Search NASA⌕ Search

SEARCH · Search NASA

Results for “consistent filtering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Ultraviolet photometry of Nova Serpentis 1970

The appearance of the bright nova, Nova Serpentis 1970, provided the first opportunity to obtain spectrophotometric observations of a nova in the vacuum ultraviolet. OAO-2 carried out systematic measurements from shortly after outburst on through the first sixty days of nova activity. This data consist of filter photometry and spectral scans. General characteristics of the light and spectral variations in the ultraviolet exhibited by this set of data are described.

Code, A. D.↗

Quantification of geologic lineaments by manual and machine processing techniques

A study was conducted to investigate the effect of operator variability and subjectivity in lineament mapping and to examine methods to minimize or eliminate these problems by use of several machine preprocessing methods. LANDSAT scenes from the Anadarko Basin of Oklahoma and the Colorado Plateau were analyzed as test cases. Four geologists mapped lineaments on an Anadarko Basin scene, using transparencies of MSS bands 4-7, and their results are compared statistically. The total number of fractures mapped by the operators and their average lengths varied considerably, although comparison of lineament directions revealed some consensus. A summary map (785 linears) produced by overlaying the maps generated by the four operators showed that only 0.4% were recognized by all four operators, 4.7% by three, 17.8% by two and 77% by one operator. Two methods of machine aided mapping were tested, both simulating directional filters. One consists of computer (digital) processing of CCTs using edge enhancement algorithms, the other employs a television (analog) scanning of an image transparency which superimposes the original image and one offset in the direction of the scan line.

Podwysocki, M. H.↗

Fixed-point single-precision estimation

Monte Carlo simulation of autonomous orbit determination has validated the use of an 18-bit NASA Standard Spacecraft Computer (NSSC) for the extended Kalman filter. Dimensionally consistent scales are chosen for all variables in the algorithm, such that nearly all of the onboard computation can be performed in single precision without matrix square root formulations. Allowable simplifications in algorithm implementation and practical means of ensuring convergence are verified for accuracies of a few km provided by star/vertical observations

Thompson, E. H.↗

Narrow- and broad-band satellite measurements of shortwave radiation - Conversion simulations with a general circulation model

The Oregon State University/Lawrence Livermore National Laboratory general circulation model has been employed as a vehicle for suggesting and exploring various means of converting narrow-band measurements of reflected solar radiation from the earth-atmosphere system to broad-band quantities. For purely illustrative purposes within the model's solar radiation routine, a narrow-band filter function consisting of a square-wave window extending from 0.5 to 0.9 microns is adopted. A limitation of the model, for this sort of endeavor, is that it does not include the wavelength dependence of surface albedos. Nevertheless, the model simulations tend to mimic the calibration of a narrow-band instrument, utilizing reflected solar radiation from the earth-atmosphere system as simultaneously measured by a collocated broad-band instrument; for the model, however, this is done in terms of fluxes, in contrast to instrument-measured radiances. The model results suggest that it might be preferable to perform narrow- to broad-band conversions in terms of planetary albedo (or an equivalent quantity), rather than in terms of reflected fluxes or radiances. Further improvement is achieved if, for instruments that can differentiate between clear and overcast conditions, separate clear and overcast calibrations are performed.

Cess, Robert D.↗

Swift and GRB's: Unveiling the Relativistic Universe

We report Swift observations of GRB 051109A, a bright, long burst detected with BAT. A bright afterglow was quickly detected with the X-Ray Telescope and Ultraviolet and Optical Telescope, and observations continued for more than 10 days. The X-ray light is complex with a rapid initial decay followed by a more gradual decay. There is evidence for a jet break with an indicated opening angle of a few degrees. UVOT observations with the V filter are consistent with a power-law day for the first 10 ks. We discuss the observations in light of current models.

Marshall, Francis E.↗

Superconducting Quantum Arrays for Wideband Antennas and Low Noise Amplifiers

Superconducting Quantum Iinetference Filters (SQIF) consist of a two-dimensional array of niobium Josephson Junctions formed into N loops of incommensurate area. This structure forms a magnetic field (B) to voltage transducer with an impulse like response at B0. In principle, the signal-to-noise ratio scales as the square root of N and the noise can be made arbitrarily small (i.e. The SQIF chips are expected to exhibit quantum limited noise performance). A gain of about 20 dB was recently demonstrated at 10 GHz.

SQUID Detectors↗

Sub-drain Water Treatment Facility for Reduction of Accumulated Waste Water Amount at the Fukushima NPS Site - 17572

At the Fukushima Daiichi Nuclear Power Station site, water treatment facility special for sub-drain and groundwater drain has been constructed by Tokyo Electric Power Company Holdings, Inc. and Hitachi-GE Nuclear Energy, Ltd., and it has been operated to remove radionuclides from the pumped groundwater. The facility consists of three kinds of equipment for collecting, purifying and transferring. The purification equipment removes radionuclides contained in the pumped groundwater. The purification equipment consists of filters for removal of solids and colloidal particles, and adsorbents for removal of ionic radionuclides. Five adsorption vessels are installed into the equipment; three vessels have adsorbent to remove Cs and Sr simultaneously, the fourth vessel has adsorbent to remove Sb and for the last has adsorbent to remove heavy metals. The vessels for Cs and Sr are operating as a so-called 'merry-go-round'. For the rational operation of the equipment, a simulation code has been developed to calculate the Sr concentration of outlet water which determines the replacement timings of the Cs-Sr adsorption vessels. The simulation code has been applied to planning of vessel replacement during the water treatment facility operation. The facility started operation in September 2015, and treated the pumped groundwater since then. As of October 2016, about 211,000 m{sup 3} of groundwater had been treated. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

RO concentrated water treatment equipment for risk reduction of contaminated water stored in tank in Fukushima NPS - 16655

At the Fukushima Daiichi Nuclear Power Station (NPS) site, concentrated waste water was stored in tanks, awaiting treatment to remove radionuclides using various multi-nuclide removal systems. To accelerate the treatment for risk reductions of radiation dose and tank leakage, we constructed reverse-osmosis (RO) concentrated water treatment equipment. The equipment consists of filters and five adsorbent vessels containing Cs-Sr simultaneous adsorbents with the removal ability of Sr being 1/1000(max) to 1/100(min), and the overall treatment capacity of 500 to 900 m{sup 3}/day. We developed a simulation code to calculate the Sr concentration of outlet water for each vessel in order to evaluate the bed life of the media. The simulation code makes it possible to plan when to change media in the vessels during the equipment operation. The successful treatment of concentrated waste water was conducted using the equipment from January to May 2015. Total amount of water treated was 82,194 m{sup 3}. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A monolithic polarization-independent frequency-filter system for filtering of photon pairs

We set up a long-term stable filtering system that consists of cascaded monolithic Fabry-Pérot filters to enhance the suppression and free spectral range. An effective free spectral range of hundreds of GHz allows the system to be used as a high resolution monochromator, with a linewidth of 192 MHz. As an important application a single mode is filtered from photon pairs generated by a parametric down-conversion source, and their indistinguishability is proven by measuring the Hong-Ou-Mandel effect with a visibility of 96%. We report that undesired birefringence, which is often encountered with monolithic cavities, can be avoided by stress-free mounting.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Structural, chemical, and electronic control in Co–SiNx granular metals for high-pass filter applications

Granular metals, consisting of nanoscale conducting and insulating regions, have been studied for more than 50 years for fundamental and applied research. Granular metals exhibit non-linear conductivity vs frequency behavior, consistent with the universal power law response, and have recently been suggested for high-pass filter applications. Here, we report that cobalt–silicon nitride (Co–SiNx) granular metals with optimized sputter conditions and post-growth annealing exhibit an exceptional 109 increase in conductivity at 1 MHz compared to the DC conductivity. The improved frequency response is correlated with structural and chemical improvements examined via scanning transmission electron microscopy and x-ray photoemission spectroscopy. While we focus on improvements for high-pass filter applications, the structural, chemical, and electronic control demonstrated here will benefit a variety of granular metal and nanoparticle applications.

Annealing↗

Wilkinson Microwave Anisotropy Probe (WMAP) Attitude Estimation Filter Comparison

The Wilkinson Microwave Anisotropy Probe (WMAP) spacecraft was launched in June of 2001. The sensor complement of WMAP consists of two Autonomous Star Trackers (ASTs), two Fine Sun Sensors (FSSs), and a gyro package which contains redundancy about one of the WMAP body axes. The onboard attitude estimation filter consists of an extended Kalman filter (EKF) solving for attitude and gyro bias errors which are then resolved into a spacecraft attitude quaternion and gyro bias. A pseudo-linear Kalman filter has been developed which directly estimates the spacecraft attitude quaternion, rate, and gyro bias. In this paper, the performance of the two filters is compared for the two major control modes of WMAP: inertial mode and observation mode.

Harman, Richard R.↗

A Preliminary Analysis of Dose Rates Associated with ITER CVCS Equipment/Area Location

A preliminary analysis of the ITER Chemical and Volume Control System (CVCS) Area was performed to assess dose rates outside the walls and ceiling of the facility after 1.5 years of operation at shutdown, 2 days, and 10 days after shutdown. For this purpose a simplified Monte Carlo computer model was developed using the MCNP (MCNP5 Ver. 1.51) code. Two components are included: the smaller filter tank and the larger ion exchanger. These pieces of equipment are associated with the Integrated Blanket ELM Divertor Primary Heat Transfer System, which will have the largest dose rates associated with activated corrosion products during operation in comparison with other systems. The ion exchanger contained two source regions, a 1.2-m-thick resin bed above a 0.55 m-thick skirt, and a 0.8-m-thick water region. The filter constituted an additional source. Thus the model consisted of three sources (filter, resin, water), homogeneously distributed within the appropriate source regions. However, much of the results (that address individual isotopes) are presented with the two sources in the ion exchanger combined. In these cases the sources are referred to as the 'ion exchanger source' and the 'filter source.' Dimensions for the facility and components, as well as source isotopes and strengths, and material densities, were supplied by US ITER. Because of its simplification, the model does not contain pipes. Consequently, radiation streaming through pipe penetrations, radiation emanating from the pipes, and shielding from the pipes were not considered in this analysis. Dose rates on the outside of two walls and the ceiling were calculated. The two walls are labeled as the 'long' wall (aligned with the X-axis) and the 'short' wall (aligned with the Y-axis). These walls and ceiling were nominally set to 30-cm-thick concrete. In the original analysis, standard concrete (2.3 g/cc density) was used. In addition to the shielding walls/ceiling, a floor and an additional wall opposite the long wall were added for photon scattering contributions. These were both 10-cm-thick, standard concrete structures. Other components (tanks, pipes, etc.), that were not included in the model, would potentially add additional scattering and shielding. Possibly these additional effects will be addressed in a later, more detailed analysis. The room was 29.6 m in length (X-axis), but was limited to 15 m in the model. The inside width (Y axis) and height (Z axis) were 4 m and 3.4 m, respectively. The origin for the model was located inside the room at the corner opposite the long wall and adjacent to the short wall at the floor level. The room was filled with air at standard temperature and pressure. The stainless steel (SS304) wall thicknesses for the ion exchanger and filter were 2.2 cm and 0.8 cm, respectively. The axial center of the filter was located 140 cm from the short wall and 100 cm from the long wall (outer surface). The axial center of the ion exchanger was located 440 cm from the short wall and 250 cm from the long wall (inner surface). The resin was assumed to be a homogeneous mixture of equal atom density fractions of hydrogen and carbon* at a specified density of 1.136 g/cc. The filter material was assumed to be homogeneous carbon at a specified density of 1.8 g/cc. If the filter media were stainless steel and the accumulated activity were the same, the dose rate outside the filter would be lower, provided the density of the stainless steel sintered filter material is significantly higher than 1.8g/cc. The densities of the water and air were assumed to be 1.0 g/cc and 1.096E-3 g/cc, respectively. The model included 10 small volumes placed outside the model adjacent to the wall at locations where the dose rates were expected to be highest and which showed to a degree the fall-off of the dose rate with distance along a particular wall or ceiling. These 'tally cells' are shown in Fig. 2 and are described in Table 1. Each cell had dimensions of 50 cm x 50 cm x 1 cm and was oriented so that the 1-cm-thick dimension was perpendicular to the wall against which the cell was located. Also, smaller tally volumes were placed at 5 cm (updated model), 30 cm, 50 cm, and 100 cm from each source, both radially from the outside of each component at the height of each source mid-plane, and vertically, along the axial centerline, above the ion-exchanger and below the filter. (For the ion exchanger, the vertical distance was limited to 75 cm because of interference from the ceiling.) These tally regions can be seen in Fig. 3. Each cell had dimensions of 5 cm x 5 cm x 1 cm, oriented so that the 1-cm-thick dimension was perpendicular to the X, Y or Z axis.

08 HYDROGEN↗

Advanced Techniques for Removal of Retrievable Inferior Vena Cava Filters

Inferior vena cava (IVC) filters have proven valuable for the prevention of primary or recurrent pulmonary embolism in selected patients with or at high risk for venous thromboembolic disease. Their use has become commonplace, and the numbers implanted increase annually. During the last 3 years, in the United States, the percentage of annually placed optional filters, i.e., filters than can remain as permanent filters or potentially be retrieved, has consistently exceeded that of permanent filters. In parallel, the complications of long- or short-term filtration have become increasingly evident to physicians, regulatory agencies, and the public. Most filter removals are uneventful, with a high degree of success. When routine filter-retrieval techniques prove unsuccessful, progressively more advanced tools and skill sets must be used to enhance filter-retrieval success. These techniques should be used with caution to avoid damage to the filter or cava during IVC retrieval. This review describes the complex techniques for filter retrieval, including use of additional snares, guidewires, angioplasty balloons, and mechanical and thermal approaches as well as illustrates their specific application.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Minimum entropy filtering for a single output non-Gaussian stochastic system using state transformation

This paper presents a novel filter design for the single-output stochastic non-linear systems subjected to non-Gaussian noises and the proposed assumptions. Based on a state transformation, the unmeasurable states of the systems can be estimated where non-linear terms in the systems have been eliminated. It has been shown that the estimation error is linearly dynamical regarding to the presented vector-valued filter gain which can be optimised by minimising the entropy-based performance criterion. In addition, the convergence of the presented algorithm is analysed in mean-square sense and a numerical example is given to verify the effectiveness of the presented filtering algorithm. Meanwhile, the extended Kalman filter, unscented particle filter and minimum entropy filter are given for the comparisons of the filtering performance. Following the presented framework, some extensions of the presented filtering algorithm are discussed to indicate the flexibility of the filter design. The contribution of this paper can be summarised as establishing a novel minimum entropy filtering framework which consists of model transformation, entropy optimisation and convergence analysis.

42 ENGINEERING↗

Analytical study to define a helicopter stability derivative extraction method, volume 1

A method is developed for extracting six degree-of-freedom stability and control derivatives from helicopter flight data. Different combinations of filtering and derivative estimate are investigated and used with a Bayesian approach for derivative identification. The combination of filtering and estimate found to yield the most accurate time response match to flight test data is determined and applied to CH-53A and CH-54B flight data. The method found to be most accurate consists of (1) filtering flight test data with a digital filter, followed by an extended Kalman filter (2) identifying a derivative estimate with a least square estimator, and (3) obtaining derivatives with the Bayesian derivative extraction method.

Molusis, J. A.↗

Quasi Stationary States in the Southern Hemisphere

Pattern correlations between daily anomalies (Horel 1984) were used to study the persistency of the Southern Hemisphere circulations. The data set consists of the daily Australian analyses of 500 mb heights and sea level pressure for the period from 1972 and 1983. Compared to the Northern Hemisphere, the pattern correlations are much smaller and more variable in the Southern Hemisphere. The mean one day lag is only 0.57, (0.82 for the NH). The correlations increase significantly for the filtered anomalies which consist of the long planetary waves from 0 to 4. Subjective criteria based on the pattern correlations are used to select the quasi stationary events. A series of 5 or more daily maps is quasi stationary if the pattern correlations between all consecutive pairs of maps in this time series are larger or equal to 0.5.

Mo, K. C.↗

DWPF DECON FRIT SUPERNATE ANALYSIS

The Savannah River National Laboratory (SRNL) has been requested to perform analyses on samples of the Defense Waste Processing Facility (DWPF) decon frit slurry (i.e., supernate samples and sump solid samples). Four 1-L liquid slurry samples were provided to SRNL by Savannah River Remediation (SRR) from the 'front-end' decon activities. Additionally, two 1-L sump solids samples were provided to SRNL for compositional and physical analysis. This report contains the results of the supernate analyses, while the solids (sump and slurry) results will be reported in a supplemental report. The analytical data from the decon frit supernate indicate that all of the radionuclide, organic, and inorganic concentrations met the limits in Revision 4 of the Effluent Treatment Plant (ETP) Waste Acceptance Criteria (WAC) with the exception of boron. The ETP WAC limit for boron is 15.0 mg/L while the average measured concentration (based on quadruplicate analysis) was 15.5 mg/L. The measured concentrations of Li, Na, and Si were also relatively high in the supernate analysis. These results are consistent with the relatively high measured value of B given the compositional make-up of Frit 418. Given these results, it was speculated that either (a) Frit 418 was dissolving into the supernate or aqueous fraction and/or (b) fine frit particulates were carried forward to the analytical instrument based on the sampling procedure used (i.e., the supernate samples were not filtered - only settled with the liquid fraction being transferred with a pipette). To address this issue, a filtered supernate sample (using a 0.45 um filter) was prepared and submitted for analysis. The results of the filtered sample were consistent with 'unfiltered or settled' sample - relatively high values of B, Li, Na, and Si were found. This suggests that Frit 418 is dissolving in the liquid phase which could be enhanced by the high surface area of the frit fines or particulates in suspension. Based on the results of this study, it is recommended that DWPF re-evaluate the technical basis for the B WAC limit (the only component that exceeds the ETP WAC limit from the supernate analyses) or assess if a waiver or exception can be obtained for exceeding this limit. Given the possible dissolution of B, Li, Na, and Si into the supernate (due to dissolution of frit), DWPF may need to assess if the release of these frit components into the supernate are a concern for the disposal options being considered. It should be noted that the results of this study may not be representative of future decon frit solutions or sump/slurry solids samples. Therefore, future DWPF decisions regarding the possible disposal pathways for either the aqueous or solid portions of the Decon Frit system need to factor in the potential differences. More specifically, introduction of a different frit or changes to other DWPF flowsheet unit operations (e.g., different sludge batch or coupling with other process streams) may impact not only the results but also the conclusions regarding acceptability with respect to the ETF WAC limits.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Quasi-stationary states in the Southern Hemisphere

Pattern correlations between daily anomalies have been used to study the persistence of the Southern Hemisphere circulations. The dataset consists of daily Australian analyses of 500 mb heights and sea level pressure for the period from 1972 to 1983. Compared to the Northern Hemisphere, the pattern correlations are much lower and more variable in the Southern Hemisphere. The mean one-day lag autocorrelation is only 0.57, compared to 0.81 in the Northern Hemisphere. The correlations increase significantly for the filtered anomalies, which consist of the planetary wavenumbers from 0 to 4. Subjective criteria based on the pattern correlations are used to select quasi-stationary events. A series of 5 or more daily maps is defined to be quasi-stationary if the pattern correlations between all pairs of five consecutive maps in this time series are larger than or equal to 0.5. In winter, quasi-stationary events can be classified in terms of wavenumbers. Waves 3 and 4 are by far the dominant waves. More than half of the events have large wave 3 amplitude with geographically fixed orientations.

Mo, K. C.↗