Search NASA⌕ Search

SEARCH · Search NASA

Results for “cold temperatures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Impact of El Niño‐Southern Oscillation and Madden‐Julian Oscillation on the US Puget Sound Regional Hydroclimate

El Niño-Southern Oscillation (ENSO) and Madden-Julian Oscillation (MJO) are two major modes of climate variability with global hydroclimate impacts. However, their impacts often depend on the local climate and geography, resulting in large regional differences. In this study, we examined the connection of ENSO and MJO to the hydroclimate conditions and extremes in the Puget Sound (PS) basin located in the US Pacific Northwest coast. The results indicate that ENSO significantly modulates the cold season temperature and temperature-mediated hydrologic processes. El Niño cold seasons feature less snow accumulation and intensified surface runoff, even if the precipitation amount is similar to La Niña cold seasons. Therefore, El Niño causes more snow drought (in the form of compound dry and warm snow drought) and shifts the surface runoff seasonality by reducing runoff in the subsequent warm season. MJO phases 6–7 trigger more extreme precipitation, temperature, snowmelt, and runoff in the PS region at 0–9–day lags, and such connections are robust regardless of how the ENSO signals are removed. Meanwhile, MJO modulates large-scale extreme weather systems (e.g., atmospheric rivers) with significant enhancement during phases 6–7. ENSO impacts have intensified in the 2001–2020 period, whereas MJO impacts showed some phase shift in this period. This study reveals ENSO and MJO phases 6–7 as useful predictors of the PS hydroclimate anomalies/extremes at seasonal and daily scales, respectively. Utilizing these findings holds the potential to improve regional water resources prediction and management.

ENSO↗

Field Validation of Air-Source Heat Pumps for Cold Climates

Heating energy is the largest end-use for U.S. residential buildings accounting for approximately one-third of residential building energy consumption (EIA 2021). Historically, air-source heat pumps have been limited to temperate climates because of subpar performance at extremely cold outdoor air temperatures. However, recent advances to cold-climate air-source heat pump technology, which typically rely on inverter-driven, variable-speed compressors and variable-speed fans, have significantly improved low-temperature heat pump performance enabling the technology to save energy for many homes in cold climates. The primary objective of this project was to measure in-field performance of centrally ducted, variable-capacity air-source heat pumps in cold climates to validate performance and develop field-based performance maps. The project focused on quantifying heat pump performance at cold temperatures. The sites identified for the study were primarily located in the Northwest United States since homes in the region tend to have all-electric space heating systems and high-efficiency heat pumps have been incentivized in the region for several years. NREL partnered with Ecotope, Inc., a small energy consulting firm located in Seattle, WA, for site recruitment, monitoring equipment installation, data quality management. All the sites included in the study had previously installed a high-efficiency, central heat pump system. One site was in a Denver, CO suburb, which was the only dual fuel heat pump in the study. We used airside and power measurements, collected at 5-second intervals, to quantify heat pump capacity, coefficient of performance (COP), and auxiliary heater energy consumption. We developed algorithms to automatically determine the heat pump operating mode including defrost and auxiliary heating operation. A whole-house thermal and duct audit was completed during the initial site visit to estimate winter heating loads and assess heat pump sizing. Whole-home heating design loads were calculated at ASHRAE 99% design temperatures and compared to manufacturer-reported maximum capacities to assess the heat pump sizing at each site.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impact of Selected High-Performance Fuel Blends on Three-Way Catalyst Light Off under Synthetic Spark-Ignition Engine-Exhaust Conditions

The U.S. Department of Energy funded Co-Optimization of Fuels and Engines initiative aims to simultaneously develop advanced engines along with high-performance fuels to reduce petroleum consumption. The engine exhaust of spark-ignited light-duty vehicles contains pollutants such as nitrogen oxides, carbon monoxide (CO), and non-methane organic gases. When operated above their “light-off” temperature, three-way catalysts (TWCs) efficiently control the emissions of these pollutants from the vehicle exhaust. However, below the catalyst light-off temperature, during cold start, the TWCs are not effective. Thus, the stringent environmental regulations necessitate cold-start compliance of advanced engines operating on novel fuels for commercialization. Exhaust composition strongly impacts the effectiveness of TWCs. Hence, ensuring that the high-performance fuels under consideration do not have detrimental effects on current emissions control technology is necessary. To mitigate cold-start emissions, a low light-off temperature of the fuel on the TWC is desirable. As real-world fuels are multicomponent blends, we conducted investigations into the light-off behavior of representative fuel mixtures on a three-mode redox-aged commercial TWC under synthetic engine-exhaust conditions. The high-performance fuels in this study included 10–30% volumetric levels of ethanol, isobutanol, diisobutylene, and an aromatic mixture. Each of these high-performance fuel components was mixed into a gasoline surrogate blendstock for oxygenate blending (BOB). Our results showed that aromatics and alkenes in the surrogate BOB inhibit low-temperature reactivity of alkanes, alcohols, and CO on the TWC and dominate the blend light-off behavior. All the high-performance fuel blends had a very similar light-off behavior to the surrogate gasoline BOB, indicating that blending up to 30% (by vol.) of high-performance blendstocks in a gasoline base fuel can potentially reduce greenhouse gas emissions through improved engine efficiency and petroleum displacement without jeopardizing the ability to meet emissions regulations. While some high-performance blendstocks demonstrated lower light-off temperatures than a surrogate gasoline blend, taking advantage of the higher catalytic reactivity of these blendstocks to reduce cold-start emissions would require reducing the aromatic content in petroleum-based market fuels.

33 ADVANCED PROPULSION SYSTEMS↗

Effect of Rocky Mountains and Tibetan Plateau 1998 Spring Land Temperature on N. American and East Asian Summer Precipitation Anomalies

This work follows up on the GEWEX/LS4P Phase I (LS4P-I) experiments, a community effort highlighting the spring land surface temperature anomalies in the Tibetan Plateau (TP) as a useful source for subseasonal to seasonal (S2S) prediction of summer precipitation in global hot spot regions, particularly in East Asia and North America. This paper extends the investigation to both the US Rocky Mountain (RM) region and the TP, considering the 1998 summer drought/flood event in North America/East Asia, respectively, as a case study. A previously developed initialization method for land surface temperature/subsurface temperature (LST/SUBT) is used in the NCEP Global Forecast System, coupled with a land model, SSiB2 (GFS/SSiB2), to produce observed RM cold May temperature anomaly. Forward simulation yields June precipitation anomalies at five remote locations. Likewise, the TP warm May temperature anomaly also produces June precipitation anomalies at these five locations. The effects of RM (cold) and TP (warm) temperature anomalies are consistent in the US South Coastal regions and the south Yangtze River Basin, yielding 49% (42%) of observed drought and 34% (44%) of observed flood, respectively. These LST/SUBT effects in RM and TP induce a global large-scale wave train linking North America with the TP, affecting the subtropical westerly jet and thereby modulating summer precipitation. Global SST effect is examined for comparison but does not yield statistically significant June precipitation anomalies in GFS/SSiB2. Furthermore, this study adds to evidence that high-mountain LST effects in the RM and TP are first-order sources of S2S precipitation predictability in summer months.

Nayak, Hara Prasad [University of California, Los ↗

A worldwide climatology of extreme air masses

Extreme temperature events are among the most damaging weather phenomena. In a warming world, more heat extremes and fewer cold extremes are expected in most regions in the future, a trade-off that warrants further understanding of such events. Here, we track and analyze large, persistent areas of hot and cold extreme temperatures in parallel, relative to the location and time of year, to quantify overall regional exposure to extreme temperatures. To accomplish this, we compare the frequencies, movements, trends, and sources/sinks in each type of extreme air mass, calling them extreme cold or extreme hot air masses (ECAMs/EHAMs). For most land regions, ECAMs occur more often than EHAMs, and ECAMs are more common in each hemisphere’s winter, when cold-air advection is strongest and most widespread. Average movement of ECAMs has a stronger equatorward component in winter than in summer, while movement of EHAMs is eastward all year, with less meridional movement than ECAMs. EHAMs have become more common almost everywhere on land, and the reverse is true for ECAMs, with the strongest trends in the northern hemisphere occurring in autumn, especially in the Arctic. The number of EHAMs around the world is increasing at a higher rate (+ 2.32 events/year) than ECAM numbers are decreasing (-1.27 events/year), causing a net increase in extremes, especially in some midlatitude regions. These results help to document the different processes driving hot and cold extremes, and thus the asymmetric and regionally varying trends in frequency for extreme air masses.

Ryan, James M↗

Melting rate correlation with batch properties and melter operating conditions during conversion of nuclear waste melter feeds to glasses

The rate of conversion of nuclear waste melter feed to glass is affected by the selection of melter feed materials and by melter design and operation. The melting rate correlation (MRC) is an equation that relates the glass production rate with two types of variables: (1) feed and melt properties: conversion heat, cold-cap bottom temperature, and glass melt viscosity; and (2) melter design and operation parameters: melter geometry, melter operating temperature, and gas bubbling rate. The MRC shows good agreement for an extended melting-rate data set of high-level waste (HLW) melter feeds and a data set generated for low-activity waste (LAW) melter feeds. Laboratory observation of heated melter feed samples is often used to assess the cold-cap bottom temperature of HLW melter feeds (moderately foaming feeds), but this technique appears inadequate for LAW melter feeds (vigorously foaming feeds). For LAW feeds, an adequate assessment of the cold-cap bottom temperature was achieved using evolved gas analysis, which allows identification of the collapse of primary foam for oxidized feeds. This assessment shows that the cold-cap bottom temperature for vigorously foaming LAW feeds is higher than that for moderately foaming HLW feeds. When the results of MRC are compared, LAW feeds are generally less sensitive to the bubbling rate and melt viscosity, and more sensitive to the cold-cap bottom temperature than HLW feeds. The MRC qualifies as a promising tool to support the selection of melter feed materials and melter operating conditions, which is determined from expensive independent scaled melter experiments, and sophisticated mathematical models.

Lee, Seung Min↗

Allosteric regulation of thioesterase superfamily member 1 by lipid sensor domain binding fatty acids and lysophosphatidylcholine

Nonshivering thermogenesis occurs in brown adipose tissue to generate heat in response to cold ambient temperatures. Thioesterase superfamily member 1 (Them1) is transcriptionally up-regulated in brown adipose tissue upon exposure to the cold and suppresses thermogenesis in order to conserve energy reserves. It hydrolyzes long-chain fatty acyl-CoAs that are derived from lipid droplets, preventing their use as fuel for thermogenesis. In addition to its enzymatic domains, Them1 contains a C-terminal StAR-related lipid transfer (START) domain with unknown ligand or function. By complementary biophysical approaches, we show that the START domain binds to long-chain fatty acids, products of Them1’s enzymatic reaction, as well as lysophosphatidylcholine (LPC), lipids shown to activate thermogenesis in brown adipocytes. Certain fatty acids stabilize the START domain and allosterically enhance Them1 catalysis of acyl-CoA, whereas 18:1 LPC destabilizes and inhibits activity, which we verify in cell culture. Additionally, we demonstrate that the START domain functions to localize Them1 near lipid droplets. Overall, these findings define the role of the START domain as a lipid sensor that allosterically regulates Them1 activity and spatially localizes it in proximity to the lipid droplet.

60 APPLIED LIFE SCIENCES↗

Sealability Qualification of Material Extruded Zytel Gaskets at Extreme Temperatures

In this work, an in-depth qualification of additively manufactured Zytel for gasketing proton exchange membrane fuel cells (PEMFC’s) subject to extreme temperature conditions. The temperature cycling of the PEMFC from 55°C to 100°C accelerates the deterioration of these gaskets compared to that of conventional operation. The additive manufacturing process employed to print these gaskets is material extrusion using Zytel filament. In order to see the effects of the temperature of interest on the printed specimen, each specimen was thermally soaked and then charactered and tested according to ASTM standard F37B. ASTM F37B tests a materials ability to seal and maintain it while bearing both a compressive load and internal pressure load to simulate being in static operation. This process of thermally soaking and sealability testing is shown to show the validity of both this material and additive manufactured components for other applications as well. It is observed that soaking the gaskets at 100°C corrects some of the defects that are present after printing such as missing layers and small voids on the surface of the samples. This allowed for the hot soaked materials to perform better than the samples at room temperature and cold soaked.

Sealability↗

Benzotriazole‐Based Nonfused Ring Acceptors for Efficient and Thermally Stable Organic Solar Cells

Abstract Nonfused ring acceptors (NFRAs) have attracted significant attention for nonfullerene organic solar cells (OSCs) owing to their chemical tunability and facile synthesis. In this study, a benzotriazole‐based NFRA with chlorinated end groups (Triazole‐4Cl) is developed to realize highly efficient and thermally stable NFRA‐based OSCs; an analogous NFRA with nonchlorinated end groups (Triazole‐H) is synthesized for comparison. Triazole‐4Cl film exhibits the high‐order packing structure and the near‐infrared absorption capability, which are advantageous in charge transport and light harvesting of the resulting OSCs. In particular, the strong crystalline behavior of Triazole‐4Cl results in enhanced self‐aggregation, leading to high charge carrier mobility. Owing to these properties, a PBDB‐T (polymer donor):Triazole‐4Cl OSC demonstrates a high short‐circuit current, fill factor, and power conversion efficiency (PCE = 10.46%), outperforming a PBDB‐T:Triazole‐H OSC (PCE = 7.65%). In addition, the thermal stability of a PBDB‐T:Triazole‐4Cl OSC at an elevated temperature of 120 °C exceeds that of a PBDB‐T:Triazole‐H OSC. This is mainly attributed to the significantly higher cold crystallization temperature of Triazole‐4Cl (205.9 °C). This work provides useful guidelines for the design of NFRAs to achieve efficient and thermally stable NFRA‐based OSCs.

Polymer Science↗

Southern Ocean Low Cloud and Precipitation Phase Observed During the Macquarie Island Cloud and Radiation Experiment (MICRE)

Shallow cloud decks residing in or near the boundary layer cover a large fraction of the Southern Ocean (SO) and play a major role in determining the amount of shortwave radiation reflected back to space from this region. In this article, we examine the macrophysical characteristics and thermodynamic phase of low clouds (tops <3 km) and precipitation using ground-based ceilometer, depolarization lidar and vertically-pointing W-band radar measurements collected during the Macquarie Island Cloud and Radiation Experiment (MICRE) from April 2016 to March 2017. During MICRE, low clouds occurred ~65% of the time on average (slightly more often in austral winter than summer). About 2/3 of low clouds were cold-topped (temperatures ≤0°C). These were thicker and had higher bases on average than warm-topped clouds. 83%–88% of cold-topped low clouds were liquid phase at cloud base (depending on the season). The majority of low clouds had precipitation in the vertical range 150–250 m below cloud base, a significant fraction of which did not reach the surface. Phase characterization is limited to the period between April 2016 and November 2016. Small-particle (low-radar-reflectivity) precipitation (which dominates precipitation occurrence) was mostly liquid below-cloud, while large-particle precipitation (which dominates total accumulation) was predominantly mixed/ambiguous or ice phase. Approximately 40% of cold-topped clouds had mixed/ambiguous or ice phase precipitation below (with predominantly liquid phase cloud droplets at cloud base). Below-cloud precipitation with radar reflectivity factors below about -10 dBZ were predominantly liquid, while reflectivity factors above about 0 dBZ were predominantly ice.

54 ENVIRONMENTAL SCIENCES↗

Aridity-Dependent Land Surface Skin Temperature Biases in CMIP5/6

Land surface skin temperature, a critical indicator of climate change, connects the water and energy cycles between the land and the atmosphere. Here, in this study, we evaluate the simulations of land surface skin temperature from the Coupled Model Intercomparison Project Phase 5 (CMIP5) and CMIP6 models with satellite-based datasets and reanalysis. We find systematic cold skin temperature biases over arid regions in CMIP5/CMIP6 simulations. Over arid and semi-arid regions, latent heat biases drive skin temperature biases by evaporative cooling. Over humid regions, surface downward shortwave and albedo biases are relatively more critical. Spatial patterns of biases remain similar in the latest CMIP6 simulations, suggesting systematic biases in land-atmosphere interactions. These biases need to be corrected or considered while using models for future projections.

54 ENVIRONMENTAL SCIENCES↗

Thermodynamic Modeling of Heat Engines Including Heat Transfer and Compression–Expansion Irreversibilities

In this paper, a thermodynamic model based on an endoreversible engine approach is developed to analyze the performance of heat engines operating under different thermodynamic cycles. The model considers finite heat transfer rate, variable heat source and sink temperatures, and irreversibilities associated with the expansion and compression. Expressions for the maximum power and efficiency at maximum power output are obtained as a function of hot and cold reservoir temperatures, the equivalent isentropic efficiency of compression and expansion components, and the effective conductance ratio between heat exchangers. In all cases, the Curzon–Ahlborn efficiency is retrieved at constant reservoir temperatures and neglected compression–expansion irreversibilities. The proposed model allows assessing the effect of isentropic efficiencies and heat exchanger design and operation characteristics for different thermodynamic cycles.

33 ADVANCED PROPULSION SYSTEMS↗

Experimental investigation of a closed vapour box module for a divertor-like configuration in Magnum-PSI

Efficient management of extreme heat fluxes in the divertor region to extend the lifetime of the components remains a critical challenge for the realization of nuclear fusion-based power plants. Among the alternative concepts explored for the divertor region, the use of liquid metals, particularly lithium, is of interest due its ability to dissipate the incoming plasma heat flux through the vapour shielding effect (VS). In this work, we experimentally investigated a ‘closed’ configuration of a dedicated Vapour Box Module (VBM) in the linear plasma device Magnum-PSI. The goal of the experiments is to simulate the vapour box divertor environment conditions and assess its performance in terms of power mitigation and redistribution and lithium confinement. Initial testing without Li demonstrated the efficacy of a closed VBM structure in inducing detachment via neutral gas accumulation. Apertures which enabled non-condensing gas to be effectively pumped while ensuring lithium condensed on the inner surfaces were therefore added. With a lithium capillary porous structure target used, lithium is directly vaporized by the plasma, forming a dense lithium vapour cloud that interacts with the incoming plasma. This resulted in a significant reduction of the target temperature of at least 48%, together with a temperature locking effect, a phenomenon typically observed in the VS regime. Lithium vapour confinement within the VBM was strongly correlated with the wall temperature. Relatively cold walls promoted Li re-condensation and therefore improved Li confinement, although with the expected trade-off of increased hydrogenic retention on lithium-wetted surfaces. As the wall temperature increased, the confinement efficiency decreased, consistent with reduced Li re-condensation and thermally activated Li–H chemistry and remobilization at the walls. Diagnostic measurements through embedded thermocouples and calorimetry revealed that lithium vaporization and re-condensation processes also playedsignificant roles in plasma power dissipation. The results advance the case for a closed divertor chamber with direct lithium evaporation from the strike-points as a viable method to manage divertor heat fluxes in future fusion reactors.

Romano, Fabio [Dutch Institute for Fundamental Ene↗

Preliminary Development of Heat Transfer Model-Based Control Algorithms of Liquid Sodium Purification System: Advanced Sensors and Instrumentation Advanced Controls

Monitoring the operation of sodium purification system is essential for efficient operation of sodium fast reactors. In this work, a heat transfer model has been developed for monitoring the plugging meter and cold trap systems at the Mechanisms Engineering Test Loop (METL) liquid sodium facility at Argonne National Laboratory. The model of the purification system was developed by treating the respective aspects of the cold trap purification loop and plugging meter diagnostic loop as two separate control volumes using information from the METL piping and instrumentation diagram (P&ID). A model predictive controller was designed using first order differential equations with the specified boundary conditions. The system behavior was studied with a tuned optimized procedure using the internal cold trap temperature and plugging meter outlet temperature as control variables, and the air blower temperature as an independent variable respectively. Results of computer simulations obtained in this study compared favorably with experimental data showing very good reference tracking response with negligible overshoot as both plugging meter and cold trap physical models approach the setpoint.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Sensitivity and Uncertainty Analysis of Generator Failures under Extreme Temperature Scenarios in Power Systems

This report summarizes work done under the Verification, Validation, and Uncertainty Quantification (VVUQ) thrust area of the North American Energy Resilience Model (NAERM) Program. The specific task of interest described in this report is focused on sensitivity analysis of scenarios involving failures of both wind turbines and thermal generators under extreme cold-weather temperature conditions as would be observed in a Polar Vortex event.

17 WIND ENERGY↗

Asymmetric temperature equilibration with heat flow from cold to hot in a quantum thermodynamic system

A model computational quantum thermodynamic network is constructed with two variable temperature baths coupled by a linker system, with an asymmetry in the coupling of the linker to the two baths. It is found in computational simulations that the baths come to “thermal equilibrium” at different bath energies and temperatures. In a sense, heat is observed to flow from cold to hot. Additionally, a description is given in which a recently defined quantum entropy S univ Q for a pure state “universe” continues to increase after passing through the classical equilibrium point of equal temperatures, reaching a maximum at the asymmetric equilibrium. Thus, a second law account Δ S univ Q ≥ 0 holds for the asymmetric quantum process. In contrast, a von Neumann entropy description fails to uphold the entropy law, with a maximum near when the two temperatures are equal, then a decrease Δ S v N < 0 on the way to the asymmetric equilibrium.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Sub-1K Cold-Electron Quantum Well Switching at Room Temperature

Quantum states can provide means to systematically manipulate the transport of electrons. Here, in this study, we present electron transport across quasi-bound states of two heterogeneous quantum wells (QWs), where the transport of thermally excited electrons is blocked or enabled depending on the relative positions of the two quasi-bound states, with an abrupt current onset occurring when the two QW states align. The QW switch comprises a source (Cr), QW1 (Cr 2 O 3 ), QW2 (SnO x , x < 2), a tunneling barrier (SiO 2 ), and a drain (Si), where the effective electron mass of QW1 (m* QW1 ) is selected to be larger than QW2 (m* QW2 ). The current-voltage (I-V) measurements of the fabricated devices show abrupt current onsets, with the current transition occurring within 0.25 mV, corresponding to an effective electron temperature of 0.8 K at room temperature. Since transistor power consumption is fundamentally tied to effective electron temperature, this sub-1K cold-electron QW switching holds promise for highly energy-efficient computing.

Fermi−Dirac thermal smearing↗