Search NASA⌕ Search

SEARCH · Search NASA

Results for “correlation filter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Data reduction analysis and application technique development for atmospheric trace gas constituents derived from remote sensors on satellite or airborne platforms

The applicability of the gas filter correlation radiometer (GFCR) to the measurement of tropospheric carbon monoxide gas was investigated. An assessment of the GFRC measurement system to a regional measurement program was conducted through extensive aircraft flight-testing of several versions of the GFRC. Investigative work in the following areas is described: flight test planning and coordination, acquisition of verifying CO measurements, determination and acquisition of supporting meteorological data requirements, and development of supporting computational software.

Casas, J. C.↗

A system for measuring methane fluxes from inland and coastal wetland environments

A CH4 measuring system with a sensitivity of 0.01 ppmv and a response time of 1 sec is described. Pulses are separable from moving and stationary readings, the device floats, and air velocity in the chamber can be controlled in the range 0-4.4 m/sec. The system is set on the water so that controlled speed air from beneath can enter an inner chamber and be pumped through a gas filter correlation system (GFC) before being returned to the chamber. The GFC mechanism yields an absorption signal in the form of a dc voltage, which a processor orders printed on a strip chart as a function of time. Detection of the CH4 amounts is through IR absorption, and the sensitivity of the instrument has been measured at .002-.051 g/sq m per day with air flows in the range 0.90-4.40 m/sec. The unit can be modified to detect CO and CO2, and further applications for low plant canopies and land surfaces are indicated.

Sebacher, D. I.↗

Methane flux in the Great Dismal Swamp

The paper reports measurements made over a 17-month period of the methane flux in the Great Dismal Swamp of Virginia in light of the potential implications of variations in atmospheric methane concentrations. Gas flux measurements were made by a technique combining a gas filter correlation IR absorption analyzer with improved sampling chambers that enclose a soil area under conditions ranging from totally flooded soils to dry soils resulting from drought conditions. Methane emissions are found to range from 0.0013 g CH4/sq m per day to 0.019 g CH4/sq m per day, depending on temperature and season, when the soil is in a waterlogged state. During drought conditions, the peat soils in the swamp were a sink for atmospheric methane, with fluxes from less than 0.001 to 0.005 g CH4/sq m per day and decreasing with decreasing temperature. Results illustrate the potential complexity of the processes which regulate the net flux of methane between wetland soils and the atmosphere.

Harriss, R. C.↗

Carbon monoxide mixing ratio inference from gas filter radiometer data

A new algorithm has been developed which permits, for the first time, real time data reduction of nadir measurements taken with a gas filter correlation radiometer to determine tropospheric carbon monoxide concentrations. The algorithm significantly reduces the complexity of the equations to be solved while providing accuracy comparable to line-by-line calculations. The method is based on a regression analysis technique using a truncated power series representation of the primary instrument output signals to infer directly a weighted average of trace gas concentration. The results produced by a microcomputer-based implementation of this technique are compared with those produced by the more rigorous line-by-line methods. This algorithm has been used in the reduction of Measurement of Air Pollution from Satellites, Shuttle, and aircraft data.

Wallio, H. A.↗

Airborne measurements of launch vehicle effluent of STS-2 launch on November 12, 1981 at Cape Canaveral, Florida

The second Space Shuttle (STS-2) was launched from the John F. Kennedy Space Center at 1010 EST on November 12, 1981. An instrumented light airplane was used to measure the emitted concentration of Shuttle exhaust products produced during launch. The airplane accomplished 31 passes through and under the exhaust cloud in the 1 hr 45 min immediately following the launch. Measurements included the following: (1) particulate data in the form of a light scattering coefficient obtained from an integrating nephelometer, (2) particulate concentrations and mass concentrations obtained from a spectrometer probe, (3) gaseous HCl and total HCl concentrations obtained from a gas-filter-correlation instrument and a chemiluminescent instrument, respectively, and (4) outside-air temperature and dew-point temperature. These data are presented along with time, altitude, and position for each cloud pass. These data are within the range of values observed during similar measurements made during the first Space Shuttle launch on April 12, 1981.

Maddrea, G. L., Jr.↗

Integrated-Circuit Active Digital Filter

Pipeline architecture with parallel multipliers and adders speeds calculation of weighted sums. Picture-element values and partial sums flow through delay-adder modules. After each cycle or time unit of calculation, each value in filter moves one position right. Digital integrated-circuit chips with pipeline architecture rapidly move 35 X 35 two-dimensional convolutions. Need for such circuits in image enhancement, data filtering, correlation, pattern extraction, and synthetic-aperture-radar image processing: all require repeated calculations of weighted sums of values from images or two-dimensional arrays of data.

Nathan, R.↗

Space Opportunities for Tropospheric Chemistry Research

The objective of this workshop was to assess future technological and scientific directions for measurements of tropospheric trace gases and aerosols from space. Various instrument technologies were considered including spectrometry, gas correlation filter radiometry, spectral radiometry, and lidar.

Levine, Joel S.↗

Development of data processing, interpretation and analysis system for the remote sensing of trace atmospheric gas species

The major emphasis is on the advancement of remote sensing technology. In particular, the gas filter correlation radiometer (GFCR) technique was applied to the measurement of trace gas species, such as carbon monoxide (CO), from airborne and Earth orbiting platforms. Through a series of low altitude aircraft flights, high altitude aircraft flights, and orbiting space platform flights, data were collected and analyzed, culminating in the first global map of carbon monoxide concentration in the middle troposphere and stratosphere. The four major areas of this remote sensing program, known as the Measurement of Air Pollution from Satellites (MAPS) experiment, are: (1) data acquisition, (2) data processing, analysis, and interpretation algorithms, (3) data display techniques, and (4) information processing.

Casas, Joseph C.↗

Feasibility of determining the vertical profile of carbon monoxide from a space platform

The results of a feasibility study conducted to determine the possibility of passively measuring the vertical profile of carbon monoxide in the troposphere on a global basis are presented. The instrument considered is a nadir-viewing gas correlation filter radiometer (GCFR). The basic instrument concept and radiative transfer equations are presented. The calculated signal functions, signal levels, sensitivity, and system noise levels of a spaceborne GCFR instrument are presented and discussed. It is concluded that a three- or four-level measurement of the atmospheric carbon monoxide mixing ratio in the troposphere is possible with this type of instrument.

Reichle, Henry, Jr.↗

New Remote Gas Sensor Using Rapid Electro-Optical Path Switching

Innovative gas filter correlation radiometer (GFCR) features nonmechanical switching of internal optical paths. Incoming radiation switched electro-optically, by means of polarization, between two optical paths, one of which contains correlation gas cell while other does not. Advantages include switching speed, 2 to 3 orders of magnitude faster than mechanical techniques, and high reliability. Applications include regional studies of atmospheric chemistry from either manned or unmanned aircraft as well as satellite studies of global distributions, sources and sink mechanisms for key species involved in chemistry of troposphere. Commercial applications: ability to survey many miles of natural gas pipelines rapidly from aircraft, pinpointing gas leaks by measuring methane at 2.3 micrometers.

Sachse, G. W.↗

Carbon monoxide measurements at Mace Head, Ireland

The North Atlantic Ocean is bordered by continents which may each, under the influence of seasonal weather patterns, act as sources of natural and anthropogenic trace gas and particulate species. Photochemically active species such as carbon monoxide (CO) react to form ozone (O3), a species of critical importance in global climate change. CO is sparingly soluble in water, and the relatively long lifetime of CO in the troposphere makes this species an ideal tracer of air masses with origin over land. We have measured CO using a nondispersive infrared gas filter correlation analyzer at Mace Head on the west coast of Ireland nearly continuously since August 9, 1991. Measurements of CO were acquired at 20-sec resolution and recorded as 60-sec averages. Daily, monthly, and diurnal variation data characteristics of CO mixing ratios observed at this site are reported. Depending on source regions of air parcels passing over this site, 60-min concentrations of CO range from clean air values of approximately 90 ppbv to values in excess of 300 ppbv. Data characterizing the correlation between 60-min CO and O3 mixing ratio data observed at this site are reported also.

Doddridge, Bruce G.↗

Optical remote sensing for measurement of toxic gases

There is renewed interest in using optical remote sensing techniques for measuring and monitoring airborne toxins. Many instruments have been used to measure traces of atmospheric molecular species. Some optical remote sensing technology is in use for measuring or monitoring toxic or pollutant gases. The examples in this article provide a number of lessons that may be of use in the new field of optical remote sensing of toxic gases. Topics covered include the following: atmospheric properties, Fourier transform spectrometry, gas-filter correlation, differential absorption laser systems, aircraft missions, laser long-path instruments, differential optical absorption spectrometry, and ozone measurement.

Grant, William B.↗

Remote sensing measurements of atmospheric methane at 2.3 microns with a nonmechanical GFCR

Gas filter correlation radiometer (GFCR) is a passive remote sensing technique used in a variety of atmospheric measurements. In recent years, a nonmechanical optical switching GFCR has been invented and developed at NASA Langley Research Center. The use of a polarization modulator, in conjunction with a polarization beamsplitter, enables rapid optical switching without mechanically moving parts. In comparison with the conventional GFCR, which involves mechanical chopping or switching between two optical paths, the nonmechanical GFCR possesses some very attractive advantages such as fast sampling rate, high reliability, low weight, and long operational life time. In a recent study, we have developed a new GFCR configuration and have fabricated a compact, nonmechanical breadboard instrument. Using this instrument, we have carried out atmospheric methane measurements in the 2.3 micron region. Measurement results are compared with theoretical predictions using the HITRAN database.

Wang, Liang-guo↗

Wavelet Applications for Flight Flutter Testing

Wavelets present a method for signal processing that may be useful for analyzing responses of dynamical systems. This paper describes several wavelet-based tools that have been developed to improve the efficiency of flight flutter testing. One of the tools uses correlation filtering to identify properties of several modes throughout a flight test for envelope expansion. Another tool uses features in time-frequency representations of responses to characterize nonlinearities in the system dynamics. A third tool uses modulus and phase information from a wavelet transform to estimate modal parameters that can be used to update a linear model and reduce conservatism in robust stability margins.

Lind, Rick↗

Wavelet Applications for Flight Flutter Testing

Wavelets present a method for signal processing that may be useful for analyzing responses of dynamical systems. This paper describes several wavelet-based tools that have been developed to improve the efficiency of flight flutter testing. One of the tools uses correlation filtering to identify properties of several modes throughout a flight test for envelope expansion. Another tool uses features in time-frequency representations of responses to characterize nonlinearities in the system dynamics. A third tool uses modulus and phase information from a wavelet transform to estimate modal parameters that can be used to update a linear model and reduce conservatism in robust stability margins.

Lind, Rick↗

Multi-Gas Sensor

A multi-gas sensor is provided which modulates a polarized light beam over a broadband of wavelengths between two alternating orthogonal polarization components. The two orthogonal polarization components of the polarization modulated beam are directed along two distinct optical paths. At least one optical path contains one or more spectral discrimination element, with each spectral discrimination element having spectral absorption features of one or more gases of interest being measured. The two optical paths then intersect, and one orthogonal component of the intersected components is transmitted and the other orthogonal component is reflected. The combined polarization modulated beam is partitioned into one or more smaller spectral regions of interest where one or more gases of interest has an absorption band. The difference in intensity between the two orthogonal polarization components is then determined in each partitioned spectral region of interest as an indication of the spectral emission/absorption of the light beam by the gases of interest in the measurement path. The spectral emission/absorption is indicative of the concentration of the one or more gases of interest in the measurement path. More specifically, one embodiment of the present invention is a gas filter correlation radiometer which comprises a polarizer, a polarization modulator, a polarization beam splitter, a beam combiner, wavelength partitioning element, and detection element. The gases of interest are measured simultaneously and, further, can be measured independently or non-independently. Furthermore, optical or electronic element are provided to balance optical intensities between the two optical paths.

Sachse, Glenn W.↗

Method for Balancing Detector Output to a Desired Level of Balance at a Frequency

A multi-gas sensor is provided which modulates a polarized light beam over a broadband of wavelengths between two alternating orthogonal polarization components. The two orthogonal polarization components of the polarization modulated beam are directed along two distinct optical paths. At least one optical path contains one or more spectral discrimination elements, with each spectral discrimination element having spectral absorption features of one or more gases of interest being measured. The two optical paths then intersect, and one orthogonal component of the intersected components is transmitted and the other orthogonal component is reflected. The combined polarization modulated beam is partitioned into one or more smaller spectral regions of interest where one or more gases of interest has an absorption band. The difference in intensity between the two orthogonal polarization components is then determined in each partitioned spectral region of interest as an indication of the spectral emission/absorption of the light beam by the gases of interest in the measurement path. The spectral emission/absorption is indicative of the concentration of the one or more gases of interest in the measurement path. More specifically, one embodiment of the present invention is a gas filter correlation radiometer which comprises a polarizer, a polarization modulator, a polarization beam splitter, a beam combiner, wavelength partitioning element, and detection element. The gases of interest are measured simultaneously and, further, can be measured independently or non-independently. Furthermore, optical or electronic element are provided to balance optical intensities between the two optical paths.

Sachse, Glenn W.↗

An Expert Assistant for Computer Aided Parallelization

The prototype implementation of an expert system was developed to assist the user in the computer aided parallelization process. The system interfaces to tools for automatic parallelization and performance analysis. By fusing static program structure information and dynamic performance analysis data the expert system can help the user to filter, correlate, and interpret the data gathered by the existing tools. Sections of the code that show poor performance and require further attention are rapidly identified and suggestions for improvements are presented to the user. In this paper we describe the components of the expert system and discuss its interface to the existing tools. We present a case study to demonstrate the successful use in full scale scientific applications.

Jost, Gabriele↗