Search NASA⌕ Search

SEARCH · Search NASA

Results for “calorimeter simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Estimating Cosmic Ray Spectral Parameters from Simulated Detector Responses

A simple power law model consisting of a single spectral index al is believed to be an adequate description of the galactic cosmic ray (GCR) proton flux at energies below 100 TeV, with a transition at kink energy Ek to a steeper spectral index a2>al above Ek. The maximum likelihood procedure is developed for estimating these three spectral parameters of the broken power law energy spectrum from simulated detector responses. These estimates and their surrounding statistical uncertainty are being used to derive the requirements in energy resolution, calorimeter size, and energy response of a proposed sampling calorimeter for the Advanced Cosmic-ray Composition Experiment for the Space Station (ACCESS). This study thereby permits instrument developers to make important trade studies in design parameters as a function of the science objectives, which is particularly important for space-based detectors where physical parameters, such as dimension and weight, impose rigorous practical limits to the design envelope.

Howell, Leonard↗

Estimating Cosmic Ray Spectral Parameters From Simulated Detector Responses With Detector Design Implications

A simple power law model consisting of a single spectral index alpha (sub 1), is believed to be an adequate description of the galactic cosmic ray (GCR) proton flux at energies below 10(exp 13) eV, with a transition at knee energy E(sub k) to a steeper spectral index alpha(sub 2) greater than alpha(sub 1) above E(sub k). The maximum likelihood procedure is developed for estimating these three spectral parameters of the broken power law energy spectrum from simulated detector responses. These estimates and their surrounding statistical uncertainty are being used to derive the requirements in energy resolution, calorimeter size, and energy response of a proposed sampling calorimeter for the Advanced Cosmic ray Composition Experiment for the Space Station (ACCESS). This study thereby permits instrument developers to make important trade studies in design parameters as a function of the science objectives, which is particularly important for space-based detectors where physical parameters, such as dimension and weight, impose rigorous practical limits to the design envelope.

Howell, L. W.↗

Estimating Cosmic-Ray Spectral Parameters from Simulated Detector Responses with Detector Design Implications

A simple power law model consisting of a single spectral index (alpha-1) is believed to be an adequate description of the galactic cosmic-ray (GCR) proton flux at energies below 10(exp 13) eV, with a transition at knee energy (E(sub k)) to a steeper spectral index alpha-2 > alpha-1 above E(sub k). The maximum likelihood procedure is developed for estimating these three spectral parameters of the broken power law energy spectrum from simulated detector responses. These estimates and their surrounding statistical uncertainty are being used to derive the requirements in energy resolution, calorimeter size, and energy response of a proposed sampling calorimeter for the Advanced Cosmic-ray Composition Experiment for the Space Station (ACCESS). This study thereby permits instrument developers to make important trade studies in design parameters as a function of the science objectives, which is particularly important for space-based detectors where physical parameters, such as dimension and weight, impose rigorous practical limits to the design envelope.

Howell, L. W.↗

An instrument to measure the spectrum of cosmic ray iron and other nuclei to above 100 GeV/nucleon

A balloon-borne instrument system for the study of cosmic ray composition in the energy region beyond 100 GeV/nucleon is described. The large area detector incorporates an ionization spectrometer or calorimeter to determine the energy of the incident particles which is calibrated in flight by a gas Cerenkov counter filled with freon 12 at 20 psi. Calibration of calorimeter response indicates that the effects of ionization energy loss and nucleon fragmentation are correctly accounted for in a Monte Carlo simulation. A charge measuring module consisting of five scintillators and a lucite Cerenkov counter is used to determine the charge and position of the incoming particles. A spatial resolution of 5 to 10 cm has been obtained by using the ratios of pulse heights in different photomultiplier tubes aimed at the same scintillators within the module. The detector represents the heaviest cosmic ray experiment that can be flown over 30 km using the dynamic launching technique commonly employed.

Arens, J. F.↗

Design, development, and test of Shuttle/Centaur G-prime cryogenic tankage thermal protection systems

The thermal protection systems (TPS) for the Shuttle/Centaur were designed to provide fail-safe thermal protection during prelaunch, launch ascent, and on-orbit operations as well as during potential abort, where the Shuttle and Centaur would return to earth. The TPS selected used a helium-purged polyimide foam beneath three radiation shields for the liquid-hydrogen (LH2) tank and radiation shields only for the liquid-oxygen (LO2) tank. A double-walled vacuum bulkhead separated the two tanks. The LH2 tank had one 1.9 cm-thick layer of foam on the forward bulkhead and two layers on the larger-area sidewall. Full scale tests of the flight vehicle in a simulated Shuttle cargo bay gave total prelaunch heating rates of 29.5 and 12.9 kW for the LH2 and LO2 tanks, respectively. Calorimeter tests on a representative sample of the LH2 tank sidewall TPS indicated that the measured unit heating one would rapidly decrease from the prelaunch rate of about 300 W/sq m to a desired rate less than 4 W/sq m once on-orbit.

Macneil, Peter N.↗

Laboratory Measurements of the Dielectronic Recombination Satellite Transitions of He-Like FE XXV and H-Like FE XXVI

We present laboratory spectra of dielectronic recombination (DR) satellite transitions attached to the He-like and H-like iron resonance lines obtained with the NASA Goddard Space Flight Center X-ray calorimeter and produced by a thermal plasma simu1ation technique on the EBIT-I electron beam ion trap at the Lawrence Livermore National Laboratory. We demonstrate that the calorimeter has sufficient spectral resolution in the 6-9 keV range to provide reliable measurements not only of standard DR satellite to resonance line intensities but also of DR satellite to DR satellite ratios that can be used to diagnose nonthermal electron distributions. Electron temperatures derived from the measured line intensities are consistent with the temperature of the simulated plasma. Temperature measurements based on DR satellite transitions have significant advantages over those based on collisional ionization equilibrium or continuum shape. Thus, successful demonstration of this method with the X-ray calorimeter is an important step fur its application in X-ray astronomy.

Gu, M. F.↗

Computational Simulations of the 10-MW TP3 Arc-Jet Facility Flow

This paper reports computational simulations and analysis in support of calibration tests in a high enthalpy arc-jet facility at NASA Ames Research Center. These tests were conducted using stagnation calorimeters and two different blunted wedge models with calibration plates at a wide range of conditions in the NASA Ames 10-megawatt TP3 (Test Position 3) facility. Data were obtained using four different conical nozzles with the same test configuration in which the models were placed in a free jet downstream of the nozzle. Experimental surveys of arc-jet test flow with pitot and null-point heat flux probes were also performed at several arc-heater conditions, providing assessment of the flow uniformity and valuable data for the flow characterization. The present analysis comprises computational fluid dynamics simulations of the nonequilibrium flowfield in the facility nozzle and test box, including the models tested, and comparisons with the experimental measurements. These computational simulations provide estimates of the arc-jet test environment parameters that are not measured but are needed to evaluate the performance of thermal protection system materials, along with further valuable insights into the arc-jet testing environment. Simulation results are used to estimate centerline total enthalpy, surface shear, boundary layer thickness, and boundary layer edge Mach number and to verify that specific test requirements from the Orion program are met.

CFD↗

Design and simulation of a SiPM-on-tile ZDC for the future EIC, and its performance with graph neural networks

We present a design for a high-granularity zero-degree calorimeter (ZDC) for the upcoming Electron-Ion Collider (EIC). The design uses SiPM-on-tile technology and features a novel staggered-layer arrangement that improves spatial resolution. To fully leverage the design’s high granularity and non-trivial geometry, we employ graph neural networks (GNNs) for energy and angle regression as well as signal classification. The GNN-boosted performance metrics meet, and in some cases, significantly surpass the requirements set in the report on science requirements and detector requirements for the EIC (Yellow Report), laying the groundwork for enhanced measurements that will facilitate a wide physics program. Our studies show that GNNs can significantly enhance the performance of high-granularity CALICE-style calorimeters by automating and optimizing the software compensation algorithms required for these systems. This improvement holds true even in the case of complicated geometries that pose challenges for image-based AI/ML methods.

Calorimeter↗

Calibrated particle identification for Belle II

We present several efforts aimed at improving charged particle identification at the Belle II experiment. We define an ablation test to quantify and evaluate the impact of each sub-detector on the global particle identification performance. We demonstrate that the performance of the identification scheme can be improved via a simple calibration of the sub-detector likelihoods through a set of per hypothesis, per sub-detector weights. Finally, we present preliminary results on an improved definition of the likelihoods contributed by the electromagnetic calorimeter. A set of multiclass boosted decision trees is trained to exploit the shape of energy depositions of different particle species. In simulated $B\bar{B}$ events, the pion-to-electron and muon fake rates are reduced by 55% and 31% respectively at low-medium momentum.

Hohmann, Marcel [Univ. of Melbourne, Parkville, VI↗

An Earth-Based Equivalent Low Stretch Apparatus to Assess Material Flammability for Microgravity and Extraterrestrial Fire-Safety Applications

The objective of this project is to modify the standard oxygen consumption (cone) calorimeter (described in ASTM E 1354 and NASA STD 6001 Test 2) to provide a reproducible bench-scale test environment that simulates the buoyant or ventilation flow that would be generated by or around a burning surface in a spacecraft or extraterrestrial gravity level. This apparatus will allow us to conduct normal gravity experiments that accurately and quantitatively evaluate a material's flammability characteristics in the real-use environment of spacecraft or extra-terrestrial gravitational acceleration. The Equivalent Low Stretch Apparatus (ELSA) uses an inverted cone geometry with the sample burning in a ceiling fire configuration that provides a reproducible bench-scale test environment that simulates the buoyant or ventilation flow that would be generated by a flame in a spacecraft or extraterrestrial gravity level. Prototype unit testing results are presented in this paper. Ignition delay times and regression rates for PMMA are presented over a range of radiant heat flux levels and equivalent stretch rates which demonstrate the ability of ELSA to simulate key features of microgravity and extraterrestrial fire behavior.

Olson, S. L.↗

AI-assisted object condensation clustering for calorimeter shower reconstruction at CLAS12

Several nuclear physics studies using the CLAS12 detector rely on the accurate reconstruction of neutrons and photons from its forward angle calorimeter system. These studies often place restrictive cuts when measuring neutral particles due to an overabundance of false clusters created by the existing calorimeter reconstruction software. In this work, we present a new AI approach to clustering CLAS12 calorimeter hits based on the object condensation framework. The model learns a latent representation of the full detector topology using GravNet layers, serving as the positional encoding for an event’s calorimeter hits which are processed by a Transformer encoder. This unique structure allows the model to contextualize local and long range information, improving its performance. Evaluated on one million simulated $e^-$ $+$ $p$ collision events, our method significantly improves cluster trustworthiness: the fraction of reliable neutron clusters, increasing from 8.88% to 30.73%, and photon clusters, increasing from 51.07% to 64.73%. In conclusion, our study also marks the first application of AI clustering techniques for hodoscopic detectors, showing potential for usage in many other experiments.

Calorimeters↗

A New Test Method for Material Flammability Assessment in Microgravity and Extraterrestrial Environments

The standard oxygen consumption (cone) calorimeter (described in ASTM E 1354 and NASA STD 6001 Test 2) is modified to provide a bench-scale test environment that simulates the low velocity buoyant or ventilation flow generated by or around a burning surface in a spacecraft or extraterrestrial gravity level. The Equivalent Low Stretch Apparatus (ELSA) uses an inverted cone geometry with the sample burning in a ceiling fire (stagnation flow) configuration. For a fixed radiant flux, ignition delay times for characterization material PMMA are shown to decrease by a factor of three at low stretch, demonstrating that ignition delay times determined from normal cone tests significantly underestimate the risk in microgravity. The critical heat flux for ignition is found to be lowered at low stretch as the convective cooling is reduced. At the limit of no stretch, any heat flux that exceeds the surface radiative loss at the surface ignition temperature is sufficient for ignition. Regression rates for PMMA increase with heat flux and stretch rate, but regression rates are much more sensitive to heat flux at the low stretch rates, where a modest increase in heat flux of 25 kW/m2 increases the burning rates by an order of magnitude. The global equivalence ratio of these flames is very fuel rich, and the quantity of CO produced in this configuration is significantly higher than standard cone tests. These results [2] demonstrate the ELSA apparatus allows us to conduct normal gravity experiments that accurately and quantifiably evaluate a material s flammability characteristics in the real-use environment of spacecraft or extra-terrestrial gravitational acceleration. These results also demonstrate that current NASA STD 6001 Test 2 (standard cone) is not conservative since it evaluates materials flammability with a much higher inherent buoyant convective flow.

Olson, S. L.↗

Advanced Thermal Simulator Testing: Thermal Analysis and Test Results

Work at the NASA Marshall Space Flight Center seeks to develop high fidelity, electrically heated thermal simulators that represent fuel elements in a nuclear reactor design to support non-nuclear testing applicable to the development of a space nuclear power or propulsion system. Comparison between the fuel pins and thermal simulators is made at the outer fuel clad surface, which corresponds to the outer sheath surface in the thermal simulator. The thermal simulators that are currently being tested correspond to a SNAP derivative reactor design that could be applied for Lunar surface power. These simulators are designed to meet the geometric and power requirements of a proposed surface power reactor design, accommodate testing of various axial power profiles, and incorporate imbedded instrumentation. This paper reports the results of thermal simulator analysis and testing in a bare element configuration, which does not incorporate active heat removal, and testing in a water-cooled calorimeter designed to mimic the heat removal that would be experienced in a reactor core.

Bragg-Sitton, Shannon M.↗

Pulse Detonation Engine Test Bed Developed

A detonation is a supersonic combustion wave. A Pulse Detonation Engine (PDE) repetitively creates a series of detonation waves to take advantage of rapid burning and high peak pressures to efficiently produce thrust. NASA Glenn Research Center's Combustion Branch has developed a PDE test bed that can reproduce the operating conditions that might be encountered in an actual engine. It allows the rapid and cost-efficient evaluation of the technical issues and technologies associated with these engines. The test bed is modular in design. It consists of various length sections of both 2- and 2.6- in. internal-diameter combustor tubes. These tubes can be bolted together to create a variety of combustor configurations. A series of bosses allow instrumentation to be inserted on the tubes. Dynamic pressure sensors and heat flux gauges have been used to characterize the performance of the test bed. The PDE test bed is designed to utilize an existing calorimeter (for heat load measurement) and windowed (for optical access) combustor sections. It uses hydrogen as the fuel, and oxygen and nitrogen are mixed to simulate air. An electronic controller is used to open the hydrogen and air valves (or a continuous flow of air is used) and to fire the spark at the appropriate times. Scheduled tests on the test bed include an evaluation of the pumping ability of the train of detonation waves for use in an ejector and an evaluation of the pollutants formed in a PDE combustor. Glenn's Combustion Branch uses the National Combustor Code (NCC) to perform numerical analyses of PDE's as well as to evaluate alternative detonative combustion devices. Pulse Detonation Engine testbed.

Breisacher, Kevin J.↗

On Characterization of Laminar to Turbulent Transitional Flow in the Truncated IHF Semi-Elliptical Nozzle

This paper reports computational analysis and experimental data to characterize the laminar to turbulent flow transition in a high-enthalpy panel test facility at NASA Ames Research Center. The recently developed facility configuration uses a truncated version of an existing semi-elliptical nozzle in the 60-MW Interaction Heating Facility, and it provides testing capability for panel test articles as large as 43.2 cm x 43.2 cm (17 in x 17 in). A water-cooled calibration plate, which is attached to the semi-elliptical nozzle bottom surface and instrumented with twenty Gardon-gage heat flux calorimeters and twelve pressure gages, is used to characterize the convective heating environment over the panel test articles. The present analysis comprises computational fluid dynamics simulations of the nonequilibrium flowfield in the facility nozzle and test box, and the flowfields over panel test articles, and comparisons with the measured test data. Both laminar and turbulent simulations are performed. Constant current studies are performed: the measured data are grouped at the same arc current levels with varying mass flow rates, and they are compared with corresponding computations. For all currents studied, these studies indicate that the semi-elliptical nozzle flow is transitional at relatively higher mass flow rates within the facility operating envelope.

Arc-jets↗

On Characterization of Laminar to Turbulent Transitional Flow in the Truncated IHF Semi-Elliptical Nozzle

This paper reports computational analysis and experimental data to characterize the laminar to turbulent flow transition in a high-enthalpy panel test facility at NASA Ames Research Center. The recently developed facility configuration uses a truncated version of an existing semi-elliptical nozzle in the 60-MW Interaction Heating Facility, and it provides testing capability for panel test articles as large as 43.2 cm x 43.2 cm (17 in x 17 in). A water-cooled calibration plate, which is attached to the semi-elliptical nozzle bottom surface and instrumented with twenty Gardon-gage heat flux calorimeters and twelve pressure gages, is used to characterize the convective heating environment over the panel test articles. The present analysis comprises computational fluid dynamics simulations of the nonequilibrium flowfield in the facility nozzle and test box, and the flowfields over panel test articles, and comparisons with the measured test data. Both laminar and turbulent simulations are performed. Constant current studies are conducted: the measured data are grouped at the same arc current levels with varying mass flow rates, and they are compared with corresponding computations. For all currents considered, these studies indicate that the semi-elliptical nozzle flow is transitional at relatively higher mass flow rates within the facility operating envelope. An approximate facility map for the transitional flow characterization is developed, showing laminar and transitional to turbulent flow regions.

Arc-jets↗

CFD Simulations of the AEDC H3 Arc-Jet Flow: Mach 3.3 Nozzle, Flow Surveys, Wedge Models

This paper reports computational simulations and analysis of tests in a high enthalpy arc-jet facility at Arnold Engineering Development Center. These tests were conducted using wedge models placed in a free jet downstream of a 4.5-inch diameter contoured Mach 3.3 nozzle in the H3 facility. For calibration of test conditions, one wedge calibration plate instrumented with an array of pressure and coaxial thermocouple heat flux gages, one stagnation pressure probe and two null-point heat flux calorimeters were used. The pitot pressure and null-point probe measurements give experimental surveys of the test flow, providing assessment of the flow uniformity and valuable data for flow characterization. The present analysis comprises computational fluid dynamics simulations of the nonequilibrium flowfield in the facility nozzle, into the test box and over the wedge models, and comparisons with the experimental measurements. Several issues related to testing are considered: test flow characterization, prediction of surface quantities for three wedge models, effects of model shape change and test article recession, and prediction of surface quantities for the test articles with two circular cavities. These simulations take into account non-uniform total enthalpy profiles at the nozzle inlet as well as the expansion waves emanating from the nozzle exit and their effects on the wedge model flowfields.

Arc-jet testing↗

High Energy Electron and Gamma - Ray Detection with ATIC

The Advanced Thin Ionization Calorimeter (ATIC) balloon borne ionization calorimeter is well suited to record and identify high energy cosmic ray electrons, and at very high energies gamma-ray photons as well. We have simulated the performance of the instrument, and compare the simulations with actual high energy electron exposures at the CERN accelerator. Simulations and measurements do not compare exactly, in detail, but overall the simulations have predicted actual measured behavior quite well. ATIC has had its first 16 day balloon flight at the turn of the year over Antarctica, and first results obtained using the analysis methods derived from simulations and calibrations will be reported.

Chang, J.↗