Search NASA⌕ Search

SEARCH · Search NASA

Results for “cold injection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Analysis of Probe Surveys Conducted in the 10-MW TP3 Arc-Jet Facility 15-Inch Nozzle Flow

Computational simulations and analysis of flow characterization tests in a high enthalpy arc-jet facility at NASA Ames Research Center are reported. These tests were conducted in the 10-MW TP3 facility 15-inch conical nozzle, and pitot pressure and heat flux probes are used to survey test flow downstream of the nozzle exit. Two 1.59-cm (0.625 in) diameter hemisphere probes were used: one with a stagnation-point pressure port, the other with a Gardon heat flux gage. Calibration data were also obtained using 10.16-cm iso-q and 20.32-cm flat-faced slug calorimeters. Experimental surveys of arc-jet test flow with pitot pressure and heat flux probes were obtained at eight arc-heater conditions, covering wide ranges in arc current (316–1756 A) and mass flow rate (32–500 g/s, without any cold-gas injection at the arc-heater plenum) and providing assessment of the flow uniformity in the facility. The present analysis comprises computational fluid dynamics simulations of the nonequilibrium flowfield in the facility nozzle and test box, including the models tested. These simulations take into account non-uniform total enthalpy and mass flux profiles at the nozzle inlet as well as the expansion waves emanating from the nozzle exit and their effects on the model flowfields. Comparisons of computations with the experimental measurements are presented, showing reasonably good agreement. The probe survey data and accompanying analysis show that the test flow in the TP3 15-inch nozzle is highly non-uniform at most conditions, and the extent of flow non-uniformity depends on arc current and mass flow rate.

Arc-jets↗

Analysis of Probe Surveys Conducted in the 10-MW TP3 Arc-Jet Facility 15-Inch Nozzle Flow

Computational simulations and analysis of flow characterization tests in a high enthalpy arc-jet facility at NASA Ames Research Center are reported. These tests were conducted in the 10-MW TP3 facility 15-inch conical nozzle, and pitot pressure and heat flux probes are used to survey test flow downstream of the nozzle exit. Two 1.59-cm (0.625 in) diameter hemisphere probes were used: one with a stagnation-point pressure port, the other with a Gardon heat flux gage. Calibration data were also obtained using 20.32-cm flat-faced slug calorimeters. Experimental surveys of arc-jet test flow with pitot pressure and heat flux probes were obtained at eight arc-heater conditions, covering wide ranges in arc current (316–1756 A) and mass flow rate (32–500 g/s, without any cold-gas injection at the arc-heater plenum) and providing assessment of the flow uniformity in the facility. The present analysis comprises computational fluid dynamics simulations of the nonequilibrium flowfield in the facility nozzle and test box, including the models tested. These simulations take into account non-uniform total enthalpy and mass flux profiles at the nozzle inlet as well as the expansion waves emanating from the nozzle exit and their effects on the model flowfields. Comparisons of computations with the experimental measurements are presented, showing reasonably good agreement. The probe survey data and accompanying analysis show that the test flow in the TP3 15-inch nozzle is highly non-uniform at most conditions, and the extent of flow non-uniformity depends on arc current and mass flow rate.

Arc-jets↗

The EGS Collab Project: Learnings from Experiment 1

The primary objective of the EGS Collab Project sponsored by DOE is to increase the understanding needed to efficiently implement enhanced geothermal systems (EGS). One goal of the EGS Collab project is to create a collaborative research environment in which to study stimulation of crystalline rock at the 10 meter scale. Key to this effort is the collection of high quality data to allow comparison to numerical coupled process models in an effort to build confidence in the codes and modeling techniques used. In response to this, the EGS Collab team has created an underground test bed at the Sanford Underground Research Facility (SURF) in Lead SD at a depth of approximately 1.5 km to examine hydraulic fracturing (Experiment 1). We are currently designing a second test bed aimed at investigating shear stimulation (Experiment 2). At the Experiment 1 location, we have characterized our host rock using laboratory testing and numerous field-based geophysical and geological techniques, and created a well-instrumented test bed to allow us to carefully monitor stimulation events and flow tests. In addition to the installed geophysical sensors, we have used tracer tests, differences in the ambient microbial communities at flow collection locations, and cold water injection to inform us about dynamic flow pathways. In Experiment 1, we have hydraulically stimulated the host rock in a number times at several locations in one well, creating new fractures that connect to existing fractures between the injection and production boreholes. We have performed long-term ambient and chilled water injection tests as an analog to EGS, and have monitored system changes resulting from these water injections through geophysical monitoring, flow and pressure measurements, tracer tests, and microbiology. Here, we summarize the tests performed, issues identified including poroelastic and thermoelastic effects, Joule-Thomson effects, restarting effects, indications of flow channeling, and the primary learnings from Experiment 1.

Enhanced Geothermal Systems, EGS Collab, stimulati↗

GeoThermalCloud for EGS – An Open-source, User-friendly, Scalable AI Workflow for Modeling Enhanced Geothermal Systems

Enhanced Geothermal Systems (EGS) offer a vast potential to expand the use of geothermal energy. Heat is extracted from this engineered system by injecting relatively cold water into subsurface fractures, which are in contact with hot dry rock, and brought back to surface through production wells. Creating EGS requires improving the natural permeability of hot crystalline rocks. In this short conference paper, we present a reproducible workflow for modeling EGS. Our workflow called the GeoThermalCloud (GTC) for EGS, leverages recent advances in machine learning, deep learning, and high-performance computing. This GTC framework is currently being made open-source, user-friendly, and reproducible through python scripts as well as Google Colab/Jupyter Notebooks. This GTC for EGS modeling scripts are made available at https://github.com/SmartTensors/GeoThermalCloud.jl/tree/master/EGS and will constantly be updated to cater for geothermal community. Current GTC framework provides scripts to train deep learning (DL) models for techno-economics and data worth analysis. The Geothermal Design Tool (https://github.com/GeoDesignTool/GeoDT.git), a fast and simplified multi-physics solver, is used to develop a database for training DL models. This short paper provides details on the scripts to curate, process, and train DL models. The scripts can easily be modified to train on databases generated by other popular open-source simulators such as PFLOTRAN, STOMP, TOUGH, and GEOSX or commercial software such as ResFrac and COMSOL.

15 GEOTHERMAL ENERGY↗

High‑performance cold‑climate heat pump using tandem compressors with and without vapor injection: Laboratory investigation and field demonstration

Cold‑climate air‑source heat pumps must maintain heating capacity and stable operation at low ambient temperatures for residential applications. This study adapts tandem single-speed compressors—proven in commercial systems —for residential CCHPs, integrating VI and validating performance across laboratory and extreme field conditions to achieve cold-climate targets. That is to achieve ≥75% of the rated heating capacity at −25.0 °C relative to 8.3 °C and heating coefficient of performance (COP) greater than 4.0 at 8.3 °C. Laboratory testing confirmed that both configurations met these targets while operating within acceptable discharge‑temperature limits. Relative to the non‑VI configuration, the VI system provided up to 15% higher heating capacity and up to 9% higher heating COP under identical conditions, yielding a 5.6–9.1% increase in heating seasonal performance factor (HSPF). Field tests in Ohio and Alaska, with minimum outdoor temperatures of −25.0 °C and −34.0 °C, respectively, showed stable operation, minimal supplemental heating (<3.2%), low defrost penalties, and consistent output. Tandem‑compressor architectures proves promising for cold-climate residential heating.

Hu, Yifeng [ORNL] (ORCID:0000000242875185)↗

Assessment of impinged flame structure in high-pressure direct diesel injection

Spray impingement often occurs during cold-start in direct-injection diesel engines, affecting the subsequent combustion process by altering the local flow condition. This work has investigated the impinged flame structure by examining local expansion distance and planar curvature of the boundary in details. The experiments were carried out in a constant volume combustion chamber. The injection pressure and ambient density were varied from 120 to 180 MPa and 14.8 to 30.0 kg/m 3 under non-vaporizing conditions, respectively. For reacting conditions, the injection pressure and ambient density were fixed at 150 MPa and 22.8 kg/m 3 but with different ambient temperatures from 800 to 1000 K. Unlike orthogonal spray impingement, the profile of expansion distance along the radial direction at the 60° impinging angle is non-uniform but the profile is comparable between the non-vaporizing and reacting conditions under the same injection pressure and ambient density. With the help of Intensity-aXial-Time method, the most intensive soot luminosity region and Mie scattering intensity region are identified and the region has been found to be along the impinged spray axial direction. Outmost boundary of an impinged flame is found to have wrinkles attributed to air entrainment. The temporal level of flame wrinkles is higher in reacting conditions than in non-vaporizing conditions. The scatter distribution of the boundary curvature and near-field soot formation illustrates an inverted “S” shape correlation with time. High flame luminosity is found to be formed in concave regions while less soot is formed in convex regions. This inverted S-shape is a new finding of the state relationship at the solid–liquid–gas impinged flame propagation. Finally, heat flux measurement through the plate is examined.

Engineering↗

Low-energy, high-current, ion source with cold electron emitter

An ion source based on a two-stage discharge with electron injection from a cold emitter is presented. The first stage is the emitter itself, and the second stage provides acceleration of injected electrons for gas ionization and formation of ion flow (<20 eV, 5 A dc). The ion accelerating system is gridless; acceleration is accomplished by an electric field in the discharge plasma within an axially symmetric, diverging, magnetic field. The hollow cathode electron emitter utilizes an arc discharge with cathode spots hidden inside the cathode cavity. Selection of the appropriate emitter material provides a very low erosion rate and long lifetime.

43 PARTICLE ACCELERATORS↗

Finalize field testing of cold climate heat pump (CCHP) based on tandem vapor injection compressors

This report describes the system diagram and control algorithm of a prototype air-source cold climate heat pump (CCHP) using tandem vapor injection (VI) compressors. The prototype was installed in Fairbanks, Alaska and underwent field testing starting in 09/2016. The field testing results of the past six months, including compressor run time fractions, measured COPs and heating capacities, etc., are presented as a function of the ambient temperature. Two lessons learned are also reported.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of scramjet combustor performance using cold nonreactive mixing tests

Results of cold supersonic ducted mixing tests are presented and compared with results of hot mixing and combustion tests obtained using the same apparatus. Two strut injectors are evaluated, one with injectors parallel to the free-stream direction and one with perpendicular injectors. Detailed flow surveys are used to determine the degree of mixing accomplished in the cold flow tests. In the hot flow tests, the amount of mixing and reaction is inferred from survey data and comparison of wall static pressures with one-dimensional flow calculations. These comparisons show that cold mixing results can be used to predict combustion results. In some cases, such as the normal injection strut tested, cold mixing efficiency and combustion efficiency are identical. In other cases, transport models developed from cold flow results can be applied to predict the effects of higher temperature mixing and reaction. Cold flow surveys are also used to determine detailed flow characteristics not readily measured in hot flows.

Mcclinton, C. R.↗

An experimental study of turbine vane heat transfer with leading edge and downstream film cooling

This paper presents the effects of downstream film cooling, with and without leading edge showerhead film cooling, on turbine-vane external heat transfer. Steady-state experimental measurements were made in a three-vane linear two-dimensional cascade. The principal independent parameters were maintained over ranges consistent with actual engine conditions. The test matrix was structured to provide an assessment of the independent influence of parameters of interest, namely, exit Mach number, exit Reynolds number, coolant-to-gas temperature ratio, and coolant-to-gas pressure ratio. The data obtained indicate that considerable cooling benefits can be achieved by utilizing downstream film cooling. The downstream film cooling process was shown to be a complex interaction of two competing mechanisms. The thermal dilution effect, associated with the injection of relatively cold fluid, results in a decrease in the heat transfer to the airfoil. Conversely, the turbulence augmentation, produced by the injection process, results in increased heat transfer to the airfoil.

Nirmalan, V.↗

Cavity morphology in a Ni based superalloy under heavy ion irradiation with hot pre-injected helium. II

In the current investigation, TEM in-situ heavy ion (1 MeV Kr{sup 2+}) irradiation with helium pre-injected at elevated temperature (400 °C) was conducted to simulate in-reactor neutron irradiation induced damage in CANDU spacer material Inconel X-750, in an effort to understand the effects of helium on irradiation induced cavity microstructures. Three different quantities of helium, 400 appm, 1000 appm, and 5000 appm, were pre-injected directly into TEM foils at 400 °C. The samples containing helium were then irradiated in-situ with 1 MeV Kr{sup 2+} at 400 °C to a final dose of 5.4 dpa (displacement per atom). Cavities were formed from the helium injection solely and the cavity density and size increased with increasing helium dosage. In contrast to previous heavy ion irradiations with cold pre-injected helium, heterogeneous nucleation of cavities was observed. During the ensuing heavy ion irradiation, dynamical observation showed noticeable size increase in cavities which nucleated close to the grain boundaries. A “bubble-void” transformation was observed after Kr{sup 2+} irradiation to high dose (5.4 dpa) in samples containing 1000 appm and 5000 appm helium. Cavity distribution was found to be consistent with in-reactor neutron irradiation induced cavity microstructures. This implies that the distribution of helium is greatly dependent on the injection temperature, and helium pre-injection at high temperature is preferred for simulating the migration of the transmutation produced helium.

36 MATERIALS SCIENCE↗

Analysis of a six-component, flow-through, strain-gage, force balance used for hypersonic wind tunnel models with scramjet exhaust flow simulation

The thermal effects of simulant gas injection and aerodynamic heating at the model's surface on the measurements of a non-watercooled, flow through balance were investigated. A stainless steel model of a hypersonic air breathing propulsion cruise missile concept (HAPCM-50) was used to evaluate this balance. The tests were conducted in the 20-inch Mach 6 wind tunnel at NASA-Langley. The balance thermal effects were evaluated at freestream Reynolds numbers ranging from .5 to 7 x 10(exp 6) ft and angles of attack between -3.5 to 5 deg at Mach 6. The injection gases considered included cold air, hot air, and a mixture of 50 percent Argon and 50 percent Freon-12. The stagnation temperatures of the cold air, hot air, and Ar-Fr(12) reached 111, 214, and 283 F, respectively within the balance. A bakelite sleeve was inserted into the inner tube of the balance to minimize the thermal effects of these injection gases. Throughout the tests, the normal force, side force, yaw moment, roll moment, and pitching moment balance measurements were unaffected by the balance thermal effects of the injection gases and the wind tunnel flow. However, the axial force (AF) measurement was significantly affected by balance heating. The average zero shifts in the AF measurements were 1.9, 3.8, and 5.9 percent for cold air, hot air, and Ar-Fr(12) injection, respectively. The AF measurements decreased throughout these tests which lasted from 70 to 110 seconds. During the cold air injection tests, the AF measurements were accurate up to at least ten seconds after the model was injected into the wind tunnel test section. For the hot air and Ar-Fr(12) tests, the AF measurements were accurate up to at least five seconds after model injection.

Kniskern, Marc W.↗

Next Generation Muon g-2 Experiments

I report on the progress of two new muon anomalous magnetic moment experiments, which are in advanced design and construction phases. The goal of Fermilab E989 is to reduce the experimental uncertainty of $a_\mu$ from Brookhaven E821 by a factor of 4; that is, $\delta a_\mu \sim 16 \times 10^{-11}$, a relative uncertainty of 140~ppb. The method follows the same magic-momentum storage ring concept used at BNL, and pioneered previously at CERN, but muon beam preparation, storage ring internal hardware, field measuring equipment, and detector and electronics systems are all new or upgraded significantly. In contrast, J-PARC E34 will employ a novel approach based on injection of an ultra-cold, low-energy, muon beam injected into a small, but highly uniform magnet. Only a small magnetic focusing field is needed to maintain storage, which distinguishes it from CERN, BNL and Fermilab. E34 aims to roughly match the previous BNL precision in their Phase~1 installation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Theoretical analysis of a refrigerant injection-enhanced air source heat pump with thermal energy storage for extended cold-climate and defrosting operations

This study investigates a conceptual refrigerant injection-enhanced air source heat pump with integrated thermal energy storage (ITES-ASHP) that combines two-phase flash tank injection with phase change material (PCM) thermal energy storage (TES) to extend cold-climate operation and maintain indoor heating during defrost. A steady-state, mode-based thermodynamic cycle model is developed to evaluate heating and defrosting modes with and without refrigerant injection and TES integration over an outdoor temperature range of 8 to −25 °C. The framework is applied to refrigerants R-290, R-454B, R-410 A, and R-32. A parametric study is conducted for an 18-kW system rated for an outdoor temperature of 8 °C, with the compressor frequency scheduled to 150 Hz. The optimal PCM phase-change temperature is identified as 20 °C for R-290, R-454B, and R-410 A, and 15 °C for R-32. At the design condition of −25 °C outdoor temperature, the proposed concept achieves a combined COP of 2.22 for R-290, corresponding to a 60% increase relative to the theoretical single-stage baseline for combined heating and defrosting operation. Safety screening based on compressor discharge temperature (≤ 120 °C) and injection quality (≥ 0.65), together with performance evaluation, indicates that R-290 is the most suitable candidate, followed by R-410 A and R-454B. Under the assumptions and constraints used here, R-32 is found to be less suitable due to excessive discharge temperatures and a higher risk of wet compression.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An analysis of Potential Benefits of Adding Diurnal Thermal Storage in Geothermal Heat Pump Systems

Geothermal heat pumps (GHP) are highly efficient for space heating and cooling, utilizing the subsurface of the ground as seasonal energy storage through borehole heat exchangers (i.e., heat stored in summer is used to provide heating in winter, and cold stored in winter is used to provide cooling in summer). On the other hand, diurnal thermal energy storage can actively be charged and discharged for load shifting. Conventional thermal energy storage uses tanks filled with thermal storage media (such as phase change materials) and heat exchangers. It occupies building floor space or land areas outside the building, which may not be available especially in residential buildings. This paper will introduce a novel configuration that can utilize existing GHP system for both diurnal and seasonal thermal storage. This system can actively charge the ground on daily basis by injecting heat or cold in borehole heat exchangers. A simulation model was created for the novel configuration. Computer simulations were conducted using the model for the new GHP system serving a typical single-family house in three U.S. cities representing hot, warm, and cold climates. Based on simulation results, the potential benefits of load shifting and downsize of the expensive ground heat exchangers used by the GHP system were assessed.

Anees, Fady [ORNL]↗

Effect of Split-Injection Strategies on Engine Performance and Emissions under Cold-Start Operation

The recently concluded partnership for advancing combustion engines (PACE) was a US Department of Energy consortium involving multiple national laboratories focused on addressing key efficiency and emission barriers in light-duty engines. Generation of detailed experimental data and modeling capabilities to understand and predict cold-start behavior was a major pillar in this program. Cold-start, as defined by the time between first engine crank and three-way catalyst light-off, is responsible for a large percentage of NOx, unburned hydrocarbon, and particulate matter emissions in light-duty engines. Minimizing emissions during cold-start is a trade-off between achieving faster three-way catalyst light-off, and engine out emissions during that period. In this study, engine performance, emissions, and catalyst warmup potential were monitored while the engine was operated using a single direct injection (baseline case) as well as a two-way-equal-split direct injection strategy. These injection strategies were analyzed at a range of cold-start-operation relevant retarded spark timings of up to 25 degrees after top dead center of firing (dATDCf). A stoichiometric 2-bar NIMEP steady-state condition was used for all cases to simulate cold-start operation. Significant improvement in engine stability was observed with the two-way-split injection strategy at the retarded spark timings allowing for up to 2.5x increase in exhaust heat rate when engine operation is stability constrained. Similar fuel-loss-to-oil trends with exhaust heat rate were observed for both single and two-way-split injection strategies. However, the two-way split injection was observed to produce higher NOx emissions per unit exhaust heat rate. A single data point run with three-way-split direct injection at a very retarded spark-timing of 30 dATDCf pointed to further improvements in engine stability and reduction in fuel-loss-to-oil as compared to single injection strategy. Engine stability decreased as spark timing was initially retarded with a single injection but was observed to plateau and stabilize beyond spark timing of 10 dATDCf. Finally, for the two-way-split-injection strategy, retarding the start of injection (SOI) timing of the second injection led to a decrease in engine stability as well as an increase in soot emissions.

42 ENGINEERING↗

A coupled thermo-hydro-mechanical model for simulating leakoff-dominated hydraulic fracturing with application to geologic carbon storage

A potential risk of injecting CO2 into storage reservoirs with marginal permeability (≲ 10 mD (1 mD = 10 –15 m 2 )) is that commercial injection rates could induce fracturing of the reservoir and/or the caprock. Such fracturing is essentially fluid-driven fracturing in the leakoff-dominated regime. Recent studies suggested that fracturing, if contained within the lower portion of the caprock complex, could substantially improve the injectivity without compromising the overall seal integrity. Modeling this phenomenon entails complex coupled interactions among the fluids, the fracture, the reservoir, and the caprock. Here, we develop a simple method to capture all these interplays in high fidelity by sequentially coupling a hydraulic fracturing module with a coupled thermal-hydrological-mechanical (THM) model for nonisothermal multiphase flow. The model was made numerically tractable by taking advantage of self-stabilizing features of leakoff-dominated fracturing. The model is validated against the PKN solution in the leakoff-dominated regime. Moreover, we employ the model to study thermo-poromechanical responses of a fluid-driven fracture in a field-scale carbon storage reservoir that is loosely based on the In Salah project's Krechba reservoir. The model reveals complex yet intriguing behaviors of the reservoir-caprock-fluid system with fracturing induced by cold CO 2 injection. We also study the effects of the in situ stress contrast between the reservoir and caprock and thermal contraction on the vertical containment of the fracture. The proposed model proves effective in simulating practical problems on length and time scales relevant to geological carbon storage.

58 GEOSCIENCES↗

Demonstration of CFD to support the coupled analysis of a reactor pressure vessel subjected to pressurized thermal shock

The structural components that comprise nuclear reactors and their supporting structures are subjected to harsh operating environments that can challenge their integrity, especially after exposure for extended duration or under accident condition. As one of the most significant components of a reactor, the Reactor Pressure Vessel (RPV) is exposed to an aggressive environment during the operation time (e.g. more than 40 years). Aging degradation mechanisms (e.g. thermo-fatigue) could grow initial defects up to a critical size, increasing the susceptibility to failure in the RPV. The conventional methods are mostly based on simple crack and structure geometries. Very limited studies consider the real conditions of the RPV subjected to a thermal shock due to a Loss of Coolant Accident (LOCA). During a LOCA event, the most severe conditions take place when the emergency core cooling (ECC) water is injected inside the cold legs filled initially with hotter water and/or steam. The rapid cooling of the down-comer and the internal RPV surface followed probably by re-pressurization of the RPV causes large temperature gradients and variation of pressure which induces thermal-mechanical stresses. In order to develop the model for integrity assessment of a reactor pressure vessel (RPV) subjected to pressurized thermal shock (PTS), a multi-physics simulation, which includes the thermo-hydraulic, thermo-mechanical and fracture mechanics analyses is necessary. The prediction of the temperature field is achieved by using computational fluid dynamics (CFD) simulation. In this report, a demonstration CFD standalone simulation is performed to support coupled analysis for Reactor Pressure Vessel (RPV) subjected to Pressurized Thermal Shock (PTS). The study use a simplified computational domain to represents a real RPV. The purpose of the study is to demonstrate the transient temperature response of RPV to ECC injection. The CFD model is built in a robust and efficient way for further coupled calculation. The next steps of this work, including the coupled thermal and tensor mechanics capabilities using Cardinal are expected to be complete by the end of FY21 for the demo problem. After this, into FY22, the capability will be demonstrated for a realistic RPV.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗