Search NASA⌕ Search

SEARCH · Search NASA

Results for “bubble pump”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Microgravity Liquid-Gas Two-Phase Flow: Review of Pressure Drop and Heat Transfer Correlations and Guidelines for Equipment Operability

In this report we have catalogued the flow regimes observed in microgravity, summarized correlations for the pressure drop and rate of heat transfer that are commonly used, and discuss the validation of a few correlations from available experimental results. Two-phase flow through some specific components such as bends, tees, filters and pumps are discussed from a physical perspective to guide the designer on how reduced gravity might affect their performance. Phase separation in zero gravity is addressed through the behavior and basic design concepts for devices based on passive centrifugal action, capillary forces, gas extraction through a membrane installed in a channel wall and the use of a syringe with a perforated piston to remove bubbles from small liquid volumes. We address the common instabilities that develop in flow loops owing exclusively to the two-phase nature of the flow, e.g., Ledinegg instability and concentration waves. Finally we briefly review flow metering and gauging; two-phase flow through porous media, where pressure drop and flow regime map correlations in zero-g are a current research topic; and basic operation principles of heat pipes and capillary pumped loops.

liquid-gas↗

Investigation of Turbulent Tip Leakage Vortex in an Axial Water Jet Pump with Large Eddy Simulation

Detailed steady and unsteady numerical studies were performed to investigate tip clearance flow in an axial water jet pump. The primary objective is to understand physics of unsteady tip clearance flow, unsteady tip leakage vortex, and cavitation inception in an axial water jet pump. Steady pressure field and resulting steady tip leakage vortex from a steady flow analysis do not seem to explain measured cavitation inception correctly. The measured flow field near the tip is unsteady and measured cavitation inception is highly transient. Flow visualization with cavitation bubbles shows that the leakage vortex is oscillating significantly and many intermittent vortex ropes are present between the suction side of the blade and the tip leakage core vortex. Although the flow field is highly transient, the overall flow structure is stable and a characteristic frequency seems to exist. To capture relevant flow physics as much as possible, a Reynolds-averaged Navier-Stokes (RANS) calculation and a Large Eddy Simulation (LES) were applied for the current investigation. The present study reveals that several vortices from the tip leakage vortex system cross the tip gap of the adjacent blade periodically. Sudden changes in local pressure field inside tip gap due to these vortices create vortex ropes. The instantaneous pressure filed inside the tip gap is drastically different from that of the steady flow simulation. Unsteady flow simulation which can calculate unsteady vortex motion is necessary to calculate cavitation inception accurately even at design flow condition in such a water jet pump.

Hah, Chunill↗

Development of a Prototype Algal Reactor for Removing CO2 from Cabin Air

Controlling carbon dioxide in spacecraft cabin air may be accomplished using algal photobioreactors (PBRs). The purpose of this project was to evaluate the use of a commercial microcontroller, the Arduino Mega 2560, for measuring key phot~ioreactor variables: dissolved oxygen, pH, temperature, light, and carbon dioxide. The Arduino platform is an opensource physical computing platform composed of a compact microcontroller board and a C++/C computer language (Arduino 1.0.5). The functionality of the Arduino platform can be expanded by the use of numerous add-ons or 'shields'. The Arduino Mega 2560 was equipped with the following shields: datalogger, BNC shield for reading pH sensor, a Mega Moto shield for controlling CO2 addition, as well as multiple sensors. The dissolved oxygen (DO) probe was calibrated using a nitrogen bubbling technique and the pH probe was calibrated via an Omega pH simulator. The PBR was constructed using a 2 L beaker, a 66 L box for addition of CO2, a micro porous membrane, a diaphragm pump, four 25 watt light bulbs, a MasterFiex speed controller, and a fan. The algae (wild type Synechocystis PCC6803) was grown in an aerated flask until the algae was dense enough to used in the main reactor. After the algae was grown, it was transferred to the 2 L beaker where CO2 consumption and O2 production was measured using the microcontroller sensor suite. The data was recorded via the datalogger and transferred to a computer for analysis.

Patel, Vrajen↗

Self-Calibrating, Variable-Flow Pumping System

Pumping system provides accurate, controlled flows of two chemical liquids mixed in spray head and react to form rigid or flexible polyurethane or polyisocyanurate foam. Compatible with currently used polyurethane-based coating materials and gas-bubble-forming agents (called "blowing agents" in industry) and expected to be compatible with materials that used in near future. Handles environmentally acceptable substitutes for chlorofluorocarbon foaming agents.

Walls, Joe T.↗

Microfluidic Biochip Design

As humans prepare for the exploration of our solar system, there is a growing need for miniaturized medical and environmental diagnostic devices for use on spacecrafts, especially during long-duration space missions where size and power requirements are critical. In recent years, the biochip (or Lab-on-a- Chip) has emerged as a technology that might be able to satisfy this need. In generic terms, a biochip is a miniaturized microfluidic device analogous to the electronic microchip that ushered in the digital age. It consists of tiny microfluidic channels, pumps and valves that transport small amounts of sample fluids to biosensors that can perform a variety of tests on those fluids in near real time. It has the obvious advantages of being small, lightweight, requiring less sample fluids and reagents and being more sensitive and efficient than larger devices currently in use. Some of the desired space-based applications would be to provide smaller, more robust devices for analyzing blood, saliva and urine and for testing water and food supplies for the presence of harmful contaminants and microorganisms. Our group has undertaken the goal of adapting as well as improving upon current biochip technology for use in long-duration microgravity environments. In addition to developing computational models of the microfluidic channels, valves and pumps that form the basis of every biochip, we are also trying to identify potential problems that could arise in reduced gravity and develop solutions to these problems. One such problem is due to the prevalence of bubbly sample fluids in microgravity. A bubble trapped in a microfluidic channel could be detrimental to the operation of a biochip. Therefore, the process of bubble formation in microgravity needs to be studied, and a model of this process has been developed and used to understand how bubbles develop and move through biochip components. It is clear that some type of bubble filter would be necessary in Space, and several bubble filter designs are being evaluated.

Panzarella, Charles↗

Grout long radius flow testing to support Saltstone disposal Unit 5 design

The Saltstone Facility, located within the Savannah River Site (SRS) near Aiken, South Carolina, consists of two facility segments: The Saltstone Production Facility (SPF) and the Saltstone Disposal Facility (SDF). The SPF receives decontaminated legacy low level sodium salt waste solution that is a byproduct of prior nuclear material processing. The salt solution is mixed with cementitious materials to form a grout slurry known as “Saltstone”. The grout is pumped to the SDF where it is placed in a Saltstone Disposal Unit (SDU) to solidify. SDU 6 is referred to as a “mega vault” and is currently in the design stage. The conceptual design for SDU 6 is a single cell, cylindrical geometry approximately 114.3 meters in diameter by 13.1 meter high and is larger than previous cylindrical SDU designs, 45.7 meters in diameter by 7.01 meters high (30 million gallons versus 2.9 million gallons of capacity). Saltstone slurry will be pumped into the new waste disposal unit through roof openings at a projected flow rate of about 34.1 cubic meters per hour. Nine roof openings are included in the design to discharge material into the SDU with an estimated grout pour radius of 22.9 to 24.4 meters and initial drop height of 13.1 meters. The conceptual design for the new SDU does not include partitions to limit the pour radius of the grout slurry during placement other than introducing material from different pour points. This paper addresses two technical issues associated with the larger diameter of SDU 6; saltstone flow distance in a tank 114.3 meters in diameter and quality of the grout. A long-radius flow test scaled to match the velocity of an advancing grout front was designed to address these technology gaps. The emphasis of the test was to quantify the flow distance and to collect samples to evaluate cured properties including compressive strength, porosity, density, and saturated hydraulic conductivity. Two clean cap surrogate mixes (saltstone premix plus water) were designed to simulate slurry with the reference saltstone rheology and a saltstone with extra water from the process flushing operation. Long-radius flow tests were run using approximately 4.6 cubic meters of each of these mixes. In both tests the pump rate was 0.063 liters/second (1 gpm). A higher pump rate, 0.19 liters/second (3 gpm), was used in a third long-radius flow test. The angle of repose of the grout wedges increased as a function of time in all three tests. The final angles of repose were measured at 3.0º, 2.4º, and 0.72º. The pump rate had the largest effect on the radial flow distance and slope of the grout surface. The slope on the pour placed at 0.19 liters/second (3 gpm) was most representative of the slope on the grout currently being pumped into SDU 2 which is estimated to be 0.7º to 0.9º. The final grout heights at 1/3 of a meter from the discharge point were 115, 105, and 38 cm. Entrapped air (≥ 0.25 cm bubbles) was also observed in all of the mixes. The entrapped air appeared to be released from the flows within about 3.1 meters (10 feet) of the discharge point. The bleed water was clear but had a thin layer of floating particulates. The bleed water should be retrievable by a drain water collection system in SDU 6 assuming the system does not get clogged. Layering was observed and was attributed to intervals when the hopper was being cleaned. Heat from the hydration reactions was noticeable to the touch.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Module for Oxygenating Water without Generating Bubbles

A module that dissolves oxygen in water at concentrations approaching saturation, without generating bubbles of oxygen gas, has been developed as a prototype of improved oxygenators for water-disinfection and water-purification systems that utilize photocatalyzed redox reactions. Depending on the specific nature of a water-treatment system, it is desirable to prevent the formation of bubbles for one or more reasons: (1) Bubbles can remove some organic contaminants from the liquid phase to the gas phase, thereby introducing a gas-treatment problem that complicates the overall water-treatment problem; and/or (2) in some systems (e.g., those that must function in microgravity or in any orientation in normal Earth gravity), bubbles can interfere with the flow of the liquid phase. The present oxygenation module (see Figure 1) is a modified version of a commercial module that contains >100 hollow polypropylene fibers with a nominal pore size of 0.05 m and a total surface area of 0.5 m2. The module was originally designed for oxygenation in a bioreactor, with no water flowing around or inside the tubes. The modification, made to enable the use of the module to oxygenate flowing water, consisted mainly in the encapsulation of the fibers in a tube of Tygon polyvinyl chloride (PVC) with an inside diameter of 1 in. (approx.=25 mm). In operation, water is pumped along the insides of the hollow fibers and oxygen gas is supplied to the space outside the hollow tubes inside the PVC tube. In tests, the pressure drops of water and oxygen in the module were found to be close to zero at water-flow rates ranging up to 320 mL/min and oxygen-flow rates up to 27 mL/min. Under all test conditions, no bubbles were observed at the water outlet. In some tests, flow rates were chosen to obtain dissolved-oxygen concentrations between 25 and 31 parts per million (ppm) . approaching the saturation level of approx.=35 ppm at a temperature of 20 C and pressure of 1 atm (approx.=0.1 MPa). As one would expect, it was observed that the time needed to bring a flow of water from an initial low dissolved-oxygen concentration (e.g., 5 ppm) to a steady high dissolved-oxygen concentration at or near the saturation level depends on the rates of flow of both oxygen and water, among other things. Figure 2 shows the results of an experiment in which a greater flow of oxygen was used during the first few tens of minutes to bring the concentration up to approx.=25 ppm, then a lesser flow was used to maintain the concentration.

Gonzalez-Martin, Anuncia↗

Influence of a strong longitudinal magnetic field on laser wakefield acceleration

Optimization of the beam quality and electronic trapped charge in the cavity are key issues of laser wake field acceleration. The effect of an initially applied uniform magnetic field, parallel to the direction of propagation of the pump pulse, on the laser wakefield is explored. First, an analytic model for the laser wakefield is built up in the case when such an external magnetic field is applied. Then, simulations are performed with a 3D quasi-cylindrical particle in cell code in the blowout (or bubble) regime. Transverse currents are generated at the rear of the bubble which amplify the longitudinal magnetic field. For several plasma and laser parameters, the wake shape is altered and trapping can be reduced or cancelled by the magnetic field. When considering optical injection, and when two counterpropagating waves interact with a rather high plasma density, trapping is not affected by the magnetic field. In this range of plasma and laser parameters, it is shown that the longitudinal magnetic field can reduce or even prevent self-injection and enhance beam quality.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Integrated Molten Salt Reactor Modeling Capabilities in NEAMS Thermal Hydraulics Tools

The DOE neams program supports a full range of computational thermal fluids analysis capabilities and code developments for a broad range of advanced reactor concepts. The research and development approach under the thermal fluids technical area synergistically combines three length and time scales in a hierarchical multi-scale approach. To enable multi-scale thermal fluids capability using these codes, a key joint effort has been underway to develop an integrated system- and engineering-scale thermal fluids analysis capability, through integration of SAM and Pronghorn codes, both based on the MOOSE framework. This report summarizes recent advances in developing an integrated system- and engineering-scale modeling capability for the msr concept, which has gained significant interest in recent years. A consistent framework was established by coupling Pronghorn and SAM through the Saline interface, with thermophysical properties provided by the Molten Salt Thermal Property Database (MSTDB-TP). Further improvements were made to the coupling schemes and domain-overlapping strategies, enhancing the stability and robustness of multi-code simulations. Verification and validation efforts demonstrate the accuracy of this integration across a range of benchmark problems, including one-dimensional heated pipe flows, three-dimensional natural convection loops with evolving isotopic compositions, and \gls{msre} demonstration cases. Within Pronghorn, new capabilities were introduced to model corrosion and noble-metal plating phenomena, supported by an extended thermal-hydraulics framework and refined turbulence treatments. To capture two-phase flow behavior, a multiphase Euler–Euler model was implemented in Pronghorn, including advanced closure relations, high-resolution advection techniques, and capillary force reconstruction. Preliminary verification cases confirm the fidelity of the approach, while planned validation efforts target canonical multiphase benchmarks and application to msr components such as the msre pump bowl. Finally, updates to SAM’s msr mass transfer modeling were extended to consider noble gas migration into porous structures like graphite. The point kinetics model was updated to include reactivity feedback contributions from any defined species, such as xenon. The gas transport model was expanded for applicability to gas mixtures, bubble efflux phenomena, and species transport between liquid and gas phases. A selection of multi-scale Sherwood number correlations from MOSCATO/NekRS and multi-phase correlations from literature have been added for improved accuracy in calculating mass transfer coefficients. A companion effort on developing system-level redox corrosion has also been incorporated into SAM. Collectively, these enhancements strengthen the predictive capability of SAM and Pronghorn for simulating MSR thermal-hydraulics, corrosion, multiphase behavior, and fission-product transport, providing a more complete toolset for design, safety analysis, and licensing support of next-generation \gls{msr}s.

42 - ENGINEERING↗

Experimental investigation of the influence of drainage condition on change in saturation of sheared sand

Here, this paper investigates the validity of the interpretation of results from testing saturated axisymmetric triaxial compression (ATC) sand specimens utilising three-dimensional (3D) synchrotron micro-computed tomography (SMT) to probe localised events that are completely missed or misinterpreted when analysing ATC measurements based on global standard measurements. Drained and undrained experiments were conducted at low and high back-pressures (BPs) coupled with multiple in situ 3D SMT to acquire high-resolution scans of the specimens at different axial strains. Specimens tested under low BP exhibited a large pore air volume change, which was not detected by the pump system that represents standard volume measurement. The increase in air volume caused a significant reduction in the degree of saturation leading to a possible transition from saturated to partially saturated constitutive behaviour. Undrained experiments exhibited a significant volume change contrary to the assumption of negligible volumetric strain for saturated undrained experiments. Air bubbles within the shear band for drained and undrained low-BP specimens showed opposite capillary pressure responses, increased for drained and decreased for undrained cases, due to the variation in the mechanism by which each of the two experiments predominantly counters the volume expansion within the shear band.

capillary pressure↗

Dynamics of cavitating cascades

The unsteady dynamics of cavitating cascades and inducer pumps were studied with a view to understanding (and possibly predicting) the dynamic characteristics of these devices. The chronology of the research is summarized as well as the final conculsions for each task. The construction of a dynamic pump test facility and its use in making experimental measurements of the transfer function is described as well as tests conducted using a scale model of the low pressure liquid oxygen turbopump inducer in the shuttle main engine. Auto-oscillation and unsteady inlet flow characteristics are discussed in addition to blade cavity influence and bubbly cavitation.

Brennen, C. E.↗

Coherent Manipulation of Single Electrons with Optical Photons in Condensed Helium-4

Single electrons are one of the simplest quantum objects in nature. In free space or conventional materials, single electrons hardly interact with optical (ultraviolet-visible-infrared) photons, so their quantum states cannot be easily manipulated by optics. Here, a notable exception is is theoretically demonstrated: A single electron in condensed helium-4 can be self-confined in a nanometric bubble of 1 to 2 nm radius and resonantly interact with mid-infrared photons of 3 to 12 μm wavelength. A femtosecond laser can drive the electron into Rabi oscillations and prepare it onto arbitrary superposition states between the ground and excited states. After the laser pulse, the electron bubble can exhibit remarkable nonequilibrium quantum dynamics and evolve toward various final states with various lifetimes. These processes are accompanied with intense phonon radiation.

36 MATERIALS SCIENCE↗

Time Domain Thermoreflectance and Photodeflection Signatures of He Bubbles in Metals

The mechanical properties of the steel and weldments for different components are affected by the formation of helium bubbles as a result of tritium decay. Therefore, periodic analyses of metals exposed to tritium gas are conducted to determine structural defects and temporal damage from tritium gas decay and He precipitation. Transmission electron microscopy (TEM) and autoradiography are the current analytical methods for the evaluation of metal damage. These methods are functional after several years of damage to the crystal lattice where 3 He bubble formation damage can be seen with TEM. New analytical methods that can assess the damage to the crystal lattice early during the exposure to tritium are highly sought to ascertain the effects of material processing and tritium interactions. Further, simple sample preparation, compared to TEM, at a significantly reduced cost is highly desirable. A pump-probe laser technique using a femtosecond laser has been demonstrated to measure the thermal diffusivity of different materials. The time domain thermoreflectance laser setup can provide thermal diffusivity and phonon lifetime, which can be correlated with lattice damage. This advanced nonlinear optical technique will enable measurements of nanostructure damage in the metal before and after tritium exposure within a year. This report discusses current efforts in the design and development of the technique and the application to material characterization.

36 MATERIALS SCIENCE↗

Time Domain Thermoreflectance and Photodeflection Signatures of He Bubbles in Metals

The mechanical properties of the steel and weldments for different components are affected by the formation of helium bubbles as a result of tritium decay. Therefore, periodic analyses of metals exposed to tritium gas are conducted to determine structural defects and temporal damage from tritium gas decay and He precipitation. Transmission electron microscopy (TEM) and autoradiography are the current analytical methods for the evaluation of metal damage. These methods are functional after several years of damage to the crystal lattice where 3He bubble formation damage can be seen with TEM. New analytical methods that can assess the damage to the crystal lattice early during the exposure to tritium are highly sought to ascertain the effects of material processing and tritium interactions. Further, simple sample preparation, compared to TEM, at a significantly reduced cost is highly desirable. A pump-probe laser technique using a femtosecond laser has been demonstrated to measure the thermal diffusivity of different materials. The time domain thermoreflectance (TDTR) laser setup can provide thermal diffusivity and phonon lifetime, which can be correlated with lattice damage. This advanced nonlinear optical technique will enable measurements of nanostructure damage in the metal before and after tritium exposure within a year. This report discusses current efforts in the design and development of the technique and the application to material characterization.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Definition of two-phase flow behaviors for spacecraft design

Two-phase flow, thermal management systems are currently being considered as an alternative to conventional, single phase systems for future space missions because of their potential to reduce overall system mass, size, and pumping power requirements. Knowledge of flow regime transitions, heat transfer characteristics, and pressure drop correlations is necessary to design and develop two-phase systems. A boiling and condensing experiment was built in which R-12 was used as the working fluid. A two-phase pump was used to circulate a freon mixture and allow separate measurements of the vapor and liquid flow streams. The experimental package was flown five times aboard the NASA KC-135 aircraft which simulates zero-g conditions by its parabolic flight trajectory. Test conditions included stratified and annual flow regimes in 1-g which became bubbly, slug, or annular flow regimes on 0-g. A portion of this work is the analysis of adiabatic flow regimes. The superficial velocities of liquid and vapor have been obtained from the measured flow rates and are presented along with the observed flow regimes.

Reinarts, Thomas R.↗

Gas Retention, Gas Release, and Fluidization of Spherical Resorcinol-Formaldehyde (sRF) Ion Exchange Resin

The Low-Activity Waste Pretreatment System (LAWPS) is being developed to provide treated supernatant liquid from the Hanford tank farms directly to the Low-Activity Waste (LAW) Vitrification Facility at the Hanford Tank Waste Treatment and Immobilization Plant. The design and development of the LAWPS is being conducted by Washington River Protection Solutions, LLC. A key process in LAWPS is the removal of radioactive Cs from LAW liquids using ion exchange (IX) columns filled with spherical resorcinol-formaldehyde (sRF) resin. When loaded with radioactive Cs, radiolysis of water in the LAW liquid will generate hydrogen gas. In normal operations, the generated hydrogen is expected to remain dissolved in the liquid and be continuously removed by liquid flow. One accident scenario being evaluated is the loss of liquid flow through the sRF resin bed after it has been loaded with radioactive Cs and hydrogen gas is being generated by radiolysis. For an accident scenario with a loss of flow, hydrogen gas can be retained within the IX column both in the sRF resin bed and below the bottom screen that supports the resin within the column, which creates a hydrogen flammability hazard. Because there is a potential for a large fraction of the retained hydrogen to be released over a short duration as a gas release event, there is a need to quantify the size and rate of potential gas release events. Due to the potential for a large, rapid gas release event, an evaluation of mitigation methods to eliminate the hydrogen hazard is also needed. One method being considered for mitigating the hydrogen hazard during a loss of flow accident is to have a secondary flow system, with two redundant pumps operating in series, that re-circulates liquid upwards through the bed and into a vented break tank where hydrogen gas is released from the liquid and removed by venting the headspace of the break tank. The mechanism for inducing release of gas from the sRF bed is to fluidize the bed, which should allow retained bubbles to rise and be carried to the break tank. Currently, neither the ability of fluidizing a settled sRF bed to release gas nor the quantity of hydrogen gas that can be retained and the corresponding potential for large, rapid gas release events has been tested and evaluated. Accordingly, the purpose of this study was to conduct experiments and develop models that evaluate the ability of a re-circulating flow system to fluidize an sRF resin bed as a method to release retained hydrogen gas and maintain hydrogen gas retention at low levels, thereby avoiding conditions where hydrogen gas poses a flammability hazard. The purpose of the study was also to determine if effective hydrogen gas release would occur using a single constant fluidization velocity, because this is the most simple safety system to implement, for the range of fluid and sRF resin conditions anticipated in the column (because a velocity that is effective for one fluid/resin pair can be ineffective for different resin/fluid pairs). Finally, the study also included quantifying the volume of gas that can be retained in an sRF bed and the behavior of spontaneous, rather than fluidization-induced, gas release events.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Capillary-Pumped Heat-Transfer Loop

New type of capillary-pumped heat-transfer loop primes itself at startup. Removes substantial quantities of heat like that generated by people and equipment in rooms and vehicles. Creates continuous path for its working fluid; both vapor and liquid move in same direction. Key element in operation of loop is formation of slugs of liquid, condensed from vapor and moved along loop by vapor bubbles before and after it. Both evaporator and condenser contain axial arteries carrying water. Heat entering evaporator from heat source provides energy for transport of fluid and heat. Dimensions in inches.

Source record↗

Portable Microleak-Detection System

The figure schematically depicts a portable microleak-detection system that has been built especially for use in testing hydrogen tanks made of polymer-matrix composite materials. (As used here, microleak signifies a leak that is too small to be detectable by the simple soap-bubble technique.) The system can also be used to test for microleaks in tanks that are made of other materials and that contain gases other than hydrogen. Results of calibration tests have shown that measurement errors are less than 10 percent for leak rates ranging from 0.3 to 200 cm3/min. Like some other microleak-detection systems, this system includes a vacuum pump and associated plumbing for sampling the leaking gas, and a mass spectrometer for analyzing the molecular constituents of the gas. The system includes a flexible vacuum chamber that can be attached to the outer surface of a tank or other object of interest that is to be tested for leakage (hereafter denoted, simply, the test object). The gas used in a test can be the gas or vapor (e.g., hydrogen in the original application) to be contained by the test object. Alternatively, following common practice in leak testing, helium can be used as a test gas. In either case, the mass spectrometer can be used to verify that the gas measured by the system is the test gas rather than a different gas and, hence, that the leak is indeed from the test object.

Rivers, H. Kevin↗