Search NASA⌕ Search

SEARCH · Search NASA

Results for “capacitance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Capacitive response of biological membranes

We present a minimal model to analyze the capacitive response of a biological membrane subjected to a step voltage via blocking electrodes. Through a perturbative analysis of the underlying electrolyte transport equations, we show that the leading-order relaxation of the transmembrane potential is governed by a capacitive timescale, τ_{C}=λ_{D}L/D(2+Γδ^{M}/L/4+Γδ^{M}/λ_{D}), where λ_{D} is the Debye screening length, L is the electrolyte width, Γ is the ratio of the permittivity of the electrolyte to the membrane, δ^{M} is the membrane thickness, and D is the ionic diffusivity. This timescale is considerably shorter than the traditional RC timescale λ_{D}L/D for a bare electrolyte due to the membrane's low permittivity and finite thickness. Beyond the linear regime, however, salt diffusion in the bulk electrolyte drives a secondary, nonlinear relaxation process of the transmembrane potential over a longer timescale τ_{L}=L^{2}/4π^{2}D. A simple equivalent-circuit model accurately captures the linear behavior, and the perturbation expansion remains applicable across the entire range of observed physiological transmembrane potentials. Together, these findings underscore the importance of the faster capacitive timescale and nonlinear effects on the bulk diffusion timescale in determining transmembrane potential dynamics for a range of biological systems.

Farhadi, Jafar↗

Comparison of the Capacitances and Switching Losses of 1.2 kV Common-Source and Common- Drain Bidirectional Switch Topologies

Bidirectional, or four-quadrant switches (FQS) can be designed as back-to-back MOSFETs connected in common-drain (CD) or common-source (CS) topologies. CDFQS and CS-FQS assembled from discrete 1.2 kV commercially available SiC power MOSFETs were characterized to obtain capacitance and switching loss values. The CD-FQS exhibited a 1.17x larger turn-on loss compared to the CS-FQS, while the CS-FQS exhibited a 1.52x larger turn-off loss compared to the CD-FQS. The CS-FQS exhibited a lower input capacitance, while the CD-FQS exhibited a lower output and reverse transfer capacitance.

Silicon Carbide, Bidirectional Switch, Switching P↗

A Review: Flow Electrode Capacitive Deionization for Improved Electrochemical Water Desalination

In many places of the world people have continued to suffer from major droughts and water shortages. With climate change climbing in intensity, these dry conditions will only worsen. With much of the world’s water in the ocean, both saltwater and brackish water have been identified as key water sources. Currently, there are several technologies available for water desalination and treatment such as reverse osmosis, capacitive deionization, electrodialysis, and flow electrode capacitive deionization. This paper will briefly review each of these technologies and propose a new design to improve the current flow electrode capacitive deionization architecture. The new design uses a current collector flow-electrode architecture that has the potential to achieve record thermodynamic energy efficiencies. This formulation is proprietary to Lawrence Livermore National Laboratory.

36 MATERIALS SCIENCE↗

Dynamic Capacitive Wireless Power Transfer System for Electric Vehicles (CRADA Final Report)

Road transportation accounts for 23% of our nation's total energy consumption, 59% of our petroleum consumption and 22% of our total emissions. Electric vehicles (EVs) have much higher well-to-wheel efficiency compared to gasoline vehicles and can reduce our dependence on oil, minimize emissions, improve local air quality and provide a platform for technological innovation and economic growth. While major progress has been made in the development of electric vehicles, their penetration remains under 1 The main hurdles in their widespread adoption are high cost, limited range and long charging times, due to limitations in battery technology. An approach to overcome these hurdles is to substantially reduce the on-board energy storage and instead deliver power wirelessly to the vehicle while it is in motion dynamic wireless power transfer (WPT). For EV charging applications, researchers have traditionally focused on inductive WPT. An issue with inductive WPT systems is that for magnetic flux guidance and shielding, they require ferrite cores, making them expensive, bulky and difficult to embed in the roadway. Under an ARPA-E IDEAS grant, the CU Boulder team has recently developed an alternative approach to WPT based on capacitive coupling that is much smaller, lighter, less expensive, and easier to embed in the roadway than inductive WPT; and have demonstrated a 1.2-kW 6.78-MHz version of this capacitive WPT system on a stationary platform. Under this seed grant program, preliminary work will be carried out on a dynamic capacitive WPT system to prepare a strong proposal for the ARPA-E OPEN 2018 FOA.

33 ADVANCED PROPULSION SYSTEMS↗

The Dopamine Assisted Synthesis of MoO3/Carbon Electrodes With Enhanced Capacitance in Aqueous Electrolyte

A capacitance increase phenomenon is observed for MoO 3 electrodes synthesized via a sol-gel process in the presence of dopamine hydrochloride (Dopa HCl) as compared to α-MoO 3 electrodes in 5M ZnCl 2 aqueous electrolyte. The synthesis approach is based on a hydrogen peroxide-initiated sol-gel reaction to which the Dopa HCl is added. The powder precursor (Dopa) x MoO y , is isolated from the metastable gel using freeze-drying. Hydrothermal treatment (HT) of the precursor results in the formation of MoO 3 accompanied by carbonization of the organic molecules; designated as HT-MoO 3 /C. HT of the precipitate formed in the absence of dopamine in the reaction produced α-MoO 3 , which was used as a reference material in this study (α-MoO 3 -ref). Scanning electron microscopy (SEM) images show a nanobelt morphology for both HT-MoO 3 /C and α-MoO 3 -ref powders, but with distinct differences in the shape of the nanobelts. The presence of carbonaceous content in the structure of HT-MoO 3 /C is confirmed by FTIR and Raman spectroscopy measurements. X-ray diffraction (XRD) and Rietveld refinement analysis demonstrate the presence of α-MoO 3 and h-MoO 3 phases in the structure of HT-MoO 3 /C. The increased specific capacitance delivered by the HT-MoO 3 /C electrode as compared to the α-MoO 3 -ref electrode in 5M ZnCl 2 electrolyte in a −0.25–0.70 V vs. Ag/AgCl potential window triggered a more detailed study in an expanded potential window. In the 5M ZnCl 2 electrolyte at a scan rate of 2 mV s −1 , the HT-MoO 3 /C electrode shows a second cycle capacitance of 347.6 F g −1 . The higher electrochemical performance of the HT-MoO 3 /C electrode can be attributed to the presence of carbon in its structure, which can facilitate electron transport. Our study provides a new route for further development of metal oxides for energy storage applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Developing capacitated p-median location-allocation model in the spopt library to allow UCL student teacher placements using public transport

Location-allocation is a key tool within the GIS and network analysis toolbox. In this paper we discuss the real world application of a location-allocation case study (approx 800 students, 500 schools) from UCL using public transport. The use of public transportation is key for this case study, as many location-allocation approaches only make use of drive-time or walking-time distances, but the location of UCL in Greater London, UK makes the inclusion of public transport vital for this case study. The location-allocation is implemented as a capacitated p-median location-allocation model, using the spopt library, part of the Python Spatial Analysis Library (PySAL). The capacitated variation of the p-median location-allocation problem is a new addition to the spopt library, which this work will present. The results from the initial version of the capacitated p-median location-allocation problem has shown a marked improvement on public transport travel time, with public transport travel time reduced by 891 minutes overall for an initial sample of 93 students (9.58 minutes per student). Results will be presented below and plans for further improvement shared.

Bearman, Nick↗

A capacitive accelerometer suitable for telemetry

The design and development of a miniature 0.635 cm (0.25 in.) diameter capacitive accelerometer for use in free flight wind tunnel telemetry are presented. Instruments with full scale ranges from + or - 1 to + or - 200 g were constructed, calibrated, and used in several wind tunnel telemetry projects. Flat, high frequency response from 0 to 1000 Hz or more was obtained by employing the inherent damping and stiffness in the air film surrounding the diaphragm-type spring that supports the inertial mass of the accelerometer. Design features to achieve minimum off-axis sensitivity and temperature stability are discussed, and the design requirements for use of the transducer with telemetry systems are derived. A transducer capacitance change of 0.16 pF full scale gave excellent resolution and provided a frequency deviation of 0.75 MHz for a 100 MHz FM oscillator. Although the present design of the capacitive accelerometer was optimized by using units of 0.635 cm diameter, construction of experimental accelerometers as small as 0.36 cm (0.14 in.) diameter has demonstrated the feasibility of further miniaturization.

Coon, G. W.↗

Optical and transient capacitance study of EL2 in the absence and presence of other midgap levels

A high-resolution optical study was carried out on GaAs crystals grown by horizontal Bridgman and liquid-encapsulated-Czochralski methods. An excellent correlation was found between the intensity of the 1.039-eV no-phonon line and the characteristic absorption of EL2, the major deep donor level in GaAs. A correlation was also found between the characteristic optical absorption of EL2 and its concentration as determined by junction capacitance measurements. The presence of EL0, another midgap level contained in heavily oxygen-doped crystals at concentration always less than those of EL2, had no effect on the optical spectra, but altered the capacitance measurements. Accordingly, an accurate calibration for the determination of EL2 by optical absorption was obtained from capacitance measurements on crystals containing only EL2; in this way the uncertainties introduced by other midgap levels were eliminated.

Skowronski, M.↗

Sliding Capacitive Displacement Transducer

Simple circuit replaces bridge circuit. Sliding capacitive displacement transducer, capacitance varies linearly with displacement, enables use of simple circuit based on operational amplifier instead of complicated capacitance bridge. With new circuit, transducers as small as 0.05 in. (1.3 mm) square and 0.004 in. (0.1 mm) thick have produced output-voltage changes of about 200 mV per 0.005 in. (0.13 mm) of displacement. Piston-type transducer made quite small for installation in confined spaces.

Bryner, B. D.↗

A capacitive technique for real-time monitoring polymer coating thickness on carbon filaments during prepregging process

A technique for gauging the coating thickness during prepreg processing of carbon fibers was developed. It is based on the concept of measuring the capacitance of a cylindrical condenser through which a bundle of prepregged fibers is passed axially. Empirical results indicate the capacitance of this condenser element is linearly related to the polymer coating thickness on the fibers in the bundle. The capacitive transducer was successfully used to measure the polymer thickness on several test fiber bundles under static conditions.

Eftekhari, Abe↗

Study of the capacitance technique for measuring high-temperature blade tip clearance on ceramic rotors

Higher operating temperatures required for increased engine efficiency can be achieved by using ceramic materials for engine components. Ceramic turbine rotors are subject to the same limitations with regard to gas path efficiency as their superalloy predecessors. In this study, a modified frequency-modulation system is proposed for the measurement of blade tip clearance on ceramic rotors. It is expected to operate up to 1370 C (2500 F), the working temperature of present engines with ceramic turbine rotors. The design of the system addresses two special problems associated with nonmetallic blades: the capacitance is less than that of a metal blade and the effects of temperature may introduce uncertainty with regard to the blade tip material composition. To increase capacitance and stabilize the measurement, a small portion of the rotor is modified by the application of 5-micron-thick platinum films. The platinum surfaces on the probe electrodes and rotor that are exposed to the high-velocity gas stream are coated with an additional 10-micron-thick protective ceramic topcoat. A finite-element method is applied to calculate the capacitance as a function of clearance.

Barranger, John P.↗

On Machine Capacitance Dimensional and Surface Profile Measurement System

A program was awarded under the Air Force Machine Tool Sensor Improvements Program Research and Development Announcement to develop and demonstrate the use of a Capacitance Sensor System including Capacitive Non-Contact Analog Probe and a Capacitive Array Dimensional Measurement System to check the dimensions of complex shapes and contours on a machine tool or in an automated inspection cell. The manufacturing of complex shapes and contours and the subsequent verification of those manufactured shapes is fundamental and widespread throughout industry. The critical profile of a gear tooth; the overall shape of a graphite EDM electrode; the contour of a turbine blade in a jet engine; and countless other components in varied applications possess complex shapes that require detailed and complex inspection procedures. Current inspection methods for complex shapes and contours are expensive, time-consuming, and labor intensive.

Resnick, Ralph↗

Capacitive Measurement Of Coating Thickness On Carbon Fibers

Technique for gauging coating thickness during prepreg processing of carbon fibers developed. Technique based on measurement of capacitance of cylindrical condenser through which bundle of prepregged fibers passed axially. Empirical results indicate capacitance linearly related to thickness of polymer coat on fibers in bundle. Capacitive transducer used successfully to measure thickness of polymer coats on several test bundles of fibers under static conditions.

Eftekhari, Abe↗

Active Targets For Capacitive Proximity Sensors

Lightweight, low-power active targets devised for use with improved capacitive proximity sensors described in "Capacitive Proximity Sensor Has Longer Range" (GSC-13377), and "Capacitive Proximity Sensors With Additional Driven Shields" (GSC-13475). Active targets are short-distance electrostatic beacons; they generate known alternating electro-static fields used for alignment and/or to measure distances.

Jenstrom, Del T.↗

Improved Capacitive Liquid-Level Probe

Improved capacitive probe designed to measure level of dielectric liquid in tank. In original application, liquid is hydrogen at low temperature, but design principles applicable to measurement of levels of other dielectric liquids in various temperature ranges. Outstanding features of design those making probe insensitive to temperature-induced and other spurious capacitive effects that otherwise distort capacitive liquid-level readings, and those making it possible to calibrate probe mostly by calculation from first principles.

Ziemke, Robert A.↗

Correcting For Capacitance In Tests Of Solar Cells

Modified procedure for testing solar photovoltaic cells and modified software for processing test data provide corrections for effects of cell capacitance. Procedure and software needed because (a) some photovoltaic devices (for example, silicon solar cells with back-surface field region) store minority charge carriers in cell junction and thus exhibit significant capacitance, (b) capacitance affects current-vs.-voltage (I-V) measurements made when transient load connected to cell, and (c) transient load used in unmodified version of test procedure. Corrected I-V curve obtained in test of solar cell according to modified procedure approximates true cell voltage vs. cell current more closely.

Mueller, Robert L.↗

Design and Laboratory Validation of a Capacitive Sensor for Measuring the Recession of Thin-Layered Ablator

Flight vehicles are typically instrumented with subsurface thermocouples to estimate heat transfer at the surface using inverse analysis procedures. If the vehicle has an ablating heat shield, however, temperature time histories from subsurface thermocouples no longer provide enough information to estimate heat flux at the surface. In this situation, the geometry changes and thermal energy leaves the surface in the form of ablation products. The ablation rate is required to estimate heat transfer to the surface. A new concept for a capacitive sensor has been developed to measure ablator depth using the ablator's dielectric effect on a capacitor's fringe region. Relying on the capacitor's fringe region enables the gage to be flush mounted in the vehicle's permanent structure and not intrude into the ablative heat shield applied over the gage. This sensor's design allows nonintrusive measurement of the thickness of dielectric materials, in particular, the recession rates of low-temperature ablators applied in thin (0.020 to 0.060 in. (0.05 to 0.15 mm)) layers. Twenty capacitive gages with 13 different sensing element geometries were designed, fabricated, and tested. A two-dimensional finite-element analysis was performed on several candidate geometries. Calibration procedures using ablator-simulating shims are described. A one-to-one correspondence between system output and dielectric material thickness was observed out to a thickness of 0.055 in. (1.4 mm) for a material with a permittivity about three times that of air or vacuum. A novel method of monitoring the change in sensor capacitance was developed. This technical memorandum suggests further improvements in gage design and fabrication techniques.

Gregory K Noffz↗

On the Relationship Between Schottky Barrier Capacitance and Mixer Performance at Cryogenic Temperatures

The flat-band voltage is the Schottky junction voltage required to shrink the depletion width to zero. At cryogenic temperatures, mixer diodes are generally biased and/or pumped beyond the flat-band condition to minimize conversion loss and noise figure. This occurs despite the presumed sharp increase in junction capacitance near flat-band, which should instead limit mixer performance. Past moderate forward bias, the diode C-V relationship is difficult to measure. A simple analytic expression for C(V) is usually used to model and predict mixer performance. This letter provides experimental data on C(V) at 77 K based on a microwave measurement and modeling technique. Data is also provided on the conversion loss of a singly balanced mixer optimized for 77 K operation. The connection between junction capacitance, flat-band potential, and conversion loss is examined. It is shown that the analytic expression greatly overestimates the junction capacitance that occurs as flat-band is approached.

Romanofsky, Robert R.↗