crack propagation and brittleness behavior during impact by permitting the individual behavior of the cell components. Therefore, engineers can reliably design safer electric vehicle battery cells by measuring the properties of the cell components.

ENERGY STORAGE↗

Control Oriented Model of Cabin-HVAC System in a Long-Haul Trucks for Energy Management Applications

Super Truck II is a 48V mild hybrid class 8 truck with an all auxiliary loads powered purely by the battery pack. Electric Heating Ventilation and Air Conditioning (HVAC) load is the most prominent battery load during the hotel period, when the truck driver is resting inside the sleeper. For the PACCAR Super Truck II (ST-II) project a 48 V battery system provides the required power during the hotel period. A cabin-HVAC model estimates the electric load on the 48V battery system, allowing the control system to implement an efficient energy management strategy that avoids engine idling during the hotel period. The thermal model accounts for the sun load due to the time of day and the geographic location of the truck during the hotel period. The cabin-HVAC model has two parts. First, a grey box model with two heat exchangers (Condenser and Evaporator) working in unison with refrigerant mass flow rate as an input and HVAC load as an output. Second, a two-node cabin model formulated to estimate the cabin temperature as a function of the Global Horizontal Irradiance (GHI), HVAC load and ambient temperature. The models are calibrated using experimental cabin-HVAC system data as for long-haul class 8 truck (e.g. ST-II). Here, the model simulations show that the overall Root Mean Square Error (RMSE) value of 0.4°C between the experimental and simulated cabin temperature.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Supervised Learning for Distribution Secondary Systems Modeling: Improving Solar Interconnection Processes

The current interconnection process and hosting capacity analysis for distributed energy resources (DERs), such as photovoltaics (PV) and battery energy storage systems, are based on analyzing grid network constraints (voltage and thermal) using only medium-voltage distribution network models. This is because most utilities do not have secondary low-voltage system models that connect service transformers and residential customers. This is important because in many cases the main impact of interconnecting DERs could occur on the low-voltage distribution systems. This paper proposes a supervised learning method to approximate local secondary models to improve the interconnection process. The proposed supervised learning method includes a decision tree model that predicts the secondary topology and a logistic regression model that predicts conductor types. The case studies demonstrate the benefits of including secondary low-voltage circuits in the interconnection process. We report the proposed modeling methodology is readily scalable and thus can reduce the cost and effort of PV interconnection for the industry and stakeholders.

14 SOLAR ENERGY↗

Development and Validation of a Simulation Tool to Predict the Combined Structural, Electrical, Electrochemical and Thermal Responses of Automotive Batteries

Battery safety is one of the most important design factors of electrified vehicles (EVs) since battery failure may lead to a catastrophic consequence. To improve the safety of battery systems in EVs, battery behaviors under various abuse conditions should be well understood. One way to examine battery response under extreme conditions is to conduct abuse tests in different scenarios. They can provide first-hand pass/fail information on battery safety, but they are usually expensive and time-consuming, which is inconvenient during design iterations and optimization. On the other hand, computational modeling can predict the battery behaviors in a more efficient and cost-effective way, which becomes an important tool to evaluate battery safety. Modeling battery responses and failure is challenging since it involves multiple coupled physical processes, needs to consider complex material properties and is computationally intensive. This project aims to develop a practical simulation tool to predict the combined structural, electrical, electrochemical, and thermal responses of automotive batteries to crash-induced crush and short circuit and validate it for conditions relevant to automotive crash. Advanced material constitutive models will be utilized to capture the mechanical response of cell components. Moreover, methods will be developed to reduce computational complexity of the model and allow battery safety simulations to extend from cell-level to module/pack level with affordable computational resources.

25 ENERGY STORAGE↗

Ultrafast charging of energy-dense lithium-ion batteries for urban air mobility

Urban air mobility (UAM) demands batteries with high energy density, long cycle life, and fast rechargeability. In this paper, we demonstrate an energy-dense lithium-ion battery (LiB) with ultralong cycle life under ultrafast charging. By using the asymmetric temperature modulation (ATM) method, i.e., charging at an elevated temperature and discharging around the ambient temperature, it is experimentally shown that the 209 Wh/kg LiB is charged to 88% state of charge (SOC) in ~5 min under UAM cycling while retaining 97.7% capacity after 1,000 cycles. Moreover, an experimentally validated electrochemical-thermal (ECT) model is developed to elucidate the fast charging process and the degradation mode of UAM batteries, quantitatively capturing lithium plating during fast charging. We find that the LiBs for UAM applications are most prone to lithium plating due to their higher initial SOC required as the reserve for safety; nevertheless, the ATM method is effective in minimizing or preventing lithium plating in the high SOC range of 30-90%. In addition to slowing down capacity fade, the ATM method also raises the usable capacity by 10%, which boosts the battery energy density and ensures the battery to perform full UAM cycles even at the end of life.

25 ENERGY STORAGE↗

Review—Thermal Safety Management in Li-Ion Batteries: Current Issues and Perspectives

Approaches for thermal management of lithium-ion (Li-ion) batteries do not always keep pace with advances in energy storage and power delivering capabilities. Root-cause analysis and empirical evidence indicate that thermal runaway (TR) in cells and cell-to-cell thermal propagation are due to adverse changes in physical and chemical characteristics internal to the cell. However, industry widely uses battery management systems (BMS) originally designed for aqueous-based batteries to manage Li-ion batteries. Even the "best" BMS that monitor both voltage and outside-surface temperature of each cell are not capable of preventing TR or TR propagation, because voltage and surface-mounted temperature sensors do not track fast-emerging adverse events inside a cell. Most BMS typically include a few thermistors mounted on select cells to monitor their surface temperature. Technology to track intra-cell changes that are TR precursors is becoming available. Simultaneously, the complex pathways resulting in cell-to-cell TR propagation are being successfully modelled and mapped. Innovative solutions to prevent TR and thermal propagation are being advanced. These include modern BMS for rapid monitoring the internal health of each individual cell and physical as well as chemical methods to reduce the deleterious effects of rapid cell-to-cell heat and material transport in case of TR.

25 ENERGY STORAGE↗

Operating a commercial building HVAC load as a virtual battery through airflow control

Virtual battery (VB) is an innovative method to model flexibility of building loads and effectively coordinate them with other resources at a system level. Unlike a real battery with a dedicated power conversion system for charging control, methods are required for operating building loads to deviate from the baseline to respond to grid signals. This paper presents a VB control for a commercial heating, ventilation, and air conditioning (HVAC) system to follow the desired power consumption in real-time by adjusting zonal airflow rates. The proposed method consists of two parts. At the system level, a mixed feedforward and feedback control is used to estimate the desired total airflow rate. At the zone level, two priority-based algorithms are then proposed to distribute the total airflow rate to individual zones. In particular, a zonal airflow limit estimation method is proposed using machine-learning techniques, in contrast to physics-based thermal models in existing studies, to more accurately capture zonal thermal dynamics and improve temperature control performance. An office building on the Pacific Northwest National Laboratory campus is implemented in EnergyPlus, and used to illustrate and validate the proposed control.

Wang, Jiyu↗

Potential of Data Center Controls in Grid Services

The rapid proliferation of large data centers brings both challenges and opportunities for grid reliability. The data center resources and their potential flexibility have the potential to contribute resources to grid operations. Through capabilities like energy shifting and resource coordination, data centers can help reduce their net demand on the transmission network, as well as provide additional grid services to support reliable operation on the grid. While transient and long-term grid planning and operations are the scenarios that draw most attention, the quasi-steady state timeseries (QSTS) operation of data centers and grid bring interesting scenarios that can help evaluate the data center controls to aid grid services. This work is focused on modeling data centers for QSTS applications – incorporating the AI data center load profiles and building on the PNNL digital twin model for the thermal management loads to enable simulation studies to reveal the impact of data center controls on grid performance. This includes the integration of a QSTS battery and natural gas generator model to incorporate local resource impacts to the system. The simulation study is performed with a modified IEEE 24-Bus transmission system. Scenarios are focused on evaluating the data center load impacts on the transmission system and leveraging both data center and local generation controls to mitigate those impacts and provide additional grid services. The data center controls revealed the ability to contribute to two main kinds of grid services: preventing congestion on a weak grid by coordinating the data center resources with the collocated BESS and onsite generation; and the ability to help the grid operations during stressed times of operation like during a contingency. Leveraging these and other capabilities has the potential to help data centers become grid responsive assets, aiding in both their integration into the power system and grid reliability.

power grid simulation↗

A hierarchical framework for aggregating grid-interactive buildings with thermal and battery energy storage

The behind-the-meter (BTM) thermal and battery energy storage can help improve energy efficiency, reduce energy costs, and enhance energy resilience, particularly in rural areas and for disadvantaged communities. Aggregating numerous BTM energy storage systems can act as a price influencer with a significant source of load shifting and peak demand reduction. An integrated and scalable control mechanism is required to effectively utilize energy storage systems and flexible building loads to maximize the economic benefits, considering various distribution system constraints. Here, this paper presents an innovative hierarchical coordination framework for energy storage and flexible load in buildings, considering various factors such as electricity prices, thermal comfort, and distribution system modeling and constraints. At the upper level, a distribution system operator optimizes the power flow to minimize its power procurement costs from the electricity wholesale market, while at the lower level, aggregators determine the optimal dispatch of battery and thermal energy storage systems in multiple buildings on behalf of end-users to minimize operating costs according to the power prices. These problems are solved using a game-theoretic approach through negotiations between the distribution system operator and aggregators as a bi-level decision model. Simulation case studies have been performed for a test distribution network with a number of building end-users using energy storage systems to quantify the performance of aggregators. The results demonstrate that the proposed strategy can reduce peak load for a reliable electricity distribution network while saving electricity bills for customers.

25 ENERGY STORAGE↗