Electron attachment to atomic fluorine in thermally ionized air
Electron attachment to atomic fluorine in thermally ionized air for application to reentry radio communications blackout
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Electron attachment to atomic fluorine in thermally ionized air for application to reentry radio communications blackout
Electron density probes for potential application to Apollo in-flight plasma sheath diagnostics in reentry radio blackout investigations
Planetary entry blackout, instrumentation and data reduction for lunation experiment, spacecraft communications system, and low noise transponder preamplifier
The RAM C-3 flight experiment was launched to study the problem of radiofrequency blackout at an entry velocity of 24,300 ft/sec. The flight is described, and data for the entry trajectory and environment, which include the effects of actual temperature measured the day of launch, are presented. An analysis of entry spacecraft motions was performed. This analysis included the determination of wind angles from measured accelerations and estimates of wind angles at high altitudes from gyro-measured rotation rates. The maximum wind angles were found to be less than 5 deg to the point of pitch-roll resonance where the total wind angle increased to 8.5 deg and the roll rate started decreasing. A plausible cause for the decrease in roll rate was shown to be a combination of trim angle and an offset center of gravity.
A table-top apparatus has recently been constructed at the NASA Glenn Research Center to investigate potential solutions for the radio-frequency communication blackout problem -- experienced by landing modules during high-speed atmospheric entry. This customized plasma chamber was designed to emulate Earth-based atmospheric entry plasmas with electron densities in the range of 10^16 m^-3 to 10^19 m^-3. The system makes use of a 40-kHz, perforated coaxial electrode pair to generate a disk-shaped, static plasma with an approximate diameter and thickness of 405 mm and 100 mm, respectively. A translatable Langmuir probe was employed to characterize the radial profile of electron temperature and density as a function the 40-kHz power (< 1 kW) and dry-nitrogen flow rate (< 160 SCCM).
Utility procedures for power system blackstart and restoration typically assume that energization decisions can be reliably communicated across the grid. In reality, the communications and control network would likely also be affected in power outages, such as those caused by extreme weather events or cyber-attacks. This paper studies the effect of damage to the power system communications and control infrastructure on restoration operations following a blackout. We model the communications infrastructure as a graph, overlaying the power grid, and imposing the requirement that every energized element in the power grid be observable from a control center. We expand on a specialized branch-and-bound algorithm from the literature to optimize the restoration process and devise an initialization heuristic and a rounding heuristic to improve solution speed. We perform numerical experiments on synthetic systems for Illinois and Texas with outages based on a solar flare or hurricane. We compare the results of our specialized branch-and-bound algorithm to the results from (i) the initialization heuristic alone, (ii) a variation of this heuristic that we use as a baseline, and (iii) the restoration optimization for the power system without communications constraints. Here, we find that damage to the communications infrastructure significantly increases the time required to re-energize the grid. Moreover, by simultaneously optimizing communications repairs and grid energization decisions, we are able to re-energize the grid significantly faster than if communications repairs and energization decisions were made independently or with partial coordination, motivating improvements to current industry practice.
The new energy paradigm is altering the current power grid trend from synchronous generator reliant system toward power-electronics-based distributed energy resources (DERs). The resilient operation of modern power grid is highly dependent upon cyber and physical reliable operation of DERs. Power grid resilience broadly refers to the ability of the grid to be robust to eventualities and singularities that may disrupt the continuity of reliable power flow. This could involve resilience related to the physical system but more recently, the focus on cyber resilience has been evolving rapidly especially given the burgeoning growth of distributed generation and power-electronics-based DERs under smart grid and given that such threats to reliable operation do not have to evolve localized to where the physical asset is. Commonly, in power grids dominated by DERS, control and energy management are structured at a multitime scale multilayer fashion: (i) primary control layer at microseconds time scale, (ii) secondary control layer at millisecond time scale, and (iii) tertiary control layer at seconds to minutes time scale. The cyber-related issues that may affect the power grid resilience can be introduced in through primary, secondary, and tertiary control layers. The failure of each of these control layers may impact the reliable and resilient operation of the overall network and cause widespread failures which leads to unintended blackouts. As such, this chapter focuses on cyber-related resilience issues in primary control layer, secondary control layer, tertiary control layer, wide area/utility control, and anomaly detection and resilient communication.
Reliable development of the power grid is an evolving concern for humanity due to extreme weather that frequently threatens power sector infrastructure. The state of Texas is a uniquely structured testbed for grid planners to study when looking for solutions to development, innovation, and overcoming such challenges. Because of its size and islanded structure, Texas is small enough to model, but big enough to matter. Texas is a global leader in energy production, energy consumption, and maintains an unusually diverse fuel mix. In addition, the state has experienced winter freezes, heat waves, wind storms, droughts and floods that have threatened power sector infrastructure or caused recent blackouts and calls for demand side conservation. One of the most devastating of these events was the North American winter storm, dubbed “Winter Storm Uri” by the Weather Channel, that froze the region in February 2021 and led to an extended power outage event that put the majority of Texan residents in darkness for days. While preparing to avoid such outage events in the future, various tools have been proposed to improve grid reliability, including energy efficiency, demand response, and distributed energy resources. An additional option would be to develop interregional transmission that connects the Texas grid to other national grids. To assess the merits of this idea, we developed a novel, universally-applicable and internationally-relevant framework to study how the Texas grid would evolve alongside access to various interregional ties. This method allows us to stress the synthetic grid structure and analyze how it would respond to the shock of a simulated winter storm event. Our method leverages open-source modeling tools, such as PowerGenome, pyGRETA, and GenX to synthesize unique zonal grid data, construct a consolidated network of model regions, and simulate different developmental pathways of capacity expansion and operational dispatch. We demonstrate our method with an analysis connecting the Electric Reliability Council of Texas (ERCOT), the grid that serves most of Texas, the Western Electricity Coordinating Council (WECC), the grid that serves the western half of the contiguous U.S., and the Eastern Interconnect, the grid that serves the eastern half of the contiguous U.S. Our results indicate that the cost-optimal capacity of interregional transmission connecting the ERCOT grid to other grids lies between 9–13 GW assuming baseline conditions. Building this amount of connecting capacity in one or multiple directions lowers the costs and emissions of development and operation by up to $16 billion and 257 million metric tonnes (MMT) respectively. Additionally, our results show that the interregional connections between ERCOT and other national grids reduce the amount of total load shed required through mild winter storm events. However, our results also show that there is a threshold of very extreme winter storm conditions, spanning multiple service areas, above which the connections exacerbate resource adequacy problems. Therefore, the results indicate that the connections need to be carefully planned alongside the rest of the grid infrastructure to avoid over-reliance on specific resources or technology options.
Extreme heat events have widespread effects on power systems, reducing available generation capacity, limiting transmission capabilities, and causing unusual demand patterns on the consumer side. As these combined effects expose bulk transmission systems to potential large-scale blackouts, utilities may be required to schedule and apply rotating outages, by temporarily and alternately disconnecting distribution substations to reduce overload. However, utilities lack mechanisms to inform these events, exacerbating the negative effects of heat waves on affected communities. This paper introduces a novel framework for scheduling rotating outages during heat waves while considering impacts on consumers’ safety. Instead of random sequential load shedding, we propose a methodology to rotate power outages considering a metric that quantifies the indoor overheating risk of groups of consumers during a power outage. The overheating risk is derived from a detailed building simulation using CityBES, where the buildings are modeled based on available data—use type, year built, floor area, number of stories, location—while presence of air conditioning and occupancy are calibrated from smart meter data. Based on the metric, an algorithm to schedule the rotating outages is applied to prioritize feeders for disconnection at each hour according to their overheating risk to meet a utility load reduction target. Applied to two substations and seven feeders in the Portland General Electric territory, the results show that this approach effectively leads to the lowest overheating risk during the resulting outage schedules, with an average 10.1% lower overheating compared to uninformed schedules.
Behind-the-meter storage (BTMS) systems - a viable method to minimize potential risk of blackout events and stabilize the grid - require a different type of cost-effective energy storage with excellent safety, ultra-long (>20 years) cycle life and reasonable energy density compared that of electric vehicles. To increase the energy density and reduce the cost of a long-term cyclable lithium-titanate-based cell, it is required to employ a critical-material-free high voltage cathode and an electrolyte with good electrochemical and transport properties. In this report the long-term electrochemical performance and behaviors of selected critical-material-free Li 4 Ti 5 O 12 (LTO)//LiNi 0.9 Mn 0.1 O 2 (LNMO) full cells for BTMS applications are evaluated and analyzed in the optimized voltage range of 1.4-2.7 V at 45 degrees C with different fluorinated carbonate-based electrolytes. The fluoroethylene carbonate (FEC)-based electrolyte cell shows the highest capacity retention of 57.9% and Coulombic efficiency (CE) of 99.96% after 1000 cycles, potentially attributed to a dense, homogenous and less resistive LiF-rich solid-electrolyte interphase (SEI) layer formed on the surface of LTO that may mitigate electrolyte decomposition and maintain relatively low cell impedance during cycling. The 3,3,3-fluoroethylmethyl carbonate (F-EMC)-based electrolyte cell, however, presents the worst performance with lower capacity and a sharp decrease of CE, due to unstable and non-uniform SEI formation and continuous oxidative electrolyte decomposition. This mechanistic understanding of cell aging behaviors and failure mechanisms with detailed analysis of surface chemistry and electrode morphology can guide design of new electrode chemistries and electrolyte formulations for the development of BTMS batteries.
Electric overloading conditions and contingencies put modern power systems at risk of voltage collapse and blackouts. Load shedding is crucial to maintain voltage stability for grid emergency control. However, the rule- or model-based schemes rely on accurate dynamic system models and face considerable challenges in adapting to various operating conditions and uncertain event occurrences. Here, to address these issues, this paper proposes a novel deep reinforcement learning (DRL)-based voltage stability control algorithm with automatic entropy adjustment (AEA) for grid emergency control. Various dynamic network components for complex system operations are modeled to construct the DRL environment. An off-policy soft actor-critic architecture is developed to maximize the expected reward and policy entropy simultaneously. The AEA mechanism is proposed to facilitate the policy maximum entropy procedure, and the proposed method can automatically provide effective discrete and continuous actions against various fault scenarios. Our approach accomplishes high sampling efficiency, scalability, and auto-adaptivity of the control policies under high uncertainties. Comparative studies with the existing DRL-based control methods in IEEE benchmarks indicate salient performance improvement of the proposed method for dynamic system emergency control.
Commutation failures represent a prevalent issue encountered in line-commutated-converter high voltage direct current (LCC-HVDC) systems. As the widespread deployment of HVDC systems continues, the risk associated with commutation failures increases, posing a growing threat to power grids due to their potential to trigger severe consequences, including cascading failures and widespread blackouts. This research paper aims to address the significant issue of commutation failure within direct current (DC) systems through advocating for the use of resistive-type Superconducting Fault Current Limiters (R-SFCLs). To substantiate the efficacy of this proposed strategy, an array of simulations are executed using the PSCAD/EMTDC software. This comprehensive study investigates the performance characteristics of R-SFCLs configured with varying resistance values, scrutinizing their response under diverse fault resistance scenarios and distinct fault initiation times within the LCC-HVDC system. The outcomes of these simulations are that SFCLs confer significant advantages for mitigating commutation failures, surpassing traditional mitigation methods in terms of effectiveness. Consequently, SFCLs emerge as an optimal solution to prevent commutation failures in the HVDC systems.
Risk-informed decision-making requires a probabilistic assessment of the likelihood of success of control action, given the system status. This paper presents a systematic state transition modeling approach integrating dynamic probabilistic risk assessment with a decision-making process using a dynamic Bayesian network (DBN) coupled with functional modeling. A functional model designed with multilevel flow modeling (MFM) technique was used to build a system state structure inferred by energy, mass, and information flow so that one can verify the developed model with respect to system functionality. The MFM model represents the causal relationship among the nodes, which captures the structure of process parameters and control units. Each node may have multiple possible states, and the DBN structured by the MFM model represents the time-domain transitions among the defined states. Furthermore, the MFM-DBN integrated state transition modeling is a white-box approach that allows one to draw the system's risk profile by updating the system states and supports the decisions probabilistically with physical inference. An example of a simple heating system has been used to illustrate this process, including decision-making support based on quantitative risk profile. For demonstrating its applicability to a complex system operational decision making, a case study of station blackout accident scenario leading to the seal loss of coolant accident in a nuclear power plant is presented. The proposed approach effectively provided the risk profile along time for each option so that the operators can make the best decision, which minimizes the plant risk.
Natural disasters often result in failures of transportation network components and blackouts that imperil the wellbeing of vulnerable populations. In response to these events, resilience hubs have been proposed as a pre-disaster planning strategy to improve access to critical services. This paper introduces an optimization-based approach to locate and configure electric power-generating resilience hubs considering the possibility of failures in transportation and electric power systems. The model's objective is to identify hub locations and configurations that maximize transportation accessibility to the hubs and maximize the satisfaction of basic energy needs through hub-generated electric power. Besides a budget constraint, the model accounts for limits on the levels of hub energy generation vis-à-vis community energy demands, and on the transportation network distance of communities to hubs. Three heuristics are presented for the proposed planning problem. The first heuristic is a genetic algorithm (GA) with problem-specific solution generation procedures. The other two heuristics implement greedy search techniques. Numerical experiments were conducted, using data from rural Puerto Rico, to illustrate the application of the proposed model and heuristics, and examine their performance. In the numerical experiments, the GA heuristic found better solutions than the greedy heuristics. Additionally, design solutions consisting of spatially dispersed hubs with low energy generation capacity were better than solutions with spatially concentrated high-capacity hubs. Lastly, across a wide range of hub demand scenarios, only a small number of candidate hub locations consistently ranked among the best locations for establishing a hub.
The synchronized operation of power generators is the foundation of electric power network stability and a key to the prevention of undesired power outages and blackouts. Here, we derive the conditions that guarantee synchronization in power networks with inherent generator heterogeneity when subjected to small perturbations, and perform a parametric sensitivity analysis to understand synchronization with varied types of generators. As inverter-based resources, which are the primary interfacing technology for many renewable sources of energy, have supplanted synchronous generators in ever growing numbers, the center of attention on associated integration challenges have resided primarily on the role of declining system inertia. Our results instead highlight the critical role of generator damping in achieving a stable state of synchronization. Additionally, we report the feasibility of operating interconnected electric grids with up to 100% power contribution from inverter-based renewable generation technologies. Our study has important implications as it sets the basis for the development of advanced control architectures and grid optimization methods that ensure synchronization and further pave the path towards the decarbonization of the electric power sector.
Reducing the duration and frequency of blackouts in remote communities poses an engineering challenge for grid operators. Outage effects can also be mitigated locally through microgrids. This paper develops a systematic procedure to account for these challenges by creating microgrids prioritizing high value assets within vulnerable communities. Nighttime satellite imagery is used to identify vulnerable communities. Using an asset classification and rating system, multi-asset clusters within these communities are prioritized. Infrastructure data, geographic information systems, satellite imagery, and spectral clustering are used to form and rank microgrid candidates. A microgrid sizing algorithm is included to guide through the microgrid design process. Finally, an application of the methodology is presented using real event, location, and asset data.
Accident tolerant fuels (ATFs) are new nuclear fuels developed in response to the accident at the Fukushima power station in March 2011. The goal of ATFs is to withstand accident scenarios through better performance compared to currently employed fuels (e.g., small-scale hydrogen generation). This paper targets a method for evaluating and comparing ATF performance from a probabilistic risk assessment (PRA) perspective by employing a newly developed combination of event trees and dynamic PRA methods. Compared to classical PRA methods based on event trees and fault trees, dynamic PRA can evaluate with higher resolution the safety impacts of physics dynamics and the timing/sequencing of events on the accident progression without the need to introduce overly conservative modeling assumptions and success criteria. In this paper, we analyze the impact on the accident progression of three different cladding configurations for two initiating events [a large break loss-of-coolant accident (LB-LOCA) and a station blackout (SBO)] by employing dynamic PRA methods. The goal is to compare the safety performance of ATFs (FeCrAl and Cr-coated cladding) and the currently employed Zr-based clad fuel. We employ two different strategies. The first focuses on the identification of success criteria discrepancies between the accident sequences generated by the classical PRA model and the set of simulation runs generated by dynamic PRA using ATF. The second one, on the other hand, directly uses dynamic PRA to evaluate the impact of timing of events (e.g., recovery actions) on accident progression. In conclusion, by applying these methods to the LB-LOCA and SBO initiating events, we show how dynamic PRA methods can provide analysts with detailed and quantitative information on the safety impact of ATFs.
A SAM system-level model of a generic stable salt reactor has been developed to investigate thermal-hydraulic behavior and safety performance under steady and transient conditions. The model integrates information generated from a reactor physics analysis using PROTEUS and PERSENT, and a computation fluid dynamics (CFD) analysis using STAR-CCM+. A loose, iterative coupling scheme between PROTEUS and SAM is implemented to calculate the equilibrium power and temperature distributions in the steady-state critical core condition. The converged steady-state model is then used in PERSENT to calculate the four reactivity feedback temperature coefficients (Doppler, fuel density, coolant density, and core radial expansion) and kinetic parameters that are needed in SAM to model the temperature feedback effects in transient simulations. Within the fully enclosed liquid fuel pins, natural convection is the dominant heat transfer mechanism. The STAR-CCM+ model of the fuel pin considers conjugate heat transfer from the liquid fuel salt to the pin cladding and external reactor coolant. The CFD results of the axial and radial temperature profiles are used to empirically determine an effective fuel salt thermal conductivity in the SAM fuel pin model so that the temperatures predicted by the SAM model match as closely as possible the CFD results. In the central region of the fuel pin, the effective thermal conductivity is as high as similar to 60 times the physical fuel salt thermal conductivity. The whole-plant SAM model is then used to simulate an unprotected station blackout transient. The results of this simulation showed that the large negative fuel axial expansion reactivity feedback reduces fission power to similar to 2.4% nominal power. The core is cooled by natural circulation, which removes heat in the core to the emergency heat removal system, and ultimately, to the ambient. However, peak fuel salt and cladding temperatures can potentially reach as high as 1500 K, albeit briefly, if the shutdown mechanism fails to operate.