Search NASA⌕ Search

SEARCH · Search NASA

Results for “calibration interferometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Broadband Stability of the Habitable Zone Planet Finder Fabry–Pérot Etalon Calibration System: Evidence for Chromatic Variation

The comblike spectrum of a white light–illuminated Fabry–Pérot etalon can serve as a cost-effective and stable reference for precise Doppler measurements. Understanding the stability of these devices across their broad (hundreds of nanometers) spectral bandwidths is essential to realizing their full potential as Doppler calibrators. However, published descriptions remain limited to small bandwidths or short time spans. We present an ∼6 month broadband stability monitoring campaign of the Fabry–Pérot etalon system deployed with the near-infrared Habitable Zone Planet Finder (HPF) spectrograph. We monitor the wavelengths of each of ∼3500 resonant modes measured in HPF spectra of this Fabry–Pérot etalon (free spectral range = 30 GHz, bandwidth = 820–1280 nm), leveraging the accuracy and precision of an electro-optic frequency comb reference. These results reveal chromatic structure in the Fabry–Pérot mode locations and their evolution with time. We measure an average drift on the order of 2 cm s{sup –1} day{sup −1}, with local departures up to ±5 cm s{sup –1} day{sup −1}. We discuss these behaviors in the context of the Fabry–Pérot etalon mirror dispersion and other optical properties of the system and the implications for the use of similar systems for precise Doppler measurements. Our results show that this system supports the wavelength calibration of HPF at the ≲10 cm s{sup −1} level over a night and the ≲30 cm s{sup −1} level over ∼10 days. Our results also highlight the need for long-term and spectrally resolved study of similar systems that will be deployed to support Doppler measurement precision approaching ∼10 cm s{sup −1}.

42 ENGINEERING↗

Effect of Near-field Distribution on Transmission Characteristics of Fiber-fed Fabry–Perot Etalons

Fiber-fed etalons are widely employed in advanced interferometric instruments such as gravitational-wave detectors, ultrastable lasers and calibration reference for high-precision spectrographs. We demonstrate that variation in near-field distribution of the feeding fiber would deteriorate the spectrum precision of the fiber-fed Fabry–Perot etalon, especially when precision at the order of 3 × 10{sup -10} or higher is required. The octagonal fiber reinforced with double scrambler could greatly improve the steadiness and uniformness of the near-field distribution. When building wavelength calibrators for sub-m s{sup -1} precision radial-velocity instruments, the double scrambler should be considered meticulously.

47 OTHER INSTRUMENTATION↗

Radiometrically accurate FTS for atmospheric emission observations

The calibration and operational performance of an FTIR-based airborne high-resolution interferometer sounder (HIS) for use in broadband measurements of atmospheric emission at 3.8-16.6 microns are described. The radiometric and wavelength calibration procedures in the laboratory involved the use of reference black bodies at 300 and 245 K and the known wavelength of the HIS HeNe laser (corrected for FOV effects), respectively. The atmospheric verification program included downlooking observations from the NASA U2/ER2 aircraft (where resolving power of 1800-3800 was demonstrated) and uplooking observations from the ground; good agreement with data from balloon-borne radiosondes is obtained, with absolute temperature uncertainties of less than 0.5 K and reproducibilities of 0.1-0.2 K over most of the measurement domain.

Revercomb, H. E.↗

Visible-Infrared Hyperspectral Image Projector

The VisIR HIP generates spatially-spectrally complex scenes. The generated scenes simulate real-world targets viewed by various remote sensing instruments. The VisIR HIP consists of two subsystems: a spectral engine and a spatial engine. The spectral engine generates spectrally complex uniform illumination that spans the wavelength range between 380 nm and 1,600 nm. The spatial engine generates two-dimensional gray-scale scenes. When combined, the two engines are capable of producing two-dimensional scenes with a unique spectrum at each pixel. The VisIR HIP can be used to calibrate any spectrally sensitive remote-sensing instrument. Tests were conducted on the Wide-field Imaging Interferometer Testbed at NASA s Goddard Space Flight Center. The device is a variation of the calibrated hyperspectral image projector developed by the National Institute of Standards and Technology in Gaithersburg, MD. It uses Gooch & Housego Visible and Infrared OL490 Agile Light Sources to generate arbitrary spectra. The two light sources are coupled to a digital light processing (DLP(TradeMark)) digital mirror device (DMD) that serves as the spatial engine. Scenes are displayed on the DMD synchronously with desired spectrum. Scene/spectrum combinations are displayed in rapid succession, over time intervals that are short compared to the integration time of the system under test.

Bolcar, Matthew↗

Measurements of antenna polar diagrams and efficiencies using a phase-switched interferometer

It is desirable to know antenna polar patterns and efficiencies accurately. In the past, calibration measurements have been made using balloons and aircraft and more recently satellites. These techniques are usually very expensive. It is shown that under certain circumstances it is possible to use a simpler and inexpensive technique by connecting together the antenna under test with another antenna to form a phase switched interferometer as first described by Ryle (1952). The technique does require a suitable radio source which gives measurable powers when using small antennas and since dipoles have broad patterns, radio sources with similar right ascensions but different declinations to the primary source can be a problem. These problems can partly be overcome by filtering the interference pattern.

Vincent, R. A.↗

Search for planets by spectroscopic methods

Spectroscopic means of detecting the motion of a star around a star-planet barycenter are considered. The precision of such an observation, which requires a radial velocity error of not more than 5 m/sec, is discussed in relation to the spectral resolutions of the detectors utilized. The University of Arizona radial velocity spectrometer is then presented, with particular attention given to the location of the absorption cell in a beam of light from an incandescent bulb, high-accuracy wavelength calibration involving the use of a Fabry-Perot interferometer in front of an echelle spectrograph, and future plans for the use of light reflected from a Fabry-Perot etalon to improve transmittance. On the basis of these techniques, it is expected that radial velocities with accuracies sufficient for the detection of extrasolar planets will be obtained.

Serkowski, K.↗

Calibration of Atmospherically Induced Delay Fluctuations Due to Water Vapor

We have completed a new generation of water vapor radiometers (WVR), the A- series, in order to support radio science experiments with the Cassini spacecraft. These new instruments sense three frequencies in the vicinity of the 22 GHz emission line of atmospheric water vapor within a 1 degree beamwidth from a clear aperture antenna that is co-pointed with the radio telescope down to 10 degree elevation. The radiometer electronics features almost an order of magnitude improvement in temperature stability compared with earlier WVR designs. For many radio science experiments, the error budget is likely to be dominated by path delay fluctuations due to variable atmospheric water vapor along the line-of-sight to the spacecraft. In order to demonstrate the performance of these new WVRs we are attempting to calibrate the delay fluctuations as seen by a radio interferometer operating over a 21 km baseline with a WVR near each antenna. The characteristics of these new WVRs will be described and the results of our preliminary analysis will be presented indicating an accuracy of 0.2 to 0.5 mm in tracking path delay fluctuations over time scales of 10 to 10,000 seconds.

Resch, George↗

Metrology of IXO Mirror Segments

For future x-ray astrophysics mission that demands optics with large throughput and excellent angular resolution, many telescope concepts build around assembling thin mirror segments in a Wolter I geometry, such as that originally proposed for the International X-ray Observatory. The arc-second resolution requirement posts unique challenges not just for fabrication, mounting but also for metrology of these mirror segments. In this paper, we shall discuss the metrology of these segments using normal incidence metrological method with interferometers and null lenses. We present results of the calibration of the metrology systems we are currently using, discuss their accuracy and address the precision in measuring near-cylindrical mirror segments and the stability of the measurements.

Chan, Kai-Wing↗

High Resolution Rapid Response Observations of Compact Radio Sources with the Ceduna Hobart Interferometer (CHI)

Context. Frequent, simultaneous observations across the electromagnetic spectrum are essential to the study of a range of astrophysical phenomena including Active Galactic Nuclei. A key tool of such studies is the ability to observe an object when it flares i.e. exhibits a rapid and significant increase in its flux density. Aims. We describe the specific observational procedures and the calibration techniques that have been developed and tested to create a single baseline radio interferometer. that can rapidly observe a flaring object. This is the only facility that is dedicated to rapid high resolution radio observations of an object south of -30 degrees declination. An immediate application is to provide rapid contemporaneous radio coverage of AGN flaring at y-ray frequencies detected by the Fermi Gamma-ray Space Telescope. Methods. A single baseline interferometer was formed with radio telescopes in Hobart, Tasmania and Ceduna, South Australia. A software correlator was set up at the University of Tasmania to correlate these data. Results. Measurements of the flux densities of flaring objects can be made using our observing strategy within half an hour of a triggering event. These observations can be calibrated with amplitude errors better than 20%. Lower limits to the brightness temperatures of the sources can also be calculated using CHI. Key words. instrumentation:interferometers - galaxies:active - galaxies:jets - galaxies:nuclei quasars:general gamma rays:galaxies- 1.

Blanchard, Jay M.↗

Transverse Pupil Shifts for Adaptive Optics Non-Common Path Calibration

A simple new way of obtaining absolute wavefront measurements with a laboratory Fizeau interferometer was recently devised. In that case, the observed wavefront map is the difference of two cavity surfaces, those of the mirror under test and of an unknown reference surface on the Fizeau s transmission flat. The absolute surface of each can be determined by applying standard wavefront reconstruction techniques to two grids of absolute surface height differences of the mirror under test, obtained from pairs of measurements made with slight transverse shifts in X and Y. Adaptive optics systems typically provide an actuated periscope between wavefront sensor (WFS) and commonmode optics, used for lateral registration of deformable mirror (DM) to WFS. This periscope permits independent adjustment of either pupil or focal spot incident on the WFS. It would be used to give the required lateral pupil motion between common and non-common segments, analogous to the lateral shifts of the two phase contributions in the lab Fizeau. The technique is based on a completely new approach to calibration of phase. It offers unusual flexibility with regard to the transverse spatial frequency scales probed, and will give results quite quickly, making use of no auxiliary equipment other than that built into the adaptive optics system. The new technique may be applied to provide novel calibration information about other optical systems in which the beam may be shifted transversely in a controlled way.

Bloemhof, Eric E.↗

A Demonstration of Precise Calibration of Tropospheric Delay Fluctuations with Water Vapor Radiometers

The ability of water vapor radiometers (WVRs) to calibrate changes in tropospheric delay was demonstrated during very long baseline radio interferometer (VLBI) observations at Goldstone, California. WVR measurements reduced the observed VLBI delay variations over a 13 hr period by a factor of approx. = 2.5. When applied to shorter time scales, a approx. = 50% reduction in 100-700 s delay variations was achieved during conditions of high tropospheric activity. Thermal WVR noise precluded calibration of short time scale delay fluctuations during quiet tropospheric conditions.

Teitelbaum, L. P.↗

The radial velocity search for extrasolar planets

Researchers are measuring small changes in the line-of-sight velocities of stars to detect the oscillating reflex acceleration induced by large planets. The intention is to observe enough stars for a long enough time to be able to make a statement of the probability of planets in a certain range of masses even if no planetary perturbations are detected. To make these measurements of Doppler shift with the required sensitivity, a new instrument was specifically designed, built and tested for this campaign of ground-based planet detection. The instrument is an optical spectrometer for which wavelengths are first calibrated by transmission through a tunable Fabry-Perot etalon interferometer. The intrinsic stability of the etalon and an image-scrambling fiber optic light feed provide great sensitivity to line-of-sight accelerations and immunity to systematic errors.

Mcmillen, Robert S.↗

2006 Interferometry Imaging Beauty Contest

We present a formal comparison of the performance of algorithms used for synthesis imaging with optical/infrared long-baseline interferometers. Five different algorithms are evaluated based on their performance with simulated test data. Each set of test data is formatted in the OI-FITS format. The data are calibrated power spectra and bispectra measured with an array intended to be typical of existing imaging interferometers. The strengths and limitations of each algorithm are discussed.

aperture synthesis↗

Timing Calibration and Windowing Technique Comparison for Lightning Mapping Arrays

Abstract Since their introduction 22 years ago, lightning mapping arrays (LMA) have played a central role in the investigation of lightning physics. Even in recent years with the proliferation of digital interferometers and the introduction of the LOw Frequency ARray (LOFAR) radio telescope, LMAs still play an important role in lightning science. LMA networks use a simple windowing technique that records the highest pulse in either 80 μs or 10 μs fixed windows in order to apply a time‐of‐arrival location technique. In this work, we develop an LMA‐emulator that uses lightning data recorded by LOFAR to simulate an LMA, and we use it to test three new styles of pulse windowing. We show that they produce very similar results as the more traditional LMA windowing, implying that LMA lightning mapping results are relatively independent of windowing technique. In addition, each LMA station has its GPS‐conditioned clock. While the timing accuracy of GPS receivers has improved significantly over the years, they still significantly limit the timing measurements of the LMA. Recently, new time‐of‐arrival techniques have been introduced that can be used to self‐calibrate systematic offsets between different receiving stations. Applying this calibration technique to a set of data with 32 ns uncertainty, observed by the Colorado LMA, improves the timing uncertainty to 19 ns. This technique is not limited to LMAs and could be used to help calibrate future multi‐station lightning interferometers.

Hare, Brian M.↗

Calibration of the Urbana lidar system

A method for calibrating data obtained by the Urban sodium lidar system is presented. First, an expression relating the number of photocounts originating from a specific altitude range to the soodium concentration is developed. This relation is then simplified by normalizing the sodium photocounts with photocounts originating from the Rayleigh region of the atmosphere. To evaluate the calibration expression, the laser linewidth must be known. Therefore, a method for measuring the laser linewidth using a Fabry-Perot interferometer is given. The laser linewidth was found to be 6 + or - 2.5 pm. Problems due to photomultiplier tube overloading are discussed. Finally, calibrated data is presented. The sodium column abundance exhibits something close to a sinusoidal variation throughout the year with the winter months showing an enhancement of a factor of 5 to 7 over the summer months.

Cerny, T.↗