Search NASA⌕ Search

SEARCH · Search NASA

Results for “cryogenic sample”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

C-Term magnetic circular dichroism (MCD) spectroscopy in paramagnetic transition metal and f-element organometallic chemistry

Magnetic circular dichroism (MCD) spectroscopy is a powerful experiment used to probe the electronic structure and bonding in paramagnetic metal-based complexes. While C-term MCD spectroscopy has been utilized in many areas of chemistry, it has been underutilized in studying paramagnetic organometallic transition metal and f-element complexes. From the analysis of isolated organometallic complexes to the study of in situ generated species, MCD can provide information regarding ligand interactions, oxidation and spin state, and geometry and coordination environment of paramagnetic species. The pratical aspects of this technique, such as air-free sample preparation and cryogenic experimental temperatures, allow for the study of highly unstable species, something that is often difficult with other spectroscopic techniques. This perspective highlights MCD studies of both transition metal and f-element organometallic complexes, including in situ generated reactive intermediates, to demonstrate the utility of this technique in probing electronic structure, bonding and mechanism in paramagnetic organometallic chemistry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SIMS CHARACTERIZATION OF NITROGEN DOPING OF LCLS-II-HE PRODUCTION CAVITIES

The thermal diffusion of nitrogen into the surface of niobium has been shown to yield superior low-loss SRF performance. An effective solution was identified and promptly employed in the production of cryomodules for LCLS-II. With added experience and R&D, a modified process was chosen for use in the upgrade for LCLS-II-HE. Largely motivated by this circumstance, supporting research has significantly refined the technique for making calibrated secondary ion mass spectrometry (SIMS) measurements of the N concentration depth profiles produced by production processes. Standardized reference samples were included with four HE production cavities in their N-doping furnace runs. We report the calibrated dynamic SIMS depth profiles of N, C, and O for these samples, together with the cryogenic acceptance test performance of the associated cavities. Interpretation and comparison with similar samples acquired in other furnaces highlights the importance of intentional process quality control of furnace conditions.

Reece, Charles↗

SIMS CHARACTERIZATION OF NITROGEN DOPING OF LCLS-II-HE PRODUCTION CAVITIES

The thermal diffusion of nitrogen into the surface of niobium has been shown to yield superior low-loss SRF performance. An effective solution was identified and promptly employed in the production of cryomodules for LCLS-II. With added experience and R&D, a modified process was chosen for use in the upgrade for LCLS-II-HE. Largely motivated by this circumstance, supporting research has significantly refined the technique for making calibrated secondary ion mass spectrometry (SIMS) measurements of the N concentration depth profiles produced by production processes. Standardized reference samples were included with four HE production cavities in their N-doping furnace runs. We report the calibrated dynamic SIMS depth profiles of N, C, and O for these samples, together with the cryogenic acceptance test performance of the associated cavities. Interpretation and comparison with similar samples acquired in other furnaces highlights the importance of intentional process quality control of furnace conditions.

Reece, Charles↗

Measurement of isotopic abundances in collected stratospheric ozone samples

Enrichment of heavy O3 isotopes has been measured in collected stratospheric samples. A balloon-borne cryogenic sampler was used to gather six O3 samples between 26 and 35 km in three flights. Subsequent laboratory mass spectrometer analysis of rare O3 isotopes at both mass 49 and 50 has resulted in more precise measurements than have previously been reported with in situ and ground-based techniques. In one flight, (O-50)3 was enriched by 12-16 percent and (O-49)3 by 9-11 percent, both increasing with altitude. In the remaining two flights, the isotope enrichment was nearly mass-independent at 8-9 percent. The enrichments in O3 at mass 50 are less than the large 40 percent value observed in some stratospheric measurements but similar to (O-49)3 and (O-50)3 fractionations produced in laboratory-generated ozone.

Schueler, B.↗

Cryogenic Shrouds for Testing Thermal-Insulation Panels

Cryogenic shrouds have been designed and built for use in thermomechanical testing of samples of thermalinsulation panels on cryogenic vessels. In the original application for which these shrouds were specifically designed, the samples are representative of the large-area thermal-insulation panels on the space-shuttle external tanks that hold liquid hydrogen and liquid oxygen, and the purpose of the testing is to demonstrate the ability of bonded layers in the panels to resist delamination under a combination of applied uniaxial mechanical loads and realistic operational temperatures. Presumably, the shrouds and the tests performed by use of them could be modified to enable similar evaluation of thermomechanical properties of thermal-insulation panels for cryogenic vessels other than the external tanks of the space shuttles. The shrouds are required to enable maintenance of required temperatures on the inner and outer surfaces of the thermal-insulation-panel samples, to enable visual observation of the outer surfaces of the samples, and not to introduce any measurable loads into the panels. For each panel sample, there are two shrouds: one to be mounted on the inner surface (the surface that would be in contact with a tank containing a cryogenic liquid during normal use) and one to be mounted on the outer surface (the surface that would be exposed to ambient air or other warmer environment during normal use). The shrouds for testing specimens of thermal-insulation- panels for the liquid-hydrogen tank are made largely of titanium; the shrouds for testing specimens of thermal- insulation-panels for the liquid-oxygen tank are made largely of an aluminum- lithium alloy. The specific temperature requirements are the following: The inner shroud must make it possible to maintain a temperature of 321 degrees F (196 degrees C) [the approximate temperature of liquid nitrogen] or 453 F (about 269 C) [the approximate temperature of liquid helium] on the inner face of the sample. The outer shroud must make it possible to maintain a temperature between 30 degrees and 0 degrees F (between about 34 degrees and about 18 degrees C) on the outer surface of the sample by blowing a cryogenic gas or missile grade air along that surface. To enable viewing of the outer surface of the sample during testing, the outer shroud includes a window comprising two layers of poly(methyl methacrylate) with a gap between them to reduce fogging. To ensure that the shrouds do not introduce any measurable loads into a panel specimen, the shrouds are cushioned on the specimen by seals made of a fluoropolymer-membrane/fabric composite material and are held in place on the specimen by means of symmetrically placed clamps with poly(tetrafluoroethylene) pads. Instrumentation ports for thermocouples and strain gauges used in the tests are incorporated into the shrouds.

Norris, Jeffrey↗

Multistage open-tube trap for enrichment of part-per-trillion trace components of low-pressure (below 27-kPa) air samples

A multistage open-tube trap for cryogenic collection of trace components in low-pressure air samples is described. The open-tube design allows higher volumetric flow rates than densely packed glass-bead traps commonly reported and is suitable for air samples at pressures below 27 kPa with liquid nitrogen as the cryogen. Gas blends containing 200 to 2500 parts per trillion by volume each of ethane and ethene were sampled and hydrocarbons were enriched with 100 + or - 4 percent trap efficiency. The multistage design is more efficient than equal-length open-tube traps under the conditions of the measurements.

Ohara, D.↗

Integrated sample-handling and mounting system for fixed-target serial synchrotron crystallography

Serial synchrotron crystallography (SSX) is enabling the efficient use of small crystals for structure–function studies of biomolecules and for drug discovery. An integrated SSX system has been developed comprising ultralow background-scatter sample holders suitable for room and cryogenic temperature crystallographic data collection, a sample-loading station and a humid `gloveless' glovebox. The sample holders incorporate thin-film supports with a variety of designs optimized for different crystal-loading challenges. These holders facilitate the dispersion of crystals and the removal of excess liquid, can be cooled at extremely high rates, generate little background scatter, allow data collection over >90° of oscillation without obstruction or the risk of generating saturating Bragg peaks, are compatible with existing infrastructure for high-throughput cryocrystallography and are reusable. The sample-loading station allows sample preparation and loading onto the support film, the application of time-varying suction for optimal removal of excess liquid, crystal repositioning and cryoprotection, and the application of sealing films for room-temperature data collection, all in a controlled-humidity environment. The humid glovebox allows microscope observation of the sample-loading station and crystallization trays while maintaining near-saturating humidities that further minimize the risks of sample dehydration and damage, and maximize working times. This integrated system addresses common problems in obtaining properly dispersed, properly hydrated and isomorphous microcrystals for fixed-orientation and oscillation data collection. Its ease of use, flexibility and optimized performance make it attractive not just for SSX but also for single-crystal and few-crystal data collection. Fundamental concepts that are important in achieving desired crystal distributions on a sample holder via time-varying suction-induced liquid flows are also discussed.

47 OTHER INSTRUMENTATION↗

Passive Thermal Coating Observatory Operating in Low-Earth Orbit (PATCOOL)

Long-term presence on the moon, mars, and beyond necessitates the transport of liquid oxygen (LOX). Resources are limited in space and LOX not only servers as an oxidizer for fuel, but can also be utilized in the production of breathable air for space habitats. A cryogenic thermal control coating, developed by scientists at Kennedy Space Center (KSC), is getting ready to demonstrate it has the potential to answer these challenges. Aluminum samples coated with the cryogenic thermal control coating and AZ-93 white paint will be launching to the International Space Station (ISS) and deployed on a CubeSat into a low-earth orbit. This work covers the predicted sample temperatures in a simulated space environment and a review of the Thermal Desktop model.

Cryogenic Thermal Control Coating↗

Comments on the analysis of returned comet samples

It is argued that returned comet samples should be distributed to individual laboratories for analysis much in the same way that lunar samples are. In the context of emerging technologies, certain developments in other fields which may prove beneficial to the study of comets are reviewed, including cryogenic and tomographic techniques. It is noted that the lack of expertise in the area of cryogenic examination of comet samples is a current weakness in the ability of the extraterrestrial material community to handle comet samples and thus requires further training and preparations. Computer tomography scan images of a 'dirty snowball' are presented to illustrate the importance of developing new methods for comet sample analysis. It is suggested that microanalytic measurements of extraterrestrial samples at the atom-counting limit appear promising for the future.

Walker, Robert M.↗

Fabrication and Performance Characterization of Electrospun Nanofibers for Terrestrial and Space Applications

Passive thermal control is vital in space, especially for extended missions involving cryogen storage needing protection from sunlight. This presentation covers the development of a thermal coating with wavelength-selective characteristics using polymeric materials that scatter sunlight with minimal absorption, resulting in high solar reflectance. Furthermore, these coatings allow emission in infrared wavelengths, making them suitable for deep-space missions requiring extended storage. The study chose polymer and surface morphology suitable as solar reflectors that are lightweight, compact, and easily manufacturable, focusing on different multilayered nanofibers made using polytetrafluoroethylene and polyethylene-oxide (PTFE-PEO), polyvinylidene fluoride-hexafluoropropylene (PVDF-HFP), and silica (SiO2). To understand how these materials interact with sunlight, we analyze light propagation through several layers of electrospun nanofibers to determine spectral reflectance, absorptance, and transmittance by solving the Maxwell equations. The model is also compared with measurements of spectral reflectance and transmittance of the various electrospun nanofibers using spectrophotometers interfaced with integrating spheres in the ultraviolet, visible, near-infrared, and mid-infrared wavelengths. The presentation will also describe the design and analysis, fabrication of the nanofibers using electrospinning, and several experimental characterization techniques to determine suitability for space applications. The nanofibers are tested using various tools to determine their suitability for cryogenic applications in space. Lastly, the samples were tested under low vacuum conditions and exposing them to sunlight inside a vacuum chamber maintained at 300 K. Relative to the incoming solar flux (1000 W/m2), only 1% of the energy was absorbed under these operating conditions. With further optimization and testing under high vacuum cryogenic environments, the samples could demonstrate much lower absorption or higher reflection of incoming solar radiation, which can translate to low temperatures suitable for cryogen storage.

Chieloka Ibekwe↗

Performance of a recoverable tug for planetary missions including use of perigee propulsion and corrections for nodal regression

Mathematical equations are derived by using the Maximum Principle to obtain the maximum payload capability of a reusable tug for planetary missions. The mathematical formulation includes correction for nodal precession of the space shuttle orbit. The tug performs this nodal correction in returning to this precessed orbit. The sample case analyzed represents an inner planet mission as defined by the declination (fixed) and right ascension of the outgoing asymptote and the mission energy. Payload capability is derived for a typical cryogenic tug and the sample case with and without perigee propulsion. Optimal trajectory profiles and some important orbital elements are also discussed.

Borsody, J.↗

Performance of a recoverable Tug for planetary missions including use of perigee propulsion and corrections for nodal regression

Mathematical equations are derived by using the Maximum Principle to obtain the maximum payload capability of a reusable Tug for planetary missions. The mathematical formulation includes correction for nodal precession of the Space Shuttle orbit. The Tug performs this nodal correction in returning to this precessed orbit. The sample case analyzed represents an inner planet mission as defined by the declination (fixed) and right ascension of the outgoing asymptote and the mission energy. Payload capability is derived for a typical cryogenic Tug and the sample case with and without perigee propulsion. Optimal trajectory profiles and some important orbital elements are also discussed.

Borsody, J.↗

Design and Comparison of Lunar Sample Return Options

Returning lunar samples to earth is a high priority for NASA in order to better understand Lunar Geology, Lunar formation, and potential resource utilization. Core samples of frozen volatiles from permanently shadowed regions are sought after, but require intensive cryogenic cooling to preserve. Returning samples to Earth using the Orion capsule is restrictive for moderate amounts of mass/volume and thus alternate means of transport are investigated in this paper. The trade-space of potential options includes varying: sample mass amount, sample containment conditions, transfer path from Lunar surface to Earth surface, and various vehicle system trades. An integrated solver is applied with parametric estimators and known system heuristics to effectively estimate size, mass, and power of various subsystems. Modeled subsystems include sample containment, EDL technologies(heat shield, parachute, recovery), power, thermal, avionics, structures, and propulsive systems. Transfer path options include various trajectory options, transfer methods, staging points, and vehicle staging options. A Design of Experiments was conducted to explore the tradespace, to identify sensitivities, and to identify promising designs. Results are detailed for various stakeholder objectives including total mass, sample mass, science return, architecture impacts, and operational flexibility.

Lunar outpost↗

Collecting Ground Samples for Balloon-Borne Instruments

A proposed system in a gondola containing scientific instruments suspended by a balloon over the surface of the Saturn moon Titan would quickly acquire samples of rock or ice from the ground below. Prototypes of a sample-collecting device that would be a major part of the system have been tested under cryogenic and non-cryogenic conditions on Earth. Systems like this one could also be used in non-cryogenic environments on Earth to collect samples of rock, soil, ice, mud, or other ground material from such inaccessible or hazardous locations as sites of suspected chemical spills or biological contamination. The sample-collecting device would be a harpoonlike device that would be connected to the balloon-borne gondola by a tether long enough to reach the ground. The device would be dropped from the gondola to acquire a sample, then would be reeled back up to the gondola, where the sample would be analyzed by the onboard instruments. Each prototype of the sample-collecting device has a sharp front (lower) end, a hollow core for retaining a sample, a spring for holding the sample in the hollow core, and a rear (upper) annular cavity for retaining liquid sample material. Aerodynamic fins at the rear help to keep the front end pointed downward. In tests, these prototype devices were dropped from various heights and used to gather samples of dry sand, moist sand, cryogenic water ice, and warmer water ice.

Jones, Jack↗

Three-Dimensional Mass Spectrometric Imaging of Biological Structures Using a Vacuum-Compatible Microfluidic Device

Three-dimensional (3D) molecular imaging of biological structures is important for a wide range of research. In recent decades, secondary ion mass spectrometry (SIMS) has been recognized as a powerful technique for both two-dimensional (2D) and 3D molecular imaging. Sample fixations (e. g., chemical fixation and cryogenic fixation methods) are necessary to adapt biological samples to the vacuum condition in the SIMS chamber, which has been demonstrated to be non-trivial and less controllable, thus limiting the wider application of SIMS on 3D molecular analysis of biological samples. Our group recently developed in situ liquid SIMS that offers great opportunities for the molecular study of various liquids and liquid interfaces. In this work, we demonstrate that a further development of the vacuum-compatible microfluidic device used in in situ liquid SIMS provides a convenient freeze-fixation of biological samples and leads to more controllable and convenient 3D molecular imaging. The special design of this new vacuum-compatible liquid chamber allows an easy determination of sputter rates of ice, which is critical for calibrating the depth scale of frozen biological samples. Sputter yield of a 20 keV Ar 1800 + ion on ice has been determined as 1500 (± 8%) water molecules per Ar 1800 + ion, consistent with our results from molecular dynamics simulations. Moreover, using the information of ice sputter yield, we successfully conduct 3D molecular imaging of frozen homogenized milk and observe network structures of interesting organic and inorganic species. Finally, taken together, our results will significantly benefit various research fields relying on 3D molecular imaging of biological structures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dynamic Mechanical Analysis of Post-Cured Bismaleimide Resins for Composite-Overwrapped Combustion Chambers Cycled From Cryogenic to High Temperatures

In support of the Rapid Analysis and Manufacturing Propulsion Technology (RAMPT) project, samples made of polybismaleimide (BMI) resin were made and tested under cryogenic conditions. Neat resin samples were tested for multiple cycles, from high temperature (300°C) to cryogenic temperature (-150°C), to replicate the conditions a rocket engine assembly would experience in a test campaign and in operation. To increase the glass transition temperature (and thus mechanical stability), samples were exposed to different post-cure temperatures and were tested using a dynamic mechanical analysis (DMA) instrument. Consistent with expectations, the BMI samples post-cured at higher temperatures generally resulted in higher storage modulus under high temperature test conditions but at the expense of storage modulus values at low temperature test conditions.

Christopher Stelter↗