Search NASA⌕ Search

SEARCH · Search NASA

Results for “bellows”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Polymeric Bladder for Storing Liquid Oxygen

A proposed system for storing oxygen in liquid form and dispensing it in gaseous form is based on (1) initial subcooling of the liquid oxygen; (2) containing the liquid oxygen in a flexible vessel; (3) applying a gas spring to the flexible vessel to keep the oxygen compressed above the saturation pressure and, thus, in the liquid state; and (4) using heat leakage into the system for vaporizing the oxygen to be dispensed. In a typical prior system based on these principles, the flexible vessel is a metal bellows housed in a rigid tank, and the gas spring consists of pressurized helium in the tank volume surrounding the bellows. Unfortunately, the welds in the bellows corrugations are subject to fatigue, and, because bellows have large ullage, a correspondingly large fraction of the oxygen content cannot be expelled. In the proposed system, the flexible vessel would be a bladder made of a liquid- crystal polymer (LCP). (LCPs are strong and compatible with liquid oxygen.) In comparison with a metal bellows, a polymeric bladder would have less ullage and would weigh less. In experiments involving fatigue cycling at liquid-nitrogen temperatures, two LCPs were found to be suitable for this application.

Walker, David H.↗

High-Reynolds Number Active Blowing Semi-Span Force Measurement System Development

Recent wind-tunnel tests at the NASA Langley Research Center National Transonic Facility utilized high-pressure bellows to route air to the model for evaluating aircraft circulation control. The introduction of these bellows within the Sidewall Model Support System significantly impacted the performance of the external sidewall mounted semi-span balance. As a result of this impact on the semi-span balance measurement performance, it became apparent that a new capability needed to be built into the National Transonic Facility s infrastructure to allow for performing pressure tare calibrations on the balance in order to properly characterize its performance under the influence of static bellows pressure tare loads and bellows thermal effects. The objective of this study was to design both mechanical calibration hardware and an experimental calibration design that can be employed at the facility in order to efficiently and precisely perform the necessary loadings in order to characterize the semi-span balance under the influence of multiple calibration factors (balance forces/moments and bellows pressure/temperature). Using statistical design of experiments, an experimental design was developed allowing for strategically characterizing the behavior of the semi-span balance for use in circulation control and propulsion-type flow control testing at the National Transonic Facility.

Lynn, Keith C.↗

Mitigation of Silver Ion Loss from Solution by Polymer Coating of Metal Surfaces, Part IV

Ionic silver (Ag+) biocide is a leading candidate to provide residual microbial control in spacecraft potable water systems, but suffers from rapid concentration loss due to interactions with the metallic storage containers and tubing. One approach to resolve this problem is the coating of metal surfaces with an inert barrier film. In previous reports, we have described our investigations addressing Ag+ loss mitigation and adhesion performance of parylene barrier coatings on coupons of several metal alloys and 316Ltubing under static immersion. In such conditions, parylene-C and -AF4 coatings have shown excellent Ag+loss mitigation and mixed long-term adhesion performance, depending on parylene species and substrate surface chemistry/structure. In Part IV of this series, we report on our work to investigate the performance of parylene-C barrier coatings, under more challenging and realistic conditions, in order to evaluate potential suitability for use. The resilience and associated Ag+ loss with Parylene-C coating on½” (12.7 mm)316L tubing and fittings under medium-term immersion and repeated fitting dis/reassembly were investigated. Potential mechanical challenges to barrier coatings in spacecraft potable water systems were investigated, with two main focuses being identified: liquid flow/pressure cycling in tubing and cyclic operation of bellows in positive-expulsion storage tanks. Two corresponding testbeds for experimental characterization of coating performance were developed. In the Flow/Pressure Testbed System, Ag+ solution will be pumped through internally coated 316L tubing, with optional pressure cycling. In the Bellows Tank Testbed System, an internally coated edge-welded 316L bellows containing Ag+ solution will be cyclically extended and compressed, analogous to the operation of bellows tanks used for potable water storage and delivery on the International Space Station. The design and operation of these testbeds are described. Finally, the Ag+ adsorption and saturation behaviors of Kalrez and Viton, for potential use as seal materials in fittings and other connections, were characterized in limited experiments.

mitigation↗

Construction and testing of a gas-loaded, passive-control, variable-conductance heat pipe

A methanol heat pipe using nitrogen gas for temperature control has been constructed and tested. The system was run over a power ratio of 15 (2 to 30 watts) with the heat source near ambient temperature and with the heat sink at a nominal value of 32 F. Control was obtained with a metal bellows gas reservoir which was actuated by an internal liquid-filled bellows. The liquid bellows was pressurized by expanding liquid methanol which was contained in an auxiliary reservoir in the evaporator heater block. It was demonstrated that the temperature variation of the heat source was reduced from 36 F for the heat pipe with no control to 7 F with the actuated bellows control.

Depew, C. A.↗

Internally supported flexible duct joint

An internally supported, flexible duct joint for use in conducting fluids under relatively high pressures in systems where relatively large deflection angles must be accommodated is presented. The joint includes a flexible tubular bellows and an elongated base disposed within the bellows. The base is connected through radiating struts to the bellows near mid-portion and to each of the opposite end portions of the bellows through a pivotal connecting body. A motion-controlling linkage is provided for linking the connecting bodies, whereby angular displacement of the joint is controlled and uniformity in the instantaneous bend radius of the duct is achieved as deflection is imposed.

Kuhn, R. F., Jr.↗

Miniature Low-Mass Drill Actuated by Flextensional Piezo Stack

Recent experiments with a flextensional piezoelectric actuator have led to the development of a sampler with a bit that is designed to produce and capture a full set of sample forms including volatiles, powdered cuttings, and core fragments. The flextensional piezoelectric actuator is a part of a series of devices used to amplify the generated strain from piezoelectric actuators. Other examples include stacks, bimorphs, benders, and cantilevers. These devices combine geometric and resonance amplifications to produce large stroke at high power density. The operation of this sampler/drill was demonstrated using a 3x2x1-cm actuator weighing 12 g using power of about 10-W and a preload of about 10 N. A limestone block was drilled to a depth of about 1 cm in five minutes to produce powdered cuttings. It is generally hard to collect volatiles from random surface profiles found in rocks and sediment, powdered cuttings, and core fragments. Toward the end of collecting volatiles, the actuator and the bit are covered with bellows-shaped shrouds to prevent fines and other debris from reaching the analyzer. A tube with a miniature bellows (to provide flexibility) is connected to the bit and directs the flow of the volatiles to the analyzer. Another modality was conceived where the hose is connected to the bellows wall directly to allow the capture of volatiles generated both inside and outside the bit. A wide variety of commercial bellows used in the vacuum and microwave industries can be used to design the volatiles capture mechanism. The piezoelectric drilling mechanism can potentially be operated in a broad temperature range from about-200 to less than 450 C. The actuators used here are similar to the actuators that are currently baselined to fly as part of the inlet funnel shaking mechanism design of MSL (Mars Science Laboratory). The space qualification of these parts gives this drill a higher potential for inclusion in a future mission, especially when considering its characteristics of low mass, small size, low power, and low axial loads for sampling.

Sherrit, Stewart↗

Sequential-strip and sequential-disk filters

Filter senses increasing pressure drop and uses this to compress bellows. Compression of bellows stores energy in spring until predetermined pressure-drop level is reached. At this point, bellows and spring are released. Relaxation of spring is used to move a clean area of screen into position across fluid stream.

Winzen, J. P.↗

Design and testing of a passive, feedback-controlled, variable conductance heat pipe

A passive feedback system, which stabilizes the heat source temperature (T sub s) of a gas loaded heat pipe, was designed and tested. The control of T sub s is accomplished by an auxiliary liquid that senses the heat source and actuates a metal bellows system due to the liquid's thermal expansion. The movement of the bellows varies the gas reservoir volume and leads to a corresponding change of the condensation area of the heat pipe. With methanol as the heat pipe working fluid and perfluoro-n-pentane as the auxiliary liquid, the control capability was found to be T sub s = 31.5 + or - 1.5 C in a power range from 3 to 30 W, compared to T sub s = 33 + or - 3 C with methanol as auxiliary liquid. The change in T sub s was 35 + or - 5.5 C with the bellows held in the closed position.

Schlitt, K. R.↗

3-D Manipulator for Mass Spectrometer

Small mass-spectrometer specimens are positioned in three dimensions by manipulator that employs two bellows to provide vacuum seal and accommodate movement of specimen holder. Inner bellows and outer bellows accommodate vertical and horizontal motion, respectively. Y-axis movement is in and out of plane of page. Specimen-holder column is hollow so electrical wires can pass through it to specimen.

Cirner, J. C.↗

Low-Shock Pyrotechnic Actuator

Miniature 1-ampere, 1-watt pyrotechnic actuator enclosed in flexible metal bellows. Bellows confines outgassing products, and pyrotechnic shock reduction achieved by action of bellows, gas cushion within device, and minimum use of pyrotechnic material. Actuator inexpensive, compact, and lightweight.

Lucy, M. H.↗

Heat pipe thermal switch

A thermal switch for controlling the dissipation of heat between a body is described. The thermal switch is comprised of a flexible bellows defining an expansible vapor chamber for a working fluid located between an evaporation and condensation chamber. Inside the bellows is located a coiled retaining spring and four axial metal mesh wicks, two of which have their central portions located inside of the spring while the other two have their central portions located between the spring and the side wall of the bellows. The wicks are terminated and are attached to the inner surfaces of the outer end walls of evaporation and condensation chambers respectively located adjacent to the heat source and heat sink. The inner surfaces of the end walls furthermore include grooves to provide flow channels of the working fluid to and from the wick ends. The evaporation and condensation chambers are connected by turnbuckles and tension springs to provide a set point adjustment for setting the gap between an interface plate on the condensation chamber and the heat sink.

Wolf, D. A.↗

Fully redundant mechanical release actuator

A system is described for performing a mechanical release function exhibiting low shock. This system includes two pyrotechnic detents fixed mounted in opposing axial alignment within a cylindrical housing having two mechanical bellows. Two mechanical bellow assemblies, each having one end hermetically bonded to the housing and the other to the respective actuator pin extending from either end of the housing, ensure that all outgassing and contamination from the operation of the pyrotechnic devices will be contained within the housing and bellows. The pin on one end of the assembly is fixed mounted and supported, via a bolt or ball-and-socket joint so that when the charge corresponding to that pin ignites, the entire assembly will exhibit rectilinear movement, including the opposing pin providing the unlatching motion. The release detent pin is supported by a linear bearing and when its corresponding pyrotechnic charge ignites the pin is retracted within the housing producing the same unlatching motion without movement of the entire assembly, thus providing complete mechanical, electrical and pyrotechnic redundancy for the unlatching pin.

Lucy, Melvin H.↗

Damper Of Small Vibrations

Vibration damper has no rubbing parts. Thus eliminates even very small static frictional forces and therefore responds to and damps extremely low levels of vibration. Damper dissipates vibration by motion of piston in volume of silicone oil. Coaxial rigid shaft holds upper and lower bellows at constant length while piston vibrates up and down. Although volumes of upper and lower bellows change continually, total volume of bellows assembly stays same.

Davis, L. P.↗

Turbulent flow preasure drop in various He II transfer system components

Pressure drop experiments in highly turbulent He II flow were performed in flow loops driven by either a centrifugal pump or a single-stroke bellows pump. Pressure drops in straight tubing, coiled tubing, bellows sections, valves and Venturi flow meters were measured over a range of flow rates and temperatures. Our pressure drop data are in general agreement with classical fluid correlations when the He II normal component viscosity is used in calculating the Reynolds number. Cavitation and, in some cases, metastable superheating were observed in pressure drop measurements with Venturis in both centrifugal and bellows pump flow circuits.

Walstrom, P. L.↗

Improved Nutation Damper for a Spin-Stabilized Spacecraft

A document proposes an improved liquid- ring nutation damper for a spin-stabilized spacecraft. The improvement addresses the problem of accommodating thermal expansion of the damping liquid. Heretofore, the problem has been solved by either (1) filling the ring completely with liquid and accommodating expansion by attaching a bellows or (2) partially filling the ring and accepting the formation of bubbles. The disadvantage of (1) is that a bellows is expensive and may not be reliable; the disadvantage of (2) is that bubbles can cause fluid lockup and consequent loss of damping. In the improved damper, the ring would be nearly completely filled with liquid, and expansion would be accommodated, but not by a bellows. Instead, an escape tube would be attached to the ring. The escape tube would be positioned and oriented so that the artificial gravitation and the associated buoyant force generated by the spin of the spacecraft would cause the bubbles to migrate toward the tip of the tube. In addition, when the spacecraft was on the launch pad, the escape tube would be at the top of the ring, so that bubbles would rise into the tube.

Woodard, Mark A.↗

Calibration and Data Analysis of the MC-130 Air Balance

Design, calibration, calibration analysis, and intended use of the MC-130 air balance are discussed. The MC-130 balance is an 8.0 inch diameter force balance that has two separate internal air flow systems and one external bellows system. The manual calibration of the balance consisted of a total of 1854 data points with both unpressurized and pressurized air flowing through the balance. A subset of 1160 data points was chosen for the calibration data analysis. The regression analysis of the subset was performed using two fundamentally different analysis approaches. First, the data analysis was performed using a recently developed extension of the Iterative Method. This approach fits gage outputs as a function of both applied balance loads and bellows pressures while still allowing the application of the iteration scheme that is used with the Iterative Method. Then, for comparison, the axial force was also analyzed using the Non-Iterative Method. This alternate approach directly fits loads as a function of measured gage outputs and bellows pressures and does not require a load iteration. The regression models used by both the extended Iterative and Non-Iterative Method were constructed such that they met a set of widely accepted statistical quality requirements. These requirements lead to reliable regression models and prevent overfitting of data because they ensure that no hidden near-linear dependencies between regression model terms exist and that only statistically significant terms are included. Finally, a comparison of the axial force residuals was performed. Overall, axial force estimates obtained from both methods show excellent agreement as the differences of the standard deviation of the axial force residuals are on the order of 0.001 % of the axial force capacity.

Booth, Dennis↗

Mitigation of Silver Ion Loss from Solution by Polymer Coating of Metal Surfaces, Part IV

“Spacecraft potable water systems require a biocidal agent that effectively provides both immediate and residual disinfection over long periods of time. Ionic silver (Ag+) is a leading candidate for this application, but suffers from rapid concentration loss due to interactions with the metallic storage containers and tubing. In order to maintain biocidal efficacy in systems with long periods of dormancy and to reduce the required rate of Ag+ injection, it is necessary to develop alternative materials and coatings for certified metal alloys that significantly reduce the Ag+ loss.” In previous reports, we have described our investigations addressing Ag+ loss mitigation and adhesion performance of parylene barrier coatings on coupons of several metal alloys and 316L tubing under static immersion. In such conditions, parylene-C and AF4 coatings have shown excellent Ag+ loss mitigation performance, and mixed long-term adhesion performance, depending on parylene species and substrate surface chemistry/structure. In Part IV of this series, we begin to address the performance of parylene-C barrier coatings under more challenging and realistic conditions, in order to evaluate potential suitability in flight systems. Using two testbeds, we characterized coating performance under dynamic mechanical operation. In the Flow/Pressure Testbed System, Ag+ solution is pumped through internally coated 316L tubing, with optional pressure cycling. In the Bellows Tank Testbed System, an internally coated edge-welded 316L bellows containing Ag+ solution is cyclically extended and compressed, analogous to the operation of bellows tanks used for potable water storage and delivery on the International Space Station. Periodic determinations of Ag+ loss with testbed cycling/time and visual observation of the parylene-C coatings were conducted. In addition, we characterized parylene-C coating resilience and Ag+ loss with 316L tubing and multiple fitting types under long-term immersion and repeated fitting dis/reassembly.

Lance Dean Delzeit↗