Search NASA⌕ Search

SEARCH · Search NASA

Results for “cryocooler”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Cryocooler Electromagnetic Compatibility

Jet Propulsion Laboratory, under joint Ballistic Missile and Defense Organization/Air Force and NASA/Eos Atmospheric Infrared Sounder sponsorship is conducting extensive space cryocooler characterization to provide a reliable and accurate data base on cryocooler performance for use by the space community.

cryocooler electromagnetic compatibility cryocoole↗

Performance Characterization of the Sunpower Cryocooler

The Sunpower 140K cryocooler is an integral in-line single compressor/single displacer configuration that features the use of low friciton gas bearings on all running surfaces. The design is vey compact, simple, and light-weight. This type of cryocooler was originally intended for use in the electronics industry.

cryocooler Sunpower 140K cryocooler↗

Post-Flight Analysis of a 10K Sorption Cryocooler

In May 1996, the Brilliant Eyes Ten-Kelvin Sorption Cryocooler Experiment (BETSCE) was flown aboard the Space Shuttle flight STS-77 in the first space-flight demonstration of chemisorption cryocooler technology. While on orbit, BETSCE successfully met its science objectives of cooling from 70 K to 10 K in less than two minutes, sustaining a 100 mW heat load below 11 K for over then minutes, and demonstrating recycle times of approximately eleven hours.

sorption crycooler chemisorption cryocooler↗

Effect of Heat Rejection Conditions on Cryocooler Operational Stability

It is well known that cryocooler thermal efficiency is a strong function of heat rejection temperature, roughly following the dependency described by carnot. An equally important and generally overlooked implication of cryocooler heat-rejection thermodynamics is the effect of the heat rejection temparature control mode on cyrocooler performance and operational stability.

Cryocooler↗

Investigation of Gas Effects on Cryocooler Resonance Characteristics

Cryocooler thermal and vibrational performance is determined, fundamentally, by the dynamic interactions between the mechanical system and the working fluid. This paper explores the effect of working-fluid characteristics on the mechanical response of the cooler. Experimental data collected from two coolers characterized under the Jet Propulsion Laboratory's extensive program of cryocooler testing and characterization show that a classical single-degree-of-freedom spring-mass-damper model does not capture the full frequency dependence of the mechanical response. The data from the two modes of cooler operation (slosh and head-to-head) are used to motivate the explanation that working-fluid characteristics dominate at high frequencies, and mechanical system characteristics dominate at lower frequencies. Operating temperature is shown to be a significant factor in determining resonance behavior. Finally, the discussion provides a framework within which resonate parameters and cooler characteristics can be extracted from the experimental data.

cryocooler vibration working-fluid characteristics↗

Continuous and Periodic Sorption Cryocoolers for 10 K and Below

A novel system is described for Sorption Cryocooling to 10 K, using hydrogen as refrigerant fluid, sorbent beds of metal hydride powders, and thermal compression and expansion. Current status is summarized of sorption cryocooler development for space applications requiring cooling of infrared and submillimeter sensors to 10 K and below. Several design variations, challenges, and predictions are discussed.

cryogenics↗

NASA space cryocooler programs -- a 2003 overview

Mechanical cryocoolers represent a significant enabling technology for NASA's Earth and Space Science Missions. An overview is presented of ongoing cryocooler activities within NASA in support of current flight projects, near-term instruments, and long-term technology development.

cryocoolers↗

Effects of in-process cryocooling on metallurgical and mechanical properties of friction stir processed Al7075 alloy

Highlights: • For in-process cryocooling (IPC) during FSP, an efficient cooling fixture was designed & fabricated. • FSP of Al7075 alloy with IPC setup suppressed precipitate coarsening as well as grain growth. • Nanosize η′ precipitates (20–30 nm) in IPC condition increased work hardening capacity & strength. • Simultaneous improvement in ductility & strength occurred for sample FSPed with IPC. - Abstract: Friction stir processing (FSP) of heat treatable aluminum alloys is reported to deteriorate strength and hardness properties in spite of huge grain size refinement. The improvement in strength due to the grain size refinement after FSP could not be able to offset the reduction in strength due to coarsening or dissolution of the strengthening precipitate(s). To overcome this, the present work investigates an effective way of heat rejection from the FSP zone to control the precipitate evolution besides the grain size refinement during FSP of Al7075 alloy. The FSP was carried out with standardized process parameters (i.e. 720 rpm, 65 mm/min traverse speed) under two different cooling environments: (i) at normal air cooling and (ii) by rushing a chilled mixture (−30 °C) of liquid nitrogen and methanol through the bottom of the backing plate. Microstructural evolution was examined through optical, scanning and transmission electron microscopy and electron backscatter diffraction to confirm the grain size and morphology of precipitate(s) formed. The in-process cryocooling during the FSP led to 65 and 72% improvement in the Vickers hardness and tensile strength, respectively, in comparison to the solutionized base metal. The results have been analyzed in terms of precipitate interface characteristics and its strengthening effect, Hall–Petch strengthening due to grain size reduction and tradeoff between them.

36 MATERIALS SCIENCE↗

First demonstration of an all-solid-state optical cryocooler

Solid-state optical refrigeration uses anti-Stokes fluorescence to cool macroscopic objects to cryogenic temperatures without vibrations. Crystals such as Yb 3+ -doped YLiF 4 (YLF:Yb) have previously been laser-cooled to 91 K. In this study, we show for the first time laser cooling of a payload connected to a cooling crystal. A YLF:Yb crystal was placed inside a Herriott cell and pumped with a 1020-nm laser (47 W) to cool a HgCdTe sensor that is part of a working Fourier Transform Infrared (FTIR) spectrometer to 135 K. This first demonstration of an all-solid-state optical cryocooler was enabled by careful control of the various desired and undesired heat flows. Fluorescence heating of the payload was minimized by using a single-kink YLF thermal link between the YLF:Yb cooling crystal and the copper coldfinger that held the HgCdTe sensor. The adhesive-free bond between YLF and YLF:Yb showed excellent thermal reliability. This laser-cooled assembly was then supported by silica aerogel cylinders inside a vacuum clamshell to minimize undesired conductive and radiative heat loads from the warm surroundings. Our structure can serve as a baseline for future optical cryocooler devices.

47 OTHER INSTRUMENTATION↗

The Ricor K508 cryocooler operational experience on Mars

The Mars Science Laboratory (Curiosity) landed successfully on Mars on August 5, 2012, eight months after launch. The chosen landing site of Gale Crater, located at 4.5 degrees south latitude, 137.4 degrees east longitude, has provided a much more benign environment than was originally planned for during the critical design and integration phases of the MSL Project when all possible landing sites were still being considered. The expected near-surface atmospheric temperatures at the Gale Crater landing site during Curiosity's primary mission (1 Martian year or 687 Earth days) are from −90°C to 0°C. However, enclosed within Curiosity's thermal control fluid loops the Chemistry and Mineralogy (CheMin) instrument is maintained at approximately +20°C. The CheMin instrument uses X-ray diffraction spectroscopy to make precise measurements of mineral constituents of Mars rocks and soil. The instrument incorporated the commercially available Ricor K508 Stirling cycle cryocooler to cool the CCD detector. After several months of brushing itself off, stretching and testing out its subsystems, Curiosity began the exploration of the Mars surface in October 2012. The CheMin instrument on the Mars Science Laboratory (MSL) received its first soil sample from Curiosity on October 24, and successfully analyzed its first soil sample. After a brief review of the rigorous Ricor K508 cooler qualification tests and life tests based on the original MSL environmental requirements this paper presents final pre-launch instrument integration and testing results, and details the operational data of the CheMin cryocooler, providing a snapshot of the resulting CheMin instrument analytical data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermal performance testing of two Thales 9310 pulse-tube cryocoolers for PHyTIR

PHyTIR is a NASA-funded technology demonstration for a near-term earth-observing instrument in the thermal infrared spectrum, intended for use in the HyspIRI mission. PHyTIR will use two Thales 9310 single-stage pulse tube cryocoolers, one to directly cool the FPA, the other to simulate a passive radiator. We report performance measurements for the two Thales 9310 cryocoolers intended for inclusion in the PHyTIR demonstrator.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sub-millikelvin stabilization of a closed cycle cryocooler

In this study, intrinsic temperature oscillations (with the amplitude up to 1 K) of a closed cycle cryocooler are stabilized by a simple thermal damping system. It employs three different materials with different thermal conductivity and capacity at various temperatures. The amplitude of oscillations of the sample temperature is reduced to less than 1 mK, in the temperature range from 4 K to 300 K, while the cooling power is virtually undiminished. The damping system is small, inexpensive, can be retrofitted to most existing closed cycle cryocoolers, and may improve measurements of any temperature-sensitive physics properties.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Conduction Cooling of a Niobium SRF Cavity Using a Cryocooler

Superconducting Radio Frequency (SRF) cavities are the primary choice for accelerating charged particles in high-energy research accelerators. Institutions like Fermilab use SRF cavities because they enable significantly higher gradients and quality factors than normal-conducting RF cavities and DC voltage cavities. To cool the SRF cavities to low temperatures (typically around 2 K), liquid helium refrigerators are used. Producing and maintaining the necessary liquid helium requires large, elaborate cryogenic plants involving dewars, compressors, expansion engines, and recyclers. The cost, complexity, and space required for such plants is part of the reason that industry has not yet adopted SRF-based accelerators. At the Illinois Accelerator Research Center (IARC) at Fermilab, our team seeks to make SRF technology accessible not only to large research accelerators, but to industry as well. If we eliminate the complexity associated with liquid helium plants, SRF-based industrial accelerators may finally become a reality. One way to do this is to eliminate the use of liquid helium baths altogether and develop a brand-new cooling technique for SRF cavities: conduction cooling using a cryocooler. Recent advances in SRF technology have made it possible to operate SRF cavities at 4 K, a temperature easily achievable using commercial cryocoolers. Our IARC team is taking advantage of this technology to cool SRF cavities.

43 PARTICLE ACCELERATORS↗

Cryocooler conduction-cooled SRF cavities for compact particle accelerators

Cryocooler conduction cooling offers simple, reliable cryogenics for developing industrial SRF e-beam accelerators. Conduction-cooled SRF R&D at Fermilab: first demonstration >6.5 MV/m cw on a 650 MHz Nb 3 Sn coated cavity; prototype development and high power accelerators designs in progress. Cryocooler conduction cooling can greatly expand access to SRF: university groups, industries can embark on in house SRF R&D without needing full stack helium cryogenic systems

43 PARTICLE ACCELERATORS↗

An approach to optimization of low-power Stirling cryocoolers

A method for optimizing the design (shape of the displacer) of low power Stirling cryocoolers relative to the power required to operate the systems is described. A variational calculation which includes static conduction, shuttle and radiation losses, as well as regenerator inefficiency, was completed for coolers operating in the 300 K to 10 K range. While the calculations apply to tapered displacer machines, comparison of the results with stepped displacer cryocoolers indicates reasonable agreement.

Sullivan, D. B.↗

Proceedings of the Third Cryocooler Conference

Mechanical and non-mechanical types of small cryocoolers in the temperature range of 4 to 80 K are discussed. Applications of these small cryocoolers include the cooling of infrared detectors, cryopumps, small superconducting devices and magnets, and electronic devices.

Radebaugh, R.↗