Search NASA⌕ Search

SEARCH · Search NASA

Results for “cold temperatures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Alternate method for achieving temperature control in the -160 to +90 Celcius range

A single-pass method for accurate and precise temperature control in the -160 to +90 C range is discussed. The method exhibited minimal set-point overshoot during temperature transitions. Control to +/-2 C with transitions between set-points of 7 C per minute were achieved. The method uses commercially available temperature controllers and a gaseous nitrogen/liquid nitrogen mixer to dampen the amplitude of cold temperature spikes caused by liquid nitrogen pulsing.

Johnson, Kenneth R.↗

Noctilucent cloud formation and the effects of water vapor variability on temperatures in the middle atmosphere

To investigate the occurrence of low temperatures and the formation of noctilucent clouds in the summer mesosphere, a one-dimensional time-dependent photochemical-thermal numerical model of the atmosphere between 50 and 120 km has been constructed. The model self-consistently solves the coupled photochemical and thermal equations as perturbation equations from a reference state assumed to be in equilibrium and is used to consider the effect of variability in water vapor in the lower mesosphere on the temperature in the region of noctilucent cloud formation. It is found that change in water vapor from an equilibrium value of 5 ppm at 50 km to a value of 10 ppm, a variation consistent with observations, can produce a roughly 15 K drop in temperature at 82 km. It is suggested that this process may produce weeks of cold temperatures and influence noctilucent cloud formation.

Mckay, C. P.↗

Profiles of temperature and density based on extremes at 5, 10, 20, 30 and 40 km

Information on the vertical distribution of expected extremes of temperature and density are required for the design and operation of systems traversing the atmosphere. Such data are particularly important at altitudes from the surface to approximately 80 km for developing all types of airborne vehicles ranging from helicopters and airplanes to sophisticated aerospace systems. Vertical profiles of temperature and density have been developed based on 1- and 10-percent hot and cold temperatures and 1- and 10- percent high and low densities occurring during the most severe month at the worst locations for which reliable upper-air data are available. The model profiles, from the surface to 80 km, are based on extremes that occur at 5, 10, 20, 30, and 40 km. There are 20 profiles for extreme temperatures (5 levels by 4 percentiles) that include associated densities, and 20 analogous profiles for extreme densities including associated temperatures. Consequently, a set of realistic profiles (rather than envelopes) of temperature and density, associated with extremes at each of 5 specified levels in the troposphere and stratosphere, are now available for altitudes up to 80 km.

Kantor, A. J.↗

Tectonic plates, D (double prime) thermal structure, and the nature of mantle plumes

It is proposed that subducting tectonic plates can affect the nature of thermal mantle plumes by determining the temperature drop across a plume source layer. The temperature drop affects source layer stability and the morphology of plumes emitted from it. Numerical models are presented to demonstrate how introduction of platelike behavior in a convecting temperature dependent medium, driven by a combination of internal and basal heating, can increase the temperature drop across the lower boundary layer. The temperature drop increases dramatically following introduction of platelike behavior due to formation of a cold temperature inversion above the lower boundary layer. This thermal inversion, induced by deposition of upper boundary layer material to the system base, decays in time, but the temperature drop across the lower boundary layer always remains considerably higher than in models lacking platelike behavior. On the basis of model-inferred boundary layer temperature drops and previous studies of plume dynamics, we argue that generally accepted notions as to the nature of mantle plumes on Earth may hinge on the presence of plates. The implication for Mars and Venus, planets apparently lacking plate tectonics, is that mantle plumes of these planets may differ morphologically from those of Earth. A corollary model-based argument is that as a result of slab-induced thermal inversions above the core mantle boundary the lower most mantle may be subadiabatic, on average (in space and time), if major plate reorganization timescales are less than those acquired to diffuse newly deposited slab material.

Lenardic, A.↗

Effects of Temperature on the Performance and Stability of Recent COTS Silicon Oscillators

Silicon oscillators have lately emerged to serve as potential replacement for crystal and ceramic resonators to provide timing and clock signals in electronic systems. These semiconductor-based devices, including those that are based on MEMS technology, are reported to be resistant to vibration and shock (an important criteria for systems to be deployed in space), immune to EMI, consume very low current, require few or no external components, and cover a wide range of frequency for analog and digital circuits. In this work, the performance of five recently-developed COTS silicon oscillator chips from different manufacturers was determined within a temperature range that extended beyond the individual specified range of operation. In addition, restart capability at extreme temperatures, i.e. power switched on while the device was soaking at extreme (hot or cold) temperature, and the effects of thermal cycling under a wide temperature range on the operation of these silicon oscillators were also investigated. Performance characterization of each oscillator was obtained in terms of its output frequency, duty cycle, rise and fall times, and supply current at specific test temperatures. The five different oscillators tested operated beyond their specified temperature region, with some displaying excellent stability throughout the whole test temperature range. Others experienced some instability at certain temperature test points as evidenced by fluctuation in the output frequency. Recovery from temperature-induced changes took place when excessive temperatures were removed. It should also be pointed out that all oscillators were able to restart at the extreme test temperatures and to withstand the limited thermal cycling without undergoing any significant changes in their characteristics. In addition, no physical damage was observed in the packaging material of any of these silicon oscillators due to extreme temperature exposure and thermal cycling. It is recommended that additional and more comprehensive testing under long term cycling be carried out to fully establish the reliability of these devices and to determine their suitability for use in space exploration missions under extreme temperature conditions.

Patterson, Richard L.↗

The Teton-Yellowstone Tornado of 21 July 1987

The Teton-Yellowstone Tornado, rated F4, crossed the Continental Divide at 3070 m, leaving behind a damage swath 39.2-km long and 2.5-km wide. A detailed damage analysis by using stereo-pair and color photos revealed the existence of four spinup swirl marks and 72 microburst outflows inside the damage area. The tornado was spawned by a mesocyclone that formed at the intersection of a mesohigh boundary and a warm front. The parent cloud of the tornado, tracked on eight infrared-temperature maps from GOES East and West, moved at 25 m s-1 and the number of cold temperature pixels below -60 C reached a distinct peak during the tornado time. Identified and tracked also are two warm spots enclosed inside the cold anvil cloud. On the basis of their identity and movement, an attempt was made to explain the cause of these spots as being the stratospheric cirrus clouds.

Fujita, T. Theodore↗

Prototype Motor Controllers Demonstrated for the James Webb Space Telescope Cryogenic Environment

NASA is in the process of designing the James Webb Space Telescope. This telescope will investigate images of objects in deep space (stars, galaxies, etc.) by using light in the infrared region of the light spectrum. To make such observations, the telescope must have light sensors that operate at very cold temperatures, near absolute zero. To achieve this low-temperature tolerance, designers must place the light sensors behind a Sun shield that will prevent sunlight, and its heat, from reaching the sensors. In this cold region inside the telescope, electric motors and some motor controls must operate at temperatures near 40 K (40 degrees above absolute zero). These motors will be used to position light filters needed by the telescope. There are motors that operate at the low temperatures, but there is little technology for low-temperature motor-control electronics. The drawing shows how the motors and their controls are positioned behind the Sun shield. Simplified version of the layout of the motor and control electronics that are located, as dictated by mission requirements, in the cold zone of the James Webb Space Telescope. A Sun shield provides protection and isolation of these electronics from the heat of the rays of the sun. Room temperature compoenets (control computer, motor select command, motor phase drive, power supply, parallel to serial, and sun shield) as well as 40-kelvin components (motor select, serial to parallel, and motors) are shown. The Low Temperature Electronics Group at the NASA Glenn Research Center has been working to develop motor control electronics that will operate at a temperature of 40 K. The group conducted tests to determine which electronic components will operate at such very low temperatures. Then, components that were determined to operate successfully at the low temperatures were used to design low-temperature motor-controller circuits. A prototype motor controller circuit was built, evaluated, and demonstrated to operate at 70 K. Next, Glenn researchers plan to determine circuit performance at much colder temperatures--down to 40 K. This low-temperature program was supported by the James Webb Space Telescope Electrical Systems Design Group at the NASA Goddard Space Flight Center and by the NASA Electronic Parts and Packaging Program at NASA Headquarters and the Jet Propulsion Laboratory.

Patterson, Richard L.↗

Climatic Implications of the Observed Temperature Dependence of the Liquid Water Path of Low Clouds

The uncertainty in the global climate sensitivity to an equilibrium doubling of carbon dioxide is often stated to be 1.5-4.5 K, largely due to uncertainties in cloud feedbacks. The lower end of this range is based on the assumption or prediction in some GCMs that cloud liquid water behaves adiabatically, thus implying that cloud optical thickness will increase in a warming climate if the physical thickness of clouds is invariant. Satellite observations of low-level cloud optical thickness and liquid water path have challenged this assumption, however, at low and middle latitudes. We attempt to explain the satellite results using four years of surface remote sensing data from the Atmospheric Radiation Measurements (ARM) Cloud And Radiation Testbed (CART) site in the Southern Great Plains. We find that low cloud liquid water path is insensitive to temperature in winter but strongly decreases with temperature in summer. The latter occurs because surface relative humidity decreases with warming, causing cloud base to rise and clouds to geometrically thin. Meanwhile, inferred liquid water contents hardly vary with temperature, suggesting entrainment depletion. Physically, the temperature dependence appears to represent a transition from higher probabilities of stratified boundary layers at cold temperatures to a higher incidence of convective boundary layers at warm temperatures. The combination of our results and the earlier satellite findings imply that the minimum climate sensitivity should be revised upward from 1.5 K.

DelGenio, Anthony↗

Observations of the Upper Tropospheric Water Vapor Feedback in UARS MLS and HALOE Data

One of the biggest uncertainties in climate science today concerns the water vapor feedback. Most GCMs hold relative humidity fixed as the climate changes, which provides a strong positive feedback to warming due from anthropogenic greenhouse gas emissions. Some in the community, on the other hand, have speculated that tropospheric specific humidity will remain fixed as the climate changes. Observational studies have attempted to resolve this disagreement, but the results have been inconclusive, and few of the studies have focused on the upper troposphere (UT). This is a significant oversight: the surface temperature is especially sensitive to changes in water vapor in the UT owing to the cold temperatures found there. We present an analysis of UARS MLS and HALOE water vapor measurements at 21 5 hPa. We find strong evidence that the water vapor feedback in the UT is positive, but not as strong as fixed relative humidity scenarios. This suggests that GCMs are overestimating the sensitivity of the climate.

Dessler, A. E.↗

Stratospheric meteorological conditions in the Arctic polar vortex, 1991 to 1992

Stratospheric meteorological conditions during the Airborne Arctic Stratospheric Expedition II (AASE II) presented excellent observational opportunities from Bangor, Maine, because the polar vortex was located over southeastern Canada for significant periods during the 1991-1992 winter. Temperature analyses showed that nitric acid trihydrates (NAT temperatures below 195 K) should have formed over small regions in early December. The temperatures in the polar vortex warmed beyond NAT temperatures by late January (earlier than normal). Perturbed chemistry was found to be associated with these cold temperatures.

Newman, P.↗

Predicting Operational Performance of xEMU Boot at Lunar South Pole Temperatures using Thermal Desktop ®

The spacesuit boots that will be used on Artemis lunar south pole surface missions will be exposed to extremely cold temperatures (down to ~50 K). To assess the performance of the government’s Exploration Extravehicular Mobility Unit (xEMU) lunar boot in these permanently shadowed regions, testing was performed at the Jet Propulsion Lab (JPL) in the Cryogenic Ice Transfer, Acquisition Development, and Excavation Laboratory (CITADEL) thermal vacuum (TVAC) chamber. This paper documents the data analysis, thermal boot model correlation, and operational predictions conducted using data from the xEMU CITADEL TVAC test. Expected thermal conductances within the boot and between the boot and environment were calculated from test data, which was then used as an initial guess for conductances within a Thermal Desktop (TD) model. Correlation of the TD model using the internal SOLVER feature was performed across 10 different test points which varied external temperature, internal boot ventilation flowrate, and contact pressure. Operational performance at the lunar south pole was then predicted using results from the correlated model. While the predictions provide evidence for acceptable performance of the boots at the 100K environment test point, there is still substantial uncertainty in performance, especially at the 48K test point. This uncertainty is due in part to testing limitations such as contacting the foot to a hard metal plate rather than granular regolith, and model limitations such as the lack of a realistic foot model. These limitations and their impacts are addressed in detail in this paper. The results of this test series and model correlation underscore the importance of additional improved testing and modeling for characterizing the expected thermal resistance between the outside of the boot and the lunar surface.

Spacesuit↗

Thermal Assessment of Landsat-7 ETM+ Radiative Cooler in Instrument and Spacecraft Thermal Vacuum Tests and in Flight

During the radiative cooler cool-down phase of the Landsat-7 Enhanced Thematic Mapper Plus (ETM+) instrument thermal vacuum test #3, the coldest temperature that the Cold Focal Plane Array (CFPA) achieved was 89.5 K. The cold stage/CFPA temperature decreased from 315 K to 89.5 K in 80 hours. In the spacecraft and instrument integrated thermal vacuum test, the cold stage/CFPA temperature decreased from 315 K to 86.9 K in 80 hours, and was still decreasing at a rate of 0.08 K/hr when the cool-down was terminated. The cool-down was faster, and a colder CFPA temperature was obtained. In flight, the cooler cool- down was even faster, and colder. The cold stage/CFPA temperature decreased from 315 K to 89.7 K in 33 hours, and was still decreasing at a rate of 1 K/hr when cool- down was terminated at 89.7 K. The factors that affected the ETM+ cooler cool-down are the radiation heat sink temperature for the cold stage and intermediate stage, parasitic radiation heat load to the cooler, parasitic conduction heat load to the cooler, and cooler outgas time preceding cooler cool-down.

Choi, Michael K.↗

Volatile Analysis by Pyrolysis of Regolith (Vapor) on the Moon using Mass Spectrometry

The identification of lunar resources such as water is a fundamental component of the the NASA Vision for Space Exploration. The Lunar Prospector mission detected high concentrations of hydrogen at the lunar poles that may indicate the presence of water or other volatiles in the lunar regolith [1]. One explanation for the presence of enhanced hydrogen in permanently shadowed crater regions is long term trapping of water-ice delivered by comets, asteroids, and other meteoritic material that have bombarded the Moon over the last 4 billion years [2]. It is also possible that the hydrogen signal at the lunar poles is due to hydrogen implanted by the solar wind which is delayed from diffusing out of the regolith by the cold temperatures [3]. Previous measurements of the lunar atmosphere by the LACE experiment on Apollo 17, suggested the presence of cold trapped vola'tiles that were expelled by solar heating [4]. In situ composition and isotopic analyses of the lunar regolith will be required to establish the abundance, origin, and distribution of water-ice and other volatiles at the lunar poles. Volatile Analysis by Pyrolysis of Regolith (VAPoR) on the Moon using mass spectrometry is one technique that should be considered. The VAPoR pyrolysis-mass spectrometer (pyr-MS) instrument concept study was selected for funding in 2007 by the NASA Lunar Sortie Science Opportunities (LSSO) Program. VAPoR is a miniature version of the Sample Analysis at Mars (SAM) instrument suite currently being developed at NASA Goddard for the 2009 Mars Science Laboratory mission (Fig. 1).

Glavin, D. P.↗

From peak to plummet: impending decline of the warm Arctic-cold continents phenomenon

Abstract This study assesses the projected trajectory of Warm Arctic-Cold Continent (WACC) events in East Asia and North America through large ensemble simulation for the upcoming decades. It analyses the evolution of the geographical boundaries of threshold cold temperatures, revealing a significant northward shift as a sign of global warming’s impact on the southward advancement of Arctic cold air. While validating the intensification of the WACC phenomenon until the 2020 s, echoing earlier studies, the findings indicate a marked decrease beginning in the 2030s. If warming is not curbed, this shift suggests a critical modification in the WACC pattern, prompting a re-evaluation of existing theories and models for extreme winter weather events. The results have major implications, spurring communities impacted by WACC to anticipate future changes and encouraging the climate forecasting community to update conceptual models for improved adaptation and mitigation approaches.

Meteorology & Atmospheric Sciences↗

Kodak AMSD Cryogenic Test Plans

NGST will be an IR based optical system that will operate at cryogenic temperatures. As part of the AMSD program, Kodak must demonstrate the ability of our system to perform at these very cold temperatures. Kodak will discuss the test approach that will be used for cryogenic testing at MSFC's XRCF.

Matthews, Gary↗

A system for model access in tunnels with an unbreathable test medium

In many specialty wind tunnels, test gases other than ambient air are used to meet special testing requirements. A typical example is the use of freon as the test gas to achieve a realistic density ratio between gas and model for exploring flutter stability boundaries. Another example is the use of pressurized air to elevate the stream density and enhance Reynolds number or dynamic pressure simulation. Such specialty tunnels require a system of access o the model which will allow services and changes to the model without exposing personnel to the unnatural and perhaps hostile environment or requiring the venting and purging of the entire tunnel circuit. This paper will describe the plenum and model access systems for the forthcoming U.S. National Transonic facility where gaseous nitrogen (N2) at temperatures between 338 and 78 K and at pressures to 9 bars is used as the test medium. The operation at cold temperatures imposes some additional requirements which make the access systems more difficult to design and time consuming to operate than for conventional wind tunnels.

Howell, R. R.↗

Operation of FPGAs at Extremely Low Temperatures

This paper describes the operation of FPGAs at very low temperatures eg -160(deg)C. Both Actel and Xilinx parts are tested It was found that low temperature operations is not a problem with the parts tested, but there is a problem with powering on an FPGA at cold temperatures.

Field-Programmable Gate Array (FPGA)↗

Microphysical Characteristics of Clouds During the TRMM Field Campaign

Further analysis of the TRMM field campaign data was conducted to examine the growth of precipitation in updraft regions of the TRMM field campaign tropical clouds and to extend the earlier results to cover the whole TRMM data set collected by the University of North Dakota (UND). The results have been submitted for publication. In this paper, composite vertical profiles of liquid water, small particle concentration, and updraft/downdraft magnitudes were presented from each of the campaigns. They exhibited similar peak values for the two TRMM regions of LBA and Kwajalein. Updrafts were found to be favored locations for precipitation embryos in the form of liquid or frozen drizzle-sized droplets. Although liquid water concentrations decreased to undetectable levels between -5 and -18 C in most glaciating updrafts, occasional traces of liquid water were found in updrafts at colder temperatures, probably due to the persistence of liquid drizzle droplets. The updraft magnitudes where the traces of liquid water were observed at cold temperatures do not appear to be stronger than updrafts without liquid water at similar temperatures, however.

Stith, Jeffrey L.↗