Search NASA⌕ Search

SEARCH · Search NASA

Results for “camera system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

The Feasibility of Motion Tracking Camera System for Magnetic Suspension Wind Tunnel Tests

The Entry Systems Modeling (ESM) Program at NASA has actively participated in the re-development of the Magnetic Suspension Balance System (MSBS) at the six-inch subsonic wind tunnel at NASA Langley Research Center. This initiative aims to enhance the MSBS system's capabilities, enabling the testing of stingless entry vehicle models at supersonic speeds. To achieve this, control algorithms are required to ensure magnetic levitation control and stability for models during free-oscillation dynamic responses. Currently, the system relies on electromagnetic position sensors to provide real-time 3 degrees of freedom in a rigid body. While this approach has proven successful for subsonic speeds, expanding testing under higher pressure conditions may necessitate the incorporation of real-time roll and pitch measurements to quantify the dynamic stability characteristics of the models in free-oscillation. In collaboration with Old Dominion University, the team at NASA Langley Research Center proposes the implementation of a motion-tracking camera system. This system will provide real-time five degrees of freedom output, which will be utilized within a closed feedback control system and a two-step system identification model to isolate aerodynamic forces from their corresponding magnetic forces. The motion-tracking cameras will offer precise and accurate control over the levitation system, facilitating precise and repeatable experiments within the wind tunnel. The real-time feedback provided by the cameras enables prompt adjustments to ensure the maintenance of stable levitation throughout the testing process.

Entry Systems Modeling↗

Characterizing Digital Camera Systems: A Prelude to Data Standards

This viewgraph presentation profiles: 1) Digital imaging systems; 2) Specifying a digital imagery product; and 3) Characterization of data acquisition systems. Advanced large array digital imaging systems are routinely being used. Digital imagery guidelines are being developed by ASPRS and ISPRS. Guidelines and standards are of little use without standardized characterization methods. Characterization of digital camera systems is important for supporting digital imagery guidelines. Specifications are characterized in the lab and/or the field. Laboratory characterization is critical for optimizing and defining performance. In-flight characterization is necessary for an end-to-end system test.

Ryan, Robert↗

In-situ visual inspection of the CASTOR V/21 used nuclear fuel dry storage cask: a demonstration of camera system capabilities - 15505

On June 11, 2014 the Gesellschaft fur Nuklear Service (GNS) CASTOR V/21 spent fuel dry storage cask was inspected in-situ at the Idaho Nuclear Technology and Engineering Center (INTEC). The purpose of this inspection is to demonstrate and document the technology necessary to perform inspections of spent fuel dry storage casks. The inspection includes internal temperature measurement, internal radiation measurement, and a visual examination using a bore-scope type camera system inserted through the cask fill/drain penetration. It is concluded from this inspection that in-situ inspections of bolted lid spent fuel storage containers is possible using current camera technologies. Using 3D Phase Measurement Technology, measurements of entities such as cracks or corrosion are possible. The internal surfaces of the CASTOR V/21 cask that were inspected were free of corrosion and exhibited no evidence of degradation. One crack identified in previous inspections was examined and appeared the same as in the previous inspections. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A low noise CMOS camera system for 2D resonant inelastic soft X-ray scattering

Resonant Inelastic X-ray Scattering (RIXS) is a powerful spectroscopic technique to study quantum properties of materials in the bulk. A novel variant of RIXS, called 2D RIXS, enables concurrent measurement of the scattered X-ray spectrum for a wide range of input energies, improving on the typically low throughput of 1D RIXS. In the soft X-ray domain, 2D RIXS demands an X-ray camera system with small pixels, large area, high quantum efficiency and low noise to limit the false detection rate in long duration exposures. We designed and implemented a 7.5 Megapixel back-illuminated CMOS detector with 5 μm pixels and high quantum efficiency in the 200–1,000 eV X-ray energy range for the QERLIN 2D RIXS spectrometer at the Advanced Light Source. The QERLIN beamline and detector are currently in commissioning. The camera noise from in-situ 3 s long dark exposures is 7e - or less and the leakage current is 6.5 × 10 -3 e - /(pixel ∙ s). For individual 500 eV X-rays, the expected efficiency is greater than 75% and the false detection rate is ~1 × 10 -5 per pixel.

47 OTHER INSTRUMENTATION↗

A Quasi-Static Method for Determining the Characteristics of a Motion Capture Camera System in a "Split-Volume" Configuration

To confidently report any data collected from a video-based motion capture system, its functional characteristics must be determined, namely accuracy, repeatability and resolution. Many researchers have examined these characteristics with motion capture systems, but they used only two cameras, positioned 90 degrees to each other. Everaert used 4 cameras, but all were aligned along major axes (two in x, one in y and z). Richards compared the characteristics of different commercially available systems set-up in practical configurations, but all cameras viewed a single calibration volume. The purpose of this study was to determine the accuracy, repeatability and resolution of a 6-camera Motion Analysis system in a split-volume configuration using a quasistatic methodology.

Miller, Chris↗

A Novel 24 Ghz One-Shot Rapid and Portable Microwave Imaging System (Camera)

A novel 2D microwave imaging system at 24 GHz based on MST techniques. Enhanced sensitivity and SNR by utilizing PIN diode-loaded resonant slots. Specific slot and array design to increase transmission and reduce cross -coupling. Real-time imaging at a rate in excess of 30 images per second. Reflection as well transmission mode capabilities. Utility and application for electric field distribution mapping related to: Nondestructive Testing (NDT), imaging applications (SAR, Holography), and antenna pattern measurements.

Ghasr, M.T.↗

Camera system resolution and its influence on digital image correlation

Digital image correlation (DIC) uses images from a camera and lens system to make quantitative measurements of the shape, displacement, and strain of test objects. This increasingly popular method has had little research on the influence of the imaging system resolution on the DIC results. This paper investigates the entire imaging system and studies how both the camera and lens resolution influence the DIC results as a function of the system Modulation Transfer Function (MTF). It will show that when making spatial resolution decisions (including speckle size) the resolution limiting component should be considered. A consequence of the loss of spatial resolution is that the DIC uncertainties will be increased. This is demonstrated using both synthetic and experimental images with varying resolution. The loss of image resolution and DIC accuracy can be compensated for by increasing the subset size, or better, by increasing the speckle size. The speckle-size and spatial resolution are now a function of the lens resolution rather than the more typical assumption of the pixel size. The study will demonstrate the tradeoffs associated with limited lens resolution.

47 OTHER INSTRUMENTATION↗

Metrology Camera System Using Two-Color Interferometry

A metrology system that contains no moving parts simultaneously measures the bearings and ranges of multiple reflective targets in its vicinity, enabling determination of the three-dimensional (3D) positions of the targets with submillimeter accuracy. The system combines a direction-measuring metrology camera and an interferometric range-finding subsystem. Because the system is based partly on a prior instrument denoted the Modulation Sideband Technology for Absolute Ranging (MSTAR) sensor and because of its 3D capability, the system is denoted the MSTAR3D. Developed for use in measuring the shape (for the purpose of compensating for distortion) of large structures like radar antennas, it can also be used to measure positions of multiple targets in the course of conventional terrestrial surveying. A diagram of the system is shown in the figure. One of the targets is a reference target having a known, constant distance with respect to the system. The system comprises a laser for generating local and target beams at a carrier frequency; a frequency shifting unit to introduce a frequency shift offset between the target and local beams; a pair of high-speed modulators that apply modulation to the carrier frequency in the local and target beams to produce a series of modulation sidebands, the highspeed modulators having modulation frequencies of FL and FM; a target beam launcher that illuminates the targets with the target beam; optics and a multipixel photodetector; a local beam launcher that launches the local beam towards the multi-pixel photodetector; a mirror for projecting to the optics a portion of the target beam reflected from the targets, the optics being configured to focus the portion of the target beam at the multi-pixel photodetector; and a signal-processing unit connected to the photodetector. The portion of the target beam reflected from the targets produces spots on the multi-pixel photodetector corresponding to the targets, respectively, and the signal-processing unit centroids the spots to determine bearings of the targets, respectively. As the spots oscillate in intensity because they are mixed with the local laser beam that is flood illuminating the focal plane, the phase of oscillation of each spot is measured, the phase of sidebands in the oscillation of each spot being proportional to a distance to the corresponding target relative to the reference target A.

Dubovitsky, Serge↗

Outer planet investigations using a CCD camera system

Problems related to analog noise, data transfer from the camera buffer to the storage computer, and loss of sensitivity of a two dimensional charge coupled device imaging system are reported. To calibrate the CCD system, calibrated UBV pinhole scans of the Saturn disk were obtained with a photoelectric area scanning photometer. Atmospheric point spread functions were also obtained. The UBV observations and models of the Saturn atmosphere are analyzed.

Price, M. J.↗

Design and initial operation of a two-color soft x-ray camera system on the Compact Toroidal Hybrid experiment

A multi-camera soft x-ray diagnostic has been developed to measure the equilibrium electron temperature profile and temperature fluctuations due to magnetohydrodynamic activity on the Compact Toroidal Hybrid experiment. The diagnostic consists of three separate cameras each employing two 20-channel diode arrays that view the same plasma region through different beryllium filter thicknesses of 1.8 μm and 3.0 μm allowing electron temperature measurements between 50 eV and 200 eV. The Compact Toroidal Hybrid is a five-field period current-carrying stellarator, in which the presence of plasma current strongly modifies the rotational transform and degree of asymmetry of the equilibrium. Details of the soft x-ray emission, effects of plasma asymmetry, and impurity line radiation on the design and measurement of the two-color diagnostic are discussed. Preliminary estimates of the temperature perturbation due to sawtooth oscillations observed in these hybrid discharges are given.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A quasi-static method for determining the characteristics of a motion capture camera system in a "split-volume" configuration

The purpose of this study was to determine the accuracy, repeatability and resolution of a six-camera Motion Analysis system in a vertical split-volume configuration using a unique quasi-static methodology. The position of a reflective marker was recorded while it was moved quasi-statically over a range of 2.54 mm (0.100 inches) via a linearly-translating table. The table was placed at five different heights to cover both sub-volumes and the overlapping region. Data analysis showed that accuracy, repeatability and resolution values were consistent across all regions of the split-volume, including the overlapping section.

NASA Center JSC↗

The DESI Fiber View Camera System

The Dark Energy Spectroscopic Instrument (DESI) is a 5000 fiber multi-object spectrometer now being installed at the prime focus of the 4 m Mayall telescope at Kitt Peak. Using DESI to measure ~35 million galaxy redshifts and using the Baryon Acoustic Oscillation (BAO) technique to measure distances, the results will probe the nature of the recently discovered mysterious component of our universe called dark energy. Computer controlled robotic positioners move the 120 μm diameter fibers to positions of galaxies whose location on the sky have been obtained in a previous target selection imaging survey. To achieve good throughput the fibers should be centered on the target position to within 3 μm. The robotic positioners however are only capable of a 50 μm precision on their first move. To achieve the desired precision, the Fiber View Camera (FVC) system has been implemented. The FVC, located near the hole in the primary mirror of the Mayall telescope, has been designed to take an exposure of the focal plane, located at the prime focus some 12 m above the FVC, after the robotic positioners have completed their first move. The FVC is intended to measure the fiber locations with a precision of 3 μm and issue a set of fiber coordinate corrections for the second move correcting the fiber positions by the robotic positioners. Tests show that after two iterations better than 99% of the fibers will be in their intended location to within the desired precision. This paper describes the design of the FVC system, the R&D program preceding the final design, and the tests that have been carried out to demonstrate that the FVC can achieve the required precision.

(cosmology:) dark energy↗

Development of a high-speed H-alpha camera system for the observation of rapid fluctuations in solar flares

A solid-state digital camera was developed for obtaining H alpha images of solar flares with 0.1 s time resolution. Beginning in the summer of 1988, this system will be operated in conjunction with SMM's hard X-ray burst spectrometer (HXRBS). Important electron time-of-flight effects that are crucial for determining the flare energy release processes should be detectable with these combined H alpha and hard X-ray observations. Charge-injection device (CID) cameras provide 128 x 128 pixel images simultaneously in the H alpha blue wing, line center, and red wing, or other wavelength of interest. The data recording system employs a microprocessor-controlled, electronic interface between each camera and a digital processor board that encodes the data into a serial bitstream for continuous recording by a standard video cassette recorder. Only a small fraction of the data will be permanently archived through utilization of a direct memory access interface onto a VAX-750 computer. In addition to correlations with hard X-ray data, observations from the high speed H alpha camera will also be correlated and optical and microwave data and data from future MAX 1991 campaigns. Whether the recorded optical flashes are simultaneous with X-ray peaks to within 0.1 s, are delayed by tenths of seconds or are even undetectable, the results will have implications on the validity of both thermal and nonthermal models of hard X-ray production.

Kiplinger, Alan L.↗

Infrared Camera System for Visualization of IR-Absorbing Gas Leaks

Leak detection and location remain a common problem in NASA and industry, where gas leaks can create hazardous conditions if not quickly detected and corrected. In order to help rectify this problem, this design equips an infrared (IR) camera with the means to make gas leaks of IR-absorbing gases more visible for leak detection and location. By comparing the output of two IR cameras (or two pictures from the same camera under essentially identical conditions and very closely spaced in time) on a pixel-by-pixel basis, one can cancel out all but the desired variations that correspond to the IR absorption of the gas of interest. This can be simply done by absorbing the IR lines that correspond to the gas of interest from the radiation received by one of the cameras by the intervention of a filter that removes the particular wavelength of interest from the "reference" picture. This can be done most sensitively with a gas filter (filled with the gas of interest) placed in front of the IR detector array, or (less sensitively) by use of a suitable line filter in the same location. This arrangement would then be balanced against the unfiltered "measurement" picture, which will have variations from IR absorption from the gas of interest. By suitable processing of the signals from each pixel in the two IR pictures, the user can display only the differences in the signals. Either a difference or a ratio output of the two signals is feasible. From a gas concentration viewpoint, the ratio could be processed to show the column depth of the gas leak. If a variation in the background IR light intensity is present in the field of view, then large changes in the difference signal will occur for the same gas column concentration between the background and the camera. By ratioing the outputs, the same signal ratio is obtained for both high- and low-background signals, even though the low-signal areas may have greater noise content due to their smaller signal strength. Thus, one embodiment would use a ratioed output signal to better represent the gas column concentration. An alternative approach uses a simpler multiplication of the filtered signal to make the filtered signal equal to the unfiltered signal at most locations, followed by a subtraction to remove all but the wavelength-specific absorption in the unfiltered sample. This signal processing can also reveal the net difference signal representing the leaking gas absorption, and allow rapid leak location, but signal intensity would not relate solely to gas absorption, as raw signal intensity would also affect the displayed signal. A second design choice is whether to use one camera with two images closely spaced in time, or two cameras with essentially the same view and time. The figure shows the two-camera version. This choice involves many tradeoffs that are not apparent until some detailed testing is done. In short, the tradeoffs involve the temporal changes in the field picture versus the pixel sensitivity curves and frame alignment differences with two cameras, and which system would lead to the smaller variations from the uncontrolled variables.

Youngquist, Robert↗

Camera Systems Rapidly Scan Large Structures

Needing a method to quickly scan large structures like an aircraft wing, Langley Research Center developed the line scanning thermography (LST) system. LST works in tandem with a moving infrared camera to capture how a material responds to changes in temperature. Princeton Junction, New Jersey-based MISTRAS Group Inc. now licenses the technology and uses it in power stations and industrial plants.

Source record↗