Search NASA⌕ Search

SEARCH · Search NASA

Results for “continuous operation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Adaptive Fault Current-Limiting Control of MMC for Protection of Multiterminal HVDC Systems

A crucial requirement of the protection system for multi-terminal high-voltage DC (MTDC) transmission is that it is capable of selectively isolating the faulty area from the healthy part of the network using DC circuit breakers (DCCBs), while ensuring continuous operation of converter stations in the healthy part of the network. But in the half-bridge modular multilevel converters (HB-MMCs) based MTDC system, since HB-MMCs do not have fault current absorption capability, when a DC fault occurs, the rising fault currents can quickly reach the blocking threshold within a few milliseconds and disrupt the operation of the MMCs in the healthy part. To facilitate fault-ride-through capability of MTDC system, large DC reactors are often considered in series with DCCBs to reduce the rate of rise of the fault current and prevent blocking the MMCs in the healthy part of the DC networks; however, large DC reactors prohibitively increase the cost of the system, introduce stability issues and can create post-fault oscillations. This paper presents an adaptive fault current-limiting control method for MMCs to avoid their blocking and enable the continuous operation of the healthy part of MTDC systems. The method contains two parts: The first part is based on circulating current feedforward control, which emulates virtual reactors in each arm of an MMC, and is immediately activated when the fault current starts to increase to reduce the rate of rise of the fault current. The second part temporarily bypasses all the submodules when the fault current exceeds a preset threshold, complementing the fault current-limiting effect of the first part. Neither part requires fault detection signals, and they are automatically activated during faults. Simulation case studies of a four-terminal bipolar MMC-based high-voltage DC system are presented to demonstrate the effectiveness of the proposed control methods.

active fault current limiting↗

Adaptive Fault Current-Limiting Control of MMC for Protection of Multiterminal HVDC Systems: Preprint

For the development of multi-terminal high voltage DC (MTDC) transmission, it is critical to design the protection system that can selectively isolate the faulty area from the healthy part of the dc grid using DC circuit breakers (DCCBs) while ensuring continuous operation of converter stations in the healthy part. However, because of the lack of fault current blocking capability in half-bridge (HB) modular multilevel converters (MMCs), when a dc fault occurs, the rising fault currents can quickly reach the blocking threshold within a few milliseconds and disrupt the operation of MMCs in the healthy part. Large DC reactors are often considered in series with DCCBs to reduce the rate of rise of fault currents and prevent blocking of MMCs in the healthy part of the grid. However, large DC reactors can prohibitively increase the cost of the system, particularly when they are considered in an offshore environment, for instance in offshore wind projects. Large dc reactors can also introduce stability issues and create post-fault oscillations. This paper presents an adaptive fault current limiting control method for MMCs to avoid their blocking and enable continuous operation of MTDC systems. It contains two parts: The first part is based on circulating current feedforward control that emulates virtual reactors in each arm of an MMC, which is immediately activated when the fault current starts to increase, to reduce the rate of rise of the fault current; the second part is triggered when the fault current exceeds a preset threshold by temporarily bypassing the SMs, serving as a complement to the fault current limiting effect of the first part. Both parts do not require fault detection signal and they are activated automatically during faults. Simulation case studies of a four-terminal bipolar MMC-HVDC system are presented to demonstrate the effectiveness of the proposed control methods.

active fault current limiting↗

Surface Meteorology at Teller Mile 47 Watershed, Seward Peninsula, Alaska, Ongoing from 2018

Meteorological data are currently being collected at one location at the Teller Mile 47 (TL_MM47) Research Basin Site, Seward Peninsula (N64 58' 36.918", W166 12' 32.67", 67 meters above sea level). The site was installed and initial measurements started in September 2018 and it has operated continuously since then. The meteorological station is co-located with a continuous snow depth sensor and two soil pits for subsurface temperature and moisture measurements. These data are being collected to better understand the energy dynamics above the active layer and permafrost. They complement in-situ snow and soil measurements also at this location. The data could also be used as supporting measurements for other research and modeling activities. There are 35 comma separated value format (*.csv) files provided, where each file contains the full data for an individual parameter (e.g. air temperature at 1.5 meters above the ground surface (teller_m47_air_temperature_150cm_ags_Avg.csv) or soil temperature 20 centimeters below ground surface (teller_m47_dry_soil_pit_temperature_20cmbgs_Avg.csv)) plus the time in Universal Coordinated Time (UTC) and Alaska Standard Time (UTC time minus nine hours). The site was installed and initial measurements started in September 2018. It has been operated continuously since. Primary data gaps are due to battery failure or sensor failure. These data are being collected to better understand the surface energy dynamics above the active layer and permafrost. The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a 10-year research effort (2012-2022) to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy?s Office of Biological and Environmental Research. The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska. Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy?s Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Field Validation of a Smart Energy Recovery Ventilation System Using Low-Cost Indoor Air Quality Sensors

This project is a field validation, using low-cost indoor air quality (IAQ) sensors, of a smart ventilation system that can help low-load homes in humid environments maintain acceptable indoor humidity conditions while providing adequate ventilation according to ASHRAE 62.2. The objectives of this research were to (1) address builders’ concerns with mechanical ventilation in humid environments and (2) answer the question of whether smart control logic helps with occupant comfort and the creation of a more acceptable indoor environment. To address the objectives of the study, the Southface team collected field data for one year in four Charleston, South Carolina, new construction homes in order to determine the differences in occupant comfort; comfort metrics; IAQ; and heating, ventilating, and air-conditioning (HVAC) energy consumption when toggling biweekly between an energy recovery ventilator (ERV) operating continuously and an ERV operating with smart, time-varying humidity control logic. The smart ventilation algorithm under consideration in this field test did create a less humid indoor environment on an annual basis as quantitatively measured through temperature and relative humidity (T/RH) readings, expressed most discernably as “percentage of time above 60% RH” and “percentage of time above 55°F dewpoint.” However, the difference it made was inconsistent during the spring, summer, and fall months, and it was only directionally consistent during the winter months. We suspect that this is primarily due to the long runtimes and concomitant dehumidification activity of the air-conditioning (A/C) units in response to the high sensible loads in Charleston. The effect of the smart ventilation algorithm was not discernable to the occupants in this study, as recorded through seasonal surveys.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

LaNi5 Hydrogen-Absorption Cryogenic System

Hydrogen-absorption refrigerating system provides about 650 mW of cooling at 20 to 29 K in continuous, closed-cycle operation. Three thermally cycled absorbers/desorbers act as compressors. System successfully tested below 29 K for over 1,000 h, while separate room-temperature hydride compressor operated continuously for 6,000 h. Due to lack of moving parts, lifetimes of 10 years or more eventually expected.

Jones, J. A.↗

Performance results of cooperating expert systems in a distributed real-time monitoring system

There are numerous definitions for real-time systems, the most stringent of which involve guaranteeing correct system response within a domain-dependent or situationally defined period of time. For applications such as diagnosis, in which the time required to produce a solution can be non-deterministic, this requirement poses a unique set of challenges in dynamic modification of solution strategy that conforms with maximum possible latencies. However, another definition of real time is relevant in the case of monitoring systems where failure to supply a response in the proper (and often infinitesimal) amount of time allowed does not make the solution less useful (or, in the extreme example of a monitoring system responsible for detecting and deflecting enemy missiles, completely irrelevant). This more casual definition involves responding to data at the same rate at which it is produced, and is more appropriate for monitoring applications with softer real-time constraints, such as interplanetary exploration, which results in massive quantities of data transmitted at the speed of light for a number of hours before it even reaches the monitoring system. The latter definition of real time has been applied to the MARVEL system for automated monitoring and diagnosis of spacecraft telemetry. An early version of this system has been in continuous operational use since it was first deployed in 1989 for the Voyager encounter with Neptune. This system remained under incremental development until 1991 and has been under routine maintenance in operations since then, while continuing to serve as an artificial intelligence (AI) testbed in the laboratory. The system architecture has been designed to facilitate concurrent and cooperative processing by multiple diagnostic expert systems in a hierarchical organization. The diagnostic modules adhere to concepts of data-driven reasoning, constrained but complete nonoverlapping domains, metaknowledge of global consequences of anomalous data, hierarchical reporting of problems that extend beyond a single domain, and shared responsibility for problems that overlap domains. The system enables efficient diagnosis of complex system failures in real-time environments with high data volumes and moderate failure rates, as indicated by extensive performance measurements.

Schwuttke, U. M.↗

The International Ultraviolet Explorer (IUE): Six years in orbit

Spacecraft and scientific instrument status of the International Ultraviolet Explorer mission at 6 yr in orbit is discussed. The satellite has been in continuous operations since January 26, 1978 and continues to support science operations normally and effectively in its 7 th year of successful in-orbit operation. Sapcecraft and scientific instrument design requirements and goals are met. Design lifetime of the hardware is 3 yr with a goal, including the sizing of consumables and degradable hardware, of 5 yr.

Faelker, J.↗

A Hybrid Cadre Concept for International Space Station (ISS) Operations

The International Space Station (ISS) is a continuously operating on-orbit facility, with a ten to fifteen year lifetime. The staffing and rotation concepts defined and implemented for the ISS program must take into account the unique aspects associated with long duration mission operations. Innovative approaches to mission design and operations support must be developed and explored which address these unique aspects. Previous National Aeronautics and Space Administration (NASA) man-based space programs, with the exception of Skylab, dealt primarily with short duration missions with some amount of down time between missions; e.g., Shuttle, Spacelab, and Spacehab programs. The ISS Program on the other hand requires continuous support, with no down time between missions. ISS operations start with the first element launch and continue through the end of the program. It is this key difference between short and long duration missions that needs to be addressed by the participants in the ISS Program in effectively and efficiently staffing the positions responsible for mission design and operations. The primary drivers considered in the development of staffing and rotation concepts for the ISS Program are budget and responsiveness to change. However, the long duration aspects of the program necessitate that personal and social aspects also be considered when defining staffing concepts. To satisfy these needs, a Hybrid Cadre concept has been developed and implemented in the area of mission design and operations. The basic premise of the Hybrid Cadre concept is the definition of Increment-Independent and Increment-Dependent cadre personnel. This paper provides: definitions of the positions required to implement the concept, the rotation scheme that is applied to the individual positions, and a summary of the benefits and challenges associated with implementing the Hybrid Cadre concept.

Hagopian, Jeff↗

Min and max are the only continuous ampersand-, V-operations for finite logics

Experts usually express their degrees of belief in their statements by the words of a natural language (like 'maybe', 'perhaps', etc.). If an expert system contains the degrees of beliefs t(A) and t(B) that correspond to the statements A and B, and a user asks this expert system whether 'A&B' is true, then it is necessary to come up with a reasonable estimate for the degree of belief of A&B. The operation that processes t(A) and t(B) into such an estimate t(A&B) is called an &-operation. Many different &-operations have been proposed. Which of them to choose? This can be (in principle) done by interviewing experts and eliciting a &-operation from them, but such a process is very time-consuming and therefore, not always possible. So, usually, to choose a &-operation, the finite set of actually possible degrees of belief is extended to an infinite set (e.g., to an interval (0,1)), define an operation there, and then restrict this operation to the finite set. Only this original finite set is considered. It is shown that a reasonable assumption that an &-operation is continuous (i.e., that gradual change in t(A) and t(B) must lead to a gradual change in t(A&B)), uniquely determines min as an &-operation. Likewise, max is the only continuous V-operation. These results are in good accordance with the experimental analysis of 'and' and 'or' in human beliefs.

Kreinovich, Vladik↗