Search NASA⌕ Search

SEARCH · Search NASA

Results for “cooling center”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Manufacturing in space: Fluid dynamics numerical analysis

Natural convection in a spherical container with cooling at the center was numerically simulated using the Lockheed-developed General Interpolants Method (GIM) numerical fluid dynamic computer program. The numerical analysis was simplified by assuming axisymmetric flow in the spherical container, with the symmetry axis being a sphere diagonal parallel to the gravity vector. This axisymmetric spherical geometry was intended as an idealization of the proposed Lal/Kroes growing experiments to be performed on board Spacelab. Results were obtained for a range of Rayleigh numbers from 25 to 10,000. For a temperature difference of 10 C from the cooling sting at the center to the container surface, and a gravitional loading of 0.000001 g a computed maximum fluid velocity of about 2.4 x 0.00001 cm/sec was reached after about 250 sec. The computed velocities were found to be approximately proportional to the Rayleigh number over the range of Rayleigh numbers investigated.

Robertson, S. J.↗

Thermal stress analysis of space shuttle orbiter wing skin panel and thermal protection system

Preflight thermal stress analysis of the space shuttle orbiter wing skin panel and the thermal protection system (TPS) was performed. The heated skin panel analyzed was rectangular in shape and contained a small square cool region at its center. The wing skin immediately outside the cool region was found to be close to the state of elastic instability in the chordwise direction based on the conservative temperature distribution. The wing skin was found to be quite stable in the spanwise direction. The potential wing skin thermal instability was not severe enough to tear apart the strain isolation pad (SIP) layer. Also, the preflight thermal stress analysis was performed on the TPS tile under the most severe temperature gradient during the simulated reentry heating. The tensile thermal stress induced in the TPS tile was found to be much lower than the tensile strength of the TPS material. The thermal bending of the TPS tile was not severe enough to cause tearing of the SIP layer.

Ko, William L.↗

Experimental evaluation of catalytic combustion with heat removal at near stoichiometric conditions

Two concentric tube configurations were tested. Tests were conducted at an inlet pressure of 150,000 Pa, inlet fuel air mixture temperatures from 780 to 960 K, combustion air flow rates from 0.78 to 1.5 g/s, equivalence ratios up to 0.90, and a range of cooling air flow rates. Propane and propylene fuels were used. Both configurations used air flowing through the center tube for cooling and combustion in the annulus on the catalytic surface. One configuration had the catalyst applied to the outside surface of the inner tube. Conversion of the fuel was very low for this configuration. The other configuration had the catalyst applied to the inside surface of the outer tube. Conversion of the fuel was considerably better in this configuration.

Bulzan, D. L.↗

A review of challenges, barriers, and opportunities for large-scale deployment of cool surfaces

Major urban centers are warming due to a combination of global and local phenomena. City governments are increasingly adopting strategies to mitigate the causes and impacts of extreme heat on their populations. Among these strategies are high solar-reflectance (cool) surfaces installed on building roofs and walls. Use of cool surfaces is a cost-effective and simple strategy that replaces conventional darker surfaces with surfaces that have a high reflectance to shortwave (solar) energy. This report reviews the recent history of cool-surface deployment efforts. This includes peer-reviewed literature, conference proceedings, and grey literature to identify challenges and barriers to wide-scale deployment of cool surfaces. We have also researched heat action plans and programs from cities and different codes and standards, as well as available incentive and rebate programs. The review identifies challenges, barriers, and opportunities associated with large-scale deployment of cool surfaces and categorize them broadly as being related to product development & performance or policies & mandates. It provides a foundation upon which we intend to build a roadmap for rapidly accelerating future deployments of cool surfaces. Finally, this roadmap will address identified challenges and incorporate lessons learned from historical efforts to generate a practical and actionable plan.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Prototype energy models for data centers

Data centers in the United States consume about two percent of the nation’s electricity. Because heat gains from IT equipment drive cooling demand, data centers offer unique opportunities for energy savings. However, no prototype energy model for data centers is available in the suite of existing U.S. Department of Energy’s Commercial Prototype Building Models. Here we present the development of two new data center prototype models and their implementation in OpenStudio and EnergyPlus. The small-size data center model represents a computer room in a building served by computer room air conditioners (CRACs); while the large-sized model represents stand-alone data centers served by computer room air handlers (CRAHs) with a central chiller plant. For each data center model, two levels of IT equipment (ITE) load density were considered, to cover the wide range of IT power density of data centers: 40 and 100 W/ft 2 (430 and 1076 W/m 2 ) for the computer room, and 100 and 500 W/ft 2 (1076 and 5382 W/m 2 ) for the stand-alone data center. All other assumptions, such as building envelope, lighting, HVAC efficiencies and schedules, were based on the minimal requirements of ASHRAE Standard 90.1 at various vintages. We introduced a novel concept of supply and return air approach temperatures to capture the essential effects of non-uniform airflow and temperature distribution in data centers. The approach temperatures were pre-computed by computational fluid dynamics (CFD) simulations for various configurations of ITE loads and airflow containment management in data centers. A new feature was developed in EnergyPlus to implement the approach temperature method. A case study was conducted to demonstrate the use of the data center models. The two data center models cover all U.S. climate zones and can be used to evaluate energy saving measures for data centers, as well as to support development of data center energy efficiency codes and standards.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Installation of Direct Water-Cooling Systems to Reduce Cooling Energy Requirements for High-Performance Computing Centers

A large cluster of High-Performance Computing (HPC) equipment at the Lawrence Livermore National Laboratory in California was retrofitted with an Asetek cooling system. The Asetek system is a hybrid scheme with water-cooled cold plates on high-heat-producing components in the information technology (IT) equipment, and with the remainder of the heat being removed by conventional air-cooling systems. In order to determine energy savings of the Asetek system, data were gathered and analyzed two ways: using top-down statistical models, and bottom-up engineering models. The cluster, “Cabernet”, rejected its heat into a facilities cooling water loop which in turn rejected the heat into the same chilled water system serving the computer-room air handlers (CRAHs) that provided the air-based cooling for the room. Because the “before” and “after” cases both reject their heat into the chilled water system, the only savings is due to reduction in CRAH fan power. The top-down analysis showed a 4% overall energy savings for the data center (power usage effectiveness (PUE) —the ratio of total data center energy to IT energy— dropped from 1.60 to 1.53, lower is better); the bottom-up analysis showed a 3% overall energy savings (PUE from 1.70 to 1.66) and an 11% savings for the Cabernet system by itself (partial PUE of 1.51). Greater savings, on the order of 15-20%, would be possible if the chilled water system was not used for rejecting the heat from the Asetek system. About 37% of the heat from the Cab system was rejected to the cooling water, lower than at other installations.

Earni, Shankar↗

Tool for Forecasting Cool-Season Peak Winds Across Kennedy Space Center and Cape Canaveral Air Force Station (CCAFS)

Peak wind speed is important element in 24-Hour and Weekly Planning Forecasts issued by 45th Weather Squadron (45 WS). Forecasts issued for planning operations at KSC/CCAFS. 45 WS wind advisories issued for wind gusts greater than or equal to 25 kt. 35 kt and 50 kt from surface to 300 ft. AMU developed cool-season (Oct - Apr) tool to help 45 WS forecast: daily peak wind speed, 5-minute average speed at time of peak wind, and probability peak speed greater than or equal to 25 kt, 35 kt, 50 kt. AMU tool also forecasts daily average wind speed from 30 ft to 60 ft. Phase I and II tools delivered as a Microsoft Excel graphical user interface (GUI). Phase II tool also delivered as Meteorological Interactive Data Display System (MIDDS) GUI. Phase I and II forecast methods were compared to climatology, 45 WS wind advisories and North American Mesoscale model (MesoNAM) forecasts in a verification data set.

Barrett, Joe H., III↗

Electron scattering and the distances to cluster cooling flows

Cluster cooling flows have electron-scattering optical depths which are estimated to be about 0.01. Many of the cluster-dominant galaxies centered in cluster cooling flows have active nuclei, and about 1 percent of the luminosity from the active nuclei should appear as diffuse, scattered radiation. It is shown here that detection of this scattered radiation at radio wavelengths can provide a measure of the distance to the cluster that is independent of the Hubble constant. Observations of the scattered surface brightness profile can also be used to test for clumpiness in the gas, for variations in the central radio source on time scales less than 100,000 yr, and for the degree of beaming of radiation from the central source.

Wise, Michael W.↗

The filaments of NGC 1275 - A collision between a galaxy and an accretion flow?

Morphological evidence is presented (in the form of 3-A-bandpass Fabry-Perot images made with a CCD camera) that the two bright emission-line systems seen toward the galaxy NGC 1275 arise from a high-velocity impact of a foreground galaxy upon the accretion flow of gas cooling in the center of the Perseus cluster. The uniquely high optical-line luminosity of NGC 1275, in comparison with other central galaxies in clusters observed to have cooling flows, may be explained by energy deposited during the collision. Using additional information from 21-cm and extinction measurements, a rough model of the interaction is developed. Problems remain with this model - such as the likelihood of a gas-rich system penetrating to the cluster center. The kinematic structure of the optically emitting gas shows additional complex structure near the nucleus of NGC 1275.

Kaaret, P.↗

X-ray spectra of clusters of galaxies

The X-ray emission from luminous clusters of galaxies is dominated by thermal bremsstrahlung from an intergalactic medium. The central density of the gas is strongly correlated with the X-ray surface brightness. The X-ray surface brightness S(sigma) of many clusters is well modeled by a law of the form S(sigma) alpha S(o) 1 + R(2)/A(2) to the minus 3 beta + 1/2 power with beta approximately equal to 0.66. However, this model does not fit the X-ray spectral or optical galaxy counts well. In clusters with cooling flows in their center there is a strong correlation between the cooling rates of X-ray emitting material and optical H alpha emission. It is not clear, at present, what percentage of the virial mass of the cluster is in hot gas but if beta = 0.66, it is possible for the values to be of the order of 1/2. Spatially resoled X-ray spectroscopy is necessary to determine this value with any accuracy.

Mushotzky, R. F.↗

A Massive, Cooling-Flow-Induced Starburst in the Core of a Highly Luminous Galaxy Cluster

In the cores of some galaxy clusters the hot intracluster plasma is dense enough that it should cool radiatively in the cluster s lifetime, leading to continuous "cooling flows" of gas sinking towards the cluster center, yet no such cooling flow has been observed. The low observed star formation rates and cool gas masses for these "cool core" clusters suggest that much of the cooling must be offset by astrophysical feedback to prevent the formation of a runaway cooling flow. Here we report X-ray, optical, and infrared observations of the galaxy cluster SPT-CLJ2344-4243 at z = 0.596. These observations reveal an exceptionally luminous (L(sub 2-10 keV) = 8.2 10(exp 45) erg/s) galaxy cluster which hosts an extremely strong cooling flow (M(sub cool) = 3820 +/- 530 Stellar Mass/yr). Further, the central galaxy in this cluster appears to be experiencing a massive starburst (740 +/- 160 Stellar Mass/ yr), which suggests that the feedback source responsible for preventing runaway cooling in nearby cool core clusters may not yet be fully established in SPT-CLJ2344-4243. This large star formation rate implies that a significant fraction of the stars in the central galaxy of this cluster may form via accretion of the intracluster medium, rather than the current picture of central galaxies assembling entirely via mergers.

McDonald, M.↗

Tool for Forecasting Cool-Season Peak Winds Across Kennedy Space Center and Cape Canaveral Air Force Station

The expected peak wind speed for the day is an important element in the daily morning forecast for ground and space launch operations at Kennedy Space Center (KSC) and Cape Canaveral Air Force Station (CCAFS). The 45th Weather Squadron (45 WS) must issue forecast advisories for KSC/CCAFS when they expect peak gusts for >= 25, >= 35, and >= 50 kt thresholds at any level from the surface to 300 ft. In Phase I of this task, the 45 WS tasked the Applied Meteorology Unit (AMU) to develop a cool-season (October - April) tool to help forecast the non-convective peak wind from the surface to 300 ft at KSC/CCAFS. During the warm season, these wind speeds are rarely exceeded except during convective winds or under the influence of tropical cyclones, for which other techniques are already in use. The tool used single and multiple linear regression equations to predict the peak wind from the morning sounding. The forecaster manually entered several observed sounding parameters into a Microsoft Excel graphical user interface (GUI), and then the tool displayed the forecast peak wind speed, average wind speed at the time of the peak wind, the timing of the peak wind and the probability the peak wind will meet or exceed 35, 50 and 60 kt. The 45 WS customers later dropped the requirement for >= 60 kt wind warnings. During Phase II of this task, the AMU expanded the period of record (POR) by six years to increase the number of observations used to create the forecast equations. A large number of possible predictors were evaluated from archived soundings, including inversion depth and strength, low-level wind shear, mixing height, temperature lapse rate and winds from the surface to 3000 ft. Each day in the POR was stratified in a number of ways, such as by low-level wind direction, synoptic weather pattern, precipitation and Bulk Richardson number. The most accurate Phase II equations were then selected for an independent verification. The Phase I and II forecast methods were compared using an independent verification data set. The two methods were compared to climatology, wind warnings and advisories issued by the 45 WS, and North American Mesoscale (NAM) model (MesoNAM) forecast winds. The performance of the Phase I and II methods were similar with respect to mean absolute error. Since the Phase I data were not stratified by precipitation, this method's peak wind forecasts had a large negative bias on days with precipitation and a small positive bias on days with no precipitation. Overall, the climatology methods performed the worst while the MesoNAM performed the best. Since the MesoNAM winds were the most accurate in the comparison, the final version of the tool was based on the MesoNAM winds. The probability the peak wind will meet or exceed the warning thresholds were based on the one standard deviation error bars from the linear regression. For example, the linear regression might forecast the most likely peak speed to be 35 kt and the error bars used to calculate that the probability of >= 25 kt = 76%, the probability of >= 35 kt = 50%, and the probability of >= 50 kt = 19%. The authors have not seen this application of linear regression error bars in any other meteorological applications. Although probability forecast tools should usually be developed with logistic regression, this technique could be easily generalized to any linear regression forecast tool to estimate the probability of exceeding any desired threshold . This could be useful for previously developed linear regression forecast tools or new forecast applications where statistical analysis software to perform logistic regression is not available. The tool was delivered in two formats - a Microsoft Excel GUI and a Tool Command Language/Tool Kit (Tcl/Tk) GUI in the Meteorological Interactive Data Display System (MIDDS). The Microsoft Excel GUI reads a MesoNAM text file containing hourly forecasts from 0 to 84 hours, from one model run (00 or 12 UTC). The GUI then displays e peak wind speed, average wind speed, and the probability the peak wind will meet or exceed the 25-, 35- and 50-kt thresholds. The user can display the Day-1 through Day-3 peak wind forecasts, and separate forecasts are made for precipitation and non-precipitation days. The MIDDS GUI uses data from the NAM and Global Forecast System (GFS), instead of the MesoNAM. It can display Day-1 and Day-2 forecasts using NAM data, and Day-1 through Day-5 forecasts using GFS data. The timing of the peak wind is not displayed, since the independent verification showed that none of the forecast methods performed significantly better than climatology. The forecaster should use the climatological timing of the peak wind (2248 UTC) as a first guess and then adjust it based on the movement of weather features.

Barrett, Joe H., III↗

Experimental Investigation on Cooling performance of A Thermoelectric Freezer

Thermoelectric heat pumps (TEHPs) have found widespread use in the electronics cooling industry and portable refrigerators. However, there has been a lack of extensive research on the application of TEHPs in low-temperature refrigeration settings. To address this gap, various configurations of TEHPs were fabricated to assess their suitability for freezer applications. Key parameters such as cooling capacity and system performance of the TEHPs were crucial in evaluating these configurations. Three configurations, each with different numbers of cooling units and fan arrangements, were tested using a 300-liter freezer prototype under typical room conditions (21°C). A cooling unit is comprised of two-stage thermoelectric modules, an aluminum plate fin heat exchanger sink with fans positioned either on top or directing airflow through the center, and a cooling block with circulating icy water for heat dissipation. Across all configurations, the minimum temperature inside the freezer cabinet reached -16.0°C. The cooling capacity peaked at 74.7 W, with the thermoelectric coefficient of performance (COP) reaching a maximum of 0.45. System COP ranged from 0.23 to 0.28. Minimum TE power consumption was recorded at 138.8 W, with TE system power consumption at 174.4 W, indicating feasibility for practical residential freezer applications. This investigation lays the foundation for integrating TE freezers with ice thermal storage systems.

Hu, Yifeng↗

A Multi-Center Controlled Study of the Acute and Chronic Effects of Cooling Therapy for MS

To determine the acute and chronic effects of cooling therapy on patients with MS using objective functional performance measures and self-assessed measures of fatigue. Cooling demyelinated nerves can reduce conduction block, potentially improving symptoms of MS. Significant acute and chronic effects of cooling have not been demonstrated in a multi-center, controlled, blinded study using objective measures of neurologic function. Patients (N=84) with definite MS, mild to moderate disability (EDSS less than 6.0), and self-reported heat sensitivity were enrolled at 5 study sites. Acute effects of cooling were assessed by randomly assigning subjects to high-dose or low-dose cooling for one hour using an active cooling vest and cap (Life Enhancement Technologies, Santa Clara, CA). Settings were individualized to maintain the cooling garments at 55 F for the high-dose treatment and 70 F for the low-dose treatment. Both patients and examining investigators were blinded to treatment assignments. The MSFC and visual acuity/contrast sensitivity were assessed before and 30 minutes after treatment. The following week, subjects had an identical visit with the alternate cooling treatment. Chronic effects of cooling were assessed by randomly assigning the same subjects to unblinded daily home cooling or observation for 4 weeks. All subjects completed the Rochester Fatigue Diary (RFD) twice weekly and subjective measures of strength, cognition, and energy level daily. At the end of the period, subjects completed the Modified Fatigue Impact Scale (MFIS) and underwent another high-dose cooling session with assessment of the MSFC and vision. After a one-week washout period, subjects crossed over to the alternate 4-week treatment. Oral temperatures were reduced with both acute treatments (0.8 +/- .06 F, high and 0.5 +/- .06 F, low). While mean MSFC did not change significantly during individual cooling sessions, post hoc analysis pooling the 3 high-dose cooling sessions revealed an improvement in MSFC scores (acute phase 0.064 +/- 0.020, p = 0.0013; chronic phase 0.044 +/- 0.021, p = 0.0368) from before to after cooling. The change in MSFC scores during the acute cooling sessions was not related to the extent of change in oral temperatures. Both the RFD score and the MFIS indicate a significantly lower fatigue level during the cooling month compared to observation (RFD, 2.53 +/- 0.83,p = 0.0033; MFIS 7.63 +/- 1.56, p = 0.0001).

Luna, Bernadette↗

Geospatial Characterization of Low-Temperature Heating and Cooling Demand in the United States: Preprint

Geothermal resources at temperatures below 150 degrees C have great potential as energy sources for various direct-use applications including heating and cooling in residential and commercial buildings. This study geospatially quantifies U.S. heating and cooling demand in residential, commercial, and manufacturing sectors; heating demand in the agricultural sector; and cooling demand in data centers at the county level through end-use energy consumption, expenditure, and commissioned power analyses. Heating and cooling demand in the residential sector was estimated using energy consumption data obtained from the U.S. Energy Information Administration accounting for different U.S. climate zones. For commercial sector analysis, the end-use major fuel energy intensity at the census division level was disaggregated to the county level with respect to principal building activities. Heating and cooling demand analysis for the manufacturing sector was based on end-use energy consumption for direct-use total process categorized by the North America Industry Classification System. Fuel expenditures in the U.S. Department of Agriculture Farm Production Expenditures were examined for heating demand analysis in the agricultural sector, particularly for the greenhouse, nursery, and floriculture production category. Lastly, commissioned power for data centers in the United States were explored for cooling demand analysis. Results indicated a significant fraction of U.S. primary energy consumption is used for low-temperature heating and cooling applications. Heating and cooling demand in residential and commercial sectors is significantly affected by the number of housing units and climate zone designations, while heating and cooling demand in manufacturing and agricultural sectors and data centers are mainly dependent on the number of facilities and their locations. Maps were generated visualizing where heating and cooling demand is high and, overlain with geothermal resource maps, can indicate locations where geothermal energy can supply this heating and cooling demand.

cooling demand↗

Geospatial Characterization of Low-Temperature Heating and Cooling Demand in the United States

Geothermal resources at temperatures below 150 degrees C have great potential as energy sources for various direct-use applications including heating and cooling in residential and commercial buildings. This study geospatially quantifies U.S. heating and cooling demand in residential, commercial, and manufacturing sectors; heating demand in the agricultural sector; and cooling demand in data centers at the county level through end-use energy consumption, expenditure, and commissioned power analyses. Heating and cooling demand in the residential sector was estimated using energy consumption data obtained from the U.S. Energy Information Administration accounting for different U.S. climate zones. For commercial sector analysis, the end-use major fuel energy intensity at the census division level was disaggregated to the county level with respect to principal building activities. Heating and cooling demand analysis for the manufacturing sector was based on end-use energy consumption for direct-use total process categorized by the North America Industry Classification System. Fuel expenditures in the U.S. Department of Agriculture Farm Production Expenditures were examined for heating demand analysis in the agricultural sector, particularly for the greenhouse, nursery, and floriculture production category. Lastly, commissioned power for data centers in the United States were explored for cooling demand analysis. Results indicated a significant fraction of U.S. primary energy consumption is used for low-temperature heating and cooling applications. Heating and cooling demand in residential and commercial sectors is significantly affected by the number of housing units and climate zone designations, while heating and cooling demand in manufacturing and agricultural sectors and data centers are mainly dependent on the number of facilities and their locations. Maps were generated visualizing where heating and cooling demand is high and, overlain with geothermal resource maps, can indicate locations where geothermal energy can supply this heating and cooling demand.

cooling demand↗