Search NASA⌕ Search

SEARCH · Search NASA

Results for “chromium”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Cycling performance of the iron-chromium redox energy storage system

Extended charge-discharge cycling of this electrochemical storage system at 65 C was performed on 14.5 sq cm single cells and a four cell, 867 sq cm bipolar stack. Both the anolyte and catholyte reactant fluids contained 1 molar concentrations of iron and chromium chlorides in hydrochloric acid and were separated by a low-selectivity, cation-exchange membrane. The effect of cycling on the chromium electrode and the cation-exchange membrane was determined. Bismuth and bismuth-lead catalyzed chromium electrodes and a radiation-grafted polyethylene membrane were evaluated by cycling between 5 and 85 percent state-of-charge at 80 mA/sq cm and by periodic charge-discharge polarization measurements to 140 mA/sq cm. Gradual performance losses were observed during cycling but were recoverable by completely discharging the system. Good scale-up to the 867 sq cm stack was achieved. The only difference appeared to be an unexplained resistive-type loss which resulted in a 75 percent W-hr efficiency (at 80 mA/sq cm versus 81 percent for the 14.5 sq cm cell). A new rebalance cell was developed to maintain reactant ionic balance. The cell successfully reduced ferric ions in the iron reactant stream to ferrous ions while chloride ions were oxidized to chlorine gas.

Gahn, R. F.↗

Composition optimization of chromium carbide based solid lubricant coatings for foil gas bearings at temperatures to 650 C

A test program to determine the optimum composition of chromium carbide based solid lubricant coatings for compliant gas bearings is described. The friction and wear properties of the coatings are evaluated using a foil gas bearing test apparatus. The various coatings were prepared by powder blending, then plasma sprayed onto Inconel 718 test journals and diamond ground to the desired coating thickness and surface finish. The journals were operated against preoxidized nickel-chromium alloy foils. The test bearings were subjected to repeated start/stop cycles under a 14 kPa (2 psi) bearing unit load. The bearings were tested for 9000 start/stop cycles or until the specimen wear reached a predetermined failure level. In general, the addition of silver and eutectic to the chromium carbide base stock significantly reduced foil wear and increased journal coating wear. The optimum coating composition, PS212 (70 wt% metal bonded Cr3C2, 15 wt% Ag, 15% BaF2/CaF2 eutectic), reduced foil wear by a factor of two and displayed coating wear well within acceptable limits. The load capacity of the bearing using the plasma-sprayed coating prior to and after a run-in period was ascertained and compared to polished Inconel 718 specimens.

Dellacorte, Christopher↗

Composition optimization of self-lubricating chromium-carbide-based composite coatings for use to 760 C

This paper describes new compositions of self-lubricating coatings that contain chromium carbide. A bonded chromium carbide was used as the base stock because of the known excellent wear resistance and the chemical stability of chromium carbide. Additives were silver and barium fluoride/calcium fluoride eutectic. The coating constituents were treated as a ternary system consisting of: (1) the bonded carbide base material, (2) silver, and (3) the eutectic. A study to determine the optimum amounts of each constituent was performed. The various compositions were prepared by powder blending. The blended powders were then plasma sprayed onto superalloy substrates and diamond ground to the desired coating thickness. Friction and wear studies were performed at temperatures from 25 to 760 C in helium and hydrogen. A variety of counterface materials were evaluated with the objective of discovering a satisfactory metal/coating sliding combination for potential applications such as piston ring/cylinder liner couples for Stirling engines.

Dellacorte, Chris↗

Changes in oxidation state of chromium during LDEF exposure

The solar collector used for the McDonnell-Douglas Cascade Variable Heat Pipe, Experiment A0076 (Michael Grote - Principal Investigator) was finished with black chromium plating as a thermal control coating. The coating is metallic for low emittance, and is finely microcrystalline to a dimension which yields its high absorptivity. An underplate of nickel was applied to the aluminum absorber plate in order to achieve optimal absorptance characteristics from the black chromium plate surface. Experiment A0076 was located at tray position F9, receiving a projected 8.7 x 10 exp 21 atomic oxygen atoms/sq cm and 11,200 ESH solar radiation. During retrieval, it was observed that the aluminized kapton thermal blankets covering most of the tray were severely eroded by atomic oxygen, and that a 'flap' of aluminum foil was overlaying a roughly triangular shaped portion of the absorber panel. The aluminum foil 'flap' was lost sometime between the Long Duration Exposure Facility (LDEF) retrieval and deintegration. At deintegration, the black chromium was observed to have discolored where it had been covered by the foil 'flap'. A summary of the investigation into the cause of the discoloration is presented.

Golden, Johnny L.↗

Survey of Portions of the Chromium-Cobalt-Nickel-Molybdenum Quaternary System at 1,200 Degrees C

A survey was made of portions of the chromium-cobalt-nickel-molybdenum quaternary system at 1,200 degrees c by means of microscopic and x-ray diffraction studies. Since the face-centered cubic (alpha) solid solutions form the matrix of almost all practically useful high-temperature alloys, the solid solubility limits of the quaternary alpha phase were determined up to 20 percent molybdenum. The component cobalt-nickel-molybdenum, chromium-cobalt-molybdenum, and chromium-nickel-molybdenum ternary systems were also studied. The survey of these systems was confined to the determination of the boundaries of the face-centered cubic (alpha) solid solutions and of the phases coexisting with alpha at 1,200 degrees c.

Rideout, Sheldon Paul↗

Development of Protective Coatings for Chromium-Base Alloys

Chromium alloy sheet was clad with 5 to 10-mil-thick oxidation-resistant nickel-base alloy foils. Specimens also contained 1/2 to 1-mil-thick intermediate layers of platinum, tungsten, and/or W-25Re. Cladding was done by the isostatic hot gas-pressure bonding,.process. The clad chromium-alloy specimens were cyclic oxidation tested at 2100 F and 2300 F for up to 200 hours to determine the effectiveness of these metal claddings in protecting the chromium alloy Cr-5W from oxidation and contamination. Cladding systems consisting of 5-mil-thick Ni-20Cr-20W modified with 3 to 5 weight percent aluminum and containing a 1 /2-mil tungsten diffusion barrier demonstrated potential for long-time service at temperatures as high as 2300 F.

English, J. J.↗

Techniques for Achieving Zero Stress in Thin Films of Iridium, Chromium, and Nickel

We examine techniques for achieving zero intrinsic stress in thin films of iridium, chromium, and nickel deposited by magnetron sputter deposition. The intrinsic stress is further correlated to the microstructural features and physical properties such as surface roughness and optical density at a scale appropriate to soft X-ray wavelengths. The examination of the stress in these materials is motivated by efforts to advance the optical performance of light-weight X-ray space telescopes into the regime of sub-arcsecond resolution through various deposition techniques that rely on control of the film stress to values within 10-100 MPa. A characteristic feature of the intrinsic stress behavior in chromium and nickel is their sensitivity to the magnitude and sign of the intrinsic stress with argon gas pressure and deposition rate, including the existence of a critical argon process pressure that results in zero film stress which scales linearly with the atomic mass of the sputtered species. While the effect of stress reversal with argon pressure has been previously reported by Hoffman and others for nickel and chromium, we report this effect for iridium. In addition to stress reversal, we identify zero stress in the optical functioning iridium layer shortly after island coalescence for low process pressures at a film thickness of approximately 35nm. The measurement of the low values of stress during deposition was achieved with the aid of a sensitive in-situ instrument capable of a minimum detectable level of stress, assuming a 35nm thick film, in the range of 0.40-6.0 MPa for <111> oriented crystalline silicon substrate thicknesses of 70-280 microns, respectively.

X-ray optical thin films↗

Achieving Zero Stress in Iridium, Chromium, and Nickel Thin Films

We examine a method for achieving zero intrinsic stress in thin films of iridium, chromium, and nickel deposited by magnetron sputter deposition. The examination of the stress in these materials is motivated by efforts to advance the optical performance of light-weight x-ray space telescopes into the regime of sub-arc second resolution that rely on control of the film stress to values within 10-100 MPa. A characteristic feature of the intrinsic stress behavior in chromium and nickel is their sensitivity to the magnitude and sign of the intrinsic stress with argon gas pressure, including the existence of a critical pressure that results in zero film stress. This critical pressure scales linearly with the film's density. While the effect of stress reversal with argon pressure has been previously reported by Hoffman and others for nickel and chromium, we have discovered a similar behavior for iridium. Additionally, we have identified zero stress in iridium shortly after island coalescence. This feature of film growth is used for achieving a total internal stress of -2.89 MPa for a 15.8 nm thick iridium film. The surface roughness of this low-stress film was examined using scanning probe microscopy (SPM) and x-ray reflectivity (XRR) at CuKα and these results presented and discussed.

X-ray↗

Hexavalent Chromium IV-Free Primer Development

Primer materials provide corrosion protection for metal parts as well as an increased adhesion between metallic substrates and thermal protection systems (TPSs). Current primers for use in cryogenic applications contain hexavalent chromium. This hexavalent chromium provides excellent corrosion protection even in a cryogenic environment, but it is a carcinogen that requires special equipment and waste control procedures to use. The hazardous nature of hexavalent chromium makes it an obsolescence risk in the future. This study included two phases of evaluation. Thirteen primers were initially identified as candidates and twelve of those primers were tested in phase 1. Four of the best performing candidates from phase 1 continued into phase 2 testing. Phase 1 testing consisted mostly of liquid constituent and physical property testing. Cryoflex and salt fog testing were included in phase 1 because of their importance to the overall success of a candidate material. Phase 2 consisted of physical, thermal, and mechanical properties for nominally processed and fabricated specimens.

Alldredge, Michael J.↗

Pre-Demonstration Development of Controlled-Release Corrosion Inhibitors and Healing Agents as Alternatives to Hexavalent Chromium

This Limited Scope Study was directed to achieve the following objectives: (1) Scale-up of materials that can meet MIL-PRF-23377 (solvent-based primer). (2) Provide evidence of resistance to aircraft alkaline cleaners and de-icing fluids. (3) Provide formulation for initial ecological and toxicity screening. (4) Submit an interim report that will provide the basis for a future ESTCP (the Dept. of Defense's (DoD's) Environmental Security Technology Certification Program) demonstration effort.The encapsulation procedure for two corrosion inhibitors was scaled up from lab scale to 2.0 kilograms. This scale will accommodate high volume production of coatings with encapsulated corrosion inhibitors for large surface areas during a follow-on ESTCP demonstration effort. Test results provided evidence of resistance to alkaline cleaners and aircraft de-icing fluids and compliance with MIL-PRF-23377. All the MIL-PRF-23377 requirements were met with the exception of the adhesion requirement, in top coated panels, and the flexibility requirement. Work on solving these two problems will be done prior to validation and demonstration of the technology. An initial ecological and toxicity screening identified several factors that were not critical to the acceptance of the encapsulated corrosion inhibitor. This new technology will lead to environmentally friendly alternatives to hexavalent chromium that will enable DoD to protect its assets. Field demonstration, licensing, qualification, and commercialization will allow its real world utilization. Abstract for Appendix A. Toxicology Report: Corrosion controls a significant problem for military equipment. Many surface treatment materials currently in use on items of military or aerospace materiel contain chromium (VI) as a component, a source of significant human health and environmental hazard. The formulation under evaluation contains no chromium. Most of the proposed components are low to moderate toxicity and are not a significant concern. Two of the formulation components are associated with some cancer hazard - 2-mercaptobenzothiazole and formaldehyde, but both find widespread use in industry and additional investigation is not required for this project.

Calle, Luz Marina↗

Removal of Residual Chromium from Aluminum Oxide by Containerless Liquid-phase Processing

Berneuil sapphire was purified of Cr 3+ by containerless melting and processing at ca. 2550 K in high purity argon, dry air and pure oxygen. Recovered material was examined by laser induced fluorescence and Raman spectroscopy. The Cr 3+ fluorescence intensity decreased in processed specimens at rates proportional to the chromium concentration and p(O 2 ) 0.21 . The initial chromium concentration was ca. 5 ppm and decreased by factors of ca. 50, 3000, and 2x10 5 after processing for 300 seconds in argon, air and oxygen, respectively. Evidence is presented that the Cr 3+ was removed predominantly as CrO 2 (g) and not by conversion to other oxidation states of chromium in the condensed phase. A comparison of the Raman peak shifts for as-received and processed samples indicates that considerable stress was retained during containerless solidification of the highly undercooled melts.

sapphire↗

Enhanced flow boiling heat transfer on chromium coated zircaloy-4 using cold spray technique for accident tolerant fuel (ATF) materials

Flow boiling heat transfer tests were conducted to evaluate the Critical Heat Flux (CHF) and Heat Transfer Coefficient (HTC) of conventional and accident tolerant fuel (ATF) cladding materials, i.e., bare Zircaloy-4 (Zr4), and Zircaloy-4 coated with Chromium using physical vapor deposition (PVD) (Zr4-Cr-PVD) and cold spray process (Zr4-Cr-CS), respectively. The tests were performed on a single heater rod with a uniform heat flux profile, at the atmospheric pressure, inlet temperature (24 °C) and mass flow rate (750 kg/m 2 s). HTC’s were increased by 5.2% and 3.3% on Zr4-Cr-CS compared to bare Zr4 and Zr4-Cr-PVD. Improved HTCwas attributed to the increased void fraction and high roughness (Ra = 532 nm) of the Zr4-Cr-CS. In detail, the micro-cavities, which act as bubble seeds, were entirely distributed on the Zr4-Cr-CS, and these micro-cavities generated smaller and faster bubbles, thus the void fraction increased by 10.9% compared to bare Zr4. HTC is improved by these smaller and faster bubbles which can remove heat from the heater rod surface more efficiently. To identify the exact location of CHF, the surface temperature profile was measured using advanced fiber-optic sensors which have high temporal/spatial resolution (distance between point to point: ~2.5 mm, frequency ~100 Hz). CHF occurred at 80–95% along the heated length and showed an 11.6% reduction on Zr4-Cr-CS compared to bare Zr4. We hypothesize the CHF reduction was caused by the lower wettability of the Zr4-Cr-CS which reduces the liquid supply to the surface, and vigorous bubble accumulation owing to high void fraction near the outlet, which results in early formation of the vapor film. During the post-CHF quenching phase, the rougher Zr4-Cr-CS showed larger cooling rates compared to the bare Zr4 and Zr4-Cr-PVD, preventing of oxidation by chromium layer. In conclusion, we demonstrate that the high roughness on the Zr4-Cr-CS increased the number of micro-cavities on the surface, resulting in 5.2% increase in HTC and improvement in the quenching heat transfer performance whereas CHF was 11.6% reduced compared to bare Zr4. Overall statistically there is little effect in the coating with regards to CHF and slight improvement in HTC.

42 ENGINEERING↗

Chromium isotopes in an acidic fluvial system: Implications for modern and ancient Cr isotope records

Chromium is an important redox-active element, with significant Cr isotope fractionations driven by redox transformations in the natural environment and quantified through laboratory experiments. Recent work has demonstrated that non-redox-driven transformations can also produce small variations in Cr isotopes, but the role of these processes in controlling environmental Cr isotope variations remains unclear. The highly acidic but biologically diverse acid rock drainage system in Río Tinto, Spain (and affiliated rivers) provides a unique opportunity to examine how non-redox-related processes can substantially affect the isotopic composition of Cr in a natural system. Our results suggest that under conditions where Cr redox transformations are obviated, Cr cycling is largely controlled by formation of Fe-oxyhydroxides and Fe-hydroxysulfates, Cr adsorption, and Cr speciation, with little apparent Cr isotope fractionation between source materials, waters, and sediments. Moderate Cr isotope shifts, however, may be the result of non-redox processes, including adsorption to organic ligands and potentially biological uptake. These results add to a growing body of evidence for the importance of non-redox transformations in contributing to environmental Cr isotope variations, with implications for the use of chromium isotopes in studies of sedimentary Cr isotope records. In particular, this study is a validation of the potential for sulfide weathering in the Proterozoic to deliver relatively unfractionated Cr isotopes to the ocean, despite rising and sustained high oxygen levels.

54 ENVIRONMENTAL SCIENCES↗

Comparison of chromium poisoning between lanthanum strontium manganite and lanthanum strontium ferrite composite cathodes in solid oxide fuel cells

Degradation mechanisms of chromium poisoning have been extensively investigated for last two decades on various cathode materials for solid oxide fuel cells. While most researchers used half-cell experiments to investigate the effects of chromium impurities, this paper compares the degradation phenomena of LSM-YSZ and LSF-GDC cathodes in full cells under different operating conditions, namely polarized current density and humidity over the cathode. Under cathodic load, performance degradation of LSF-GDC cathode is significantly less than that of LSM-YSZ cathode. Most interestingly, under humidified air condition, LSF-based cell hardly experiences performance degradation while LSM-based cell shows a catastrophic degradation. Cr deposition in LSM-based cells occurs mainly near the electrolyte under both dry and humidified air conditions. In contrast, Cr deposition in LSF-based cell concentrates at the cathode surface under dry air condition, but concentrates both at cathode surface and near electrolyte under humidified air condition. Microstructure analysis reveals Mn-associated Cr deposits in LSM-based cathode, and Sr- and Fe-associated Cr deposits in LSF-based cathode. With the help of distribution of relaxation time analysis, the different electrochemical behaviors of LSM- and LSF-based cells are carefully interpreted. The effects of electrochemical deposition, Sr surface segregation, and humidity on LSM- and LSF-based cathodes are discussed.

25 ENERGY STORAGE↗

Inhibition of Chromium(III) Oxidation through Manganese(IV) Oxide Passivation and Iron(II) Abiotic Reduction

Manganese (Mn) oxides are strong oxidants that are ubiquitous in soils and can oxidize redox-active metals, including chromium (Cr). In soil environments, trivalent chromium (Cr(III)) is a benign, immobile micronutrient, whereas the hexavalent Cr(VI) form is present as a highly mobile, toxic chromate oxyanion. Although many studies have characterized the capacity of Mn(III/IV) oxides to oxidize Cr(III) to toxic Cr(VI), the oxidative capacity of Mn oxides in the presence of potentially passivating soil constituents, specifically reduced soluble iron (Fe(II) aq ), remains unresolved. We hypothesized that chemical processes at redox interfaces, such as diffusion-limited environments within soil aggregates, can lead to decreased Cr(VI) production from Mn oxide-driven oxidation due to passivation by Fe(II) aq . A multichamber diffusion-limited reactor was used to simulate transport at soil redox interfaces and investigate the capacity of poorly crystalline and crystalline Mn oxides to oxidize solid Cr(III) minerals to Cr(VI) in the presence of Fe(II) aq . As predicted, Cr(VI) was produced through the Mn oxide-catalyzed oxidation of Cr(III) at a rate controlled by the solubility of Cr(OH) 3 . However, in the presence of Fe(II) aq , the concentration of aqueous Cr(VI) decreased as a function of the Fe(II) aq concentration, where high concentrations of Fe(II) aq completely inhibited Cr(VI) production, likely through both the passivation of the Mn oxide and the direct reduction of Cr(VI) by Fe(II). At both low (14 μM) and high (100 μM) Fe(II) aq concentrations, the iron oxide minerals hematite (Fe 2 O 3 ) and goethite (α-FeOOH) were associated with the Mn oxides, which can cause surface passivation, a likely role that decreases Cr(III) oxidation. Additionally, the Cr(III) oxidation rate decreased with increasing crystallinity of the Mn oxides whether or not Fe(II) was present.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High temperature gamma radiation-induced chromium redox chemistry via in situ spectroscopic measurements

Chromium ions can make their way into the primary coolant of nuclear power reactors from the corrosion of stainless-steel reactor components, decreasing the material's corrosion resistance and resulting in increased transport of further corrosion products. Despite these potential effects, the radiation-induced redox speciation of chromium ions in aqueous solution is not well understood, especially at the elevated temperatures experienced by reactor coolants. Here, in the present work, we report new experimental results demonstrating that in aerated aqueous solution, the radiolytic oxidation of Cr(III) to Cr(VI) occurs at pH 4, while the reduction of Cr(VI) to Cr(III) occurs at pH 2. The oxidation of Cr(III) is primarily attributed to the reaction of the hydroxyl radical (˙OH) with the Cr(OH) 2+ species, while the reduction of Cr(VI) is attributed to reactions involving the hydrated electron (e aq - ) and hydrogen atom (H˙). Additionally, the steady-state equilibrium yield of Cr(VI) from the gamma irradiation of pH 4 Cr(III) solutions decreased with increasing temperature (over a range of 37–195 °C). This observation indicates that the activation energy of the Cr(VI) reduction reactions is higher than that for the Cr(III) oxidation reactions, such that it becomes relatively more favorable at higher temperatures. Overall, these data are important for the development of complementary multiscale models for the prediction of metal ion speciation in high temperature radiation environments.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Chromium and Vanadium Incorporation in Sulfate-Containing Sodium Aluminoborosilicate Glass

In the composition space for Hanford low-activity nuclear waste glass, the waste loading of some formulations is limited by poor incorporation of sulfate. In particular, certain elements identified in previous studies tend to raise or lower sulfate solubility in borosilicate glass. The aim of the current study is to understand how vanadium and chromium each affect a sulfate-containing sodium aluminoborosilicate glass structure. Glass transition temperature, mass density, visible absorption, and Raman scattering were measured to investigate changes in the glass structure. Both Cr6+ (CrO42-) and Cr3+ were found in the chromium-containing glasses while vanadium primarily existed in the 5+ oxidation state in the vanadium-containing glasses. Electron probe microanalysis determined elemental compositions to assess retention of components. Increasing Cr2O3 caused saturation of Cr concentration within the glass and formation of crystalline eskolaite (Cr2O3). On the other hand, all the targeted V was incorporated into the glass. A fraction of batched S was not incorporated in any glass, presumably due to volatilization during melting. Apparently, the details of incorporation of Cr, and to an extent V, are different depending on whether sulfur is added as in this study or in oversaturated conditions as described in the literature, where Cr partitions to a sulfate-containing salt phase.

Borosilicate glass, Waste Glass, vanadium chemistr↗

Chromium Poisoning ERMINE Model Data

This is the data from the paper "Systematic and Predictive Trends to Chromium Poisoning in Solid Oxide Fuel Cell Cathodes" by Hokon Kim et al., appearing in the Journal of Power Sources. The files here are the microstructures, mesh files, and outputs from the ERMINE finite element model of chromium poisoning in SOFC cathodes. Further description can be found in Readme.rtf and in the paper..

Chromium,SOFC↗