Search NASA⌕ Search

SEARCH · Search NASA

Results for “centrifugal”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Centrifugal Pump Model for System Codes for Advanced NPP Designs

In this document, a homologous model and one-dimensional line model for centrifugal pump are described to provide the theoretical background of a pump model to be developed in system-level codes. Input and output parameters are proposed, along with a summary of the governing equations for each model. Furthermore, hydraulic performance degradation of centrifugal pump is also modeled in the homologous pump model. This document suggests that system codes provide a homologous and one-dimensional line model for centrifugal pumps, allowing the users to choose the model that best fits their purposes.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Enhancing Molecular Isotope Detection with a Chirp Tuned Optical Centrifuge

This paper gives a brief experimental overview on creating a chirp-tunable optical centrifuge with the goal of amplifying the isotope shift of a given molecule. Results for this experiment were recorded with a CO 2 plume as the probed material. Beyond amplification of the isotope shift, this technology could be modified to alter magnetic field characteristics of common molecules as well as simulating high temperature gases found in combustion environments. Our specific design uses double mirror and grating stretcher and will include a unique tuning feature for customization of the beam’s red and blue components' temporal chirp, allowing for quick reactivity to varying task requirements. The design and parameters will be discussed, as well as the methods used to model the optical centrifuge. Although this experiment is ongoing, results have been gathered previously that display the efficacy of the optical centrifuge. For the probed CO 2 sample, Raman Shifts centered around a wavenumber of 60 and 275 were recorded with durations of 1000 and 800 picoseconds, respectively.

47 OTHER INSTRUMENTATION↗

MoS 2 -Decorated Graphene@porous Carbon Nanofiber Anodes via Centrifugal Spinning

Sodium-ion batteries (SIBs) are promising alternatives to lithium-ion batteries as green energy storage devices because of their similar working principles and the abundance of low-cost sodium resources. Nanostructured carbon materials are attracting great interest as high-performance anodes for SIBs. Herein, a simple and fast technique to prepare carbon nanofibers (CNFs) is presented, and the effects of carbonization conditions on the morphology and electrochemical properties of CNF anodes in Li- and Na-ion batteries are investigated. Porous CNFs containing graphene were fabricated via centrifugal spinning, and MoS 2 were decorated on graphene-included porous CNFs via hydrothermal synthesis. The effect of MoS 2 on the morphology and the electrode performance was examined in detail. The results showed that the combination of centrifugal spinning, hydrothermal synthesis, and heat treatment is an efficient way to fabricate high-performance electrodes for rechargeable batteries. Furthermore, CNFs fabricated at a carbonization temperature of 800 °C delivered the highest capacity, and the addition of MoS 2 improved the reversible capacity up to 860 mAh/g and 455 mAh/g for Li- and Na-ion batteries, respectively. A specific capacity of over 380 mAh/g was observed even at a high current density of 1 A/g. Centrifugal spinning and hydrothermal synthesis allowed for the fabrication of high-performance electrodes for sodium ion batteries.

25 ENERGY STORAGE↗

Effects of bedrest and centrifugation of humans on serum thyroid function tests.

Changes in plasma volume and protein concentration have been reported when normal subjects are bedrested or centrifuged. Since thyroid hormones are transported by specific plasma proteins, each of these procedures could be expected to change plasma levels of these hormones. In this study centrifugation of normal healthy human subjects produced an increased concentration of total protein and albumin. When these same subjects were bedrested for six days, no change in total protein, albumin or thyroxine binding globulin were found although there was an eight per cent decrease in plasma volume. Centrifugation and, to a lesser extent, bedrest produced changes in serum T-4 levels and the T-3 test results. The direction of these changes (decreased % T-3 values and increased T-4 levels) indicate that these two situations produce an increased plasma concentration of thyroxine binding sites.

Leach, C. S.↗

Erosion in radial inflow turbines. Volume 2: Balance of centrifugal and radial drag forces on erosive particles

The particle motion in two-dimensional free and forced inward flowing vortices is considered. A particle in such a flow field experiences a balance between the aerodynamic drag forces that tend to drive erosive particles toward the axis, and centrifugal forces that prevent these particles from traveling toward the axis. Results predict that certain sizes of particles will achieve a stable orbit about the turbine axis in the inward flowing free vortex. In this condition, the radial drag force is equal to the centrifugal force. The sizes of particles that will achieve a stable orbit is shown to be related to the gas flow velocity diagram at a particular radius. A second analysis yields a description of particle sizes that will experience a centrifugal force that is greater than the radial component of the aerodynamic drag force for a more general type of particle motion.

Clevenger, W. B., Jr.↗

Morphology of Arabidopsis grown under chronic centrifugation and on the clinostat

Morphological measurements were made on populations of Arabidopsis thaliana grown from seed for 21 days under essentially constant environmental conditions except for the influence of gravitational or centrifugal accelerations. Growth conditions were what had been proposed for experiments in an artificial satellite. Observations are reported for plants grown at normal 1-g upright or on horizontal clinostats and for plants grown on a centrifuge. Increased g-force, up to 15 times normal, was found to have significant but small effects on some morphological end points. The plants' sensitivity to the magnitude of the g-force was much less than to its vector direction. Data from centrifuge experiments were extrapolated to zero-g to predict a set of morphological characteristics of a plant developing in the satellite environment. As an alternative means of predicting properties of a zero-g plant, characteristics of plants grown on horizontal clinostats were measured. The results of these two predictive methods were not in agreement. Clinostat grown plants were morphologically distinct from upright stationary controls.

Brown, A. H.↗

Microvascular pressure responses of second-generation rats chronically exposed to 2 g centrifugation

Preliminary results are presented for a study aimed at a quantitative comparison of microvascular dynamics in second-generation rats reared in a 2-g force field produced by centrifugation with similar data from animals reared in a centrifuge that produced only a 1-g force. It is shown that the pressure distribution in the mesenteric microvasculature of the second generation of rats reared in a 2-g environment, as well as the animals' blood pressure response to epinephrine, are significantly different compared to their 1-g counterparts. In particular, 1-g and 2-g chronic centrifugation enhances the arterial blood pressure, and the 2-g force field attenuates the pressor effects of norepinephrine.

Richardson, D. R.↗

Femoral development in chronically centrifuged rats

Groups of 30-d-old male and female rats were centrifuged at 2.00 G (RE, Rotation Experimental), 1.05 G (RC, Rotation Control) or exposed to the noise and wind of the centrifuge at 1.00 G (EC, Earth Control) for periods of 1, 2, 4, 8, and 16 weeks. Measurements of their femurs indicated that exposure to centrifugation a) decreased femoral length in RE animals, b) increased femoral length in RC animals, c) reduced femoral diameter in RE and RC animals, d) increased L/D ratios in RC animals, e) decreased L/D ratios in RE animals, f) increased femur length/body weight in RE animals, g) decreased cortical thickness (CT) in RE animals, h) increased relative CT in RE animals, and decreased it in RC animals, i) accelerated ossification in RC femoral heads, j) thinned and distorted RE epiphyseal plates, and k) thickened condylar cartilage in RE females. The effects tended to be strongly sexually dimorphic, with females more severely affected by the stress than males.

Smith, S. D.↗

Laminar flow effects in the coil planet centrifuge

The coil planet centrifuge designed by Ito employs flow of a single liquid phase, through a rotating coiled tube in a centrifugal force field, to provide a separation of particles based on sedimentation rates. Mathematical solutions are derived for the linear differential equations governing particle behavior in the coil planet centrifuge device. These solutions are then applied as the basis of a model for optimizing particle separations.

Herrmann, F. T.↗

Effects of chronic centrifugation on mice

Previous studies have shown that exposure to excess gravity in vitro alters the developmental sequence in embryonic mouse limbs and palates (Duke, Janer and Campbell, 1984; Duke, 1983). The effects of excess gravity on in vivo mammalian development was investigated using a small animal centrifuge. Four-week old female mice exposed to excess gravities of 1.8-3.5 G for eight weeks weighed significantly less than controls. Mice were mated after five weeks of adaptation to excess G, and sacrificed either at gestational day 12 or 18. There were fewer pregnancies in the centrifuged group (4/36) than in controls (9/31), and crown rump lengths (CRL) of embryos developing in the centrifuge were less than CRLs of 1-G embryos. These results show that although immersed in amniotic fluid, embryos are responsive to Delta-G.

Janer, L.↗

The influence of centrifugal forces on the B field structure of an axially symmetric equilibrium magnetosphere

A model is presented of an axially symmetric pole-on magnetosphere in MHD force balance, in which both plasma thermal pressure gradients and centrifugal force are taken into account. Assuming that planetary rotation leads to differentially rotating magnetotail field lines, the deformation of magnetotail field lines under the influence of both thermal plasma pressure and centrifugal forces was calculated. Analytic solutions to the Grad-Shafranov equation are presented, which include the centrifugal force term. It is shown that the nonrotational magnetosphere with hot thermal plasma leads to a field configuration without a toroidal B(phi) component and without field-aligned Birkeland currents. The other extreme, a rapidly rotating magnetosphere with cold plasma, leads to a configuration in which plasma must be confined within a thin disk in a plane where the radial magnetic field component B(r) vanishes locally.

Ye, Gang↗

NASA low-speed centrifugal compressor for 3-D viscous code assessment and fundamental flow physics research

A low speed centrifugal compressor facility recently built by the NASA Lewis Research Center is described. The purpose of this facility is to obtain detailed flow field measurements for computational fluid dynamic code assessment and flow physics modeling in support of Army and NASA efforts to advance small gas turbine engine technology. The facility is heavily instrumented with pressure and temperature probes, both in the stationary and rotating frames of reference, and has provisions for flow visualization and laser velocimetry. The facility will accommodate rotational speeds to 2400 rpm and is rated at pressures to 1.25 atm. The initial compressor stage being tested is geometrically and dynamically representative of modern high-performance centrifugal compressor stages with the exception of Mach number levels. Preliminary experimental investigations of inlet and exit flow uniformly and measurement repeatability are presented. These results demonstrate the high quality of the data which may be expected from this facility. The significance of synergism between computational fluid dynamic analysis and experimentation throughout the development of the low speed centrifugal compressor facility is demonstrated.

Hathaway, M. D.↗

Centrifugal intensity and duration as countermeasures to soleus muscle atrophy

The effects of artificially induced gravity on the atrophy process of slow-twitch soleus muscle are studied in order to determine whether centrifugation could be an effective countermeasure to nonweight bearing at 1 G. It is observed that the soleus muscle atrophied 32 percent during seven days of nonweight bearing without countermeasures, and centrifugation treatment did not completely prevent atrophy relative to precontrol wet weight of the soleus muscle. Nonweight-bearing groups receiving treatments of 1, 1.5, or 2.6 G had 48, 56, and 65 percent, respectively, of the atrophy observed in a nonweight-bearing-only group compared with the precontrol group. It is concluded that, as a countermeasure to nonweight-bearing-induced atrophy of the soleus muscle, centrifugation at 2.6 G is no more effective than exposure to 1 or 1.5 G.

D'Aunno, Dominick S.↗

Space Station Centrifuge: A Requirement for Life Science Research

A centrifuge with the largest diameter that can be accommodated on Space Station Freedom is required to conduct life science research in the microgravity environment of space. (This was one of the findings of a group of life scientists convened at the University of California, Davis, by Ames Research Center.) The centrifuge will be used as a research tool to understand how gravity affects biological processes; to provide an on-orbit one-g control; and to assess the efficacy of using artificial gravity to counteract the deleterious biological effect of space flight. The rationale for the recommendation and examples of using ground-based centrifugation for animal and plant acceleration studies are presented. Included are four appendixes and an extensive bibliography of hypergravity studies.

Smith, Arthur H.↗

NASA low-speed centrifugal compressor for 3-D viscous code assessment and fundamental flow physics research

A low speed centrifugal compressor facility recently built by the NASA Lewis Research Center is described. The purpose of this facility is to obtain detailed flow field measurements for computational fluid dynamic code assessment and flow physics modeling in support of Army and NASA efforts to advance small gas turbine engine technology. The facility is heavily instrumented with pressure and temperature probes, both in the stationary and rotating frames of reference, and has provisions for flow visualization and laser velocimetry. The facility will accommodate rotational speeds to 2400 rpm and is rated at pressures to 1.25 atm. The initial compressor stage being tested is geometrically and dynamically representative of modern high-performance centrifugal compressor stages with the exception of Mach number levels. Preliminary experimental investigations of inlet and exit flow uniformly and measurement repeatability are presented. These results demonstrate the high quality of the data which may be expected from this facility. The significance of synergism between computational fluid dynamic analysis and experimentation throughout the development of the low speed centrifugal compressor facility is demonstrated.

Hathaway, M. D.↗

Dynamics and stability of a tethered centrifuge in low earth orbit

The three-dimensional attitude dynamics of a spaceborne tethered centrifuge for artificial gravity experiments in low earth orbit is analyzed using two different methods. First, the tethered centrifuge is modeled as a dumbbell with a straight viscoelastic tether, point tip-masses, and sophisticated environmental models such as nonspherical gravity, thermal perturbations, and a dynamic atmospheric model. The motion of the centrifuge during spin-up, de-spin, and steady-rotation is then simulated. Second, a continuum model of the tether is developed for analyzing the stability of lateral tether oscillations. Results indicate that the maximum fluctuation about the 1-g radial acceleration level is less than 0.001 g; the time required for spin-up and de-spin is less than one orbit; and lateral oscillations are stable for any practical values of the system parameters.

Quadrelli, B. M.↗

Research opportunities with the Centrifuge Facility

The Centrifuge Facility on Space Station Freedom will consist of a 2.5-meter diameter Centrifuge accommodating two concentric rings of habitats and providing variable g-forces between 0.01 g and 2.0 g; modular habitats providing housing and lifesupport for rats, mice, and plants; a habitat holding system providing power, water, airflow and other utilities to several modular habitats; and a life sciences glovebox, an isolated work volume accommodating simultaneous operations by at least two scientists and providing lighting, airflow, video and data access, and other experiment support functions. The centrifuge facility will enable long-duration animal and plant microgravity research not previously possible in the NASA flight research program. It will offer unprecedented opportunities for use of on-board 1-g control populations and statistically significant numbers of specimens. On orbit 1-g controls will allow separation of the effects of microgravity from other environmental factors. Its selectable-g and simultaneous multiple-g capabilities will enable studies of gravitational thresholds, the use of artificial gravity as a countermeasure to the effects of microgravity, and ready simulation of Lunar and Martian gravities.

Funk, Glenn A.↗

Numerical modeling of crystal growth on a centrifuge for unstable natural convection configurations

The fluid mechanics associated with crystal growth processes on centrifuges is modeled using 2D and 3D models. Two-dimensional calculations show that flow bifurcations exist in such crystal growth configurations where the ampoule is oriented in the same direction as the resultant gravity vector and a temperature gradient is imposed on the melt. A scaling analysis is formulated to predict the flow transition point from the natural convection dominated regime to the Coriolis force dominated regime. Results of 3D calculations are presented for two thermal configurations of the crystal growth cell: top heated and bottom heated with respect to the centrifugal acceleration. In the top heated configuration, a substantial reduction in the convection intensity within the melt can be attained by centrifuge operations, and close to steady diffusion-limited thermal conditions can be achieved over a narrow range of the imposed microgravity level. In the bottom heated configuration the Coriolis force has a stabilizing effect on fluid motion by delaying the onset of unsteady convection.

Ramachandran, N.↗