Search NASA⌕ Search

SEARCH · Search NASA

Results for “centrifuge method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

90 records · Page 5

SRPPF Aqueous Recovery System Sorbent Testing

This study details preliminary testing of 7 inorganic sorbents for the solidification of the surrogate SRPPF aqueous recovery system liquid excess material of 4M sodium nitrate. Sorbents were subject to various mixing methods to incorporate sodium nitrate solution including static, rotating, and in situ paddle mixing. Paddle mixing was found to be the most effective mixing technique, while simple static tests were also successful, though only for some of the sorbents. Setting tests were performed to ensure that the sorbent sequestered the liquid without release through a conical paint filter. Recommended set times ranged from near immediate to 7 days. The set mixtures were investigated further using ultra-centrifugal liquid release testing, thermogravimetric analysis, and visual microscopy to understand the mechanism by which the sorbent sequestered the liquid. Most sorbents seem to incorporate liquid by sorbing it onto and into the sorbent particles, while Drierite ® , anhydrous calcium sulfate, created a crystal structure that bound the surrogate liquid. Overall, four sorbents are recommended for continued testing: Aquaset II, Aquaset IIG, Drierite ® , and Spill-X-A.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SARS-CoV-2 raw wastewater surveillance from student residences on an urban university campus

The COVID-19 pandemic brought about an urgent need to monitor the community prevalence of infection and detect the presence of SARS-CoV-2. Testing individual people is the most reliable method to measure the spread of the virus in any given community, but it is also the most expensive and time-consuming. Wastewater-based epidemiology (WBE) has been used since the 1960s when scientists implemented monitoring to measure the effectiveness of the Polio vaccine. Since then, WBE has been used to monitor populations for various pathogens, drugs, and pollutants. In August 2020, the University of Tennessee-Knoxville implemented a SARS-CoV-2 surveillance program that began with raw wastewater surveillance of the student residence buildings on campus, the results of which were shared with another lab group on campus that oversaw the pooled saliva testing of students. Sample collection began at 8 am, and the final RT-qPCR results were obtained by midnight. The previous day’s results were presented to the campus administrators and the Student Health Center at 8 am the following morning. The buildings surveyed included all campus dormitories, fraternities, and sororities, 46 buildings in all representing an on-campus community of over 8,000 students. The WBE surveillance relied upon early morning “grab” samples and 24-h composite sampling. Because we only had three Hach AS950 Portable Peristaltic Sampler units, we reserved 24-h composite sampling for the dormitories with the highest population of students. Samples were pasteurized, and heavy sediment was centrifuged and filtered out, followed by a virus concentration step before RNA extraction. Each sample was tested by RT-qPCR for the presence of SARS-CoV-2, using the CDC primers for N Capsid targets N1 and N3. The subsequent pooled saliva tests from sections of each building allowed lower costs and minimized the total number of individual verification tests that needed to be analyzed by the Student Health Center. Our WBE results matched the trend of the on-campus cases reported by the student health center. The highest concentration of genomic copies detected in one sample was 5.06 × 10 7 copies/L. Raw wastewater-based epidemiology is an efficient, economical, fast, and non-invasive method to monitor a large community for a single pathogen or multiple pathogen targets.

60 APPLIED LIFE SCIENCES↗

Trace Chemical Detection Using Intercalated MXenes as a Signal Enhancing Substrate in Optical Probes

MXenes are 2D materials composed of layered transition metal nitrides or carbides. These materials are synthesized by HF exfoliation from MAX phases (Ti{sub 3}AlC{sub 2}). The 2D nanomaterial was synthesized by the removal of the 'A' element, resulting in a Mxene product (Ti{sub 3}C{sub 2}). MXenes have the general formula M{sub n+1}X{sub n}T{sub x}, where M is an early transition metal, X is Carbon and/or Nitrogen, and T accounts for surface terminated functional groups such as Fluoride, hydroxyl, and oxygen. These materials have very unique properties, similar to graphene, that allows them to be applied in a variety of trace detection techniques including surface-enhanced Raman spectroscopy (SERS). MXenes have also been demonstrated to selectively uptake uranyl ion, UO{sub 2}{sup 2+}. If this property can be combined with SERS or fluorescence detection, it may be possible to use MXenes as the basis for an alternative method to kinetic phosphorescence analysis (KPA) for trace uranyl measurements. Objectives: To confirm that MXene Nano materials are suitable substrates for SERS and sensor development by enhancing Raman signaling. To determine if certain MXene preparation methods yield materials that are more suitable for trace sensing methods. To determine uranyl uptake properties of these MXene materials and test them for analytical signals. Sample Preparation: Preparation of Ti{sub 3}C{sub 2}MXene (at FSU). MXenes were prepared by etching Al from Ti{sub 3}AlC{sub 2} (MAX phase)material. Two etching techniques yield different MXene products: LiF/HCl: Milder reaction, larger MXene flakes. HF: Harsher reaction, smaller flakes, larger layer separation. Products washed to remove etchant, vacuum filtered, and dried. Dried MXene flakes are air-stable. Film preparation for sensor testing (at SRNL): Suspend powder in diH{sub 2}O, purge with Ar, sonicate for 30 min. Centrifuge and collect supernate with suspended particles. Observed LiF-etched Mxene yielded a higher density of particles and darker collected solution. Drop-cast (4 ml) supernate onto slides and dried with Ar. For Rhodamine B (RhB) testing, drop-cast 4 ml drops onto Mxene spots and dried with Ar. Scanning Electron Microscopy conditions: 10 kV Beam energy, high vacuum; Working distance of 8 mm; beam penetration depth appx. 4 microns, beam spot size appx. 2 nanometers. Results: Detection of aluminum correlates with bright spots on image. Presence of aluminum shows that LiF/HCl etching was less thorough than HF etching. Trace Cl detection in LiF images suggests incomplete rinsing. HF has smaller feature size, more layer structure, and increased homogeneity, consistent with expectations. Macroscopic Raman spectroscopy measurements: 532 nm excitation, ∼50 mW with a ∼100 micron spot size (InPhotonics RPB probe). Kaiser Optical Holospec f/1.8 spectrometer with cooled (-60 deg.C) Andor iDus OE420 CCD. LiF 1x supernate showed good signal for trace measurements of Rhodamine B. HF and 1/4x LiF supernates showed little Mxene or Rhodamine B signal. Low deposition densities led to excess background signal from glass slides. For LiF film, response is linear with Rhodamine B concentration over range tested. Will retest with Raman microscope (∼1 micron spot size) to characterize SERS of more dilute LiF and HF etched Mxenes. Conclusions: The LiF etched material was more suitable for macroscopic SERS measurements because it was more concentrated, resulting in a thicker film than the HF etched Mxene and diluted LiF sample. However, the other materials may give greater SERS enhancements, which we hope to determine from measurements with the Raman microscope. From characterization with SEM we concluded that the HF etched Mxene is more uniform/homogenous and has smaller particle size than the LiF etched Mxene. There is still aluminum present in both samples indicating that etching wasn't complete, but the removal of the aluminum was more efficient in the HF method. Path Forward: Observe SERS with Raman microscopy, to obtain better signals for the more diluted samples and be able to compare enhancement effects for the different MXenes. Characterize uranyl sorption into MXene films and test Raman and fluorescence signals. Revisit the etching conditions to improve removal of aluminum. FSU and SRNL will continue to collaborate to create and characterize different Mxene materials and test their usefulness for sensor applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Measuring very low radiation doses in PTFE for nuclear forensic enrichment reconstruction

Every country that has made nuclear weapons has used uranium enrichment to do so. Despite the centrality of this technology to international security, there is still no reliable physical marker of past enrichment in the open literature that can be used to perform forensic verification of historically produced weapons on gas centrifuges. We show that the extremely low radioactivity from uranium alpha emissions during enrichment leaves detectable and irreversible calorimetric signatures in the common enrichment gasket material PTFE, allowing for historical reconstruction of past enrichment activities at a sensitivity better than one weapon’s quantity of highly enriched uranium. Fast scanning calorimetry also enables the measurement of recrystallization enthalpies of sequentially microtomed slices, confirming the magnitude and the type of radiation exposure while also providing detection of tampering and a method for analyzing field samples useful for treaty verification. Furthermore, this work opens the door for common items to be turned into precise dosimeters to detect the past presence of radioactivity, nuclear materials, and related activities with high confidence.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Multiple-charging effects on the CCN activity and hygroscopicity of surrogate black carbon particles

Accurate measurements of cloud condensation nuclei (CCN) activity and hygroscopicity of black carbon (BC)-containing particles are particularly important because of the positive climate forcing from these particles. Such measurements are typically conducted on particles selected by a Differential Mobility Analyzer (DMA), which in addition to singly charged particles transmits multiply charged larger particles that have the same electrical mobility. These larger particles activate at lower supersaturations than the singly charged particles, biasing measurements and resulting in overestimation of CCN activity and hygroscopicity parameter (κ). Here, we measure the CCN activity and determine κ for different BC surrogates with electrical mobility diameters from 100 to 200 nm selected 1) only by electrical mobility with a DMA, and 2) by both electrical mobility and mass using a DMA and a Centrifugal Particle Mass Analyzer (CPMA), thus allowing selection of only singly charged particles. We demonstrate the use of the DMA-CPMA system in resolving biases caused by multiply charged particles, and we show that the effect of multiple charging on the CCN activity of the BC particles is strongly influenced by morphology dispersion, i.e., the variability due to the range of morphologies of particles that have the same electrical mobility and mass. Finally, our findings show that electrical mobility-based methods alone are unlikely to lead to accurate results in measurements of CCN activation and hygroscopicity of BC particles, even for those with a more compact morphology.

54 ENVIRONMENTAL SCIENCES↗

Structures in the heavy-ion fusion excitation function at and above the Coulomb barrier

Contrary to descriptions from coupled-channels or other model calculations, heavy-ion fusion excitation functions are not smooth near and above the Coulomb barrier. There appear to be weak but noticeable oscillations or structures within the excitation functions that can be observed clearly in representation $d (σ E)/d E$ and in the comparison with theoretical calculations $σ (E) – σ_{th}(E)$. Importantly, a rather similar phenomenon has been studied before and can be explained in light symmetric systems as the influence of the centrifugal barrier penetration only on even angular momentum, but it cannot be extended to heavier, more asymmetric fusion systems. A more thorough investigation may be required to investigate this newly indicated behavior.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Characterization and Scaling of Forced Convective Swirl in Sinusoidal Wavy-Plate-Fin Cores of Compact Heat Exchangers

The characterization and scaling of the thermal-hydraulic performance in wavy plate-fin compact heat exchanger cores, based on the understanding of the physical phenomena and heat transfer enhancement mechanism is delineated. Experimental data are presented for forced convection in air (Pr = 0.71) with flow rates in the range 50 ≤ Re ≤ 4000. A variety of wavy-fin cores that span viable applications, with geometrical attributes described by the cross section aspect ratio α (ratio of fin spacing to height), fin corrugation aspect ratio γ (ratio of 2× corrugation amplitude to wave pitch), and fin spacing ratio ζ (ratio of fin spacing to wave pitch), are considered. To characterize and correlate the vortex-flow mixing in interfin spaces, a Swirl number Sw is introduced from the balance of viscous, inertial and centrifugal forces. It is shown that the laminar, transitional and turbulent flow regimes can be explicitly identified by this Swirl number. Based on the experimental results and extended analysis, new correlations for Fanning friction factor f and Colburn factor j are developed with Sw, α, γ, and ζ as scaling parameters. Requisite expressions are devised by a superposition of both enhancement components due to the corrugated surface area enlargement and induced swirl flow field, and they are combined to cover the laminar, transitional and turbulent regimes by the method of asymptotic matching. The resulting generalized correlations are further shown to predict all available experimental data for f and j factors to within ±20% and ±15%, respectively.

42 ENGINEERING↗

Study of a High-speed Outer Rotor Burst Containing Enclosure

The increasing demand for high-speed electric machines in many applications pushes the development of high-power density electric motors. Outer rotor motors, which can be designed with a larger airgap diameter than inner rotor motors for the same overall diameter and, therefore, provide higher torque, distinguish themselves in space-constrained but high torque applications. However, increasing the motor speed and diameter results in significant centrifugal loads for the outer rotor motor due to its higher airgap diameter. Additional attention must be paid at the design stage to consider the extreme situation of possible mechanical failure, such as the sudden burst of the high-speed rotating parts in the motor, and measures must be taken to prevent their damage to other system components in advance. Through the finite element dynamic impact analysis, we studied the damage caused by broken parts on the inner wall of the electric motor housing when the motor rotates at 20,000 RPM. The proposed method is expected to provide reasonable recommendations of the enclosure material and its thickness required to protect other components in the same powertrain system when the high-power density motor fails unexpectedly.

Lin, Lianshan↗

A New Approach to Monitoring Solvent Extraction Processes for the Nuclear Industry

As part of an initiative to steward research, development, and innovation into the nuclear fuel cycle, Idaho National Laboratory is building the Beartooth testbed. Beartooth will include a cascade of centrifugal contactors, glove box lines, solidification, and dissolution equipment to aid in the progression of novel separation techniques and provide hands-on opportunities to early-career separation scientists. Beartooth will incorporate novel monitoring techniques using sensors and machine learning algorithms to inform a process operator of separation conditions. This research is examining monitoring technologies not typically used in nuclear separation processes such as acoustic microphones, accelerometers, infrared cameras, red-green-blue color sensors, among others. These sensors are being examined for their functionality within a separation process and their ability to detect applicable signals. Machine learning methods are being developed to determine their utility in detecting faults and alerting operators of expected and unexpected events. These methods have the potential to impact Safeguards by Design efforts and real-time decision making. This overview will detail preliminary results from acoustic, vibration, and color sensors.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Separation of Lipoproteins for Quantitative Analysis of 14 C-Labeled Lipid-Soluble Compounds by Accelerator Mass Spectrometry

To date, 14 C tracer studies using accelerator mass spectrometry (AMS) have not yet resolved lipid-soluble analytes into individual lipoprotein density subclasses. The objective of this work was to develop a reliable method for lipoprotein separation and quantitative recovery for biokinetic modeling purposes. The novel method developed provides the means for use of small volumes (10–200 µL) of frozen plasma as a starting material for continuous isopycnic lipoprotein separation within a carbon- and pH-stable analyte matrix, which, following post-separation fraction clean up, created samples suitable for highly accurate 14 C/ 12 C isotope ratio determinations by AMS. Manual aspiration achieved 99.2 ± 0.41% recovery of [5- 14 CH 3 ]-(2R, 4'R, 8'R)-α-tocopherol contained within 25 µL plasma recovered in triacylglycerol rich lipoproteins (TRL = Chylomicrons + VLDL), LDL, HDL, and infranatant (INF) from each of 10 different sampling times for one male and one female subject, n = 20 total samples. Small sample volumes of previously frozen plasma and high analyte recoveries make this an attractive method for AMS studies using newer, smaller footprint AMS equipment to develop genuine tracer analyses of lipophilic nutrients or compounds in all human age ranges.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Blood Plasma Self-Separation Technologies during the Self-Driven Flow in Microfluidic Platforms

Blood plasma is the most commonly used biofluid in disease diagnostic and biomedical analysis due to it contains various biomarkers. The majority of the blood plasma separation is still handled with centrifugation, which is off-chip and time-consuming. Therefore, in the Lab-on-a-chip (LOC) field, an effective microfluidic blood plasma separation platform attracts researchers’ attention globally. Blood plasma self-separation technologies are usually divided into two categories: active self-separation and passive self-separation. Passive self-separation technologies, in contrast with active self-separation, only rely on microchannel geometry, microfluidic phenomena and hydrodynamic forces. Passive self-separation devices are driven by the capillary flow, which is generated due to the characteristics of the surface of the channel and its interaction with the fluid. Comparing to the active plasma separation techniques, passive plasma separation methods are more considered in the microfluidic platform, owing to their ease of fabrication, portable, user-friendly features. We propose an extensive review of mechanisms of passive self-separation technologies and enumerate some experimental details and devices to exploit these effects. The performances, limitations and challenges of these technologies and devices are also compared and discussed.

59 BASIC BIOLOGICAL SCIENCES↗

Wind turbine performance enhancement with minimal structural load penalty: A design philosophy

The performance benefits of using tip devices on wind turbines has been well-documented. However, previous studies show that adding blade tip devices such as winglets leads to a significant increase in blade root bending moment, potentially requiring structural reinforcement with cost and weight drawbacks. A new and unique design philosophy for retrofit blade tip devices for wind turbines is presented. By balancing generated aerodynamic and centrifugal loads, these devices offer an increase in power production without the need for structural reinforcement. Predicted performance and cost benefits of using retrofit blade tip devices on the National Renewable Energy Laboratory 5 MW reference wind turbine are shown. Finally, the addition of blade tip devices resulted in significant improvements in the coefficient of power (C p ) and annual energy production (AEP).

17 WIND ENERGY↗

Use of Machine Learning for Signature Development in a Multi-Sensor Environment for Safeguard Applications of Solvent Extraction Processes

Idaho National Laboratory is constructing the Special Nuclear Material test bed (Beartooth) for research and development pertaining to nuclear fuel processing operations using centrifugal contactors. Beartooth will enable give researchers the opportunity to study the dissolution, separation, and conversion of special nuclear materials (e.g., plutonium, enriched uranium, and thorium). As a lead-in to Beartooth, this project constructed a test bed to study the process and equipment behavior with real time series data collection using a variety of non-traditional sensors, in order to identify process failures and label them as either accidental or purposeful, thus enhancing nuclear nonproliferation stewardship. The measurement sources in this test bed include vibration, acoustic, current, flow, colorimetric, and thermal data. These measurements vary in terms of magnitude, frequency, and location. This information will be combined and used within data-driven machine-learning methods to detect operation condition changes that are either intentional (i.e., changes in operating set points) or malicious (i.e., flow diversion) in nature. This presentation covers the data processing and signature development activities necessary for utilizing this heterogeneous dataset to classify process anomalies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Impact of the adhesion-force lever-arm “a” on the Rock ‘n’ Roll resuspension model and how to compute it from contact mechanics

The paper proposes a methodology to fill a gap in the context of mechanistic particle resuspension models related to the adhesion and lift force lever arms ( a ): to date, only one experimental observation exists from a centrifuge experiment with a specific particle/surface pair which found r P / a = 100 and assumed that the contact points were symmetric with respect to the particle center. However, the Reeks and Hall’s (2001) model is highly sensitive to this parameter, which therefore cannot be used as-is for different particle diameters or materials. This paper proposes a methodology to compute the adhesion and lift force lever arms ( a A and a L , respectively) based on Atomic Force Microcopy (AFM) surface roughness measurements and contact mechanics arguments. In practice, a spherical, perfectly smooth particle is brought in contact (computationally) with the measured surface roughness and is then rotated by the point of contact to determine the two or more asperities over which the particle would sit on the surface. A method to compute the asperity radius of curvature is devised to compute the asperity deformation and the correct partitioning of the total deformation between the particle and the asperity is presented. For the glass surface under consideration, the asperity deformation was negligible, i.e., it was below the van der Waals radius, which is the limit of applicability of contact mechanics. The Reeks and Hall’s (2001) model is then extended to account for the joint probability of a A and a L . Significant differences in particle resuspended after a day in common atmospheric conditions are found between the approach that uses the lever-arm distributions or their mean values. Also, important differences are found when comparing the lever-arm distribution and r P / a = 100. Hence, one should be cautious of using r P / a = 100 for surface/particle pairs differing from those in the original study. Finally, limits of applicability of the theories used are presented together with considerations regarding how to extend the method to non-spherical particles and different materials.

42 ENGINEERING↗

Synthesis of Lanthanide-Based Intermetallic Silicides

Lanthanide-containing materials are of interest because of their useful magnetic and electronic behavior. To study this intrinsic behavior, researchers need high-quality single crystals to avoid interference from grain boundaries or defects commonly found in polycrystalline samples. One method for growing single crystals is metal-flux synthesis, an approach that promotes crystal growth at lower reaction temperatures thus providing access to complex intermetallic phases. My project focuses on synthesizing novel lanthanide-containing intermetallic silicides related to previously reported f-element compounds with the Gd1??Fe4Si10?? structure type. I investigated reactions targeting lanthanum, praseodymium, neodymium, samarium, europium, and gadolinium-containing products, and used scanning electron microscopy with energy-dispersive X-ray spectroscopy (SEM-EDS) to identify promising lanthanide-containing phases. I prepared reactions by loading lanthanide oxides, Co, Si, Al, and Ga into alumina crucibles in a 0.2:1:1:10:10 Ln2O3/Co/Si/Al/Ga mmol ratio, where Ln = La, Nd, Pr, Sm, Eu, or Gd. The reactions were sealed in quartz tubes, heated in a furnace, and centrifuged to separate crystals from excess flux. Afterwards, I mechanically isolated single crystals and prepared them for characterization. Pr-, Nd-, and Sm-containing reactions were confirmed through SEM-EDS to have formed the targeted quaternary phase. Single crystal X-ray diffraction (SC-XRD) data showed the Nd-containing crystals exhibited a hexagonal unit cell associated with the Gd1??Fe4Si10?? structure type. La- and Eu-containing reactions instead formed competing Co(Al/Ga/Si)3 phase crystals. Single-crystal XRD, powder XRD, and magnetic susceptibility and heat-capacity measurements will be collected for the remaining lanthanide-containing crystals. This data will help determine the complete crystal structure of the lanthanide analogues, their phase purity and whether they exhibit localized magnetic behavior, magnetic ordering, or other electronic signatures that can be compared with the previously reported actinide analogues. The disordered structure of this intermetallic family is associated with unusual magnetic and electronic behavior meaning lanthanide analogues may show potential as thermoelectric materials. Developing new thermoelectric candidate materials is relevant to energy efficiency and waste-heat recovery, which supports DOE’s broader goal of advancing science and technology solutions for America’s energy needs.

37 - INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL C↗

Innovative recycling of high purity silver from silicon solar cells by acid leaching and ultrasonication

Precious and scarce silver (Ag) is used as a front electrical contact in silicon solar panels. With massive amounts of solar panel waste coming to end-of-life, it is imperative to recover all the Ag from these modules. In this paper, we propose a novel method to easily reclaim Ag from end-of-life silicon solar cells using low concentration sulfuric acid (H 2 SO 4 ) leaching followed by ultrasonication. Our process simplifies the Ag recycling procedure by directly recovering the Ag contacts from solar cells, eliminating the need for secondary precipitation/electrodeposition. First, scanning electron microscopy (SEM) with energy dispersive X-ray spectroscopy (EDX) and X-ray photoelectron spectroscopy (XPS) was used to study the leaching and ultrasonication process on rejected solar wafers. Next, a solar panel from landfill was heated in a furnace to burn off the polymer encapsulant. The silicon wafers were then collected from the burning process and leached in 2 M H 2 SO 4 at two different shaking speeds for 48 hours at room temperature. Finally, the end-of-life silicon wafer pieces were collected, sonicated in water, and then the sonication water was centrifuged to show a proof-of-concept to recover the Ag contacts. Inductively coupled plasma optical emission spectroscopy (ICPOES) is used to monitor dissolved elements in the leachate as a function of time and shaking speed. XPS is used to evaluate the composition of the silicon cell wafer surface before and after H 2 SO 4 leaching. SEM is used to image the recovered Ag contacts morphology and EDX confirms the recovered particles contain high amounts of Ag. Furthermore, a proposed schematic illustrates the authors’ hypothesis for the peeling mechanism.

14 SOLAR ENERGY↗

Dynamic separation of gases using microsieves

Separation of light weight molecules, such as nitrogen, argon, and oxygen, from heavier compounds can have significant impacts on energy capture, environmental monitoring, or isotopic applications. Large-scale gas separation techniques, like gas centrifugation and membrane mitigation, can be problematic as they impart tremendous energy and induce high mechanical stress onto the instrumentation. Microsieves, also known as micronozzles or microfunnels, are developed to create physical barriers to separate specific isotopes and gases. Separation is achieved using a converging and diverging micronozzle to impose supersonic gas flow around a curved wall, and it has been used for the separation of heavy actinide isotopes in low weight gas as well as separation of low weight gas compositions of nitrogen and argon back in 1900s. However, systematic reviews of this unique technology are lacking. The application of the Laval style nozzle, which has a converging/diverging entrance fundamental to the micronozzle, is included in this review due to its importance in industrial applications in uranium (U) isotope refinement. Using advanced computational fluid dynamic (CFD) simulations, the extent of gas separation can be modelled. Herein, we first examine the literature and survey recent advances on fabrication techniques for creating curved micronozzles, methods and separation principles used to design devices. Furthermore, we then follow with highlights of CFD simulations applied to evaluate the separation effects using microsieves. Finally, identification of the gap and recommendation for future development and applications are suggested for using intrinsic molecular features and fluidic dynamics in formulating separation strategies.

30 Microfluidics↗

Improved Accuracy in Semi-Experimental Structure Determination by Resolving Problems Associated with Rotation of Principal Inertial Axes of Isotopologues: Structures of 1,3-Oxazole ( c -C 3 H 3 NO)

The rotational spectrum of the normal isotopologue of 1,3-oxazole (c-C 3 H 3 NO) was observed from 43 to 750 GHz. Over 3900 transitions for the ground vibrational state are measured, assigned, and least-squares fit to sextic centrifugally distorted-rotor Hamiltonians. The measured frequencies and resulting spectroscopic constants from this extended spectral range, combined with previous measurements of the nuclear quadrupole coupling constants, will facilitate astronomical searches for oxazole across the majority of the range of modern radiotelescopes. Spectra for a set of 30 oxazole isotopologues, which include multiple isotopic substitutions of each atom, are used to determine the first semi-experimental equilibrium ($r$$^{SE}_{e}$) structure and semi-experimental substitution structure ($r$$^{SE}_{e}$), each using CCSD(T) computed values for the vibration–rotation interaction and electron-mass corrections. The large number of isotopologues, including 21 isotopologues observed for the first time, and the redundant substitutions of each atom provide sufficient spectroscopic information to determine the $r$$^{SE}_{e}$ structure with the expected high level of accuracy and precision (0.0001 or 0.0002 Å in bond distances and 0.013 to 0.025° in bond angles). In the course of this study, we analyzed a known issue for some $r$$^{SE}_{e}$ structure determinations of near-oblate asymmetric tops in which inclusion of individual isotopologues degrades the structure determination. We demonstrate that this problem primarily arises from the difference in the values of the computed vibration–rotation interaction corrections as evaluated at the computed re geometry vs the $r$$^{SE}_{e}$ geometry of the “real” molecule. Our solution to this problem substantially improves the $r$$^{SE}_{e}$ structure of oxazole and likely can be generalized to many other molecules.

Chemical structure↗