Search NASA⌕ Search

SEARCH · Search NASA

Results for “calibration interferometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Transverse Pupil Shifts for Adaptive Optics Non-Common Path Calibration

A simple new way of obtaining absolute wavefront measurements with a laboratory Fizeau interferometer was recently devised. In that case, the observed wavefront map is the difference of two cavity surfaces, those of the mirror under test and of an unknown reference surface on the Fizeau s transmission flat. The absolute surface of each can be determined by applying standard wavefront reconstruction techniques to two grids of absolute surface height differences of the mirror under test, obtained from pairs of measurements made with slight transverse shifts in X and Y. Adaptive optics systems typically provide an actuated periscope between wavefront sensor (WFS) and commonmode optics, used for lateral registration of deformable mirror (DM) to WFS. This periscope permits independent adjustment of either pupil or focal spot incident on the WFS. It would be used to give the required lateral pupil motion between common and non-common segments, analogous to the lateral shifts of the two phase contributions in the lab Fizeau. The technique is based on a completely new approach to calibration of phase. It offers unusual flexibility with regard to the transverse spatial frequency scales probed, and will give results quite quickly, making use of no auxiliary equipment other than that built into the adaptive optics system. The new technique may be applied to provide novel calibration information about other optical systems in which the beam may be shifted transversely in a controlled way.

Bloemhof, Eric E.↗

A Demonstration of Precise Calibration of Tropospheric Delay Fluctuations with Water Vapor Radiometers

The ability of water vapor radiometers (WVRs) to calibrate changes in tropospheric delay was demonstrated during very long baseline radio interferometer (VLBI) observations at Goldstone, California. WVR measurements reduced the observed VLBI delay variations over a 13 hr period by a factor of approx. = 2.5. When applied to shorter time scales, a approx. = 50% reduction in 100-700 s delay variations was achieved during conditions of high tropospheric activity. Thermal WVR noise precluded calibration of short time scale delay fluctuations during quiet tropospheric conditions.

Teitelbaum, L. P.↗

The radial velocity search for extrasolar planets

Researchers are measuring small changes in the line-of-sight velocities of stars to detect the oscillating reflex acceleration induced by large planets. The intention is to observe enough stars for a long enough time to be able to make a statement of the probability of planets in a certain range of masses even if no planetary perturbations are detected. To make these measurements of Doppler shift with the required sensitivity, a new instrument was specifically designed, built and tested for this campaign of ground-based planet detection. The instrument is an optical spectrometer for which wavelengths are first calibrated by transmission through a tunable Fabry-Perot etalon interferometer. The intrinsic stability of the etalon and an image-scrambling fiber optic light feed provide great sensitivity to line-of-sight accelerations and immunity to systematic errors.

Mcmillen, Robert S.↗

2006 Interferometry Imaging Beauty Contest

We present a formal comparison of the performance of algorithms used for synthesis imaging with optical/infrared long-baseline interferometers. Five different algorithms are evaluated based on their performance with simulated test data. Each set of test data is formatted in the OI-FITS format. The data are calibrated power spectra and bispectra measured with an array intended to be typical of existing imaging interferometers. The strengths and limitations of each algorithm are discussed.

aperture synthesis↗

Calibration of the Urbana lidar system

A method for calibrating data obtained by the Urban sodium lidar system is presented. First, an expression relating the number of photocounts originating from a specific altitude range to the soodium concentration is developed. This relation is then simplified by normalizing the sodium photocounts with photocounts originating from the Rayleigh region of the atmosphere. To evaluate the calibration expression, the laser linewidth must be known. Therefore, a method for measuring the laser linewidth using a Fabry-Perot interferometer is given. The laser linewidth was found to be 6 + or - 2.5 pm. Problems due to photomultiplier tube overloading are discussed. Finally, calibrated data is presented. The sodium column abundance exhibits something close to a sinusoidal variation throughout the year with the winter months showing an enhancement of a factor of 5 to 7 over the summer months.

Cerny, T.↗

Calibrating Droplet Generator for Pressurized Testing Vessel

Device helps to aline laser for droplet-sizing interferometer. Monodispersing Droplet Generator creates uniformly sized droplets. Laser source and receiver of interferometer alined and focused on droplets. MDG mounted in high-pressure flange on tank. Line extensions pass through flange to outside. Flange allows MDG to operate at high injector back pressures used for tests.

Defever, G. J.↗

Shear/Defocus Sensitivity of the Mid Infrared Channel (MIR) of the Composite Infrared Spectrometer (CIRS) for the Cassini Mission to Saturn

The Composite Infrared Spectrometer (CIRS) of the Cassini mission to Saturn has two interferometers covering the far infrared and mid infrared wavelength region. The mid infrared wavelength interferometer has a focal plane consisting of a germanium focus lens and HgCdTe array. System level calibration of the CIRS Flight Unit indicated a discrepancy between the expected and actual signal levels. Testing on the CIRS breadboard and Engineering Unit indicated that defocus of the germanium lens could significantly reduce the modulation efficiency of the interferometer in the presence of a moderate degree of wavefront shear. Defocus of the lens in the focal plane was of concern because of the temperature dependence of the index of refraction of germanium and our nominal operation temperature of 170 K. The shear/defocus interaction was extensively investigated and correlated to a newly developed analytical model, It was eventually determined that the CIRS instrument was in focus, had no appreciable wavefront shear and was operating near theoretical limits. The shear/defocus effect is however, of considerable interest, since it has not been described in previous literature on interferometers.

Martino, Anthony J.↗

High Resolution Wavenumber Standards for the Infrared. (IUPAC Recommendations 1995)

The calibration of high resolution infrared spectra is generally more precise than accurate even when they are recorded with Fourier interferometers. In order to improve the consistency of the spectral measurements, an IUPAC project has been undertaken. Its aim was to recommend a selection of spectral lines as wavenumber standards for absolute calibration in the infrared. This paper will report the final recommendations in the spectral range extending from about 4 to about 7000 cm(be).

High Resolution Wavenumber Standards↗

A Short-Range Distance Sensor with Exceptional Linearity

A sensor has been demonstrated that can measure distance over a total range of about 300 microns to an accuracy of about 0.1 nm (resolution of about 0.01 nm). This represents an exceptionally large dynamic range of operation - over 1,000,000. The sensor is optical in nature, and requires the attachment of a mirror to the object whose distance is being measured. This work resulted from actively developing a white light interferometric system to be used to measure the depths of defects in the Space Shuttle Orbiter windows. The concept was then applied to measuring distance. The concept later expanded to include spectrometer calibration. In summary, broadband (i.e., white) light is launched into a Michelson interferometer, one mirror of which is fixed and one of which is attached to the object whose distance is to be measured. The light emerging from the interferometer has traveled one of two distances: either the distance to the fixed mirror and back, or the distance to the moving mirror and back. These two light beams mix and produce an interference pattern where some wavelengths interfere constructively and some destructively. Sending this light into a spectrometer allows this interference pattern to be analyzed, yielding the net distance difference between the two paths. The unique feature of this distance sensor is its ability to measure accurately distance over a dynamic range of more than one million, the ratio of its range (about 300 microns) to its accuracy (about 0.1 nanometer). Such a large linear operating range is rare and arises here because both amplitude and phase-matching algorithms contribute to the performance. The sensor is limited by the need to attach a mirror of some kind to the object being tracked, and by the fairly small total range, but the exceptional dynamic range should make it of interest.

Simmons, Steven↗

High Resolution Wavenumber Standards for the Infrared. (IUPAC Recommendations 1995)

The calibration of high resolution infrared spectra is generally more precise than accurate. This is the case even when they are recorded with Fourier transform interferometers. This presentation aims at improving the accuracy of wavenumber measurements in the infrared by recommending a selection of spectral lines as wavenumber standards for absolute calibration.

Interferometers Infrared Spectra Wavenumbers Fouri↗

An Interferometry Imaging Beauty Contest

We present a formal comparison of the performance of algorithms used for synthesis imaging with optical/infrared long-baseline interferometers. Six different algorithms are evaluated based on their performance with simulated test data. Each set of test data is formated in the interferometry Data Exchange Standard and is designed to simulate a specific problem relevant to long-baseline imaging. The data are calibrated power spectra and bispectra measured with a ctitious array, intended to be typical of existing imaging interferometers. The strengths and limitations of each algorithm are discussed.

aperture synthesis↗

Implementation of RF Circuitry for Real-Time Digital Beam-Forming SAR Calibration Schemes

The SweepSAR architecture for space-borne remote sensing applications is an enabling technology for reducing the temporal baseline of repeat-pass interferometers while maintaining near-global coverage. As part of this architecture, real-time digital beam-forming would be performed on the radar return signals across multiple channels. Preserving the accuracy of the combined return data requires real-time calibration of the transmit and receive RF paths on each channel. This paper covers several of the design considerations necessary to produce a practical implementation of this concept.

calibration↗

Multi-axis Heterodyne Interferometry at MHz Frequencies: a Short-Arm Measurement Demonstration for LISA with Off-The-Shelf Hardware

We report the design, construction, and operation of a multi-axis heterodyne interferometry (MAHI) system operating at MHz heterodyne frequencies, which provides a testbed for technologies to be used in the Laser Interferometer Space Antenna (LISA) space-based gravitational wave mission. The system was calibrated for measurement of the piston, pitch, and yaw of a three-axis piezo-actuated mirror, giving measured calibration values that closely match those predicted by a simulation based on Gaussian beam tracing. The piston sensitivity of the MAHI system in the LISA band was measured to be below 10pmHz 1/2 10pmHz1/2 for frequencies above 4 mHz and below 1pmHz 1/2 1pmHz1/2 for frequencies above 35 mHz. The sensitivity is limited above 2 Hz by the mechanical vibrations of the apparatus and below 1 mHz by dimensional changes caused by temperature fluctuations. Evidence points towards scattered light as the limiting noise source at intermediate frequencies. The angular sensitivity of the MAHI system was measured to be close to or below 10nradHz 1/2 10nradHz1/2 for frequencies above 4 mHz and below 1nradHz 1/2 1nradHz1/2 for frequencies above 100 mHz. Noise budgets for both length and angle were determined, indicating the areas in which improvements must be made in order to reach increased sensitivity. The current operating sensitivity already provides a useful testbed for LISA technologies and a potential blueprint for future ground segment equipment.

Fulda, P.↗

SCDU (Spectral Calibration Development Unit) Testbed Narrow Angle Astrometric Performance

The most stringent astrometric performance requirements on NASA's SIM(Space Interferometer Mission)-Lite mission will come from the so-called Narrow-Angle (NA) observing scenario, aimed at finding Earth-like exoplanets, where the interferometer chops between the target star and several nearby reference stars multiple times over the course of a single visit. Previously, about 20 pm NA error with various shifts was reported. Since then, investigation has been under way to understand the mechanisms that give rise to these shifts. In this paper we report our findings, the adopted mitigation strategies, and the resulting testbed performance.

Interferometer↗