Search NASA⌕ Search

SEARCH · Search NASA

Results for “cost best practices”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Southeast Regional CO 2 Utilization and Storage Acceleration Partnership (SECARB-USA): Needs Assessment Framework for Storage Complexes

A team of SECARB storage experts examined 63 formations at 39 sites that were selected to represent the range of diversity of newly assessed, as well as well-advanced, storage prospects in the SECARB region. We inventoried the data needs triggered by the requirements to obtain a Class VI UIC storage permit, the data needs that results from the requirement to create geocellular fluid flow models to support that permit, and by pragmatic and best practice inputs such as public acceptance, regulatory readiness, and pore space leasing. We anchored both the needs inventory and the processes for and cost of meeting the needs with data from 9 sites in in the SECARB area that have advanced far in characterization.

42 ENGINEERING↗

Procedure for Assessing the Suitability of Battery Second Life Applications after EV First Life

Using batteries after their first life in an Electric Vehicle (EV) represents an opportunity to reduce the environmental impact and increase the economic benefits before recycling the battery. Many different second life applications have been proposed, each with multiple criteria that have to be taken into consideration when deciding the most suitable course of action. In this article, a battery assessment procedure is proposed that consolidates and expands upon the approaches in the literature, and facilitates the decision-making process for a battery after it has reached the end of its first life. The procedure is composed of three stages, including an evaluation of the state of the battery, an evaluation of the technical viability and an economic evaluation. Options for battery configurations are explored (pack direct use, stack of battery packs, module direct use, pack refurbish with modules, pack refurbish with cells). By comparing these configurations with the technical requirements for second life applications, a reader can rapidly understand the tradeoffs and practical strategies for how best to implement second life batteries for their specific application. Lastly, an economic evaluation process is developed to determine the cost of implementing various second life battery configurations and the revenue for different end use applications. An example of the battery assessment procedure is included to demonstrate how it could be carried out.

25 ENERGY STORAGE↗

Performance Assessments of Demand Flexibility from Grid-Interactive Efficient Buildings: Issues and Considerations

This SEE Action Network report explains basic concepts and fundamental considerations for assessing the actual demand flexibility performance of buildings participating in demand flexibility programs and responding to time-varying retail rates. Demand flexibility is the capability of distributed energy resources (DERs) to adjust a building’s load profile across different timescales. Assessments determine the timing, location, quantity, and quality of grid services provided. The results can be used for financial settlements and to improve performance of demand flexibility, support its consideration in resource potential studies and electricity system planning, and contribute to cost-effectiveness evaluations. While practitioners and regulators regularly find opportunities to improve performance assessments of demand-related services, to a large degree current best practices are sufficient for basic service offerings as demand flexibility is implemented today. However, advances in assessment practices will be required in a future with grid-interactive efficient buildings (GEBs) that provide continuous demand flexibility by integrating multiple DERs and flexibility modes (load shed, load shift, modulate, and generate). Example practices include using new baseline constructs—including whether baselines are even required for certain building flexibility modes or configurations, deploying more advanced metering and analytics, further developing cybersecurity standards, improving communication standards for increased interoperability, and establishing performance metrics and assessment procedures for load modulation as it is more fully defined and implemented. This report provides information on prioritizing and designing performance assessment elements for demand flexibility programs and time-varying retail rates, assessment protocols, and research and development needs. Additional research sponsored by DOE’s Building Technologies Office offers more detailed technical information on assessing performance of demand flexibility, including definition of performance metrics.

24 POWER TRANSMISSION AND DISTRIBUTION↗

National Community Solar Partnership Technical Assistance: Together New Orleans [Slides]

This product is the outcome of a National Community Solar Partnership (NCSP) Technical Assistance (TA) request. TA is provided to NCSP members at no cost and upon request. Some TA, this project included, is later generalized and published to help educate the broader community, share findings, and provide best practices. Together New Orleans submitted a TA request to the NCSP aiming to obtain a third-party analysis on several rate compensation structures that could make project development more financially advantageous.

14 SOLAR ENERGY↗

ESPC ESA Webinar Series: ESPC IDIQ Contract Vehicle Overview

This webinar provides instructions and resources for financing distributed energy projects (e.g. on-site renewable energy, storage, and combined heat and power) using an energy savings performance contract (ESPC) energy sales agreement (ESA) through the U.S. Department of Energy (DOE) indefinite-delivery, indefinite-quantity (IDIQ) energy savings performance contract (ESPC) vehicle. The DOE IDIQ ESPC contract vehicle uses a streamlined master contract that allows federal agencies to work with 21 energy service companies holding the current DOE IDIQ ESPC. Topics covered in the webinar include: An overview of the DOE IDIQ contract vehicle; ESA-specific considerations for IDIQ contracts; and Specific use cases. The webinar also provides an overview of the resources available on the Federal Energy Management Program website, such as IDIQ tools and templates. This webinar is the fifth in a series that provides information, best practices, and resources for implementing an ESPC ESA project. ESPC ESAs are a great option for federal sites that are motivated to reduce site costs, have no capital investment funding, and cannot use the U.S. Department of Defense 10 USC 2922a authority for long-term contracting.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

ESPC ESA Webinar Series: ESPC ENABLE Contract Vehicle Overview

This webinar provides instructions and resources for financing distributed energy projects (e.g. on-site renewable energy, storage, and combined heat and power) using an energy savings performance contract (ESPC) energy sales agreement (ESA) through the U.S. Department of Energy's (DOE) ESPC ENABLE contract vehicle. The ESPC ENABLE contract vehicle is a streamlined procurement process that uses a standard investment grade audit tool and standard contract templates. Topics covered in the webinar include: An overview of the ESPC ENABLE contract vehicle; ESA-specific considerations for ENABLE contracts; and Case studies. This webinar also provides an overview of the resources available on the Federal Energy Management Program website, such as ESPC ENABLE templates. This webinar is the fourth of a series that provides information, best practices, and resources for implementing an ESPC ESA project. ESPC ESAs are a great option for federal sites that are motivated to reduce site costs, have no capital investment funding, and cannot use the U.S. Department of Defense 10 USC 2922a authority for long-term contracting.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Municipal Pay-As-You-Throw (PAYT) Programs: Economic Benefits, Limitations, and Best Practices

Pay-as-you-throw (PAYT), also known as unit pricing or variable rate pricing, is a solid waste management system where customers pay for waste collection based on the volume or weight of waste they discard. By linking costs directly to waste generation, PAYT encourages customers to reduce waste through recycling, composting, and source reduction. This approach could support key waste management goals such as waste reduction, increased recycling, and controlling disposal costs. PAYT programs are flexible and can be customized to community needs. When implemented effectively, PAYT may also generate dedicated funding for waste services, enhancing program sustainability and stability.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Small Hydropower Interconnections: Analysis of Interconnection Processes

Small hydropower projects have faced the challenge of navigating the process to interconnect their generation source to electricity distribution and transmission grids. Small hydropower developers have found interconnection procedures to be opaque and ultimately result in unexpected cost surprises and long timelines. Noting these challenges, the U.S. Department of Energy Water Power Technologies Office enlisted Pacific Northwest National Laboratory (PNNL) and Oak Ridge National Laboratory (ORNL) to investigate the small hydropower interconnection landscape across the United States. After reviewing the status of small hydropower (“Small Hydropower Interconnections: Small Hydropower in the United States”) and the interconnection procedures across the United States (“Small Hydropower Interconnections: State Interconnection Processes”) in the first two white papers of this series, this paper uses recent data from small hydropower interconnection applications to benchmark the efficacy of the process. Using data from interconnection queues hosted by utilities, balancing authorities, independent system operators (ISOs), and regional transmission organizations (RTOs), this paper provides context for the costs, timelines, and types of upgrades required for small hydropower projects. Interconnection applications and study reports for small hydropower projects were analyzed to collect key pieces of information about the interconnection process, timeline, costs, and type of upgrades required for interconnection. Information sourced from the reports was entered into an Interconnection Benchmarking database (IBdb), which may be found in Appendix A.1. Information from this database was used to evaluate the performance and challenges associated with interconnecting small hydropower projects. This white paper presents a description of the sources contained in the interconnection database (Section 2.0), an analysis of the interconnection timeline (Section 3.0), an evaluation the cost of interconnection upgrades (Section 4.0), and a description of the types of infrastructure upgrades (Section 5.0). The final paper in this series (“Small Hydropower Interconnections: Best Practices”) will use the analysis described here to outline best practices for interconnection processes that will help overcome barriers to future small hydropower development.

13 HYDRO ENERGY↗

Decommissioning of the V1 Nuclear Power Plant Jaslovske Bohunice - 20270

The paper focuses on introducing the approach and method applied for decommissioning of the V1 nuclear power plant (further the 'V1 NPP') located in Jaslovske Bohunice in the Slovak Republic, to the conference participants. The Paper outlines activities and steps necessary to comply with the requirements contained in the decision of the Slovak government from 1999 regarding the early shutdown of the V1 NPP. The company responsible for the V1 NPP decommissioning is Jadrova a vyradovacia spolocnost, a.s., (further JAVYS) with the State as a sole shareholder. On the basis of the V1 NPP Decommissioning Conceptual Plan, out of four assessed options, JAVYS selected the immediate decommissioning option (the 'IDO') for the V1 NPP. On the basis of multi-criteria analysis, the IDO specified the approach of immediate and continuous dismantling of equipment followed by demolition of buildings and preparation of the site for its further potential use. The IDO also included the summary of technical, environmental, legislative information as well as the determination of assumed costs for decommissioning of the V1 NPP. Prior to commencement of the V1 NPP decommissioning, within the process of termination of operation, activities connected with de-fuelling, monitoring, processing of historical waste and, not to forget, the process of obtaining the license for the V1 NPP decommissioning were executed. JAVYS decided to divide the decommissioning process into two stages. In 2011, JAVYS obtained a license for the first stage of the V1 NPP decommissioning. Within this stage, dismantling of inactive equipment, demolitions of inactive buildings, monitoring of systems and preparatory works for the upcoming stage of decommissioning were implemented. In 2015, in line with the license for the 2. stage of the V1 NPP decommissioning, the activities of decontamination and dismantling of contaminated and active equipment as well as demolitions of remaining buildings began. In this stage radioactive waste (RAW) produced during the decommissioning is to be processed. After decontamination, the material fulfilling the free release criteria is to be released into the environment, the site is to be cleared from the scope of the Atomic Act and released from the surveillance of the national regulators. Future application of certain methods and techniques for decontamination and dismantling in similar environments might bring an added value to the operators. Paper includes a description of best practices for Nuclear Power Plant VVER type reactors decommissioning. Schedule comparison is given to show how the critical path of certain projects is being managed. Application of the International Standard for Decommissioning Costing (ISDC) methodology provides a uniform method which enables comparison of cost estimates to other nuclear facilities under decommissioning. The cost estimate for the V1 NPP decommissioning has been continuously updated based on more advanced and detailed information on the decommissioning activities and projects. Monitoring of progress of the V1 NPP decommissioning is performed via four key-performance indicators. The Earned Value Management (EVM) methodology is used for evaluating time and cost aspect of decommissioning activities while waste conditioning index is calculated by comparing the actually produced waste to planned values of waste for a respective monitored period. Radiological safety index is assessed by comparison of the personnel records on the individual yearly doses received by each respective employee to the boundary value. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Phase Switching as the Origin of Large Piezoelectric Response in Organic-Inorganic Perovskites: A First-Principles Study

Piezoelectrics are critical functional components of many practical applications such as sensors, ultrasonic transducers, actuators, medical imaging, telecommunications. So far, the best performing piezoelectrics are ferroelectric ceramics, many of which are toxic, heavy, hard, and cost-ineffective. Recently, a groundbreaking discovery of extraordinarily large piezoelectric coefficients in the family of organic-inorganic perovskites gave a hope for a cheaper, environmentally friendly, inexpensive, light-weight and flexible alternative. However, the origin of such response in organic-inorganic ferroelectrics whose spontaneous polarization is an order of magnitude smaller than for inorganic counterparts remains unclear. In this study we employ first-principles simulations to predict that the mechanism associated with large piezoelectric constants is of extrinsic origin and associated with switching between the stable phase and previously overlooked energetically competitive metastable phase that can be stabilized by the external stress. Here, the phase switching changes the polarization direction and, therefore, gives origin to large piezoelectric response, similar to PbZr$_{1-x}$Ti$_x$O$_3$ near morphotropic phase boundary. Existence of such metastable phases is likely to manifest as the dynamical molecular disorder above the Curie temperature and, therefore, could be intrinsic to the entire family of organic-inorganic ferroelectrics with such disorder.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The Department of Energy and IDEA team up to document industry best practices

This article describes a collaboration between the U.S. Department of Energy and the International District Energy Association (IDEA) to document best practices in district energy systems. The initiative focuses on analyzing real-world performance data and highlighting effective strategies for improving efficiency, integrating renewable energy, and supporting decarbonization efforts. It highlights case studies from the University of California, Davis, and Princeton University to show how long-term master planning, phased project implementation, and strong financial analysis can drive successful transitions to more sustainable energy systems. U.C. Davis emphasizes incremental, results-driven planning and pilot projects, while Princeton focuses on aligning climate goals with financially viable infrastructure investments and life-cycle cost analysis. Overall, the article demonstrates that combining strategic planning, data-driven decision-making, and financial accountability is essential for advancing sustainable district energy systems.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

A Guide for Creating a Building-Level Action Plan to Manage Refrigerants in Buildings

The Guide for Creating a Building-Level Action Plan to Manage Refrigerants in Buildings has been developed in response to stakeholder feedback and interest received during the Better Buildings Managing Refrigerants Working Group. This guide includes best practices and a step-by-step guide to create a plan to manage their organization's refrigerants. Stakeholders were interested in guidance for refrigerant management to help reduce costs and protect efficiency of equipment, to mitigate risk related to increased maintenance and operational budgets, and to manage costs of using legacy refrigerants.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

COMPOFF: A Compiler Cost model using Machine Learning to predict the Cost of OpenMP Offloading

The HPC industry is inexorably moving towards an era of extremely heterogeneous architectures, with more devices configured on any given HPC platform and potentially more kinds of devices, some of them highly specialized. Writing a separate code suitable for each target system for a given HPC application is not practical. The better solution is to use directive-based parallel programming models such as OpenMP. OpenMP provides a number of options for offloading a piece of code to devices like GPUs. To select the best option from such options during compilation, most modern compilers use analytical models to estimate the cost of executing the original code and the different offloading code variants. Building such an analytical model for compilers is a difficult task that necessitates a lot of effort on the part of a compiler engineer. Recently, machine learning techniques have been successfully applied to build cost models for a variety of compiler optimization problems. In this paper, we present COMPOFF, a cost model which uses the multi-layer perceptrons to statically estimates the Cost of OpenMP OFFloading. We used six different transformations on a parallel code of Wilson Dslash Operator to support GPU offloading, and we predicted their cost of execution on different GPUs using COMPOFF during compile time. Our results show that this model can predict offloading costs with a root mean squared error in prediction of less than 0.5 seconds. Our preliminary findings indicate that this work will make it much easier and faster for scientists and compiler developers to port legacy HPC applications that use OpenMP to new heterogeneous computing environment.

97 MATHEMATICS AND COMPUTING↗

An experimentally informed design process for future inertial confinement fusion facilities

The achievement of ignition in the laboratory has renewed interest in defining the requirements for a future high-gain inertial confinement fusion (ICF) facility. Our best chance of predicting future ICF performance is with 3-D radiation hydrodynamic simulations that have been benchmarked against experimental data, but their high computational cost is prohibitive for use in practical design studies. We introduce a hierarchical approach where 3-D simulations are tuned to match experimental measurements and used to train 3-D degradation models in 1-D simulations allowing for accurate predictions over the entire OMEGA direct-drive database. A genetic algorithm was used in combination with the trained 1-D simulations to search for optimal direct-drive implosion designs at driver energies ranging from 20 kJ to 10 MJ. As the fidelity of 3-D codes improves, this approach will provide a viable experimentally informed tool for defining the next ICF facility.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effect of Fatigue on the Capacity and Performance of Structural Concrete

The goal of this project was to enhance the understanding of the fatigue behavior of concrete structures for the purpose of improving the design and assessment of towers and foundations that support wind turbines, which must endure repeated loadings from wind, waves, operations, and other dynamic effects that cause material degradation. This was achieved through physical experiments, a review of the technical literature, and collaboration with experts in key subject areas. The project produced a comprehensive database of publicly available fatigue data, several technical papers presenting the research findings, and two Technotes to be published by the American Concrete Institute that advance best practices in fatigue testing and enable the development of concrete-specific fatigue (S-N) (stress-life) curves. These contributions are expected to enhance the durability and cost-effectiveness of wind turbine support structures.

17 WIND ENERGY↗

Modeling nuclear energy’s future role in decarbonized energy systems

Increased attention has been focused on the potential role of nuclear energy in future electricity markets and energy systems as stakeholders target rapid and deep decarbonization and reductions in fossil fuel use. This paper examines models of electric sector planning and broader energy systems optimization to understand the prospective roles of nuclear energy and other technologies. In this perspective, we survey modeling challenges in this environment, illustrate opportunities to propagate best practices, and highlight insights from the deep decarbonization literature on the range of visions for nuclear energy's role. Nuclear energy deployment is highest with combinations of stringent emissions policies, nuclear cost reductions, and constraints on the deployment of other technologies, which underscores model dimensions related to these areas. New modeling capabilities are needed to adequately address emerging issues, including representing characteristics and applications of nuclear energy in systems models, and to ensure the relevance of models for policy and planning as deeper decarbonization is explored.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Low-Cost Aero Technology Demonstrations

The main focus of this work was to demonstrate the use of polymeric additive manufacturing (AM) to create tooling for both preforming and consolidation. Polymeric tooling was utilized where both modest and higher pressures are used for part consolidation. The key focus for the AM tooling development was for fabrication of complex structures such as ducting, C-channel stiffened skins, and airfoils where conventional male tooling would typically be trapped in the cured part. The AM tooling was evaluated for use as a tool master used to fabricate and re-shape deformable/re-formable mandrels based on SpinTech’s shape memory composite technology known as Smart Tooling. The AM tooling was also evaluated for use as a mold for composite infusion and consolidation. Key performance parameters were tracked for project schedule completion with each step comprising of “art to part” cycle time, cost, and model fidelity for dimensions, performance, and cost. The primary focus of this demonstration was to determine if a 50% cost reduction was achievable, for each AM tooling-set, as compared to conventional processes. UDRI leveraged project partner SpinTech, who manufactures tools and parts in these categories and thus provided a baseline regarding current best practices and provided valuable feedback during the entirety of this demonstration. This demonstration primarily focused on the use of AM tooling for fabrication of three composite component structures which are typically utilized in aircraft and comprise salient geometric features of broad interest. These components are often tooling intensive and have features requiring extraction of male tools which are usually trapped by the geometry. The three structures selected by the team included: 1) A one-piece airfoil shell comprised of compound contours where male tooling would be trapped unless the part were manufactured in two halves as is typically the case. 2) A one-piece duct used for air handling, comprised of compound contours where male tooling would be trapped unless the part were manufactured in two halves, or a washout mandrel were to be used. 3) A co-cured C-channel stiffened skin where typically C-channels would be individually manufactured and then bonded to a cured skin. The demonstration was comprised of three main tasks: • Task 1: AM Tool Feasibility Study – ensure the AM tooling meets the performance requirements as specified by SpinTech to match baseline performance. • Task 2: Complex Tool Demonstration – Fabricate tooling, preforms, and parts representative of an airfoil and duct. • Task 3: Large Aerostructure Fabrication Demonstration – Fabricate tooling, preforms, and part representative of a C-channel stiffened skin. With the conclusion of this project, a decision tree was developed to determine the key considerations necessary to determine if use of AM tooling for the three selected structures was able to attain the same quality as historically achieved on metallic tooling, while providing a significant cost reduction.

36 MATERIALS SCIENCE↗

Energy Master Planning for Resilient Public Communities—Best Practices from U.S. Military Installations

Until recently, most planners at military installations addressed energy systems for new facilities on an individual facility basis without consideration of community-wide goals relevant to energy sources, renewables, storage, or future energy generation needs. Building retrofits of public buildings typically do not address energy needs beyond the minimum code requirements making it difficult, if not impossible, to achieve community-level targets on a building-by-building basis. Planning on the basis of cost and general reliability may also fail to deliver community-level resilience. For example, many building code requirements focus on hardening to specific threats, but in a multi-building community, only a few of these buildings may be mission-critical. Over the past two decades, the frequency and duration of regional power outages and water utility disruptions from weather, man-made events, and aging infrastructure have increased. Major disruptions of electric and thermal energy have degraded critical mission capabilities and caused significant economic impacts. In 2016, the U.S. Department of Defense issued guidance that each Service (Army, Navy, Air Force, Marines) complete comprehensive energy plans for the installations that consumed 75% of total building energy. Guidance was updated in 2017 to include metrics for energy resilience, and in some cases, water. This paper describes how community level quantitative and qualitative resilience analysis and metrics have been incorporated into community energy and water planning best practices for military installations in three geographically diverse locations. It is based on research performed under the International Energy Agency’s “Energy in Buildings and Communities Program Annex 73,” focusing on development of guidelines and tools that support the planning of Net Zero Energy Resilient Public Communities as well as research performed under the Department of Defense Environmental Security Technology Certification Program project EW18-D1- 5281, “Technologies Integration to Achieve Resilient, Low- Energy Military Installations.” The first case study reviews progress made on an energy and water planning study conducted at Fort Bliss, Texas. The second and third describes planning conducted at Fort Bragg, North Carolina and the Joint Region Marianas, Guam, respectively, under the updated guidance from 2017 regarding energy and water resilience. Analysis methods, key metrics, and key infrastructure and operational constraints are described, as well as technical, economic and business concepts used during the planning process.

Urban, Angela B.↗