Search NASA⌕ Search

SEARCH · Search NASA

Results for “beam independence”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Conceptual study on using Doppler backscattering to measure magnetic pitch angle in tokamak plasmas

We introduce a new approach to measure the magnetic pitch angle profile in tokamak plasmas with Doppler backscattering (DBS), a technique traditionally used for measuring flows and density fluctuations. The DBS signal is maximised when its probe beam's wavevector is perpendicular to the magnetic field at the cutoff location, independent of the density fluctuations [Hillesheim \emph{et al} 2022 \emph{Nucl. Fusion} \textbf{55} 073024]. Hence, if one could isolate this effect, DBS would then yield information about the magnetic pitch angle. By varying the toroidal launch angle, the DBS beam reaches cutoff with different angles with respect to the magnetic field, but with other properties remaining similar. Hence, the toroidal launch angle which gives maximum backscattered power is thus that which is matched to the pitch angle at the cutoff location, enabling inference of the magnetic pitch angle. We performed systematic scans of the DBS toroidal launch angle for repeated DIII-D tokamak discharges. Experimental DBS data from this scan were analysed and combined with Gaussian beam-tracing simulations using the Scotty code [Hall-Chen \emph{et al} 2022 \emph{Plasma Phys. Control. Fusion} \textbf{64} 095002]. The pitch-angle inferred from DBS is consistent with that from magnetics-only and motional-Stark-effect-constrained (MSE) equilibrium reconstruction in the edge. In the core, the pitch angles from DBS and magnetics-only reconstructions differ by one to two degrees, while simultaneous MSE measurements were not available. The uncertainty in these measurements was under a degree; we show that this uncertainty is primarily due to the error in toroidal steering, the number of toroidally separated measurements, and shot-to-shot repeatability. We find that the error of pitch-angle measurements can be reduced by optimising the poloidal launch angle and initial beam properties. Since DBS has high spatial and temporal resolutions, is non-perturbative, does not require neutral beams, and is likely robust to neutron damage of and debris on the first mirrors, using DBS to measure the pitch angle in future fusion energy systems is especially appealing.

beam tracing↗

The high level trigger and express data production at STAR

To meet the demands of the Beam Energy Scan phase-II (BES-II) program, the STAR experiment at the Relativistic Heavy Ion Collider (RHIC) developed a dual real-time framework consisting of a High Level Trigger (HLT) and an Express Data Production system (xProduction). The HLT operates online within the Data Acquisition (DAQ) chain on a dedicated multi-core CPU cluster with the option to offload compute-intensive kernels to Xeon Phi coprocessors. It uses parallelized algorithms, such as the Cellular Automaton (CA) Track Finder, to perform rapid tracking, vertexing, and event filtering. This allows it to select events of interest in real time and provide immediate feedback on detector and beam conditions. In contrast, the xProduction workflow runs concurrently and independently of the DAQ loop. It applies near offline-quality calibration and reconstruction within hours of data collection. The xProduction input is the express data stream, whose content can be enriched by HLT trigger/priority selections under DAQ/HLT resource constraints, and it uses the STAR calibration/conditions framework, incorporating online calibration/QA information when available. This enables early preliminary physics analysis, including the reconstruction of rare signals, such as hyperons and hypernuclei. It also provides collaboration-wide access to analysis-ready datasets. Together, the HLT and xProduction systems form a complementary architecture: the HLT performs online event selection while the xProduction chain delivers high-quality results within a short amount of time. This integrated framework has enabled the prompt reconstruction of the $^5_Λ$ He hypernucleus with high statistical significance and the efficient processing of hundreds of millions of heavy-ion collision events. In conclusion, its demonstrated scalability and robustness establish a model for future high-luminosity experiments requiring both online event filtering and rapid access to analysis-quality data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Quantitative phase imaging by gradient retardance optical microscopy

Abstract Quantitative phase imaging (QPI) has become a vital tool in bioimaging, offering precise measurements of wavefront distortion and, thus, of key cellular metabolism metrics, such as dry mass and density. However, only a few QPI applications have been demonstrated in optically thick specimens, where scattering increases background and reduces contrast. Building upon the concept of structured illumination interferometry, we introduce Gradient Retardance Optical Microscopy (GROM) for QPI of both thin and thick samples. GROM transforms any standard Differential Interference Contrast (DIC) microscope into a QPI platform by incorporating a liquid crystal retarder into the illumination path, enabling independent phase-shifting of the DIC microscope's sheared beams. GROM greatly simplifies related configurations, reduces costs, and eradicates energy losses in parallel imaging modalities, such as fluorescence. We successfully tested GROM on a diverse range of specimens, from microbes and red blood cells to optically thick (~ 300 μm) plant roots without fixation or clearing.

47 OTHER INSTRUMENTATION↗

Electro- and photoproduction of muon pairs with $$\mu $$CLAS12: double deeply virtual compton scattering, timelike compton scattering, and $$J/\psi $$ production

The CEBAF Large Acceptance Spectrometer for operation at 12 GeV (CLAS12) at the Thomas Jefferson National Accelerator Facility has played a central role in advancing the understanding of nucleon and nuclear structure. As increasingly precise data become available, new physics opportunities emerge that extend beyond the current capabilities of CLAS12. In this article, a program to explore the quark and gluon structure of the nucleon through di-muon electro- and photoproduction is presented. Its primary focus is the measurement of beam-spin asymmetries in Double Deeply Virtual Compton Scattering, . By independently varying the incoming and outgoing photon virtualities and momentum transfer, the DDVCS measurement provides access to the Generalized Parton Distributions over their full three-dimensional phase space, extending beyond the kinematic constraints of Deeply Virtual Compton Scattering and Timelike Compton Scattering. In addition, the large acceptance and high luminosity of the CLAS12 experiment will enable precision measurements of near-threshold production and high-statistics studies of Timelike Compton Scattering.

Alvarado, J. S.↗

Equivalent equilibrium ion distributions in ion sources and beams

Ion sources and ion beams often contain ions of more than one charge-to-mass ratio, due to the presence of multiple ionization states and/or multiple atomic and molecular ion species in the source. We show that, under certain conditions, analysis of these systems can be simplified using the notion of “equivalent equilibrium ion distributions” (EEIDs). These distributions have identical ion trajectories, space-charge distributions, and electric-field distributions, but can be composed of ion species with arbitrary charge-to-mass ratios. We use this result to obtain multi-species generalizations for the perveance of an ion diode, which relates the diode voltage to the extracted beam current, and for the perveance of a drifting ion beam, which determines the axial length-scale for beam expansion due to the self-electric field. Applied to a quasi-neutral plasma ion source containing cold ions and hot electrons, we find that the location of the beam-plasma interface (meniscus), where ions are extracted from the plasma, depends on the electron density and ion energy per unit charge at the interface, independent of the ion composition. For certain types of numerical simulations, EEIDs allow one to calculate the beam optics of an intense multi-species ion source by doing a simulation for a single ion species with an artificial charge-to-mass ratio chosen to minimize computation time. We illustrate these results using the 3D particle-in-cell, finite-element code Aleph. The simulations show how ions in a plasma source self-consistently accelerate to the supersonic speed needed for steady, radially expanding flow. Multi-species equilibria are subject to streaming instabilities because, while the different species have the same kinetic energy per unit charge, their velocities scale with the square root of the charge-to-mass ratio. The simulations show that a strong ion streaming instability can occur in a multi-species plasma ion source.

74 ATOMIC AND MOLECULAR PHYSICS↗

Energy dependence of light hypernuclei production in heavy-ion collisions from a coalescence and statistical-thermal model perspective

A comparison of light hypernuclei production, from Ultra-relativistic Quantum Molecular Dynamics (UrQMD)+coalescence and the thermal model, in heavy ion collisions over a wide range of beam energies and system sizes is presented. We find that both approaches provide generally similar results, with differences in specific details. Especially the ratios of hypertriton to Λ are affected by both the source radius Δr of the coalescence procedure as well as canonical effects. On the other hand, the double ratio S 3 is almost independent of canonical effects, which is in contrast to coalescence. Thus, both the beam energy dependence and centrality dependence of S 3 can be used to constrain the hypertriton source radius. To do so the currently available data are not yet sufficient. Elliptic flow is shown to be unaffected by the source size of the nuclei and an almost perfect mass scaling of the elliptic flow is observed. Furthermore, our predictions further suggest that the existence of the H-dibaryon(ΛΛ) seems ruled out by ALICE data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Design study for a compact, two-stage, laser-plasma-based source of positron beams

Owing to their large accelerating gradients, plasma-based accelerators have attracted considerable interest as potential drivers for future, compact electron–positron colliders. Despite great progress achieved in plasma-based electron acceleration, positron acceleration still remains a challenging task, with an efficient positron source being the prerequisite for such acceleration. Here a concept for a compact, two-stage plasma-based positron source is discussed. In the first stage the positrons are created by a multi GeV electron beam produced by a laser-plasma accelerator interacting with a solid density foil. In the second stage the positrons are captured and accelerated in a plasma wave driven by either an electron beam or a laser pulse. Three potential configurations of such a source are considered: (i) a single electron beam is used for both the creation of positrons in the foil and for driving the wakefield in the second stage; (ii) a train of two electron beams is used: the positrons produced by the trailing beam in the foil are captured and accelerated in the second stage by the plasma wave generated by the leading beam; and (iii) a single electron beam is used to produce positrons in the foil and an independent laser pulse is coupled to the second stage to drive the plasma wave. In conclusion, these three configurations show different degrees of effectiveness with positron capture efficiency, varying from less than a percent to almost half of all produced positrons.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Transverse BBU Suppression with Feedback for Energy-Recovery Linacs

The Electron–Ion Collider (EIC) achieves its design luminosity by cooling the ion beam with a high-current electron beam generated in an energy-recovery linac (ERL). The baseline ERL lattice employs a BNL five-cell cavity that is frequency-scaled to 197 MHz, 591 MHz, and 1.773 GHz, raising concerns about multibunch beam-breakup (BBU) instabilities. Threshold currents for each frequency option are established with two independent BBU tracking codes, providing cross-validated operating margins that guide cavity selection. To further increase the current limit, we incorporate a digital transverse feedback (FB) system that targets the dominant higher-order modes (HOMs). Simulations show the FB raises the BBU threshold by roughly an order of magnitude: power-spectral-density analysis of the beam centroid at the linac exit confirms strong suppression of the aliased HOM peak, although some spectral growth appears at secondary frequencies. This combined study quantifies baseline BBU limits, demonstrates effective active mitigation, and charts a practical path toward robust, high-current operation of the EIC ERL.

Accelerator Physics↗

A LENS on DUNE-PRISM: Characterizing a Neutrino Beam with Off-Axis Measurements

Upcoming precision long-baseline neutrino oscillation experiments will be severely limited by the large systematic uncertainties associated with neutrino flux predictions and neutrino--nucleus cross sections. A promising remedy is the PRISM (Precision Reaction Independent Spectrum Measurement) technique, whereby the near detector measures the neutrino spectrum at different angles with respect to the beam axis. These measurements are then linearly combined into a prediction of the oscillated neutrino flux at the far detector. This prediction is data-driven, but still dependent on some theoretical knowledge about the neutrino flux. In this paper, we study to what extent off-axis measurements themselves can be used to directly constrain neutrino flux models. In particular, we use them to extract separately the fluxes and spectra of different meson species in the beam. We call this measurement LENS (Lateral Extraction of Neutrino Spectra). Second, we demonstrate how the thus improved flux model helps to further constrain the far detector flux prediction, thereby ultimately improving oscillation measurements.

FOS: Physical sciences↗

Broad band tunable energy electron beam pulser

An electromagnetic mechanical pulser implements a transverse wave metallic comb stripline TWMCS kicker having inwardly opposing teeth that retards a phase velocity of an RF traveling wave to match the kinetic velocity of a continuous electron beam, causing the beam to oscillate before being chopped into pulses by an aperture. The RF phase velocity is substantially independent of RF frequency and amplitude, thereby enabling independent tuning of the electron pulse widths and repetition rate. The TWMCS further comprises an electron pulse picker (EPP) that applies a pulsed transverse electric field across the TWMCS to deflect electrons out of the beam, allowing only selected electrons and/or groups of electrons to pass through. The EPP pulses can be synchronized with the RF traveling wave and/or with a pumping trigger of a transverse electron microscope (TEM), for example to obtain dynamic TEM images in real time.

42 ENGINEERING↗

Tailoring coherent beam combined laser pulse trains for high peak and average power applications

Laser systems based on coherent beam combination (CBC) that rely on tiled pupil architecture intrinsically carry digital capabilities independently applicable to all three essential characteristics of a laser pulse: amplitude, phase and polarization. Those capabilities allow the far-field energy distribution to be flexibly tailored in real time. Operation in the femtosecond regime at high repetition rates gives access to a wide range of applications requiring both high peak and average powers. We address the task of independent peak versus average power adjustment needed for applications seeking to decouple nonlinear phenomena associated with GW peak power from the thermal load inherent to kW average power operation. The technical solutions proposed are presented in the framework of the Ecole Polytechnique XCAN CBC laser platform (61 independent channels) with an emphasis on thermal management measures implemented to ensure its nominal operation.

47 OTHER INSTRUMENTATION↗

Multi-modal dynamic radiography using short-pulse laser-generated probe beams

Radiography is an important tool for the interrogation of dynamic experiments in the fields of dynamic properties of materials, and in condensed matter, high explosive, and high-energy-density physics. Multi-modal radiography advances the hypothesis that combining the information delivered by multiple radiographic modalities can lead to more constrained (improved) “reconstruction” of the scene than can be obtained from a single probe. We identify four modalities: multi-probe, time sequence, multi-view, and multi-messenger. Multi-probe radiography is a promising candidate for a next-generation dynamic radiographic facility. High-energy X-rays are the most frequently used probe for dynamic radiography, although recent developments show the utility of proton (pRad), electron (eRad), and neutron probe beams. Because each probing species interacts with material in the radiographic scene through quantitatively different mechanisms, each returns independent information about the scene, which can add extra constraints to the reconstruction process. How to conduct detailed, quantitative “co-analysis” of multiple data streams remains an area of active research. Multi-beam, short-pulse, laser-generated probes offer sufficient dose, an appropriate spectrum, and appropriate spatio-temporal resolution to produce high-quality dynamic radiographs. This paper reports on technology development to advance the state of the art of multi-modal/multi-probe radiography and the pursuit of both deterministic and inferential (AI/ML assisted) co-analysis methodologies to produce more constrained reconstructions from multi-modal data.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Three-Dimensional Particle-in-Cell Analysis of Mechanical Design Tolerances of the Scorpius Injector With Warp

Here, this article examines the mechanical design tolerances for the Scorpius injector using a 3-D particle-in-cell (PIC) code. In order to meet its objective as a high-fidelity, multipulse flash X-ray source, the accelerator has requirements for the electron beam in order to minimize the spot size of the beam focused onto a foil target to create high fluence X-rays at energies greater than 10 MeV. The requirements for alignment of the cathode, anode beam pipe, focusing solenoids, and transport solenoids specified using Trak and AMBER are independently verified using a 3-D electrostatic/magnetostatic model of the Scorpius injector, including transverse magnetic field errors that arise from mechanical alignment errors. It is predicted that the injector will meet the performance requirements for radiographic operation and has a design margin to correct for potentially unforeseen operating conditions.

42 ENGINEERING↗

Transition width of the of the $J$ $π$ = $1$ – two-phonon state of $88$ $Sr$

The ground-state decay width of the two-phonon $J$ $π$ = $1$ – , 4742 keV state of 88 Sr has been determined with the relative self-absorption method combined with a monoenergetic photon beam. This width is important to determine the decay transition strengths into the ground state and the one-phonon $2$$^{+}_{1}$ and $3$$^{–}_{1}$ levels which are required to verify the two-phonon character of the $J$ $π$ = $1$ – state. Here, the experiment was performed at the High Intensity γ-ray Source (HI⁢ γ⁢S) using a novel experimental approach to adapt the relative self-absorption method to monoenergetic photon beams. The result for the ground-state decay width is, thus, independent of any calibration standard and confirms the two-phonon character of the 88 Sr, $J$ $π$ = $1$ – , 4742 keV state within an improved uncertainty.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

IsoDAR@Yemilab: Preliminary design report—volume I (cyclotron driver)

This Preliminary Design Report (PDR) describes the IsoDAR electron-antineutrino source in two volumes which are mostly site-independent and describe the cyclotron driver providing a 10 mA/60 MeV proton beam (this Volume); and the medium energy beam transport line (MEBT) and target (Volume II). The IsoDAR driver and target will produce about 1.15 x 10 23 electron-antineutrinos over 5 years while operating with the anticipated 10 mA/60 MeV beam at an estimated 80% duty factor. Paired with a kton-scale liquid scintillator detector, it will enable a broad particle physics program including searches for new symmetries, new interactions and new particles. Here in Volume I, we describe the driver, which includes the ion source, low energy beam transport, and cyclotron. The latter features Radio-Frequency Quadrupole (RFQ) direct axial injection and represents the first accelerator purpose-built to make use of so-called vortex motion.

Winklehner, Daniel (ORCID:0000000207156310)↗

Two-particle correlations in azimuthal angle and pseudorapidity in central $^7\hbox {Be}+{}^9\hbox {Be}$ collisions at the CERN Super Proton Synchrotron

A measurement of charged hadron pair correlations in two-dimensional $\Delta \eta \Delta \phi $ space is presented. The analysis is based on total 30 million central Be + Be collisions observed in the NA61/SHINE detector at the CERN SPS for incident beam momenta of 19A, 30A, 40A, 75A, and 150A $\text {Ge} \text {V}/c$. Measurements were carried out for unlike-sign and like-sign charge hadron pairs independently. The $C(\Delta \eta ,\Delta \phi )$ correlation functions were compared with results from a similar analysis on p + p interactions at similar beam momenta per nucleon. General trends of the back-to-back correlations are similar in central Be + Be collisions and p + p interactions, but are suppressed in magnitude due to the increased combinatorial background. Predictions from the Epos and UrQMD models are compared to the measurements. Evolution of an enhancement around $(\Delta \eta ,\Delta \phi ) = (0,0)$ with incident energy is observed in central Be + Be collisions. It is not predicted by both models and almost non-existing in proton–proton collisions at the same momentum per nucleon.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

On extraction of twist-two Compton form factors from DVCS observables through harmonic analysis

We investigate the exercise of locally extracting the real and imaginary parts of the four twist-2 Compton form factors (CFFs) {$\mathcal{H,E,\tilde H,\tilde E}$} which arise in the deeply virtual Compton scattering (DVCS) process e + p → e + p + y. Neglecting dynamical higher-twist contributions, we find that there are a sufficient number of DVCS observables and degrees of freedom to extract all 8 leading quantities model-independently, exploiting the azimuthal dependence of the absolute cross sections across all possible beam and target polarizations at a common kinematical point in {Q, t,x b , y}. As an example, for typical JLab lab-frame kinematics, we simplify the reduced DVCS observables to their dominant terms, providing a sufficient number of equations for local determination of the twist-2 CFFs. We demonstrate the feasibility using harmonic fitting to both cross sections and beam spin asymmetries with both real and pseudo-data.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurements of the 239 Pu(n,f)/ 235 U(n,f) and 238 U(n,f)/ 235 U(n,f) Cross-Section Ratios Using Quasi-Monoenergetic Neutron Beams

Neutron-induced fission cross-section ratio measurements were carried out at Triangle Universities Nuclear Laboratory (TUNL) over multiple experiment campaigns from 2021-2023. The total beam time for these measurements across all the experimental campaigns was approximately three weeks. This work was intended to serve as an independent validation of the fissionTPC cross-section ratio measurements. In contrast to the white spectrum neutron source and time-projection chamber utilized in the fissionTPC, these measurements utilized pulsed, quasi-monoenergetic neutron beams and fission ionization chambers. Therefore, this work has different sources of systematic error and can be used as a complementary measurement. In this report we describe our fission cross-section ratio measurements, analysis, results and provide a detailed uncertainty budget.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗