Search NASA⌕ Search

SEARCH · Search NASA

Results for “cell imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Altering the cellular mechanical force balance results in integrated changes in cell, cytoskeletal and nuclear shape

Studies were carried out with capillary endothelial cells cultured on fibronectin (FN)-coated dishes in order to analyze the mechanism of cell and nuclear shape control by extracellular matrix (ECM). To examine the role of the cytoskeleton in shape determination independent of changes in transmembrane osmotic pressure, membranes of adherent cells were permeabilized with saponin (25 micrograms/ml) using a buffer that maintains the functional integrity of contractile microfilaments. Real-time videomicroscopic studies revealed that addition of 250 microM ATP resulted in time-dependent retraction and rounding of permeabilized cells and nuclei in a manner similar to that observed in intact living cells following detachment using trypsin-EDTA. Computerized image analysis confirmed that permeabilized cells remained essentially rigid in the absence of ATP and that retraction was stimulated in a dose-dependent manner as the concentration of ATP was raised from 10 to 250 microM. Maximal rounding occurred by 30 min with projected cell and nuclear areas being reduced by 69 and 41%, respectively. ATP-induced rounding was also accompanied by a redistribution of microfilaments resulting in formation of a dense net of F-actin surrounding retracted nuclei. Importantly, ATP-stimulated changes in cell, cytoskeletal, and nuclear form were prevented in permeabilized cells using a synthetic myosin peptide (IRICRKG) that has been previously shown to inhibit actomyosin filament sliding in muscle. In contrast, both the rate and extent of cell and nuclear rounding were increased in permeabilized cells exposed to ATP when the soluble FN peptide, GRGDSP, was used to dislodge immobilized FN from cell surface integrin receptors.(ABSTRACT TRUNCATED AT 250 WORDS).

Non-NASA Center↗

Ionizing radiation induces heritable disruption of epithelial cell interactions

Ionizing radiation (IR) is a known human breast carcinogen. Although the mutagenic capacity of IR is widely acknowledged as the basis for its action as a carcinogen, we and others have shown that IR can also induce growth factors and extracellular matrix remodeling. As a consequence, we have proposed that an additional factor contributing to IR carcinogenesis is the potential disruption of critical constraints that are imposed by normal cell interactions. To test this hypothesis, we asked whether IR affected the ability of nonmalignant human mammary epithelial cells (HMEC) to undergo tissue-specific morphogenesis in culture by using confocal microscopy and imaging bioinformatics. We found that irradiated single HMEC gave rise to colonies exhibiting decreased localization of E-cadherin, beta-catenin, and connexin-43, proteins necessary for the establishment of polarity and communication. Severely compromised acinar organization was manifested by the majority of irradiated HMEC progeny as quantified by image analysis. Disrupted cell-cell communication, aberrant cell-extracellular matrix interactions, and loss of tissue-specific architecture observed in the daughters of irradiated HMEC are characteristic of neoplastic progression. These data point to a heritable, nonmutational mechanism whereby IR compromises cell polarity and multicellular organization.

Non-NASA Center↗

Demonstration of prominent actin filaments in the root columella

The distribution of actin filaments within the gravity-sensing columella cells of plant roots remains poorly understood, with studies over numerous years providing inconsistent descriptions of actin organization in these cells. This uncertainty in actin organization, and thus in actin's role in graviperception and gravisignaling, has led us to investigate actin arrangements in the columella cells of Zea mays L., Medicago truncatula Gaertn., Linum usitatissiilium L. and Nicotianla benthamiana Domin. Actin organization was examined using a combination of optimized immunofluorescence techniques, and an improved fluorochrome-conjugated phalloidin labeling method reliant on 3-maleimidobenzoyl-N-hydroxy-succinimide ester (MBS) cross-linking combined with glycerol permeabilization. Confocal microscopy of root sections labeled with anti-actin antibodies revealed patterns suggestive of actin throughout the columella region. These patterns included short and fragmented actin bundles, fluorescent rings around amyloplasts and intense fluorescence originating from the nucleus. Additionally, confocal microscopy of MBS-stabilized and Alexa Fluor-phalloidin-labeled root sections revealed a previously undetected state of actin organization in the columella. Discrete actin structures surrounded the amyloplasts and prominent actin cables radiated from the nuclear surface toward the cell periphery. Furthermore, the cortex of the columella cells contained fine actin bundles (or single filaments) that had a predominant transverse orientation. We also used confocal microscopy of plant roots expressing endoplasmic reticulum (ER)-targeted green fluorescent protein to demonstrate rapid ER movements within the columella cells, suggesting that the imaged actin network is functional. The successful identification of discrete actin structures in the root columella cells forms the perception and signaling.

Non-NASA Center↗

Crop classification with a Landsat/radar sensor combination

A combined Landsat/radar approach to classification of remotely sensed data, with emphasis on crops, was undertaken. Radar data were obtained by microwave radar spectrometers over fields near Eudora, Kansas and Landsat image data were obtained for the same test site. After Landsat digital images were registered and test-cells extracted, a comparable set of radar image pixels were simulated to match the Landsat pixels. The combined data set is then used for classification, and the results are examined with the best combination of sensor variables identified. Finally, the usefulness of radar in a simulated cloud-cover situation is demonstrated. The major conclusion derived from this study is that the combination of radar/optical sensors is superior to either one alone.

Li, R. Y.↗

Landform identification in lunar radar images

Lunar radar images have been investigated in order to understand how various radar parameters affect landform identification. The high-resolution (1-2 km cell size) 3.8-cm images of Zisk et al. (1974) were used along with the low and high resolution 70-cm mosaics of Thompson (1974 and 1987). The results indicate that radar cell size is the single most important radar parameter and that lunar features are likely to be correctly identified if they are longer than an 'identification resolution' of five times the radar cell size. The moon is considered here as an analog of Venus, since the two planets have similar mean scattering behavior.

Thompson, T. W.↗

Algorithms Could Automate Cancer Diagnosis

Five new algorithms are a complete statistical procedure for quantifying cell abnormalities from digitized images. Procedure could be basis for automated detection and diagnosis of cancer. Objective of procedure is to assign each cell an atypia status index (ASI), which quantifies level of abnormality. It is possible that ASI values will be accurate and economical enough to allow diagnoses to be made quickly and accurately by computer processing of laboratory specimens extracted from patients.

Baky, A. A.↗

Electric field effects on a near-critical fluid in microgravity

The effects of an electric field on a sample of SF6 fluid in the vicinity of the liquid-vapor critical point is studied. The isothermal increase of the density of a near-critical sample as a function of the applied electric field was measured. In agreement with theory, this electrostriction effect diverges near the critical point as the isothermal compressibility diverges. Also as expected, turning on the electric field in the presence of density gradients can induce flow within the fluid, in a way analogous to turning on gravity. These effects were observed in a microgravity environment by using the Critical Point Facility which flew onboard the Space Shuttle Columbia in July 1994 as part of the Second International Microgravity Laboratory Mission. Both visual and interferometric images of two separate sample cells were obtained by means of video downlink. The interferometric images provided quantitative information about the density distribution throughout the sample. The electric field was generated by applying 500 Volts to a fine wire passing through the critical fluid.

Zimmerli, G.↗

Spatial Pattern of Cell Damage in Tissue from Heavy Ions

A new Monte Carlo algorithm was developed that can model passage of heavy ions in a tissue, and their action on the cellular matrix for 2- or 3-dimensional cases. The build-up of secondaries such as projectile fragments, target fragments, other light fragments, and delta-rays was simulated. Cells were modeled as a cell culture monolayer in one example, where the data were taken directly from microscopy (2-d cell matrix). A simple model of tissue was given as abstract spheres with close approximation to real cell geometries (3-d cell matrix), as well as a realistic model of tissue was proposed based on microscopy images. Image segmentation was used to identify cells in an irradiated cell culture monolayer, or slices of tissue. The cells were then inserted into the model box pixel by pixel. In the case of cell monolayers (2-d), the image size may exceed the modeled box size. Such image was is moved with respect to the box in order to sample as many cells as possible. In the case of the simple tissue (3-d), the tissue box is modeled with periodic boundary conditions, which extrapolate the technique to macroscopic volumes of tissue. For real tissue, specific spatial patterns for cell apoptosis and necrosis are expected. The cell patterns were modeled based on action cross sections for apoptosis and necrosis estimated based on BNL data, and other experimental data.

Ponomarev, Artem L.↗

Cell-Detection Technique for Automated Patch Clamping

A unique and customizable machinevision and image-data-processing technique has been developed for use in automated identification of cells that are optimal for patch clamping. [Patch clamping (in which patch electrodes are pressed against cell membranes) is an electrophysiological technique widely applied for the study of ion channels, and of membrane proteins that regulate the flow of ions across the membranes. Patch clamping is used in many biological research fields such as neurobiology, pharmacology, and molecular biology.] While there exist several hardware techniques for automated patch clamping of cells, very few of those techniques incorporate machine vision for locating cells that are ideal subjects for patch clamping. In contrast, the present technique is embodied in a machine-vision algorithm that, in practical application, enables the user to identify good and bad cells for patch clamping in an image captured by a charge-coupled-device (CCD) camera attached to a microscope, within a processing time of one second. Hence, the present technique can save time, thereby increasing efficiency and reducing cost. The present technique involves the utilization of cell-feature metrics to accurately make decisions on the degree to which individual cells are "good" or "bad" candidates for patch clamping. These metrics include position coordinates (x,y) in the image plane, major-axis length, minor-axis length, area, elongation, roundness, smoothness, angle of orientation, and degree of inclusion in the field of view. The present technique does not require any special hardware beyond commercially available, off-the-shelf patch-clamping hardware: A standard patchclamping microscope system with an attached CCD camera, a personal computer with an imagedata- processing board, and some experience in utilizing imagedata- processing software are all that are needed. A cell image is first captured by the microscope CCD camera and image-data-processing board, then the image data are analyzed by software that implements the present machine-vision technique. This analysis results in the identification of cells that are "good" candidates for patch clamping (see figure). Once a "good" cell is identified, a patch clamp can be effected by an automated patchclamping apparatus or by a human operator. This technique has been shown to enable reliable identification of "good" and "bad" candidate cells for patch clamping. The ultimate goal in further development of this technique is to combine artificial-intelligence processing with instrumentation and controls in order to produce a complete "turnkey" automated patch-clamping system capable of accurately and reliably patch clamping cells with a minimum intervention by a human operator. Moreover, this technique can be adapted to virtually any cellular-analysis procedure that includes repetitive operation of microscope hardware by a human.

McDowell, Mark↗

Electroluminescence Imaging: A Study in the Impact of Microscopic Surface Defects

Electroluminescence (EL) imaging can be used as a quantitative characterization method for solar cell performance when combined with image processing, allowing for the impact of dust grain size on electroluminescence imaging characteristics to be investigated. Simulating these results via modelling can help to predict what dust grain sizes, if any, will have a greater impact on performance.

photovoltaics↗

Self-Organizing-Map Program for Analyzing Multivariate Data

SOM_VIS is a computer program for analysis and display of multidimensional sets of Earth-image data typified by the data acquired by the Multi-angle Imaging Spectro-Radiometer [MISR (a spaceborne instrument)]. In SOM_VIS, an enhanced self-organizing-map (SOM) algorithm is first used to project a multidimensional set of data into a nonuniform three-dimensional lattice structure. The lattice structure is mapped to a color space to obtain a color map for an image. The Voronoi cell-refinement algorithm is used to map the SOM lattice structure to various levels of color resolution. The final result is a false-color image in which similar colors represent similar characteristics across all its data dimensions. SOM_VIS provides a control panel for selection of a subset of suitably preprocessed MISR radiance data, and a control panel for choosing parameters to run SOM training. SOM_VIS also includes a component for displaying the false-color SOM image, a color map for the trained SOM lattice, a plot showing an original input vector in 36 dimensions of a selected pixel from the SOM image, the SOM vector that represents the input vector, and the Euclidean distance between the two vectors.

Li, P. Peggy↗

Grooved Terrain on Ganymede: A Galileo-based Synthesis

Swaths of bright "grooved terrain" (sulci) on Ganymede are 10s to 100s of kilometers wide and cross-cut the older dark terrain, forming an intricate patchwork across 2/3 of Ganymede's surface. The view of grooved terrain developed from Voyager images is that bright cells are broad graben infilled by extrusion of relatively clean (silicate-poor) liquid water, warm ice, or icy slush, and then extended and faulted. Galileo imaging has greatly improved understanding of the emplacement history and geological implications of grooved terrain, supporting a rift-like model for its formation.

Pappalardo, Robert T.↗

Design and Development of Modules to Support Live Microscopic Imaging on Ground-Based Microgravity Simulators

In space, astronauts are exposed to environmental stressors that often result in physiological changes. One prominent stressor in spaceflight is microgravity, and research has shown that long term microgravity exposure causes muscle atrophy, bone loss, cardiovascular concerns, and vision impairment. It is critical to understand how altered gravity affects physiology on the cellular, molecular, and gene level in order to accurately assess health risks and to develop effective countermeasures. Ground-based microgravity simulators such as random positioning machines (RPMs) are used to produce some of the biological effects of altered gravity on different cell types and organisms. Real-time imaging during simulations are of particular interest as we can study how basic cell functions such as cell division, cell migration, and proliferation progress under microgravity conditions. However, design limitations of present microgravity simulators such as susceptibility to parasitic vibration and displacement of the sample from the center of rotation challenge the accuracy of experiment results and live images. We have developed a cell culture sample holder module suitable for live microscopic imaging on an RPM. CAD modeling and 3D printing technology were used to implement modifications to the sample holder and to install a digital microscope to perform live bright-field and fluorescent imaging. Vibration damping materials were also investigated to allow for stable imaging while the microgravity simulator was within a cell culture incubator. Novel methods and hardware modifications for improving live cell imaging on ground-based microgravity simulators were proposed and discussed.

3D printing↗

Camera, handlens, and microscope optical system for imaging and coupled optical spectroscopy

An optical system comprising two lens cells, each lens cell comprising multiple lens elements, to provide imaging over a very wide image distance and within a wide range of magnification by changing the distance between the two lens cells. An embodiment also provides scannable laser spectroscopic measurements within the field-of-view of the instrument.

Mungas, Greg S.↗

Camera, handlens, and microscope optical system for imaging and coupled optical spectroscopy

An optical system comprising two lens cells, each lens cell comprising multiple lens elements, to provide imaging over a very wide image distance and within a wide range of magnification by changing the distance between the two lens cells. An embodiment also provides scannable laser spectroscopic measurements within the field-of-view of the instrument.

Mungas, Greg S.↗

Distribution and Spectroscopy of Green Fluorescent Protein and Acyl-CoA: Cholesterol Acytransferase in Sf21 Insect Cells

Acyl-CoA: cholesterol acyltransferase (ACAT) is thought to significantly participate in the pathway of cholesterol esterification that underlies the pathology of artherosclerosis. This enzyme is a membrane protein known to be preferentially bound within the endoplasmic reticulum of mammalian cells, from which location it esterifies cholesterol derived from low density lipoprotein. Cultures of insect cells were separately infected with baculovirus containing the gene for green fluroescent protein (GFP) and with baculovirus containing tandem genes for GFP and ACAT. These infected cultures expressed GFP and the fusion protein GCAT, respectively, with maximum expression occurring on the fourth day after infection. Extraction of GFP- and of GCAT-expressing cells with urea and detergent resulted in recovery of fluorescent protein in aqueous solution. Fluorescence spectra at neutral pH were identical for both GFP and GCAT extracts in aqueous solution, indicating unperturbed tertiary structure for the GFP moiety within GCAT. In a cholesterol esterification assay, GCAT demonstrated ACAT activity, but with less efficiency compared to native ACAT. It was hypothesized that the membrane protein ACAT would lead to differences in localization of GCAT compared to GFP within the respective expressing insect cells. The GFP marker directly and also within the fusion protein GCAT was accordingly used as the intracellular probe that was fluorescently analyzed by the new biophotonics technique of hyperspectral imaging. In that technique, fluorescence imaging was obtained from two dimensional arrays of cells, and regions of interest from within those images were then retrospectively analyzed for the emission spectra that comprises the image. Results of hyperspectral imaging of insect cells on day 4 postinfection showed that GCAT was preferentially localized to the cytoplasm of these cells compared to GFP. Furthermore, the emission spectra obtained for the localized GCAT displayed a peak blue shift from 518nm obtained in neutral aqueous solution to 505nm obtained in localized regions within the cells. This blue shift indicates change in the fluorescence coupling of the GFP moiety of GCAT. It is hypothesized that change in tertiary environment of GCAT, coincident with intracellular deposition of GCAT, follows from intracellular trafficking of GCAT leading to membrane interactions with the ACAT moiety, and/or self-assembly of GCAT, that alters the chromophore environment of the GFP moiety of GCAT. These findings introduce a new technique of biophotonic imaging to studies of intracellular protein trafficking and interactions. This technique of hyperspectral imaging could contribute to advancing the emergent field of proteomics. Because of the noninvasive nature of this technique, kinetic processes associated with intracellular protein trafficking, and interactions of proteins within cellular domains, can be considered for investigation within a single cell as well as a cell population.

Richmond, R. C.↗

The Analysis of the Patterns of Radiation-Induced DNA Damage Foci by a Stochastic Monte Carlo Model of DNA Double Strand Breaks Induction by Heavy Ions and Image Segmentation Software

To create a generalized mechanistic model of DNA damage in human cells that will generate analytical and image data corresponding to experimentally observed DNA damage foci and will help to improve the experimental foci yields by simulating spatial foci patterns and resolving problems with quantitative image analysis. Material and Methods: The analysis of patterns of RIFs (radiation-induced foci) produced by low- and high-LET (linear energy transfer) radiation was conducted by using a Monte Carlo model that combines the heavy ion track structure with characteristics of the human genome on the level of chromosomes. The foci patterns were also simulated in the maximum projection plane for flat nuclei. Some data analysis was done with the help of image segmentation software that identifies individual classes of RIFs and colocolized RIFs, which is of importance to some experimental assays that assign DNA damage a dual phosphorescent signal. Results: The model predicts the spatial and genomic distributions of DNA DSBs (double strand breaks) and associated RIFs in a human cell nucleus for a particular dose of either low- or high-LET radiation. We used the model to do analyses for different irradiation scenarios. In the beam-parallel-to-the-disk-of-a-flattened-nucleus scenario we found that the foci appeared to be merged due to their high density, while, in the perpendicular-beam scenario, the foci appeared as one bright spot per hit. The statistics and spatial distribution of regions of densely arranged foci, termed DNA foci chains, were predicted numerically using this model. Another analysis was done to evaluate the number of ion hits per nucleus, which were visible from streaks of closely located foci. In another analysis, our image segmentaiton software determined foci yields directly from images with single-class or colocolized foci. Conclusions: We showed that DSB clustering needs to be taken into account to determine the true DNA damage foci yield, which helps to determine the DSB yield. Using the model analysis, a researcher can refine the DSB yield per nucleus per particle. We showed that purely geometric artifacts, present in the experimental images, can be analytically resolved with the model, and that the quantization of track hits and DSB yields can be provided to the experimentalists who use enumeration of radiation-induced foci in immunofluorescence experiments using proteins that detect DNA damage. An automated image segmentaiton software can prove useful in a faster and more precise object counting for colocolized foci images.

Ponomarev, Artem↗

Spaceflight Holography Investigation in a Virtual Apparatus (SHIVA) Ground Experiments and Concepts for Flight Design

This paper discusses the development and design of an experimental test cell for ground-based testing to provide requirements for the Spaceflight Holography Investigation in a Virtual Apparatus (SHIVA) experiment. Ground-based testing of a hardware breadboard set-up is being conducted at Marshall Space Flight Center in Huntsville, Alabama. SHIVA objectives are to test and validate new solutions of the general equation of motion of a particle in a fluid, including particle-particle interaction, wall effects, motion at higher Reynolds Number, and a motion and dissolution of a crystal moving in a fluid. These objectives will be achieved by recording a large number of holograms of particle motion in the International Space Station (ISS) glove box under controlled conditions, extracting the precise three- dimensional position of all the particles as a function of time, and examining the effects of all parameters on the motion of the particles. This paper will describe the mechanistic approach to enabling the SHIVA experiment to be performed in a ISS glove box in microgravity. Because the particles are very small, surface tension becomes a major consideration in designing the mechanical method to meet the experiments objectives in microgravity, To keep a particle or particles in the center of the test cell long enough to perform and record the experiment and to preclude contribution to particle motion, requires avoiding any initial velocity in particle placement. A Particle Injection Mechanism (PIM) designed for microgravity has been devised and tested to enable SHIVA imaging. Also, a test cell capture mechanism, to secure the test cell during vibration on a specially designed shaker table for the SHIVA experiment will be described. Concepts for flight design are also presented.

Miernik, Janie H.↗