Search NASA⌕ Search

SEARCH · Search NASA

Results for “centroid estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Reducing Centroid Error Through Model-Based Noise Reduction

A method of processing the digitized output of a charge-coupled device (CCD) image detector has been devised to enable reduction of the error in computed centroid of the image of a point source of light. The method involves model-based estimation of, and correction for, the contributions of bias and noise to the image data. The method could be used to advantage in any of a variety of applications in which there are requirements for measuring precise locations of, and/or precisely aiming optical instruments toward, point light sources. In the present method, prior to normal operations of the CCD, one measures the point-spread function (PSF) of the telescope or other optical system used to project images on the CCD. The PSF is used to construct a database of spot models representing the nominal CCD pixel outputs for a point light source projected onto the CCD at various positions incremented by small fractions of a pixel.

Lee, Shinhak↗

A Diagnostic Analysis of the Kennedy Space Center LDAR Network: Data Characteristics - 1

An analytic framework is developed in which to analyze climatological VHF (66 MHz) radiation measurements taken by the Kennedy Space Center Lightning Detection and Ranging (LDAR) network. A 19 month noise-filtered sample of LDAR observations is examined using this framework. It is found that the climatological impulsive VHF source density as observed by LDAR falls off approximately 10 dB every 71 km of ground range away from the network centroid (a 31 km e-folding scale). The underlying vertical distribution of impulsive VHF sources is approximately normally distributed with a mean altitude of 9 km and a standard deviation of 2.7 km; this implies that the loss of below-horizon sources has a negligible effect on column-integrated source densities within a 200 km ground range. At medium to far ranges, location errors are primarily radial and have a slightly asymmetric distribution whose standard deviation increases as r(exp 2). Error moments estimated from observed lightning are significantly higher than those from aircraft-based signal generator or analytic estimates. LDAR bulk flash detection efficiency is predicted to be above 90% to 94-113 km range from the network centroid and to fall below 10% at ranges greater than 200-240 km.

Boccippio, D. J.↗

Data Validation in the Kepler Science Operations Center Pipeline

We present an overview of the Data Validation (DV) software component and its context within the Kepler ScienceOperations Center (SOC) pipeline and overall Kepler Science mission. The SOC pipeline performs a transiting planetsearch on the corrected light curves for over 150,000 targets across the focal plane array. We discuss the DV strategy forautomated validation of Threshold Crossing Events (TCEs) generated in the transiting planet search. For each TCE, atransiting planet model is fitted to the target light curve. A multiple planet search is conducted by repeating the transitingplanet search on the residual light curve after the model flux has been removed; if an additional detection occurs, aplanet model is fitted to the new TCE. A suite of automated tests are performed after all planet candidates have beenidentified. We describe a centroid motion test to determine the significance of the motion of the target photocenterduring transit and to estimate the coordinates of the transit source within the photometric aperture; a series of eclipsingbinary discrimination tests on the parameters of the planet model fits to all transits and the sequences of odd and eventransits; and a statistical bootstrap to assess the likelihood that the TCE would have been generated purely by chancegiven the target light curve with all transits removed.

photometry↗

Evaluation of multiple image-based modalities for image-guided radiation therapy (IGRT) of prostate carcinoma: A prospective study

Purpose: Setup errors and prostate intrafraction motion are main sources of localization uncertainty in prostate cancer radiation therapy. This study evaluates four different imaging modalities 3D ultrasound (US), kV planar images, cone-beam computed tomography (CBCT), and implanted electromagnetic transponders (Calypso/Varian) to assess inter- and intrafraction localization errors during intensity-modulated radiation therapy based treatment of prostate cancer. Methods: Twenty-seven prostate cancer patients were enrolled in a prospective IRB-approved study and treated to a total dose of 75.6 Gy (1.8 Gy/fraction). Overall, 1100 fractions were evaluated. For each fraction, treatment targets were localized using US, kV planar images, and CBCT in a sequence defined to determine setup offsets relative to the patient skin tattoos, intermodality differences, and residual errors for each patient and patient cohort. Planning margins, following van Herk's formalism, were estimated based on error distributions. Calypso-based localization was not available for the first eight patients, therefore centroid positions of implanted gold-seed markers imaged prior to and immediately following treatment were used as a motion surrogate during treatment. For the remaining 19 patients, Calypso transponders were used to assess prostate intrafraction motion. Results: The means ({mu}), and standard deviations (SD) of the systematic ({Sigma}) and random errors ({sigma}) of interfraction prostate shifts (relative to initial skin tattoo positioning), as evaluated using CBCT, kV, and US, averaged over all patients and fractions, were: [{mu}{sub CBCT}= (-1.2, 0.2, 1.1) mm, {Sigma}{sub CBCT}= (3.0, 1.4, 2.4) mm, {sigma}{sub CBCT}= (3.2, 2.2, 2.5) mm], [{mu}{sub kV}= (-2.9, -0.4, 0.5) mm, {Sigma}{sub kV}= (3.4, 3.1, 2.6) mm, {sigma}{sub kV}= (2.9, 2.0, 2.4) mm], and [{mu}{sub US}= (-3.6, -1.4, 0.0) mm, {Sigma}{sub US}= (3.3, 3.5, 2.8) mm, {sigma}{sub US}= (4.1, 3.8, 3.6) mm], in the anterior-posterior (A/P), superior-inferior (S/I), and the left-right (L/R) directions, respectively. In the treatment protocol, adjustment of couch was guided by US images. Residual setup errors as assessed by kV images were found to be: {mu}{sub residual}= (-0.4, 0.2, 0.2) mm, {Sigma}{sub residual}= (1.0, 1.0,0.7) mm, and {sigma}{sub residual}= (2.5, 2.3, 1.8) mm. Intrafraction prostate motion, evaluated using electromagnetic transponders, was: {mu}{sub intrafxn}= (0.0, 0.0, 0.0) mm, {Sigma}{sub intrafxn}= (1.3, 1.5, 0.6) mm, and {sigma}{sub intrafxn}= (2.6, 2.4, 1.4) mm. Shifts between pre- and post-treatment kV images were: {mu}{sub kV(post-pre)}= (-0.3, 0.8, -0.2), {Sigma}{sub kV(post-pre)}= (2.4, 2.7, 2.1) mm, and {sigma}{sub kV(post-pre)}= (2.7, 3.2, 3.1) mm. Relative to skin tattoos, planning margins for setup error were within 10-11 mm for all image-based modalities. The use of image guidance was shown to reduce these margins to less than 5 mm. Margins to compensate for both residual setup (interfraction) errors as well as intrafraction motion were 6.6, 6.8, and 3.9 mm in the A/P, S/I, and L/R directions, respectively. Conclusions: Analysis of interfraction setup errors, performed with US, CBCT, planar kV images, and electromagnetic transponders, from a large dataset revealed intermodality shifts were comparable (within 3-4 mm). Interfraction planning margins, relative to setup based on skin marks, were generally within the 10 mm prostate-to-planning target volume margin used in our clinic. With image guidance, interfraction residual planning margins were reduced to approximately less than 4 mm. These findings are potentially important for dose escalation studies using smaller margins to better protect normal tissues.

60 APPLIED LIFE SCIENCES↗

A method to estimate the motion of unresolved VLBI components in extragalactic radio sources - The case of NRAO 140

A method is proposed for estimating the relative motion of two blended VLBI compact components from measurements of the motion of their brightness centroid. The method requires a priori information about the source components, such as flux densities and separate knowledge of the motion of one of the blended components. Observations of the superluminal quasar NRAO 140 are analyzed to test the technique. Superluminal motion is found for the blended component A2 at 6-cm wavelength with an apparent velocity of about 5c (H0 = 100 km/s/Mpc, q0 = 0.5, z = 1.258).

Charlot, P.↗

Data Validation in the Kepler Science Operations Center Pipeline

We present an overview of the Data Validation (DV) software component and its context within the Kepler Science Operations Center (SOC) pipeline and overall Kepler Science mission. The SOC pipeline performs a transiting planet search on the corrected light curves for over 150,000 targets across the focal plane array. We discuss the DV strategy for automated validation of Threshold Crossing Events (TCEs) generated in the transiting planet search. For each TCE, a transiting planet model is fitted to the target light curve. A multiple planet search is conducted by repeating the transiting planet search on the residual light curve after the model flux has been removed; if an additional detection occurs, a planet model is fitted to the new TCE. A suite of automated tests are performed after all planet candidates have been identified. We describe a centroid motion test to determine the significance of the motion of the target photocenter during transit and to estimate the coordinates of the transit source within the photometric aperture; a series of eclipsing binary discrimination tests on the parameters of the planet model fits to all transits and the sequences of odd and even transits; and a statistical bootstrap to assess the likelihood that the TCE would have been generated purely by chance given the target light curve with all transits removed. Keywords: photometry, data validation, Kepler, Earth-size planets

Wu, Hayley↗

Parameter Estimation of Gaussian-Damped Sinusoids from a Geometric Perspective

The five parameter gaussian damped sinusoid equation is a reasonable model for betatron motion with chromatic decoherence of the proton bunch centroid signal in the ring at the Spallation Neutron Source. A geometric method for efficiently fitting this equation to the turn by turn signals to extract the betatron tune and damping constant will be presented. This method separates the parameters into global and local parameters and allows the use of vector arithmetic to eliminate the local parameters from the parameter search space. Furthermore, this method is easily generalized to reduce the parameter search space for a larger class of problems.

97 MATHEMATICS AND COMPUTING↗

Predicted range expansion of Prostephanus truncatus (Coleoptera: Bostrichidae) under projected climate change scenarios

Abstract The larger grain borer (Prostephanus truncatus [Horn] [Coleoptera: Bostrichidae]) is a wood-boring insect native to Central America and adapted to stored maize and cassava. It was accidentally introduced to Tanzania and became a pest across central Africa. Unlike many grain pests, P. truncatus populations can establish and move within forests. Consequently, novel infestations can occur without human influence. The objectives of our study were to (i) develop an updated current suitability projection for P. truncatus, (ii) assess its potential future distribution under different climate change scenarios, and (iii) identify climate variables that best inform the model. We used WALLACE and MaxEnt to predict potential global distribution by incorporating bioclimatic variables and occurrence records. Future models were projected for 2050 and 2070 with Representative Concentration Pathways (RCPs) 2.6 (low change) and 8.5 (high change). Distribution was most limited by high precipitation and cold temperatures. Globally, highly suitable areas (> 75%) primarily occurred along coastal and equatorial regions with novel areas in northern South America, India, southeastern Asia, Indonesia, and the Philippines, totaling 7% under current conditions. Highly suitable areas at RCPs 2.6 and 8.5 are estimated to increase to 12% and 15%, respectively, by 2050 and increase to 19% in 2070 under RCP 8.5. Centroids of highly suitable areas show distribution centers moving more inshore and away from the equator. Notably, the result is a range expansion, not a shift. Results can be used to decrease biosecurity risks through more spatially explicit and timely surveillance programs for targeting the exclusion of this pest.

Entomology↗

Kepler Planet Detection Mission: Introduction and First Results

The Kepler Mission is designed to determine the frequency of Earth-size and rocky planets in and near the habitable zone (HZ) of solar-like stars. The HZ is defined to be the region of space where a rocky planet could maintain liquid water on its surface. Kepler is the 10th competitively-selected Discovery Mission and was launched on March 6, 2009. Since completing its commissioning, Kepler has observed over 156,000 stars simultaneously and near continuously to search for planets that periodically pass in front of their host star (transit). The photometric precision is approximately 23 ppm for 50% of the 12th magnitude dwarf stars for an integration period of 6.5 hours. During the first 3 months of operation the photometer detected transit-like signatures from more than 200 stars. Careful examination shows that many of these events are false-positives such as small stars orbiting large stars or blends of target stars with eclipsing binary stars. Ground-based follow-up observations confirm the discovery of five new exoplanets with sizes between 0.37 andl.6 Jupiter radii (R(sub J)) and orbital periods ranging from 3.2 to 4.9 days. Ground-based observations with the Keck 1, Hobby-Ebberly, Hale, WIYN, MMT, Tillinghast, Shane, and Nordic Optical Telescopes are used to vet the planetary candidates and measure the masses of the putative planets. Observations of occultations and phase variations of hot, short-period planets such as HT-P-7b provide a probe of atmospheric properties. Asteroseismic analysis already shows the presence of p-mode oscillations in several stars. Such observations will be used to measure the mean stellar density and infer the stellar size and age. For stars too dim to permit asteroseismology, observations of the centroid motion of target stars will be used to measure the parallax and be combined with photometric measurements to estimate stellar sizes. Four open clusters are being observed to determine stellar rotation rates as a function of age and spectral type. Many different types of stellar variability are observed with unprecedented precision and over a wide range of time scales. Solar-like photometric variability of thousands of field stars is being studied to determine how photometric variability and the stellar rotation rates change with stellar age and metallicity. A wide variety of other astrophysical phenomena have also been observed. The data are being analyzed at the Ames Research Center and archived at the MAST at STScI. The Kepler Mission also supports a vigorous Guest Observer Program.

Borucki, William↗

Noise estimation of beam position monitors at RHIC

Beam position monitors (BPM) are used to record the average orbits and transverse turn-by-turn displacements of the beam centroid motion. The Relativistic Hadron Ion Collider (RHIC) has 160 BPMs for each plane in each of the Blue and Yellow rings: 72 dual-plane BPMs in the insertion regions (IR) and 176 single-plane modules in the arcs. Each BPM is able to acquire 1024 or 4096 consecutive turn-by-turn beam positions. Inevitably, there are broadband noisy signals in the turn-by-turn data due to BPM electronics as well as other sources. A detailed study of the BPM noise performance is critical for reliable optics measurement and beam dynamics analysis based on turn-by-turn data.

43 PARTICLE ACCELERATORS↗

TH-AB-202-12: The First Clinical Implementation of a Real-Time Six Degree of Freedom Tracking System During Radiation Therapy

Purpose: In current practice, imaging is typically performed prior to treatment; the cancer target motion during treatment is unknown. We present the first clinical implementation of real time Kilovoltage Intrafraction Monitoring (KIM) system which tracks the cancer target translational and rotational motions during treatment. Methods: KIM technology: KIM estimates the 3D position of the target tumour based on segmented 2D positions of the three implanted fiducials in each of the kV images (125 kV, 10 mA at 11 fps) taken continuously during the treatment arc. The 2D-3D target estimation is based on a probability distribution function, obtained during pre-treatment CBCT. Rotations about each axis with the centroid of the markers as the pivot were calculated using the iterative closest point algorithm in real time. Patient: A patient with prostate adenocarcinoma undergoing stereotactic body radiotherapy (SBRT) with 36.25 Gy delivered in 5 fractions (Varian TrueBeam, 6X, VMAT) was enrolled in the study. The trial complies with Australian ethical and regulatory standards. Results: Of the 5 fractions of treatment the patient received, KIM was utilised successfully in 4 fractions with 3 couch shifts due to large persistent prostate movements (>2mm for more than 5 seconds). KIM translational accuracy and precision in comparison with post treatment kV-MV triangulation are 0.28±0.59 mm, −0.19±0.25 mm and 0.23±0.69 mm in the Left-Right, Superior-Inferior and Anterior-Posterior directions, respectively. KIM rotational accuracy as compared with triangulation is: 0.429°±2.22°, −0.44°±4.7° and 0.06°±1.08° in the roll, pitch and yaw direction, respectively. Conclusion: The first six degree of freedom KIM system was successfully implemented clinically. The presented KIM system has sub-millimeters accuracy and precision in all three translational axes, and less than 1° of mean error in all three rotational axes. Acknowledgement: This work is supported by Cancer Australia grants APPXXX, APPYYY.

60 APPLIED LIFE SCIENCES↗

Model America - Arizona extract from ORNL's AutoBEM v1.1

Oak Ridge National Laboratory (ORNL) has developed the Automatic Building Energy Modeling (AutoBEM) software suite to process multiple types of data, extract building-specific descriptors, generate building energy models, and simulate them on High Performance Computing (HPC) resources. For more information, see AutoBEM-related publications (bit.ly/AutoBEM).Two sets of sample data are provided for 2,555,152 buildings located within the boundary of Arizona in the United States:Data (846.3MB *.csv) - minimalist list of each building (rows) for the following fields (columns) • ID - unique building ID • Centroid - building center location in latitude/longitude (from Footprint2D) • Footprint2D - building polygon of 2D footprint (lat1/lon1_lat2/lon2_...) • State_abbr - state name • Area - estimate of total conditioned floor area (ft2) • Area2D - footprint area (ft2) • Height - building height (ft) • NumFloors - number of floors (above-grade) • WWR_surfaces - percent of each facade (pair of points from Footprint2D) covered by fenestration/windows (average 14.5% for residential, 40% for commercial buildings) • CZ - ASHRAE Climate Zone designation • BuildingType - DOE prototype building designation (IECC=residential) as implemented by OpenStudio-standards • Standard - building vintage • Sample Models (114GB*.zip by county) - OpenStudio and EnergyPlus building energy models named according to IDThis data is made free and openly available in hopes of stimulating any simulation-informed use case. Data is provided as-is with no warranties, express or implied, regarding fitness for a particular purpose. We wish to thank our sponsors which include Oak Ridge National Laboratory (ORNL), U.S. Dept. of Energy’s (DOE) Building Technologies Office (BTO), Office of Electricity (OE), and Biological and Environmental Research (BER).

54 ENVIRONMENTAL SCIENCES↗

The Progenitor of the New COMPTEL/ROSAT Supernova Remnant in Vela

We show that (1) the newly discovered supernova remnant (SNR) GROJ0852-4642/RXJ0852.0-4622 was created by a core-collapse supernova of a massive star and (2) the same supernova event that produced the Ti-44 detected by COMPTEL from this source is probably also responsible for a large fraction of the observed Al-26 emission in the Vela region detected by the same instrument. The first conclusion is based on the fact that the remnant is currently expanding too slowly given its young age for it to be caused by a Type la supernova. If the current SNR shell expansion speed is greater than 3000 km/s, a 15 solar mass. Type II supernova with a moderate kinetic energy exploding at about 150 pc away is favored. If the SNR expansion speed is lower than 2000 km/s, as derived naively from X-ray data, a much more energetic supernova is required to have occurred at approximately 250 pc away in a dense environment at the edge of the Gum Nebula. This progenitor has a preferred ejecta mass of less than or equal to 10(Solar Mass), and therefore it is probably a Type Ib or Type Ic supernova. However, the required high ambient density of n(sub H) greater than or equal to 100 cu cm in this scenario is difficult to reconcile with the regional CO data. A combination of our estimates of the age/energetics of the new SNR and the almost perfect positional coincidence of the new SNR with the centroid of the COMPTEL Al-26 emission feature of the Vela region strongly favors a causal connection. If confirmed, this will be the first case in which both Ti-44 and Al-26 are detected from the same young SNR, and together they can be used to select preferred theoretical core-collapse supernova models.

Chen, Wan↗

Stereology of backscatter electron images of etched surfaces for characterization of particle size distributions and volume fractions: Estimation of imaging bias via Monte Carlo simulations

On metallic specimens in which a secondary phase has been selectively removed by a chemical etchant, the use of backscatter electron (BSE) imaging yields images that are more readily segmented with image processing algorithms than other modes of imaging in the scanning electron microscope. The contrast mechanisms in this imaging mode, however, produce a bias in the observation of particle sizes and volume fractions due to the effects of the electron interaction volume in the specimen. This stereological bias is quantified using Monte Carlo (MC) simulation of backscatter images. It is observed that the overprojection of features with centroids residing beneath the plane of polish is largely canceled out by the reduced segmentation size of features with centroids residing above the plane of polish. - Research Highlights: {yields} Backscatter imaging of selectively-etched surfaces can facilitate segmentation. {yields} Backscatter imaging of voids is simulated to estimate imaging/observation biases. {yields} The biases are quantified and incorporated into the stereological calculation. {yields} Systematic errors and imaging biases are observed to counteract one another. {yields} Results are illustrated using a bimodal gamma prime distribution in a Ni superalloy.

36 MATERIALS SCIENCE↗

Image Moment-Based Extended Object Tracking for Complex Motions

A novel image moment-based model for shape estimation and tracking of an extended target moving with a complex trajectory is presented. The proposed extended object tracking algorithm is based on multiple noisy measurement points sampled from the target at each time step. The shape of the object, approximated by an ellipse, is estimated using a combination of image moments. Dynamic models of image moments for constant velocity and coordinated turn motions are mathematically derived. An unscented Kalman filter - interacting multiple model (UKF-IMM) method is used to track the object and estimate its shape. A likelihood function based on average log-likelihood is derived for the IMM filter. Simulation results of the proposed UKF-IMM algorithm with the image momentbased models are presented that show the estimation of the shape of the object moving in a complex trajectory. The intersection over union (IoU), and the root mean square errors (RMSEs) of the position and velocity of the centroid of the ellipse are used as metrics. The comparison results of the proposed algorithm with a benchmark algorithm from literature based on the IoU and RMSE metrics are presented.

Extended object tracking↗

A Pn magnitude scale m b ( Pn ) for earthquakes along the equatorial Mid-Atlantic Ridge

We developed a short-period Pn magnitude scale m b (Pn) for earthquakes along the equatorial Mid-Atlantic Ridge. Due to low signal-to-noise ratios, teleseismic body wave magnitude and long-period surface wave magnitude cannot be confidently determined for small earthquakes of m b < 4. Local magnitude scales are also not useful for these events because the oceanic environment does not allow the propagation of crustal phases. However, regional high-frequency Pn waves from these small- to moderate-size (m b 3–6) earthquakes are well recorded in the equatorial Atlantic region and can be used to assign magnitudes. We measured over 2041 Pn peak amplitudes on vertical records from about 21 stations in northeastern Brazil and 11 stations in western Africa in the distance range of 700–3700 km. We analysed data from 189 events from the global centroid moment tensor catalogue to tie our m b (Pn) scale to M w so that seismic moments can be readily estimated. Pn arrivals show apparent group velocity between 7.9 km s –1 at short ranges (~1000 km) and up to 9.1 km s –1 at 3500 km. The measured peak amplitudes have a frequency between 0.8 and 3 Hz at 1000–1800 km, but at greater distances, 1800–3700 km, they show a remarkably consistent frequency of about 0.8 Hz. The peak amplitude attenuates at a higher rate at short distances (~0.65 magnitude units between 700 and 2000 km) but attenuates at a lower rate at long distances (~0.35 magnitude units between 2000 and 3700 km). The low rate of amplitude decay with distance and nearly constant frequency content of the peak amplitudes suggest that Pn waves propagate efficiently in the lower part of the upper mantle in the equatorial Atlantic Ocean basins. Furthermore, these are important attributes of oceanic Pn waves that can be used to assign magnitude for small- to moderate-size earthquakes in the equatorial mid-Atlantic region. The estimated station corrections correlate well with upper mantle low-velocity anomalies, especially in Brazil.

58 GEOSCIENCES↗

Structure and kinematics of the broad-line regions in active galaxies from IUE variability data

IUE archival data are used here to investigate the structure nad kinematics of the broad-line regions (BLRs) in nine AGN. It is found that the centroid of the line-continuum cross-correlation functions (CCFs) can be determined with reasonable reliability. The errors in BLR size estimates from CCFs for irregularly sampled light curves are fairly well understood. BLRs are found to have small luminosity-weighted radii, and lines of high ionization tend to be emitted closer to the central source than lines of low ionization, especially for low-luminosity objects. The motion of the gas is gravity-dominated with both pure inflow and pure outflow of high-velocity gas being excluded at a high confidence level for certain geometries.

Koratkar, Anuradha P.↗

Optimal Calibration of the Spitzer Space Telescope

A document discusses the focal-plane calibration of the Spitzer Space Telescope by use of the instrument pointing frame (IPF) Kalman filter, which was described in Kalman Filter for Calibrating a Telescope Focal Plane (NPO-40798), NASA Tech Briefs, Vol. 30, No. 9 (September 2006), page 62. To recapitulate: In the IPF Kalman filter, optimal estimates of both engineering and scientific focal-plane parameters are obtained simultaneously, using data taken in each focalplane survey activity. The IPF Kalman filter offers greater efficiency and economy, relative to prior calibration practice in which scientific and engineering parameters were estimated by separate teams of scientists and engineers and iterated upon each other. In the Spitzer Space Telescope application, the IPF Kalman filter was used to calibrate 56 frames for precise telescope pointing, estimate >1,500 parameters associated with focal-plane mapping, and process calibration runs involving as many as 1,338 scientific image centroids. The final typical survey calibration accuracy was found to be 0.09 arc second. The use of the IPF Kalman filter enabled a team of only four analysts to complete the calibration processing in three months. An unanticipated benefit afforded by the IPF Kalman filter was the ability to monitor health and diagnose performance of the entire end-to-end telescope-pointing system.

Bayard, David↗