Search NASA⌕ Search

SEARCH · Search NASA

Results for “converter control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Interleaved Cuk Converter Wave Energy System With Advanced Control and Grid Support Functions for Seamless Integration

This paper presents an innovative wave energy conversion system that integrates an interleaved Cuk converter with advanced nonlinear control for seamless grid integration. The system efficiently extracts power on the DC side using the interleaved Cuk converter, while an inverter manages power transfer to the grid or load on the AC side. A nonlinear control architecture, based on the Lyapunov energy function, ensures stable and optimal operation under varying wave conditions, effectively addressing the challenges of variability and unpredictability inherent in wave energy. The proposed system also incorporates features to enhance power quality and minimize losses, making it a robust solution for renewable energy integration. The system's effectiveness in harnessing wave energy and achieving smooth grid integration is validated through comprehensive computer simulations in MATLAB/Simulink, with case study results demonstrating its capabilities.

HYDRO ENERGY,TIDAL AND WAVE POWER↗

Medium Voltage Solid State Transformer for Extreme Fast Charging Applications

A modular and scalable solid state transformer (SST) with direct medium voltage (MV) AC connectivity is proposed to enable DC extreme fast charging (XFC) of electric vehicles. Single-phase-modules (SPMs), each consisting of an active-front-end (AFE) stage and an isolated DC-DC stage, are connected in input-series-output-parallel (ISOP) configuration. The modular hardware is co-designed with decentralized control of the DC-DC stages where voltage and power balancing are achieved by each SPM using only its local sensor feedback; a centralized controller (CC) regulates the low voltage (LV) DC bus through the AFE stages without any sensor feedback form the SPMs. The controller architecture contrasts sharply with the prior art for MV AC to LV DC SSTs where high-speed bidirectional communication among SPMs and a CC are required for module-level voltage and power balancing, which severely limits the scalability and practical realization of higher voltage and higher power units. Detailed small-signal analysis and controller design guidelines are developed. Furthermore, a soft start-up strategy is presented. The proposed converter and control structure are validated through simulation and experimental results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Multi-resonant switched capacitor power converter architecture

A switched-capacitor (SC) network in an SC converter is controlled to operate at varying resonant modes to achieve high conversion ratio efficiency, at a low circuit component count. These power converters are suited to numerous application areas including improving energy efficiency of data centers. A family of resonant switched capacitor (SC) converters with multiple operating phases are presented “Multi-Resonant SC Converters”. Described in detail are an 8-to-1 Multi-Resonant-Doubler (MRD) converter and a 6-to-1 Cascaded Series-Parallel (CaSP). The topology of these converters make them amenable to combining like units in parallel toward reaching higher power levels.

Ye, Zichao↗

Comparative Evaluation of the Single-Phase Shift and Extended-Phase Shift Control for Isolated DC-DC Converter

Abstract: This paper presents a comparative evaluation of the Single-Phase Shift (SPS) and Extended-Phase Shift (EPS) controls for the isolated DC-DC Converter. The analysis is based on the power regulation range, flexibility of operation, current stress on power devices, system efficiency while focusing on the issue of backflow power, control complexity, design and implementation overhead, and stability of the entire system. It is also examined how the backflow influences power circulation and increases current stress. Here, the Dual Active Bridge (DAB) Converter is employed to assess the performance of the control methods. Compared to SPS control, EPS offers a wider power regulation range, greater flexibility, lower current stress, and better system efficiency. However, EPS has increased control complexity, design and implementation overhead, and often requires sophisticated feedback control loops. The comparison is made through mathematical modeling of power transfer, backflow, and current stress. Simulation results validate the comparative analysis presented.

Amir, Aamir [The University of Alabama (UA)]↗

On the Low Risk of SSR in Type III Wind Turbines Operating with Grid-Forming Control

We have shown in previous work that the risk of subsynchronous resonance between wind power plants with Type III wind turbines and series-compensated transmission lines is low when the wind turbines are operated in grid-forming (GFM) mode instead of the standard grid-following mode. This paper explains the fundamental mechanism behind the improved damping characteristics by modeling the positive- and negative-sequence impedances of Type III wind turbines in GFM control mode. Here it is discovered that the GFM control naturally acts against the negative resistance behavior of Type III wind turbines at subsynchronous frequencies that results from an interaction between the rotor-side converter current controller and negative slip. The developed impedance models in the sequence domain and the improved damping behavior are verified using PSCAD simulations of a 2.5-MW Type III GFM wind turbine. The modeling predictions are also supported by experimentally measuring the impedance response of a 2.5-MW Type III wind turbine in GFM mode.

17 WIND ENERGY↗

On the Low Risk of Subsynchronous Resonance (SSR) in Type III Wind Turbines Operating in Grid-Forming Control

We have shown in a previous work that the risk of sub-synchronous resonance (SSR) between a wind power plant with Type III wind turbines and series-compensated transmission lines is low when the wind turbines in the plant are operated in grid-forming mode, instead of the standard grid-following mode. The fundamental mechanism behind the improved damping characteristics is explained in this paper by modeling the positive and negative sequence impedances of Type III wind turbines for GFM operation mode. It is discovered that the GFM control naturally acts against the negative resistance of Type III wind turbines that results from an interaction between the proportional gain of the rotor-side converter current controller and negative slip. The developed sequence impedance models and improved damping behavior are verified using PSCAD simulations of a 2.5-MW Type III GFM wind turbine. The modeling predictions are also supported by experimentally measuring the sequence impedance response of a 2.5-MW Type III wind turbine during operation in GFL and GFM modes.

grid-following turbine↗

Nonlinear hydrostatic control of a wave energy converter

Increased energy harvesting is realized using a nonlinear buoy geometry for reactive power generation. By exploiting the nonlinear dynamic coupling between the buoy geometry and the potential wideband frequency spectrum of incoming waves in the controller/buoy design, increased power can be captured in comparison to conventional wave energy converter designs. In particular, the reactive power and energy storage system requirements are inherently embedded in the nonlinear buoy geometry, therefore requiring only simple rate-feedback control.

Wilson, David G.↗

Control and Management of Multiple Converters in a Residential Smart Grid

Power electronic systems are becoming a staple building block for electric grid networks. However, these systems have been largely designed to grid integrate in ad hoc configurations with little or no coordination of control. This work proposes a central controller and power electronic system hardware and software design for a residential system (photovoltaic, energy storage and residential building). This system supports auto-integration, plug and play capabilities, and optimal energy management to meet different use cases. Modelling and multi-day testing of the system have been conducted in a controller hardware-in-the-loop (C-HIL) testbed. Multiple use cases and pricing options have been considered as part of the simulation and testing. Results are presented of these systems as a proof of principle.

Starke, Michael↗

Direct Power Control of Back to Back Modular Multilevel Converter with Advanced Grid Support Functions for Grid Forming Application

Possibility of using back-to-back modular multilevel converter system with a direct power control architecture has been investigated in this paper. The rectifier side is controlled to be in grid following mode whereas the inverter side is controlled in grid forming mode. Both the sides’ local controllers use Lyapunov energy function based architecture to accomplish the objective of active and reactive power control as well as maintaining a fixed user defined voltage over the dc bus on the rectifier side. Therefore, the proposed direct power control architecture has embedded dc bus control architecture to maintain fixed user defined value of the capacitors. Similar architecture is implemented on the inverter side to accomplish either voltage control during grid forming or power control during grid following. Advanced grid support functionalities based on IEEE-1547-2018 is implemented and utilized to generate the reference values for either the rectifier or the inverter sides. The overall system is modeled based on MATLAB/Simulink and PLECS domain and various important case studies to verify the efficacy of the overall system has been presented.

direct power control (DPC)↗

Method and apparatus for evaluating superconducting tunnel junction detector noise versus bias voltage

A technique for characterizing the noise behavior of a superconducting tunnel junction (STJ) detector as a function of its applied bias voltage Vb by stepping the STJ's bias voltage across a predetermined range and, at each applied bias, making multiple measurements of the detector's current, calculating their mean and their standard deviation from their mean, and using this standard deviation as a measure of the STJ detector's noise at that applied bias. Because the method is readily executed under computer control, it is particularly useful when large numbers of STJ detectors require biasing, as in STJ detector arrays In a preferred implementation, the STJ is measured under computer control by attaching it to a digital spectrometer comprising a digital x-ray processor (DXP) coupled to a preamplifier that can set the STJ's bias voltage Vb using a digital-to-analog converter (DAC) controlled by the DXP.

Warburton, William K.↗

2.1.2.403 - Fatigue and Structural Load Analysis and Control for Variable-Geometry Wave Energy Converters (VGWECs)

The VGWEC project will generate and disseminate the foundational knowledge enabling a paradigm shift in the design of wave energy converters (WECs) by adding a geometry control option on top of power-take-off load control. The variable-geometry modules (VGMs) provide control over a WEC's hydrodynamics that can emphasize power absorption or load shedding. Additional load shedding provided by the VGMs is expected to reduce the device structural mass and extend the sea state operating envelope, by limiting peak loading, both contributing towards reducing levelized cost of energy (LCOE) estimates.

hydrodynamic↗

Open Circuit Switch Fault Management Method of a Multi-Phase Synchronous Buck Converter for EV Charging Application

Multi-phase synchronous buck converter (MSBC) is becoming popular for the electric vehicle (EV) charging application because of its higher efficiency, smaller passive component sizes, bidirectional power flow, and output current ripple reduction through interleaving. This converter also provides higher reliability than the traditional single phase converter since its modular structure enables fault tolerant operation. Fault management in the converter requires the detection of switch fault, shut down of the faulty phase, and reconfiguration of the PWM signals for the healthy phases to avoid circulating current and high output current ripple. In addition, it is desirable that the fault management method can be implemented using the micro-controller unit (MCU) or digital signal processor (DSP), which are widely used to control power converters. This paper presents a fault management method for detecting switch faults and reconfiguring healthy phases using a DSP. The method is validated through simulations and experiments using a commercial off-the-shelf power stack.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Generic Multivector Model Predictive Control With Symmetric Pulse Pattern for Hybrid Multilevel Converters

This article presents a generic multivector model predictive control (MV-MPC) method that has the potential to be applied to all hybrid multilevel converters (HMCs). It first locates the reference voltage vector in the 120° oblique coordinate to select the three adjacent voltage vectors to be applied over one control cycle. Then, the current tracking is guaranteed through duty cycle optimization and dc capacitor voltages are balanced by evaluating possible switching sequences that belong to the voltage vectors with optimal duty cycles. At last, the optimal switching sequence with a symmetric five- or seven-segment pulse pattern is generated using an external modulator. Here, the proposed generic MV-MPC can significantly improve the quality of the output current, while achieving a constant equivalent switching frequency at the same time. Experimental studies on an all silicon carbide HMC prototype, i.e., an active neutral point clamped converter with cascaded H-bridge, are presented to validate the effectiveness of the proposed MV-MPC strategy.

42 ENGINEERING↗

Adaptive Reinforcement Learning (ARL) Control of a Multi-port Resonant Converter in UAV Systems

This study presents an adaptive reinforcement learning (ARL) control framework for a multi-port resonant converter used in hybrid unmanned aerial vehicle (UAV) power systems. The converter integrates high-frequency half-bridge input ports connected to a rectified engine–generator set and a battery energy storage system, along with a semi-bridgeless active rectifier supplying the propulsion load. A deep RL agent is trained to dynamically regulate inter-port phase-shift commands in real time based on flight conditions and load power demand. The ARL controller autonomously identifies phase-shift combinations that maximize conversion efficiency while maintaining stable and coordinated power flow, even under rapidly varying operating scenarios. This data-driven approach eliminates the need for explicit system modeling or extensive manual tuning and enables coordinated control among multiple power ports without inter-port communication. Experimental results validate that the ARL based strategy achieves reliable power sharing and consistently high-efficiency operation across diverse UAV operating conditions.

Asa, Erdem [ORNL] (ORCID:0000000190884812)↗

Guest Editorial Special Section on Advanced Medium-Voltage Power Electronics for Grid Interactive Applications

Medium-voltage power electronics (MVPE) plays essential roles in power grid modernization and links the MV distribution grid with low-voltage consumers and prosumers. Various MVPE devices, such as solid-state transformers or circuit breakers, inverter-based resources, power flow controllers, etc., bring the benefits of voltage conversion and power regulation in small footprint, power quality and efficiency improvements, and enhancements of grid controllability, flexibility, stability, and resilience. The MVPE also makes it possible for sustainable energy systems, such as solar/wind farms and energy storage generating facilities, to directly access to MV grids without multistage conversions. With their intrinsic intelligence and communications, MVPE enables many new smart grid functions and applications, e.g., dc interconnections and electric vehicle charging, which were not envisioned by traditional power grids otherwise. In addition, the integration of physical power processing units with cyber components forms a cyber-physical system, which is essential for long-term sustainability, development, and environmental preservation. Nonetheless, technical challenges on MVPE device reliability, scalable and efficient converter topologies, control stability, large-scale modeling and simulation, to name a few, need to be addressed and advanced to the next level. In conclusion, this Special Section on Advanced MV Power Electronics for Grid Interactive Applications in IEEE Transactions on Power Electronics (TPEL) provides an insight on some of the recent advances in MVPE and emerging challenges and potential solutions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Paralleling of LLC Resonant Converters

The LLC resonant converter is a popular, variable switching frequency DC-DC converter that may be controlled using two methods: charge and frequency control. In this paper, the application of LLC resonant converters to input-parallel, output-parallel system is studied. In this respect, the models of output-port I-V characteristics and small-signal output impedance of the charge controlled LLC converter are proposed. In addition, a mathematical framework is developed for droop-based paralleled DC-DC systems. Here, it distinctly identifies the output DC voltage and circulating current modes of stability, even in systems comprising of non-identical converters.

42 ENGINEERING↗

Passivity-Based Control of Grid Forming and Grid Following Converters in Microgrids

With the integration of more and more power electronics devices into the grid, it is not easy to guarantee the stability of the whole system due to the complexity of the control structure of various power converters. In this paper, we consider grid-forming and grid-following converters in one microgrid, in which the grid-forming converters support the voltage and frequency of the microgrid and the grid-following converters inject their maximum power into the microgrid. To handle the stability issue, the passivity principle is applied to guarantee the stability of the whole microgrid. We ensure every grid-following converter satisfies the passivity via the port-controlled Hamiltonian method. In addition, we apply the passivity-based proportional-resonant controller to the grid-forming converter. One of the advantages of the proposed method is that the phase lock loop system is eliminated, which may cause stability issues. Simulation results show that the proposed method can control the microgrid effectively.

Gui, Yonghao (Young)↗

Duty-Cycle Predictive Control of Quasi-Z-Source Modular Cascaded Converter Based Photovoltaic Power System

A duty-cycle predictive control is proposed for dc grid integration of front-end isolated quasi-Z-source modular cascaded converter (qZS-MCC) photovoltaic (PV) power system. The post-stage qZS half-bridge dc-dc converter deals with PV maximum power point tracking, dc grid integration, and dc-link voltage balance; whereas, the front-end isolation converters operate at a constant duty cycle of 50%. Thus, it saves control hardware resources while overcoming challenges from PV-panel voltage variations and dc-bus voltage limit. The proposed control uses the derived circuit model to predict the global active-state duty cycle for grid-connected current control and predict the shoot-through duty cycles for dc-link voltage balance, achieving a fast and accurate tracking target. The proposed control method has advantages of: i) eliminating weighting factors that exist in conventional model predictive control (MPC), ii) no sophisticated loop parameters design that exists in proportional-integral (PI) control, iii) operating at constant switching frequency that is different from the conventional MPC with variable switching frequency. Simulation and experimental tests are carried out to verify the effectiveness of the proposed control method and compare with the PI-based control system.

42 ENGINEERING↗