Search NASA⌕ Search

SEARCH · Search NASA

Results for “correlation coefficient”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Can radiomics features be reproducibly measured from CBCT images for patients with non-small cell lung cancer?

Purpose: Increasing evidence suggests radiomics features extracted from computed tomography (CT) images may be useful in prognostic models for patients with nonsmall cell lung cancer (NSCLC). This study was designed to determine whether such features can be reproducibly obtained from cone-beam CT (CBCT) images taken using medical Linac onboard-imaging systems in order to track them through treatment. Methods: Test-retest CBCT images of ten patients previously enrolled in a clinical trial were retrospectively obtained and used to determine the concordance correlation coefficient (CCC) for 68 different texture features. The volume dependence of each feature was also measured using the Spearman rank correlation coefficient. Features with a high reproducibility (CCC > 0.9) that were not due to volume dependence in the patient test-retest set were further examined for their sensitivity to differences in imaging protocol, level of scatter, and amount of motion by using two phantoms. The first phantom was a texture phantom composed of rectangular cartridges to represent different textures. Features were measured from two cartridges, shredded rubber and dense cork, in this study. The texture phantom was scanned with 19 different CBCT imagers to establish the features’ interscanner variability. The effect of scatter on these features was studied by surrounding the same texture phantom with scattering material (rice and solid water). The effect of respiratory motion on these features was studied using a dynamic-motion thoracic phantom and a specially designed tumor texture insert of the shredded rubber material. The differences between scans acquired with different Linacs and protocols, varying amounts of scatter, and with different levels of motion were compared to the mean intrapatient difference from the test-retest image set. Results: Of the original 68 features, 37 had a CCC >0.9 that was not due to volume dependence. When the Linac manufacturer and imaging protocol were kept consistent, 4–13 of these 37 features passed our criteria for reproducibility more than 50% of the time, depending on the manufacturer-protocol combination. Almost all of the features changed substantially when scatter material was added around the phantom. For the dense cork, 23 features passed in the thoracic scans and 11 features passed in the head scans when the differences between one and two layers of scatter were compared. Using the same test for the shredded rubber, five features passed the thoracic scans and eight features passed the head scans. Motion substantially impacted the reproducibility of the features. With 4 mm of motion, 12 features from the entire volume and 14 features from the center slice measurements were reproducible. With 6–8 mm of motion, three features (Laplacian of Gaussian filtered kurtosis, gray-level nonuniformity, and entropy), from the entire volume and seven features (coarseness, high gray-level run emphasis, gray-level nonuniformity, sum-average, information measure correlation, scaled mean, and entropy) from the center-slice measurements were considered reproducible. Conclusions: Some radiomics features are robust to the noise and poor image quality of CBCT images when the imaging protocol is consistent, relative changes in the features are used, and patients are limited to those with less than 1 cm of motion.

60 APPLIED LIFE SCIENCES↗

NON-THERMAL RESPONSE OF THE CORONA TO THE MAGNETIC FLUX DISPERSAL IN THE PHOTOSPHERE OF A DECAYING ACTIVE REGION

We analyzed Solar Dynamics Observatory line-of-sight magnetograms for a decaying NOAA active region (AR) 11451 along with co-temporal Extreme-Ultraviolet Imaging Spectrometer (EIS) data from the Hinode spacecraft. The photosphere was studied via time variations of the turbulent magnetic diffusivity coefficient, {eta}(t), and the magnetic power spectrum index, {alpha}, through analysis of magnetogram data from the Helioseismic and Magnetic Imager (HMI). These measure the intensity of the random motions of magnetic elements and the state of turbulence of the magnetic field, respectively. The time changes of the non-thermal energy release in the corona was explored via histogram analysis of the non-thermal velocity, v {sub nt}, in order to highlight the largest values at each time, which may indicate an increase in energy release in the corona. We used the 10% upper range of the histogram of v {sub nt} (which we called V {sup upp} {sub nt}) of the coronal spectral line of Fe XII 195 A. A 2 day time interval was analyzed from HMI data, along with the EIS data for the same field of view. Our main findings are the following. (1) The magnetic turbulent diffusion coefficient, {eta}(t), precedes the upper range of the v {sub nt} with the time lag of approximately 2 hr and the cross-correlation coefficient of 0.76. (2) The power-law index, {alpha}, of the magnetic power spectrum precedes V {sup upp} {sub nt} with a time lag of approximately 3 hr and the cross-correlation coefficient of 0.5. The data show that the magnetic flux dispersal in the photosphere is relevant to non-thermal energy release dynamics in the above corona. The results are consistent with the nanoflare mechanism of the coronal heating, due to the time lags being consistent with the process of heating and cooling the loops heated by nanoflares.

79 ASTRONOMY AND ASTROPHYSICS↗

Quickest Detection for Changes in Maximal kNN Coherence of Random Matrices

This paper addresses the problem of quickest detection of a change in the maximal coherence between columns of a n p random matrix based on a sequence of matrix observations having a single unknown change point. The random matrix is assumed to have identically distributed rows and the maximal coherence is defined as the largest of the ( 2 p) correlation coefficients associated with any row. Likewise the κ nearest neighbor (kNN) coherence is defined as the κ-th largest of these correlation coefficients. The forms of the preand postchange distributions of the observed matrices are assumed to belong to the family of elliptically contoured densities with sparse dispersion matrices but are otherwise unknown. A nonparametric stopping rule is proposed that is based on the maximal kNN sample coherence between columns of each observed random matrix. This is a summary statistic that is related to a test of existence of a hub vertex in a sample correlation graph having degree at least κ. Performance bounds on the delay and false alarm performance of the proposed stopping rule are obtained in the purely high-dimensional regime where p → ∞ and n is fixed. When the prechange dispersion matrix is diagonal it is shown that, among all functions of the proposed summary statistic, the proposed stopping rule is asymptotically optimal under a minimax quickest change detection model as the stopping threshold approaches infinity. Furthermore, the theory developed also applies to sequential hypothesis testing and fixed sample size tests.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Google search patterns monitoring the daily health impact of heatwaves in England: How do the findings compare to established syndromic surveillance systems from 2013 to 2017?

Highlights: • Heat health-related Google search term frequency increased during heatwave events. • Google data correlated well with validated syndromic heat health indicators. • A similar timeliness was seen between daily Google and syndromic data in England. • Google search data could be of benefit in monitoring heat-related morbidity. One of the implications of climate change is a predicted increase in frequent and severe heatwaves. The impact of heatwaves on the health of the population is captured through real-time syndromic healthcare surveillance systems monitored daily in England during the summer months. Internet search data could potentially provide improved timeliness and help to assess the wider population health impact of heat by capturing a population sub-group who are symptomatic but do not seek healthcare. A retrospective observational study was carried out from June 2013 to September 2017 in England to compare daily trends in validated syndromic surveillance heat-related morbidity indicators against symptom-based heatwave related Google search terms. The degree of correlation was determined with Spearman correlation coefficients and lag assessment was carried out to determine timeliness. Daily increases in frequency in Google search terms during heatwave events correlated well with validated syndromic indicators. Correlation coefficients between search term frequency and syndromic indicators from 2013 to 2017 were highest with the telehealth service NHS 111 (range of 0.684–0.900 by search term). Lag analysis revealed a similar timeliness between the data sources, suggesting Google data did not provide a delayed or earlier signal in the context of England's syndromic surveillance systems. This work highlights the potential benefits for countries which lack established public health surveillance systems to monitor heat-related morbidity and the use of internet search data to assess the wider population health impact of exposure to heat.

54 ENVIRONMENTAL SCIENCES↗

High‐frequency daily temperature variability in China and its relationship to large‐scale circulation

ABSTRACT Two measures of intra‐seasonal variability, indicated respectively by standard deviations ( SD ) and day‐to‐day ( DTD ) fluctuations denoted by absolute differences between adjacent 2‐day periods, as well as their relationships with large‐scale circulation patterns were investigated in China during 1962–2008 on the basis of homogenized daily temperature records from 549 local stations and reanalysis data. Our results show that both the SD and DTD of daily minimum temperatures ( T min ) in summer as well as the minimum and maximum temperatures in winter have been decreasing, while the daily maximum temperature ( T max ) variability in summer is fluctuating more, especially over southern China. In summer, an attribution analysis indicates that the intensity of the Western Pacific Subtropical High ( WPSH ) and high‐level East Asian Subtropical Jet stream ( EASJ ) are positively correlated with both SD and DTD , but the correlation coefficients are generally greater with the SD than with the DTD of the daily maximum temperature, T max . In contrast, the location of the EASJ shows the opposite correlation pattern, with intensity regarding the correlation with both SD and DTD . In winter, the Arctic Oscillation ( AO ) is negatively correlated with both the SD and DTD of the daily minimum temperature, but its intra‐seasonal variability exhibits good agreement with the SD of the T min . The Siberian High acts differently with respect to the SD and DTD of the T min , demonstrating a regionally consistent positive correlation with the SD . Overall, the large‐scale circulation can well explain the intra‐seasonal SD, but DTD fluctuations may be more local and impacted by local conditions, such as changes in the temperature itself, the land surface, and so on.

Wu, Fu‐Ting↗

SU-E-J-66: Evaluation of a Real-Time Positioning Assistance Simulator System for Skull Radiography Using the Microsoft Kinect

Purpose: The purpose of this study is to investigate the feasibility of a low cost, small size positioning assistance simulator system for skull radiography using the Microsoft Kinect sensor. A conventional radiographic simulator system can only measure the three-dimensional coordinates of an x-ray tube using angle sensors, but not measure the movement of the subject. Therefore, in this study, we developed a real-time simulator system using the Microsoft Kinect to measure both the x-ray tube and the subject, and evaluated its accuracy and feasibility by comparing the simulated and the measured x-ray images. Methods: This system can track a head phantom by using Face Tracking, which is one of the functions of the Kinect. The relative relationship between the Kinect and the head phantom was measured and the projection image was calculated by using the ray casting method, and by using three-dimensional CT head data with 220 slices at 512 × 512 pixels. X-ray images were thus obtained by using a computed radiography (CR) system. We could then compare the simulated projection images with the measured x-ray images from 0 degrees to 45 degrees at increments of 15 degrees by calculating the cross correlation coefficient C. Results: The calculation time of the simulated projection images was almost real-time (within 1 second) by using the Graphics Processing Unit(GPU). The cross-correlation coefficients C are: 0.916; 0.909; 0.891; and, 0.886 at 0, 15, 30, and 45 degrees, respectively. As a result, there were strong correlations between the simulated and measured images. Conclusion: This system can be used to perform head positioning more easily and accurately. It is expected that this system will be useful for learning radiographic techniques by students. Moreover, it could also be used for predicting the actual x-ray image prior to x-ray exposure in clinical environments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Constitutive Modeling of High-Temperature Flow Stress of Armor Steel in Ballistic Applications: A Comparative Study

Armox 500T is one of the armor grade steels extensively used as armor against bullet penetration in ballistic applications. In such applications, the material undergoes plastic deformation at large strain rates (10{sup 3} s{sup −1}) at temperatures of the order of 673-1373 K. In the present work, an attempt has been made to predict strain rate and temperature-dependent flow behavior of Armox 500T steel through physical-based model like modified Zerilli–Armstrong (M-ZA) and phenomenological-based models like Cowper Symonds (CS), modified Johnson–Cook (M-JC), Arrhenius (Arr.) and Khan–Huang–Liang (KHL) constitutive material model. Isothermal uniaxial compression tests at low strain rates (10{sup −3}-10{sup −1} s{sup −1}) and dynamic compression tests at high strain rates (600-3000 s{sup −1}) in the temperatures range of 673-1373 K have been carried out to determine constitutive material model parameters. In addition, an artificial neural network (ANN) model that works on multilayer perceptron (MLP) based back propagation neural network (BPNN) has also been developed. The results from all these models have been compared in terms of three statistical parameters namely correlation coefficient (R), mean absolute percent error (MAPE) and its standard deviation (Δ). The results revealed that M-JC model shows highest correlation coefficient and lowest average absolute error. Further, ANN model prediction has the highest accuracy with R = 0.999 and MAPE = 1.052.

36 MATERIALS SCIENCE↗

Velocity reconstruction in the era of DESI and Rubin/LSST. II. Realistic samples on the light cone

Reconstructing the galaxy peculiar velocity field from the distribution of large-scale structure plays an important role in cosmology. On one hand, it gives us an insight into structure formation and gravity; on the other, it allows us to selectively extract the kinetic Sunyaev-Zel’dovich (kSZ) effect from cosmic microwave background maps. In this work, we employ high-accuracy synthetic galaxy catalogs on the light cone to investigate how well we can recover the velocity field when utilizing the three-dimensional spatial distribution of the galaxies in a modern large-scale structure experiment such as the Dark Energy Spectroscopic Instrument (DESI) and the Rubin Observatory Legacy Survey of Space and Time. In particular, we adopt the standard technique used in baryon acoustic oscillation analysis for reconstructing the Zel’dovich displacements of galaxies through the continuity equation, which yields a first-order approximation to their large-scale velocities. We investigate variations in the number density, bias, mask, area, redshift noise, and survey depth, as well as modifications to the settings of the standard reconstruction algorithm. Since our main goal is to provide guidance for planned kSZ analysis between DESI and the Atacama Cosmology Telescope, we apply velocity reconstruction to a faithful representation of DESI spectroscopic and photometric targets. We report the cross-correlation coefficient between the reconstructed and the true velocities along the line of sight. For the DESI Y1 spectroscopic survey, we expect the correlation coefficient to be r ≈ 0.64, while for a photometric survey with δ z /(1+z) = 0.02, as is approximately the case for the Legacy Survey used in the target selection of DESI galaxies, r shrinks by half to r ≈ 0.31. Here, we hope the results in this paper can be used to inform future kSZ stacking studies and other velocity reconstruction analyses planned with the next generation of cosmology experiments.

79 ASTRONOMY AND ASTROPHYSICS↗

Is Diaphragm Motion a Good Surrogate for Liver Tumor Motion?

Purpose: To evaluate the relationship between liver tumor motion and diaphragm motion. Methods and Materials: Fourteen patients with hepatocellular carcinoma (10 of 14) or liver metastases (4 of 14) undergoing radiation therapy were included in this study. All patients underwent single-slice cine–magnetic resonance imaging simulations across the center of the tumor in 3 orthogonal planes. Tumor and diaphragm motion trajectories in the superior–inferior (SI), anterior–posterior (AP), and medial–lateral (ML) directions were obtained using an in-house-developed normalized cross-correlation–based tracking technique. Agreement between the tumor and diaphragm motion was assessed by calculating phase difference percentage, intraclass correlation coefficient, and Bland-Altman analysis (Diff). The distance between the tumor and tracked diaphragm area was analyzed to understand its impact on the correlation between the 2 motions. Results: Of all patients, the mean (±standard deviation) phase difference percentage values were 7.1% ± 1.1%, 4.5% ± 0.5%, and 17.5% ± 4.5% in the SI, AP, and ML directions, respectively. The mean intraclass correlation coefficient values were 0.98 ± 0.02, 0.97 ± 0.02, and 0.08 ± 0.06 in the SI, AP, and ML directions, respectively. The mean Diff values were 2.8 ± 1.4 mm, 2.4 ± 1.1 mm, and 2.2 ± 0.5 mm in the SI, AP, and ML directions, respectively. Tumor and diaphragm motions had high concordance when the distance between the tumor and tracked diaphragm area was small. Conclusions: This study showed that liver tumor motion had good correlation with diaphragm motion in the SI and AP directions, indicating diaphragm motion in the SI and AP directions could potentially be used as a reliable surrogate for liver tumor motion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Utility of Atmospheric Transport Runs Done Backwards in Time for Source Term Estimation

In a general sense, the equations describing transport of an atmospheric contaminant are reversible in time. However, the time reversibility is not perfect. For a source term estimation problem, one atmospheric transport model (ATM) run done backwards in time to represent the influence of a single sample value can yield as much information as hundreds or thousands of forwards ATM runs. Thus, backwards ATM are often used to limit the computational burden of an analysis. A large number of paired ATM runs at 14 release locations were used to explore the agreement between dilution factors for the forward and backwards time directions. Four of the release locations have correlation coefficients between forward and backwards dilution factors greater than 0.9. None of the four have large elevation changes within 100 km of the release location. The two release locations with the lowest correlation coefficients are in mountainous terrain with large elevation differences. Elevation changes have a greater negative influence on the correlations than distance to the sampler or plume transit times. The locations of the releases were estimated using dilution factors from backwards ATM runs. Many of the location estimates are close to the release point, vindicating the general approach of using ATM runs backwards in time. Aggregated over the 14 release points, 26% of the location estimates were within 10 km of the release point, 61% were within 25 km, 80% were within 50 km, and 87% were within 75 km. Most of the remaining 13% (poor matches) occur for two release locations in mountainous terrain. Good time-reversibility cannot be guaranteed for a new analysis, so we recommend that any source term solution using backwards ATM runs should include comparisons based on forward ATM runs. As an example, calculations show good agreement between dilutions in different time-directions for samples taken after the announced nuclear test by the Democratic People’s Republic of Korea in 2013.

Eslinger, Paul W.↗

Validation of seismic velocity models in southern California with full-waveform simulations

SUMMARY Crustal seismic velocity models provide essential information for many applications including earthquake source properties, simulations of ground motion and related derivative products. We present a systematic workflow for assessing the accuracy of velocity models with full-waveform simulations. The framework is applied to four regional seismic velocity models for southern California: CVM-H15.11, CVM-S4.26, CVM-S4.26.M01 that includes a shallow geotechnical layer, and the model of Berg et al. For each model, we perform 3-D viscoelastic wave propagation simulations for 48 virtual seismic noise sources (down to 2 s) and 44 moderate-magnitude earthquakes (down to 2 s generally and 0.5 s for some cases) assuming a minimum shear wave velocity of 200 m s–1. The synthetic waveforms are compared with observations associated with both earthquake records and noise cross-correlation data sets. We measure, at multiple period bands for well-isolated seismic phases, traveltime delays and normalized zero-lag cross-correlation coefficients between the synthetic and observed data. The obtained measurements are summarized using the mean absolute derivation of time delay and the mean correlation coefficient. These two metrics provide reliable statistical representations of model quality with consistent results in all data sets. In addition to assessing the overall (average) performance of different models in the entire study area, we examine spatial variations of the models’ quality. All examined models show good phase and waveform agreements for surface waves at periods longer than 5 s, and discrepancies at shorter periods reflecting small-scale heterogeneities and near-surface structures. The model performing best overall is CVM-S4.26.M01. The largest misfits for both body and surface waves are in basin structures and around large fault zones. Inaccuracies generated in these areas may affect tomography and model simulation results at other regions. The seismic velocity models for southern California can be improved by adding better resolved structural representations of the shallow crust and volumes around the main faults.

58 GEOSCIENCES↗

Evaluation of WSR-88D Level III and MRMS Rainfall Estimates Against Rain Gauge Observations at the Savannah River Site

Rainfall data for the Savannah River Site (SRS) has been historically measured by rain gauges. These instruments serve as ground truth for most climatological and weather applications; however, gauge measurements are prone to errors or biases under certain weather conditions. Rainfall estimates from radar reflectivity values have been developed and improved over the years and serve as an alternative or supplement for gauge measurements. This study compares measurements from tipping bucket rain gauges with rainfall estimates from the NOAA NWS WSR-88D Level III hourly rainfall product and the Multi-Radar Multi-Sensor (MRMS) gauge-corrected precipitation estimate. Results show good agreement between radar derived amounts and ground measurements, with MRMS values showing correlation coefficients of 0.60-0.95 and RMSE values of less than 1.0 cm (0.4 in). The WSR-88D Level III estimates result in correlation coefficients of 0.46-0.86 and RMSE values of less than 1.3 cm (0.5 in). Few outliers are observed for each data pair and are evaluated against precipitation classification products (WSR-88D Hybrid Hydrometeor Classification product and MRMS Precipitation Flag product). The rain gauges used in this study are not part of the Hydrometeorological Automated Data System (HADS) network used to correct the MRMS estimates and therefore, results of this work provide an independent validation of the MRMS gauge correction scheme.

54 ENVIRONMENTAL SCIENCES↗

Generation of Low Fidelity Experimental Covariance Matrices for ICSBEP Cases

In validation, statistical methods routinely incorporate information from integral experiments to improve estimations of code biases and uncertainties. One source of high quality integral experiments is the ICSBEP Handbook. While uncertainties for criticality benchmarks are well characterized in the Handbook, information pertaining to the shared uncertainty/covariance between the cases is sparse, yet required for the aforementioned methods; correlations can result from using the same fuel for example. To remedy the lack of available covariance data in the Handbook, recent efforts have been undertaken, notably, within the framework of the NEA Expert Group on Uncertainty Analysis in Criticality Safety Assessment (UACSA) under the Working Party on Nuclear Criticality Safety (WPNCS) . The UACSA activities have focused primarily on comparing methods used to generate high quality covariance matrices for a small number of evaluations. Despite these efforts, within the Database for ICSBEP DICE only about 2% of the nearly 5000 experiments in the ICSBEP Handbook have correlation coefficients, so the amount of work required to generate the missing data appears daunting. And so, to fill in the gaps where no correlations are available, it is proposed to generate low fidelity correlations by isolating the largest components of uncertainty and determining the fraction shared between cases within an evaluation. Uncertainties can be shared when they are not independently measured, or the source of uncertainty is unchanged between cases. The degree to which an uncertainty is shared is linked to the experimental procedure; an approximation is made that in the absence of additional information, similar experimental procedures will lead to a similar fraction of shared uncertainty. Between experimental procedures there is some commonality. One method, proposed here, to help elucidate similar procedures is to encode each procedure into a decision tree grouped by uncertainty type. End nodes of the tree require judgment to assign the fraction of shared uncertainty between cases associated with the node. This can also be thought of as a set of rules, such that if experimental procedures and conditions occurred, then assign the shared uncertainty as some number between 0.0 and 1.0. One advantage of such a procedure is the formation of a transparent logical link between the judgment applied and the amount of shared uncertainty. This makes the results both more reproducible and easy to update. Generating correlation coefficients is reduced to developing decision trees that categorize how the experiments were done, and apply judgment of the degree of shared uncertainty for the end node of the tree. Trees need to be constructed after reading section 1 and 2 of the evaluation and some evaluations certainly do not contain enough information to create informative decision trees nor to assign an amount of shared uncertainty. These evaluations will not be considered here. (authors)

42 ENGINEERING↗

Performance evaluation of stand alone hybrid PV-wind generator

This paper presents the performance evaluation of standalone hybrid system on Photovoltaic (PV)-Wind generator at Faculty of Electrical Engineering (FKE), UTeM. The hybrid PV-Wind in UTeM system is combining wind turbine system with the solar system and the energy capacity of this hybrid system can generate up to charge the battery and supply the LED street lighting load. The purpose of this project is to evaluate the performance of PV-Wind hybrid generator. Solar radiation meter has been used to measure the solar radiation and anemometer has been used to measure the wind speed. The effectiveness of the PV-Wind system is based on the various data that has been collected and compared between them. The result shows that hybrid system has greater reliability. Based on the solar result, the correlation coefficient shows strong relationship between the two variables of radiation and current. The reading output current followed by fluctuate of solar radiation. However, the correlation coefficient is shows moderate relationship between the two variables of wind speed and voltage. Hence, the wind turbine system in FKE show does not operate consistently to produce energy source for this hybrid system compare to PV system. When the wind system does not fully operate due to inconsistent energy source, the other system which is PV will operate and supply the load for equilibrate the extra load demand.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Python Waveform Cross-Correlation

PyWCC is a tool to compute seismic waveform cross-correlation coefficients on single-component or multiple-component seismic data across a network of seismic sensors. PyWCC compares waveform data templates with continuous seismic data, associates the resulting detections, identifies the template with the highest cross-correlation coefficient, and outputs a catalog of detections above a user-defined absolute cross-correlation threshold value.

Templeton, Dennise↗

A METHOD TO EXTRACT THE ANGULAR POWER SPECTRUM OF THE EPOCH OF REIONIZATION FROM LOW-FREQUENCY RADIO INTERFEROMETERS

The redshifted 21 cm signal of neutral hydrogen from the epoch of reionization (EoR) is extremely weak and its first detection is therefore expected to be statistical with first-generation low-frequency radio interferometers. In this Letter, we propose a method to extract the angular power spectrum of the EoR from the visibility correlation coefficients p{sub ij} (u, v), instead of the visibilities V{sub ij} (u, v) measured directly by radio interferometers in conventional algorithm. The visibility correlation coefficients are defined as p{sub ij}(u,v)=V{sub ij}(u,v)/{radical}(|V{sub ii}||V{sub jj}|) by introducing the autocorrelation terms V{sub ii} and V{sub jj} such that the angular power spectrum C{sub l} can be obtained through C{sub l} = T {sup 2}{sub 0}(|p{sub ij} (u, v)|{sup 2}), independently of the primary beams of antennas. This also partially removes the influence of receiver gains in the measurement of C{sub l} because the amplitudes of the gains cancel each other out in the statistical average operation of (|p{sub ij} (u, v)|{sup 2}). We use the average system temperature T{sub 0} as a calibrator of C{sub l}, which is dominated by the Milky Way and extragalactic sources in the frequency range that we are interested in, below 200 MHz. Finally, we demonstrate the feasibility of this novel method using the simulated sky maps as targets and the 21 CentiMeter Array (21CMA) as interferometer.

79 ASTRONOMY AND ASTROPHYSICS↗

BROADBAND STUDY WITH SUZAKU OF THE MAGNETAR CLASS

Broadband (0.8-70 keV) spectra of the persistent X-ray emission from nine magnetars were obtained with Suzaku, including three objects in apparent outburst. The soft X-ray component was detected from all of them, with a typical blackbody temperature of kT {approx} 0.5 keV, while the hard-tail component, dominating above {approx}10 keV, was detected at {approx}1 mCrab intensity from seven of them. Therefore, the spectrum composed of a soft emission and a hard-tail component may be considered to be a common property of magnetars, both in their active and quiescent states. Wide-band spectral analyses revealed that the hard-tail component has a 1-60 keV flux, F {sub h}, comparable to or even higher than that carried by the 1-60 keV soft component, F {sub s}. The hardness ratio (HR) of these objects, defined as {xi} {identical_to} F {sub h}/F {sub s}, was found to be tightly anti-correlated with their characteristic age {tau}{sub c} as {xi} = (3.3 {+-} 0.3) x ({tau}{sub c}/1 kyr){sup -0.67{+-}0.04} with a correlation coefficient of -0.989, over the range from {xi} {approx} 10 to {xi} {approx} 0.1. Magnetars in outburst states were found to lie on the same correlation as relatively quiescent ones. This HR is also positively correlated with their surface magnetic fields with a correlation coefficient of 0.873. In addition, the hard-tail component becomes harder toward sources with older characteristic ages, with the photon index changing from {approx}1.7 to {approx}0.4.

79 ASTRONOMY AND ASTROPHYSICS↗

Breast density quantification using magnetic resonance imaging (MRI) with bias field correction: A postmortem study

Purpose: Quantification of breast density based on three-dimensional breast MRI may provide useful information for the early detection of breast cancer. However, the field inhomogeneity can severely challenge the computerized image segmentation process. In this work, the effect of the bias field in breast density quantification has been investigated with a postmortem study. Methods: T1-weighted images of 20 pairs of postmortem breasts were acquired on a 1.5 T breast MRI scanner. Two computer-assisted algorithms were used to quantify the volumetric breast density. First, standard fuzzy c-means (FCM) clustering was used on raw images with the bias field present. Then, the coherent local intensity clustering (CLIC) method estimated and corrected the bias field during the iterative tissue segmentation process. Finally, FCM clustering was performed on the bias-field-corrected images produced by CLIC method. The left–right correlation for breasts in the same pair was studied for both segmentation algorithms to evaluate the precision of the tissue classification. Finally, the breast densities measured with the three methods were compared to the gold standard tissue compositions obtained from chemical analysis. The linear correlation coefficient, Pearson'sr, was used to evaluate the two image segmentation algorithms and the effect of bias field. Results: The CLIC method successfully corrected the intensity inhomogeneity induced by the bias field. In left–right comparisons, the CLIC method significantly improved the slope and the correlation coefficient of the linear fitting for the glandular volume estimation. The left–right breast density correlation was also increased from 0.93 to 0.98. When compared with the percent fibroglandular volume (%FGV) from chemical analysis, results after bias field correction from both the CLIC the FCM algorithms showed improved linear correlation. As a result, the Pearson'sr increased from 0.86 to 0.92 with the bias field correction. Conclusions: The investigated CLIC method significantly increased the precision and accuracy of breast density quantification using breast MRI images by effectively correcting the bias field. It is expected that a fully automated computerized algorithm for breast density quantification may have great potential in clinical MRI applications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗