Search NASA⌕ Search

SEARCH · Search NASA

Results for “controllability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Using Ducted Fuel Injection to Attenuate Soot Formation in a Mixing-Controlled Compression Ignition Engine

Ducted fuel injection (DFI) has been introduced as a strategy to enhance the fuel/charge gas mixing within the combustion chamber of a direct-injection mixing-controlled compression ignition engine. The concept involves injecting each fuel spray through a small tube within the combustion chamber to facilitate the creation of a leaner mixture in the autoignition zone, relative to a conventional free-spray configuration (i.e., a fuel spray that is not surrounded by a duct). While previous experiments demonstrated that DFI lowers both soot incandescence and soot mass in a constant-volume combustion vessel with a single-component normal-alkane fuel (n-dodecane), here we provide the first evidence that the technology provides similar benefits in an engine application using a commercial diesel fuel containing ~30 wt% aromatics. The present study investigates the effects on engine-out emissions and efficiency with a two-orifice injector tip for charge gas mixtures containing 16 and 21 mol% oxygen. The result is that DFI is confirmed to be effective at curtailing engine-out soot emissions. It also breaks the tradeoff between emissions of soot and nitrogen oxides (NOx) by simultaneously attenuating soot and NO x with increasing dilution.

33 ADVANCED PROPULSION SYSTEMS↗

Spacecraft boost and abort guidance and control systems requirement study, boost dynamics and control analysis study. Exhibit A: Boost dynamics and control anlaysis

The simulation developments for use in dynamics and control analysis during boost from liftoff to orbit insertion are reported. Also included are wind response studies of the NR-GD 161B/B9T delta wing booster/delta wing orbiter configuration, the MSC 036B/280 inch solid rocket motor configuration, the MSC 040A/L0X-propane liquid injection TVC configuration, the MSC 040C/dual solid rocket motor configuration, and the MSC 049/solid rocket motor configuration. All of the latest math models (rigid and flexible body) developed for the MSC/GD Space Shuttle Functional Simulator, are included.

Williams, F. E.↗

Control valve and control valve system for controlling solids flow, methods of manufacture thereof and articles comprising the same

Disclosed herein is a solids flow control valve comprising a standpipe; a shoe; and a transport pipe; wherein the standpipe is in operative communication with the shoe and lies upstream of the shoe; the standpipe comprising a first end and a second end, where the first end is in contact with a source that contains disposable solids and the second end is in fluid contact with the shoe; the shoe being operative to restrict the flow of the disposable solids; the transport pipe being disposed downstream of the shoe to receive and transport the solids from the shoe.

42 ENGINEERING↗

Data-driven predictive probability density function control of fiber length stochastic distribution shaping in refining process

Pulp is the most important raw material in paper in paper industries, whose Fiber Length Stochastic Distribution (FLSD) shaping directly determines the energy consumption and paper quality of the subsequent papermaking processes. However, the mean and variance are insufficient to describe the output FLSD shaping, which display non-Gaussian distribution properties. Therefore, the traditional control, method based on the mean and variance of fiber length is difficult to control the FLSD shaping effectively. In this paper, a novel data-driven predictive probability density function (PDF) control method is proposed for output FLSD shaping in refining process. Primarily, in order to improve the approximation accuracy of the PDF employing RBF neural network, the parameters (center value and width) of each RBF basis functions are tuned via utilizing iterative learning control (ILC) law, and the corresponding estimations of weights law can be obtained. Secondly, considering that the conventional linear model of weights vector has drawbacks of low accuracy and weak generalization ability, random vector functional link networks (RVFLNs) based data driven nonlinear modelling method is employed to characterize the prediction model between the input variables and weights vector. Finally, in order to reduce the randomness of the output FLSD, a minimum entropy control method under mean constraint is employed to design the predictive PDF controller for the output FLSD shaping with the help of the established nonlinear stochastic distribution model. Both simulations and experiments are given to illustrate the effectiveness and practicability of the proposed method.

Probability debsity function, Fiber length distrib↗

Site-Specific Evaluation of Microgrid Controller Using Controller and Power-Hardware-in-the-Loop: Preprint

Microgrids are built by utilities to improve the resilience and reliability of segments of the distribution system. Controllers with advanced capabilities will operate and control these microgrids with diverse energy technologies, which vary from inverter-based photovoltaics, energy storage systems, and ultra-capacitors to conventional diesel generators. There are multiple challenges to building a microgrid controller for a site because of the unique requirements presented by the controllable and uncontrollable elements in the system. There are also challenges to testing the performance of the microgrid controller for such unique microgrids. The research presented here discusses the challenges to evaluating a microgrid controller for a specific site and provides solutions to those challenges. The paper also presents the controller/power-hardware-in-the-loop evaluation platform built to suit the needs of the microgrid as well as the IEEE 2030.8 consistent test cases used to evaluate the proper operation of the microgrid controller. Finally, the paper presents the results from a subset of the experiments performed to evaluate the microgrid controller. a microgrid controller for a site because of the unique requirements presented by the controllable and uncontrollable elements in the system. There are also challenges to testing the performance of the microgrid controller for such unique microgrids. The research presented here discusses the challenges to evaluating a microgrid controller for a specific site and provides solutions to those challenges. The paper also presents the controller/power-hardware-in-the-loop evaluation platform built to suit the needs of the microgrid as well as the IEEE 2030.8 consistent test cases used to evaluate the proper operation of the microgrid controller. Finally, the paper presents the results from a subset of the experiments performed to evaluate the microgrid controller.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evaluation of supply air temperature control performance with different control strategies at air handling units

Due to its nonlinear feature, supply air temperature control systems at air handling units using single-loop fixed gain control frequently suffer unstable response under dynamic conditions. This paper is aimed at identifying a more effective control strategy to stabilize the valve control and achieve desirable supply air temperature response under various operation conditions by evaluating three control strategies, cascade, gain scheduling and cascade plus gain scheduling controls. Firstly, a control-oriented model is developed and calibrated through open-loop tests. Then, the control issues with single-loop fixed gain control are evaluated through simulations and field tests, which indicates that the system has more aggressive response or becomes unstable under lower load conditions when the chilled-water flow rate is less than 0.1 L/s. Finally, three control strategies are proposed and evaluated. Further, the results reveal that all three proposed controls can achieve better robustness with the integral square error of supply air temperature decreased to 16%, 47% and 5%, respectively, under lower load condition. However, since high-frequency oscillation of the control valve occurs with cascade and cascade plus gain scheduling control, the gain scheduling control is recommended considering a trade-off among the supply air temperature response, valve lifetime and implementation complexity.

42 ENGINEERING↗

Transactive Control Design for Commercial Buildings to Provide Demand Response

Transactive coordination and control is a new type of distributed strategy that is designed to engage various self-interested distributed energy resources such as controllable loads, distributed generators, and energy storage for providing demand response. In this paper, a novel transactive control design is proposed for commercial buildings to coordinate the electricity demand of the package rooftop air conditioning units (RTUs) for demand response. Such a coordination is realized by introducing a local relationship between the temperature setpoint and the market clearing price. With the proposed market-based control, the demand of individual RTUs is adjusted by changing their temperature setpoints as a response to the market clearing prices. Two dierent scenarios of demand response are considered herein. One is to limit the peak demand of commercial buildings, in which a new market clearing strategy based on proportionalintegral- derivative control with respect to the demand limit is proposed. The other one is to perform price responsive control, in which the total demand of commercial buildings will respond to the real-time pricing. The proposed transactive strategy is also tested and demonstrated on a real occupied building located at Pacic Northwest National Laboratory. The eld testing results conrm the eectiveness of the proposed transactive coordination and control for commercial building with RTUs to provide demand response.

Huang, Sen↗

Human-in-the-Loop Motion Control of a Two-DOF Hydraulic Backhoe Powered by the Hybrid Hydraulic Electric Architecture (HHEA)

Abstract The Hybrid Hydraulic-Electric Architecture (HHEA) combines the respective power density and control advantages of hydraulic and electric actuation to save energy for off-road vehicles. It uses a set of selectable common pressure rails to transmit the majority of power and electric actuation to modulate that power. As it is critical that off-road vehicles can perform tasks dexterously and exactly as commanded by the operator, the switchings between discrete pressure rails pose a potential challenge for smooth and precise motion. A control strategy consisting of a backstepping nominal control and least norm transition control has previously been developed to address this issue. It has been tested on 1 degree of freedom (DOF) testbeds where known trajectories were able to be tracked precisely. This paper presents the implementation of the HHEA motion control strategy on a 2-DOF backhoe operated by a human operator via a 2-DOF joystick. Unlike previous studies, the duty cycle is unknown beforehand and the decision to change pressure rails is taken in real-time. The efficacy of the motion control strategy has been validated experimentally. Several strategies to improve the user interface: control in workspace coordinates, pressure feedback, and velocity field-based task specification, have also been implemented and demonstrated to make operating the multiple DOF, HHEA actuated machine more intuitive to novice operators.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Software Control Program For Transportable Microgrid State-of-charge Balancing And Frequency Stability Controls

A deterministic state-of-charge (SOC) balancing approach software control code is introduced as an integral secondary management to primary control layer of an islanded small microgrid or nanogrid system made up of multiple grid-forming inverter/battery/solar combination systems, where each set of batteries with each inverter are on independent DC buses (i.e. non-paralleled on the DC sides). A DERMS-level control approach, algorithm and automation controller program was developed to improve coordination and enable microgrid asset compliance and SOC balancing, enabling provision of a system-level power stability support architecture, load support, and asset scalability. The architecture is configured to treat each unit or micro/nano-grid as a node in a microgrid network, allowing for autonomous DERMS control regarding load and SOC balancing and power stability. As the network grows with the addition of units, greater coordination efforts may be required. The ideal small network microgrid ranges from 2-10 inverter/battery units before additional control parameters must be considered in the existing architecture. The control approach focuses on a deterministic state-of-charge analysis as the primary level control process followed by a secondary control loop using a forced frequency-watt droop strategy to conform off-the-shelf components into behaving under a leader-follower configuration. Adopting this control scheme has been shown to allow for a balanced, unit-coordinated microgrid network, enabling stable power flow. The deterministic state-of-charge approach is introduced as an integral primary control layer of an islanded small network microgrid. A standard strategy for SOC balancing is implementing a battery management system (BMS) to control SOC on the DC side. An alternative approach is to determine how to coordinate sending and receiving power on the AC side with multiple units. The latter approach assesses all the integrated units in the microgrid network. Once the individual units are identified, further system data is required to calculate each unit's total kWh, provided information about its capability to supply or consume kWh and availability. The secondary control layer in the multi-layered small network microgrid methodology uses the primary layer’s decision to initiate frequency setpoint changes, initializing the SOC balancing. The secondary control layer considers numerous system-dependent variables to enable a charging and discharging profile based on adjustable frequency setpoints. The combined architecture will result in stable, coordinated power flow enhancing an AC microgrid's functionalities.

Myers, KurtS [Idaho National Laboratory (INL), Ida↗

Feedforward Control of Fuel Distribution on Advanced Dual-Fuel Engines with Varying Intake Valve Closing Timings

This study examines the dynamics and control of an engine operated with late intake valve closure (LIVC) timings in a dual-fuel combustion mode. The engine features a fuel delivery system in which diesel is direct-injected and natural gas is port-injected. Despite the benefits of LIVC and dual-fuel strategy, combining these two techniques resulted in efficiency losses due to the variability of the combustion process across cylinders. The difference in power production across cylinders ranges from 9% at an IVC of 570°ATDC* to 38% at an IVC of 620 °ATDC and indicates an increasingly uneven fuel distribution as the intake valve remains open longer in the compression stroke. This paper describes an approach for controlling the amount of fuel injected into each cylinders’ port of an inline six- cylinder heavy-duty dual-fuel engine to minimize the variations in fuel distribution across cylinder. Since measuring the actual fuel reaching each cylinder is not a practical option on stock engines, this study aimed to produce a feedforward control technique. Using a model developed on an engine simulation software, the optimal fuel injection amounts at each cylinder port across 125 operating conditions (consisting of sweeps of five engine speeds, five engine loads, and five IVC timings) were determined by using PI controllers that adjust the amount of fuel injected at each port based on the amount of fuel reaching the cylinders. The results from the PI controller were expressed as a function of the operating condition (engine speed, engine load, and IVC timing); and consequently, could be reproduced without relying on a measurement of the amount of fuel reaching each cylinder. The feedforward control strategy, unlike the PI controller, is easily implementable on a stock engine and significantly reduces the variations in fuel distribution across cylinders.

Kassa, Mateos↗

An investigation of adaptive controllers for helicopter vibration and the development of a new dual controller

An investigation of the properties important for the design of stochastic adaptive controllers for the higher harmonic control of helicopter vibration is presented. Three different model types are considered for the transfer relationship between the helicopter higher harmonic control input and the vibration output: (1) nonlinear; (2) linear with slow time varying coefficients; and (3) linear with constant coefficients. The stochastic controller formulations and solutions are presented for a dual, cautious, and deterministic controller for both linear and nonlinear transfer models. Extensive simulations are performed with the various models and controllers. It is shown that the cautious adaptive controller can sometimes result in unacceptable vibration control. A new second order dual controller is developed which is shown to modify the cautious adaptive controller by adding numerator and denominator correction terms to the cautious control algorithm. The new dual controller is simulated on a simple single-control vibration example and is found to achieve excellent vibration reduction and significantly improves upon the cautious controller.

Mookerjee, P.↗

Nonlinear rescaling of control values simplifies fuzzy control

Traditional control theory is well-developed mainly for linear control situations. In non-linear cases there is no general method of generating a good control, so we have to rely on the ability of the experts (operators) to control them. If we want to automate their control, we must acquire their knowledge and translate it into a precise control strategy. The experts' knowledge is usually represented in non-numeric terms, namely, in terms of uncertain statements of the type 'if the obstacle is straight ahead, the distance to it is small, and the velocity of the car is medium, press the brakes hard'. Fuzzy control is a methodology that translates such statements into precise formulas for control. The necessary first step of this strategy consists of assigning membership functions to all the terms that the expert uses in his rules (in our sample phrase these words are 'small', 'medium', and 'hard'). The appropriate choice of a membership function can drastically improve the quality of a fuzzy control. In the simplest cases, we can take the functions whose domains have equally spaced endpoints. Because of that, many software packages for fuzzy control are based on this choice of membership functions. This choice is not very efficient in more complicated cases. Therefore, methods have been developed that use neural networks or generic algorithms to 'tune' membership functions. But this tuning takes lots of time (for example, several thousands iterations are typical for neural networks). In some cases there are evident physical reasons why equally space domains do not work: e.g., if the control variable u is always positive (i.e., if we control temperature in a reactor), then negative values (that are generated by equal spacing) simply make no sense. In this case it sounds reasonable to choose another scale u' = f(u) to represent u, so that equal spacing will work fine for u'. In the present paper we formulate the problem of finding the best rescaling function, solve this problem, and show (on a real-life example) that after an optimal rescaling, the un-tuned fuzzy control can be as good as the best state-of-art traditional non-linear controls.

Vanlangingham, H.↗

Multi-application controls: Robust nonlinear multivariable aerospace controls applications

This viewgraph presentation describes the general methodology used to apply Honywell's Multi-Application Control (MACH) and the specific application to the F-18 High Angle-of-Attack Research Vehicle (HARV) including piloted simulation handling qualities evaluation. The general steps include insertion of modeling data for geometry and mass properties, aerodynamics, propulsion data and assumptions, requirements and specifications, e.g. definition of control variables, handling qualities, stability margins and statements for bandwidth, control power, priorities, position and rate limits. The specific steps include choice of independent variables for least squares fits to aerodynamic and propulsion data, modifications to the management of the controls with regard to integrator windup and actuation limiting and priorities, e.g. pitch priority over roll, and command limiting to prevent departures and/or undesirable inertial coupling or inability to recover to a stable trim condition. The HARV control problem is characterized by significant nonlinearities and multivariable interactions in the low speed, high angle-of-attack, high angular rate flight regime. Systematic approaches to the control of vehicle motions modeled with coupled nonlinear equations of motion have been developed. This paper will discuss the dynamic inversion approach which explicity accounts for nonlinearities in the control design. Multiple control effectors (including aerodynamic control surfaces and thrust vectoring control) and sensors are used to control the motions of the vehicles in several degrees-of-freedom. Several maneuvers will be used to illustrate performance of MACH in the high angle-of-attack flight regime. Analytical methods for assessing the robust performance of the multivariable control system in the presence of math modeling uncertainty, disturbances, and commands have reached a high level of maturity. The structured singular value (mu) frequency response methodology is presented as a method for analyzing robust performance and the mu-synthesis method will be presented as a method for synthesizing a robust control system. The paper concludes with the author's expectations regarding future applications of robust nonlinear multivariable controls.

Enns, Dale F.↗

Development of a Model Following Control Law for Inflight Simulation and Flight Controls Research

The U.S. Army and NASA are currently developing the Rotorcraft Aircrew Systems Concepts Airborne Laboratory (RASCAL) at the Ames Research Center. RASCAL, shown in Figure 1, is a UH-60, which is being modified in a phased development program to have a research fly-by-wire flight control system, and an advanced navigation research platform. An important part of the flight controls and handling qualities research on RASCAL will be an FCS design for the aircraft to achieve high bandwidth control responses and disturbance rejection characteristics. Initially, body states will be used as feedbacks, but research into the use of rotor states will also be considered in later stages to maximize agility and maneuverability. In addition to supporting flight controls research, this FCS design will serve as the inflight simulation control law to support basic handling qualities, guidance, and displays research. Research in high bandwidth controls laws is motivated by the desire to improve the handling qualities in aggressive maneuvering and in severely degraded weather conditions. Naturally, these advantages will also improve the quality of the model following, thereby improving the inflight simulation capabilities of the research vehicle. High bandwidth in the control laws provides tighter tracking allowing for higher response bandwidths which can meet handling qualities requirements for aggressive maneuvering. System sensitivity is also reduced preventing variations in the response from the vehicle due to changing flight conditions. In addition, improved gust rejection will result from this reduced sensitivity. The gust rejection coupled with a highly stable system will make more precise maneuvering and pointing possible in severely degraded weather conditions. The difficulty in achieving higher bandwidths from the control laws in the feedback and in the responses arises from the complexity of the models that are needed to produce a satisfactory design. In this case, high quality models that include rotor dynamics in a physically meaningful context must be available. A non-physical accounting of the rotor, such as lumping the effect as a time delay, is not likely to produce the desired results. High order simulation models based on first principals are satisfactory for the initial design phase in order to work out the control law design concept and get an initial set of gains. These models, however, have known deficiencies, which must be resolved in the final control law design. The error in the pitch-roll cross coupling is one notable deficiency that even sophisticated rotorcraft models including complex wake aerodynamics have yet to capture successfully. This error must be accounted for to achieve the desired decoupling. The approach to design the proposed inflight simulation control law is based on using a combination of simulation and identified models. The linear and nonlinear higher order models were used to develop an explicit model following control structure. This structure was developed to accommodate the design of control laws compliant to many of the quantitative requirements in ADS-33C. Furthermore, it also allows for control law research using rotor-state feedback and other design methodologies such as Quantitative Feedback and H-Infinity. Final gain selection will be based on higher order identified models which include rotor degrees of freedom.

Takahashi, Mark↗

Comparison of Virtual Oscillator and Droop Control: Preprint

Virtual oscillator control and droop control are two techniques that can be used to ensure synchronization and power sharing of parallel inverters in islanded operation. VOC relies on the implementation of non-linear Van der Pol oscillator equations in the control system of the inverter, acting upon the time-domain instantaneous inverter current and terminal voltage. On the other hand, DC explicitly computes active and reactive power produced by the inverter and relies on limited bandwidth low-pass filters. Even though both methods can be engineered to produce the same steady-state characteristics, their dynamic performances are significantly different. This paper presents analytical and experimental results that aim to compare both methods. It is shown that VOC is inherently faster and enables minimizing the circulating currents. The results are verified using three 120V, 1kW inverters.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Integrated Synchronization Control of Grid-Forming Inverters for Smooth Microgrid Transition

This paper develops an integrated synchronization control technique for a grid-forming inverter operating within a microgrid that can improve the microgrid's transients during microgrid transition operation. This integrated synchronization control includes the disconnection synchronization control and the reconnection synchronization control. The simulation results show that the developed synchronization control works effectively to smooth the angle change of the grid-forming inverter during microgrid transition operation. Thus, the microgrid's transients are significantly improved compared to the case without synchronization control.

control↗

Data-Driven Chance-Constrained Design of Voltage Droop Control for Distribution Networks: Preprint

This paper addresses the design of local control methods for voltage control in distribution networks with high level of distributed energy resources (DERs). The designed control methods adapt the active and reactive power output of distributed energy resources proportional to the deviation of the local measured voltage magnitudes from a reference voltage, which is referred to as droop control. Thus, the design focuses on determining the droop characteristics which satisfy network-wide voltage magnitude constraints. The uncertainty and variability of DERs renders the design of optimal droop controls very challenging. Hence, this paper proposes chance constraints to limit the risk from intermittent DERs, by designing droop control coefficients that guarantee the satisfaction of network operational constraints with a specific probability. In addition, the proposed approach relies entirely on historical data rather than assuming knowledge of the probability distributions that characterize the uncertainty of DERs. The efficacy of the proposed method is demonstrated on a 37-bus distribution feeder.

chance-constrained optimization↗

Active Power Control of Wind Turbines for Ancillary Services: A Comparison of Pitch and Torque Control Methodologies

As wind energy generation becomes more prevalent in some regions, there is increased demand for wind power plants to provide ancillary services, which are essential for grid reliability. This paper compares two different wind turbine control methodologies to provide active power control (APC) ancillary services, which include derating or curtailing power generation, providing automatic generation control (AGC), and providing primary frequency control (PFC). The torque APC controller provides all power control through the power electronics whereas the pitch APC controller uses the blade pitch actuators as the primary means of power control. These controllers are simulated under various wind conditions with different derating set points and AGC participation levels. The metrics used to compare their performance are the damage equivalent loads (DELs) induced on the structural components and AGC performance metrics, which are used to determine the payments for AGC services by system operators in the United States. The simulation results show that derating the turbine reduces structural loads for both control methods, with the APC pitch control providing larger reductions in DELs, lower AGC performance scores, and higher root-mean-square pitch rates. Providing AGC increases the structural loads when compared to only derating the turbine, but even the AGC DELs are generally lower than those of the baseline control system. The torque APC control methodology also allows for more sustained PFC responses under certain derating conditions.

17 WIND ENERGY↗