Search NASA⌕ Search

SEARCH · Search NASA

Results for “camera mobility”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Miniature, mobile X-ray computed radiography system

A miniature, portable x-ray system may be configured to scan images stored on a phosphor. A flash circuit may be configured to project red light onto a phosphor and receive blue light from the phosphor. A digital monochrome camera may be configured to receive the blue light to capture an article near the phosphor.

36 MATERIALS SCIENCE↗

An automatic and accurate x-ray tube focal spot/grid alignment system for mobile radiography: System description and alignment accuracy

Purpose: A mobile radiography automatic grid alignment system (AGAS) has been developed by modifying a commercially available mobile unit. The objectives of this article are to describe the modifications and operation and to report on the accuracy with which the focal spot is aligned to the grid and the time required to achieve the alignment. Methods: The modifications include an optical target arm attached to the grid tunnel, a video camera attached to the collimator, a motion control system with six degrees of freedom to position the collimator and x-ray tube, and a computer to control the system. The video camera and computer determine the grid position, and then the motion control system drives the x-ray focal spot to the center of the grid focal axis. The accuracy of the alignment of the focal spot with the grid and the time required to achieve alignment were measured both in laboratory tests and in clinical use. Results: For a typical exam, the modified unit automatically aligns the focal spot with the grid in less than 10 s, with an accuracy of better than 4 mm. The results of the speed and accuracy tests in clinical use were similar to the results in laboratory tests. Comparison patient chest images are presented--one obtained with a standard mobile radiographic unit without a grid and the other obtained with the modified unit and a 15:1 grid. The 15:1 grid images demonstrate a marked improvement in image quality compared to the nongrid images with no increase in patient dose. Conclusions: The mobile radiography AGAS produces images of significantly improved quality compared to nongrid images with alignment times of less than 10 s and no increase in patient dose.

61 RADIATION PROTECTION AND DOSIMETRY↗

Development of a drone equipped with optimized sensors for nuclear and radiological risk characterization

The MOBISIC project, funded by the Systematic Paris-Region cluster, is being developed in the context of local crisis (attack bombing in urban environment, in confined space such as an underground train tunnel etc.) or specific event securing (soccer world cup, political meeting etc.). It consists in conceiving, developing and experimenting a mobile, modular ('plug and play') and multi-sensors securing system. In this project, CEA LIST has suggested different solutions for nuclear risks detection and identification. It results in embedding a CZT sensor and a gamma camera in an indoor drone. This article first presents the different modifications carried out on the UAV and different sensors, and focuses then on the experimental performances. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Gamma imaging and mapping advancements

The Savannah River National Lab (SRNL) in partnership with Los Alamos National Lab (LANL) developed an in-situ GrayQb™ radiation mapping device eliminating the need to remove the radiation sensitive phosphor storage plate (PSP) from the device for scanning between exposures. By incorporating a customized version of the LANL patented MiniMax camera-based PSP reader system into the GrayQb™ housing, the exposed PSP can now be read in-situ and digitally transmitted to a remote computer for viewing. The ability to generate radiation contour maps showing source locations and relative radiological levels present in an area has high utility for targeting clean-up efforts, maintaining worker ALARA, determining leak locations and radiological situational awareness. In-situ GrayQb™ reduces the number of required interactions with the device providing deployment cost savings, increasing personnel safety and removing human handling errors during the manual scan process. Additionally, by negating the need for an external scanner, the device becomes more mobile. Other upgrades to the device included identification of a more sensitive imaging medium and incorporation of a dual pinhole rendering the device physically capable of obtaining 3D images. Laboratory tests with Am-241 sources using a mockup of the in-situ GrayQ™, successfully demonstrated the ability to digitally capture radiation source information using the dual pinhole and camera-based PSP reader.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

3-D Volumetric Gamma-ray Imaging and Source Localization with a Mobile Robot - 18124

Radiation detection has largely been a manual inspection process with point sensors such as Geiger-Muller counters and scintillation spectrometers to date. While their observations of source proximity prove useful, they lack the directional information necessary for efficient source localization and characterization in cluttered environments with multiple radiation sources. The recent commercialization of Compton gamma cameras provides directional information to the broader radiation detection community for the first time. This paper presents the integration of a Compton gamma camera with a self-localizing ground robot for accurate 3D radiation mapping. Using the position and orientation of the robot, radiation images from the gamma camera are accumulated over a traversed path in a shared frame of reference to construct a consistent voxel grid-based radiation map. The peaks of the map at pre-specified energy windows are selected as the source location estimates, which are compared to the ground truth source locations. The proposed approach localizes multiple sources to within an average of 0.2 m in two 5 x 4 m{sup 2} and 14 x 6 m{sup 2} laboratory environments. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Single-view 3D reconstruction of correlated gamma-neutron sources

We describe a new method of 3D image reconstruction of neutron sources that emit correlated gammas (e.g. Cf- 252, Am-Be). This category includes a vast majority of neutron sources important in nuclear threat search, safeguards and non-proliferation. Rather than requiring multiple views of the source this technique relies on the source’s intrinsic property of coincidence gamma and neutron emission. As a result only a single-view measurement of the source is required to perform the 3D reconstruction. In principle, any scatter camera sensitive to gammas and neutrons with adequate timing and interaction location resolution can perform this reconstruction. Using a neutron double scatter technique, we can calculate a conical surface of possible source locations. By including the time to a correlated gamma we further constrain the source location in three-dimensions by solving for the source-to-detector distance along the surface of said cone. As a proof of concept we applied these reconstruction techniques on measurements taken with the the Mobile Imager of Neutrons for Emergency Responders (MINER). Two Cf-252 sources measured at 50 and 60 cm from the center of the detector were resolved in their varying depth with average radial distance relative resolution of 26%. To demonstrate the technique’s potential with an optimized system we simulated the measurement in MCNPX-PoliMi assuming timing resolution of 200 ps (from 2 ns in the current system) and source interaction location resolution of 5 mm (from 3 cm). Furthermore, these simulated improvements in scatter camera performance resulted in radial distance relative resolution decreasing to an average of 11%.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Enhanced information content for three-dimensional localization and tracking using the double-helix point spread function with variable-angle illumination epifluorescence microscopy

The signal-to-noise ratio (SNR) and three-dimensional localization precision of a double helix point spread function (DH-PSF) can be significantly improved by applying variable-angle illumination epifluorescence microscopy (VAI, also commonly known as “pseudo-TIRF” or “quasi-TIRF”). In this paper, we performed a quantitative analysis of the dependence of SNR and localization precision on the number of measured photons and the incident angle for static particles under both low (at a planar index-matched interface) and high (within a porous silica matrix) fluorescent background conditions. We found that under noisier imaging conditions, the SNR and localization precision obtained using VAI are up to fivefold and threefold greater, respectively, than those obtained using epi-illumination. Finally and moreover, we demonstrate that the combination of DH-PSF and VAI can significantly improve the accuracy of the measured diffusion coefficient for mobile particles, even at a relatively large distance (50 μm) from the boundary of the optical cell.

42 ENGINEERING↗

Effects of EMF Emissions from Cables and Junction Boxes on Marine Species

Studies have shown that diverse aquatic species are electrosensitive. Many fishes, and marine mammals, can either detect, navigate by, or are affected by electromagnetic fields (EMF) with various sensitivities, and their behavior may be impacted by unnatural EMF emissions in the water column. Sharks, rays and skates are known to have the highest sensitivity to electric fields. Electric field emissions in the range 0.5–100 micro volt/m appear to attract them, and emissions over 100 micro volt/m to repulse them. A marine hydrokinetic MHK device will have multiple components and associated multiple submarine cables on the seafloor and running through the water column and would potentially increase the level of EMF emissions to which the marine species at the site may be exposed to. There are therefore concerns amongst stakeholders that EMF emissions associated with MHK devices and their components may act as barriers to species migration, cause disorientation, change community compositions and ecosystems, and that they may attract sharks, leading to a local increase in the risk of shark attacks. However, field data to validate and model potential relationships between observed responses and the EMF emissions in situ are sparse. A program of experimental field surveys were conducted off the coast of South Florida, USA to characterize the electromagnetic field (EMF) emissions in the water column from a submarine cable, and to monitor for responses of local aquatic species. The field surveys were conducted at the South Florida Ocean Measurement Facility (SFOMF) off Fort Lauderdale, which is a cabled offshore in-water navy range. It consists of multiple active submarine power cables and a number of junction boxes, with the capability to transmit AC/DC power at a range of strength and frequencies. The site includes significant marine life activities and community structure, including highly mobile species, such as sharks, stingrays, mammals and turtles. SFOMF therefore typifies a setting representative of an offshore location where a MHK device may be sited. Background electromagnetic field (EMF) levels and EMF emissions due to submarine cables were measured using a custom E-field sensor and a commercial magnetometer deployed from an autonomous underwater vehicle (AUV) at various fixed altitudes above the seafloor. EMF signatures detected from power cables and junction boxes are contrasted against ambient background levels and other EMF sources. The potential responses of local marine species were observed at selected representative locations using divers on SCUBA, complemented with fixed cameras on the sea bottom and by a set of video cameras mounted on the AUV. The objectives of the study were: 1) to characterize the EMF emission levels associated with submarine cables 2) to monitor potential responses of aquatic animals to the emissions and 3) to develop an associated database of field observations. As control, observations of EMF levels and in situ marine species were conducted with power in the cable turned off. Good quality measurements of EMF emissions were obtained using the mobile AUV platform and the data from the surveys were used to develop contour maps of the EMF levels in the water column above the live cable as well as to provide information about how the field decays away from the cable. The measurements show good agreement with theoretical models of the how EMF levels decay away from the cable in deep and shallow water environment. Electric fields in excess of 200µV/m were measured in the vicinity of the cable during the power on state. Quarterly surveys by SCUBA divers were conducted, using point and transect count methods, over a period of one year at three locations, one at a shallow site where the water depth is approximately 5m, and the other at the Barracuda Reef where the water depth is approximately 10m. The sampling results were analyzed to determine if the presence of an SFOMF generated EMF alters: (1) abundance, species richness, and assemblage structure of coral reef fishes, (2) the behavior of fishes including elasmobranchs, and (3) the distribution of marine turtles and mammals. Diver observations were also used in attempt to discern if there were any noticeable organismal responses during the transitional period between ambient OFF to energized AC or DC power states, and video footage was intended to augment the in-situ visual survey data and aid in interpretation of the results. Comparisons are provided between observation datasets between the three sites and between the point and transect count methods. Presence of several individual elasmobranch species, including sharks and stingrays, were recorded during the surveys. No apparent effect on richness could be discerned between the power on and off states. No apparent sudden animal movements were observed during transitions between power states.

16 TIDAL AND WAVE POWER↗

Eastern North Atlantic (ENA) Aerosol Supplementary Site (S1) Data Analysis Report

We present strategies to identify time periods when local aerosol sources impact the data collected at the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility in the Eastern North Atlantic (ENA). Data from the aerosol observing system (AOS) at the Central Facility and a temporary aerosol Supplementary Site (S1) were evaluated. S1 instrumentation was deployed within 0.75 km of the ENA Central Facility (C1) for approximately one year. Two time periods, one during the summer and one during the winter, were examined in support of the Aerosol and Cloud Experiments in the Eastern North Atlantic (ACE-ENA) intensive operating periods (IOPs) in 2017 and 2018. As the criteria for identifying regionally representative data varies based on the specific needs of the user, we present and discuss different strategies using measured aerosol properties and their associated meteorological parameters to isolate periods in AOS data that were impacted by local aerosol at ENA. We identify high-concentration aerosol events at ENA using submicron number concentrations, size distributions, high-time-resolution measurements, and diurnal profiles. An improved understanding of local aerosol to select the optimal aerosol mask was obtained with an understanding of local meteorology during the different seasons. We developed a mathematical algorithm that employs AOS data to mask high-concentration aerosol events at ENA. We validated the ENA Aerosol Mask with aerosol data from C1 and S1 and associated meteorological data. The Supplementary Site was ideal to understand and constrain local aerosol sources within the region. In its absence, collocated data from the ENA AOS could be used to select appropriate parameters to develop an aerosol mask that would limit over- or underestimating the regional baseline aerosol data. When available, associated metadata, such as airport flight logs and visual identification with AOS cameras should also be used to validate the application of an aerosol mask at a new site. Our results confirm the importance of optimizing an aerosol mask prior its application. In the future, the application of an aerosol mask at ARM observatories and during mobile deployments could be used to increase the data quality of continuous AOS data and to reduce uncertainties when parameterizing regional aerosol processes and impacts on clouds for incorporation in models.

54 ENVIRONMENTAL SCIENCES↗

Positive/negative ion velocity mapping apparatus for electron-molecule reactions

In molecular dissociative ionization by electron collisions and dissociative electron attachment to molecule, the respective positively and negatively charged fragments are the important products. A compact ion velocity mapping apparatus is developed for the angular distribution measurements of the positive or negative fragments produced in the electron-molecule reactions. This apparatus consists of a pulsed electron gun, a set of ion velocity mapping optic lenses, a two-dimensional position detector including two pieces of micro-channel plates, and a phosphor screen, and a charge-coupled-device camera for data acquisition. The positive and negative ion detections can be simply realized by changing the voltage polarity of ion optics and detector. Velocity sliced images can be directly recorded using a narrow voltage pulse applied on the rear micro-channel plate. The efficient performance of this system is evaluated by measuring the angular distribution of O{sup -} from the electron attachments to NO at 7.3 and 8.3 eV and O{sup +} from the electron collision with CO at 40.0 eV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scintilla European project, the successful research results

The Scintilla FP7 project is ended in December 2014, the fruitful results of 3 years development and tests will be presented. SCINTILLA offers the capacity to finding a reliable alternative to Helium-3 based detection systems since the gas which is predominantly used in nuclear safeguards and security applications has now become very expensive, rare and nearly unavailable. SCINTILLA benchmarks results are based on international standards. Radiation Portal tests were carried out at the Joint Research Centre (JRC) in Ispra (Italy). The scintilla project addresses few mains issues. The first is to develop neutron detectors for Radiation Portal Monitor (RPM) and the second is the need of new wearable integrated solutions for Spectrometric Personal Radiation Monitor (SPRM). The partners which provide technical systems of the scintilla project are INFN-ANSALDO, CEA, SYMETRICA and SAPHYMO. For RPM, the objective is to find reliable alternatives to Helium-3 historical neutron detector and provide technical solutions which cope with tests for reliable mobile and cost effective. For Spectrometric Personal Radiation Monitor (SPRM), SCINTILLA is innovating in technology areas that offer complementary capabilities for detecting and identifying gamma, Two CZT (Cadmium Zinc Telluride) addressing contexts of used by first responder technologies, one is a wearable detector and the second is a gamma camera complemented by advanced image processing technologies. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

GRDC. A Collaborative Framework for Radiological Background and Contextual Data Analysis

The Radiation Mobile Analysis Platform (RadMAP) is unique in its capability to collect both high quality radiological data from both gamma-ray detectors and fast neutron detectors and a broad array of contextual data that includes positioning and stance data, high-resolution 3D radiological data from weather sensors, LiDAR, and visual and hyperspectral cameras. The datasets obtained from RadMAP are both voluminous and complex and require analyses from highly diverse communities within both the national laboratory and academic communities. Maintaining a high level of transparency will enable analysis products to further enrich the RadMAP dataset. It is in this spirit of open and collaborative data that the RadMAP team proposed to collect, calibrate, and make available online data from the RadMAP system. The Berkeley Data Cloud (BDC) is a cloud-based data management framework that enables web-based data browsing visualization, and connects curated datasets to custom workflows such that analysis products can be managed and disseminated while maintaining user access rights. BDC enables cloud-based analyses of large datasets in a manner that simulates real-time data collection, such that BDC can be used to test algorithm performance on real and source-injected datasets. Using the BDC framework, a subset of the RadMAP datasets have been disseminated via the Gamma Ray Data Cloud (GRDC) that is hosted through the National Energy Research Science Computing (NERSC) Center, enabling data access to over 40 users at 10 institutions.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Influence of lure choice and survey duration on scent stations for carnivore surveys

Abstract Noninvasive, camera‐based, scent station surveys have become a common approach to estimate population parameters for mammalian carnivores. Many carnivores are particularly sensitive to olfactory cues; and, as such, the quality and quantity of odor attractant used during surveys can significantly affect the accuracy and precision of the survey. Additionally, survey length is also an important consideration because many mammalian predators are highly mobile and elusive in nature. Using scent station surveys in autumn 2013 and 2014 on the Savannah River Site, Aiken, South Carolina, USA, we tested the effects of 5 lures: fatty acid, fish oil, synthetic fermented egg, beaver castor, and skunk essence on visitation rates, visitation probability, and latency to visitation of multiple predator species. We also estimated occupancy probability for 2 carnivore species using different survey lengths to determine the effect of survey period on the precision of occupancy estimates. We found that skunk essence had greater visitation probability and visits than other lures evaluated. Species‐specific bait‐preference models revealed that raccoons ( Procyon lotor ) were more likely to visit skunk essence, and coyotes ( Canis latrans ) were less likely to visit fish oil as compared with fatty acid. Latency to visitation ranged from 104.7 to 112.1 hours and did not vary among scents. Longer survey durations resulted in more precise estimates of occupancy and detection probability. Our results suggest a wide range of scents commonly used for carnivore capture may perform as well as, or better than, fatty acid for noninvasive carnivore surveys. Further, study designs should carefully consider the duration of scent‐station surveys depending on the level of precision desired in estimates of occupancy and detection probability. © 2019 The Wildlife Society.

Webster, Sarah C.↗

A mobile system for a comprehensive online-characterization of nanoparticle aggregates based on wide-angle light scattering and laser-induced incandescence

A mobile demonstrator for the comprehensive online-characterization of gas-borne nanoparticle aggregates is presented. Two optical measurement techniques are combined, both utilizing a pulsed Nd:YAG laser as light source. Aggregate size and fractal dimension are measured by Wide-Angle Light Scattering (WALS). An ellipsoidal mirror images elastically scattered light from scattering angles between 10° and 165° onto a CCD-camera chip resulting in an almost complete scattering diagram with high angular resolution. Primary particle size and volume fraction are measured by time-resolved Laser-Induced Incandescence (TiRe-LII). Here, particles are heated up to about 3000 K by the short laser pulse, the enhanced thermal radiation signal is detected with gated photomultiplier tubes. Analysis of the signal decay time and maximum LII-signal allows for the determination of primary particle diameter and volume fraction. The performance of the system is demonstrated by combined measurements on soot nanoparticle aggregates from a soot aerosol generator. Particle and aggregate sizes are varied by using different equivalence ratios of the combustion in the generator. Soot volume fraction can be adjusted by different levels of dilution with air. Online-measurements were carried out demonstrating the favorable performance of the system and the potential for industrial applications such as process control and product development. The particle properties obtained are confirmed through transmission electron microscopy analysis on representative samples.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In-situ transmission electron microscopy study of oxygen vacancy ordering and dislocation annihilation in undoped and Sm-doped CeO 2 ceramics during redox processes

Ceria (CeO 2 ) based ceramics have been widely used for many applications due to their unique ionic, electronic, and catalytic properties. We report our findings in investigating into the redox processes of undoped and Sm-doped CeO 2 ceramics stimulated by high-energy electron beam irradiation within a transmission electron microscope (TEM). The reduced structure with oxygen vacancy ordering has been identified as the CeO 1.68 (C-Ce 2 O 3+δ ) phase via high-resolution TEM. The reduction of Ce 4+ to Ce 3+ has been monitored by electron energy-loss spectroscopy. The decreased electronic conductivity of the Sm-doped CeO 2 (Sm 0.2 Ce 0.8 O 1.9 , SDC) is revealed by electron holography, as positive electrostatic charges accumulated at the surfaces of SDC grains under electron beam irradiation, but not at CeO 2 grains. The formation of the reduced CeO 1.68 domains corresponds to lattice expansion compared to the CeO 2 matrix. Therefore, the growth of CeO 1.68 nuclei builds up strain inside the matrix, causing annihilation of dislocations inside the grains. By using in-situ high-resolution TEM and a fast OneView camera recording system, we investigated dislocation motion inside both CeO 2 and SDC grains under electron beam irradiation. The dislocations prefer to dissociate into Shockley partials bounded by stacking faults. Then, the partials can easily glide in the {111} planes to reach the grain surfaces. Even the Lomer-Cottrell lock can be swept away by the phase change induced strain field. Our results revealed the high mobility of dislocations inside CeO 2 and SDC grains during their respective redox processes

36 MATERIALS SCIENCE↗

Decommissioning of the NPP A-1 heavy water management system - 15121

The paper deals with experience and techniques in the application of decontamination technology and remotely controlled robotic devices for the decontamination and dismantling of the heavy water management system during undergoing decommissioning process of the A-1 NPP as well as treatment of arising liquid waste All of these activities are characterized by high level of radioactivity and contamination. During operation of the A-1 NPP the heavy water management system fulfilled several functions: (1) cooling of the moderator, (2) topping up of the moderator in the active zone, (3) drainage, feed and storage of heavy water, (4) capture of leaked heavy water. Closely associated with heavy water management were systems for separation and isotopic purification of heavy water (distilling station, removing organic impurities station, isotopic purification station). The NPP heavy water system is located inside the power block building in several rooms where the inner surface contamination is up to the level of 10 E4 Bq.cm{sup -2}, dose rate up to 15,0 mGy.h{sup -1} and the feeding pipeline contained liquid RAW with high tritium content. Pre-dismantling decontamination of the heavy water management system and associated systems had to be performed with the intention of improving the radiation situation, i.e. reducing contamination of internal surface and dose rates in the vicinity of the equipment. Various sophisticated procedures such as retrieval of sludge using remotely operated devices and loop chemical decontamination of internal surfaces were applied. The generated radioactive waste such as spent decontamination solutions and sludge were immediately solidified on-site into a geo-polymer matrix using a mobile conditioning facility. For dismantling and fragmentation of some devices, mobile robotic systems MT80 and MT15 were applied which had been developed, designed and constructed as general-purpose decommissioning equipment. Special tooling was developed for application with the robots, such as hydraulic shears, circular saw, reciprocating saw, circular pipe cutter and a system for quick tool-change without direct intervention of the operators. Most of the operations are remotely controlled on basis of visual information from four cameras, with consistent radiation protection of the operators. The implementation of partial decommissioning tasks in such hard and unfavorable radiation conditions (moreover accompanied by generation of specific high-content alpha radwaste) has introduced in practice several new unique decontamination and dismantling techniques and new procedures for the effective on-site processing of generated secondary radioactive waste, including sludge and sorbents. These advantageous techniques, equipment and experience will be exploited in the continuation of the A-1 NPP decommissioning process which has been organized according to distinctively licensed phases and are also being applied in the decommissioning of other NPP in Slovakia as well as abroad. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Infrastructure-Based Cooperative Perception at a Traffic Intersection: Overview and Challenges

Traffic intersections are crucial and challenging nodes in transportation networks where multiple lanes of vehicles and pedestrians converge. About one-quarter of traffic fatalities and about one-half of all traffic injuries in the United States happen at traffic intersections . Effective management of these intersections is important to ensure safety and efficiency of all users - vehicles, pedestrians, cyclists, and vulnerable road users (VRUs). With advancements in sensor perception technologies such as radar, light detection and ranging (lidar), and cameras, traffic intersections are developing into dynamic and data-rich environments. By using these data to create a real-time digital twin, we can enable real-time data-driven decision making and a range of applications such as sharing perception information to connected vehicles (CVs) and connected autonomous vehicles (CAVs), safety affirmative signaling, and curb optimizing to improve efficiency and enhance safety.This paper presents an overview of the concept and examines the challenges involved in implementing an infrastructure-based cooperative perception engine at a traffic intersection. In addition to outlining the physical components, this study also addresses important challenges involved in a multi-sensor system. We present results from deploying the National Renewable Energy Laboratory's (NREL's) Infrastructure Perception and Control (IPC) mobile trailer at a traffic intersection in the city of Colorado Springs, Colorado, USA that employed multiple radars and lidars to capture the data. This study provides necessary practical learning for the Cooperative Driving Automation (CDA) and traffic engineering communities for next-generation infrastructure-based cooperative perception that promises improvements in signal control for optimized traffic flow, among other applications, and documents findings for ongoing research and development efforts in other areas.

ADVANCED PROPULSION SYSTEMS,MATHEMATICS AND COMPUT↗