Search NASA⌕ Search

SEARCH · Search NASA

Results for “cyber attack”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Cyber-Attack Identification of Synchrophasor Data Via VMD and Multifusion SVM

A large amount of synchrophasor data in the wide area measurement system (WAMS) needs to be collected and transmitted to the phasor data concentrator, thereby increasing the possibility of being attacked by hackers. The attacked data are therefore hidden into the normal synchrophasor data so that the synchrophasor data based application will be affected. To remedy this problem, an identification framework is proposed to detect the data cyber-attack in WAMS utilizing variational mode decomposition (VMD) and multifusion support vector machine (MSVM). First, VMD is used to transform the attacked data into multiple modal components. Thereafter, a novel MSVM is employed to classify the deterministic features using the proposed linear combined multikernel (LCM). Further, this LCM can fuse multiple types of features, including the time, frequency, and statistical domains of the synchrophasor data. Utilizing the actual data from FNET/GridEye, different experiments are conducted under multiple attack strengths and types. The results demonstrate that the identification framework has higher precision and robustness compared with other conventional classifiers.

97 MATHEMATICS AND COMPUTING↗

Temporal Cyber Attack Detection.

Rigorous characterization of the performance and generalization ability of cyber defense systems is extremely difficult, making it hard to gauge uncertainty, and thus, confidence. This difficulty largely stems from a lack of labeled attack data that fully explores the potential adversarial space. Currently, performance of cyber defense systems is typically evaluated in a qualitative manner by manually inspecting the results of the system on live data and adjusting as needed. Additionally, machine learning has shown promise in deriving models that automatically learn indicators of compromise that are more robust than analyst-derived detectors. However, to generate these models, most algorithms require large amounts of labeled data (i.e., examples of attacks). Algorithms that do not require annotated data to derive models are similarly at a disadvantage, because labeled data is still necessary when evaluating performance. In this work, we explore the use of temporal generative models to learn cyber attack graph representations and automatically generate data for experimentation and evaluation. Training and evaluating cyber systems and machine learning models requires significant, annotated data, which is typically collected and labeled by hand for one-off experiments. Automatically generating such data helps derive/evaluate detection models and ensures reproducibility of results. Experimentally, we demonstrate the efficacy of generative sequence analysis techniques on learning the structure of attack graphs, based on a realistic example. These derived models can then be used to generate more data. Additionally, we provide a roadmap for future research efforts in this area.

97 MATHEMATICS AND COMPUTING↗

Cyber Attack Sequences Generation for Electric Power Grid

Security assessment of cyber-physical energy systems (CPESs) such as the electric power grid is a critical operation to maintain availability, reliability, and quality of service in the presence of persistent threats from malicious cyber actors. Existing security assessment approaches such as penetration testing and red teaming rely on subject matter expert experience and forensic cyber analysis of historical events to perform realistic, threat-informed assessments of CPES defense. CPESs have a large attack surface because of the heterogeneity and complexity of underlying topology, devices, measurements, and vulnerabilities. The aforementioned approaches lead to partial coverage of the attack surface with a large set of unknown but possible exploits. There is a need to automate the CPES attack surface discovery and contextualize it for relevant, highly probable, real-world attack scenarios. We propose a methodology and framework to facilitate the discovery of the CPES attack surface. We present a multilayer attack graph with ranked attack sequences to describe CPES failure scenarios. We present a work-in-progress framework that lists key components to automate the attack modeling and sequence generation. We demonstrate the published National Electric Sector Cybersecurity Organization Resource CPES failure scenario to highlight the trustworthiness of generated attack sequences.

Dutta, Ashutosh↗

On the Adaptive Protection of Microgrids: A Review on How to Mitigate Cyber Attacks and Communication Failures

One main challenge in the practical implementation of a microgrid is the design of an adequate protection scheme in both grid connected and islanded modes. Conventional overcurrent protection schemes face selectivity and sensitivity issues during grid and microgrid faults since the fault current level is different in both cases for the same relay. Various approaches have been implemented in the past to deal with this problem, yet the most promising ones are the implementation of adaptive protection techniques abiding by the IEC 61850 communication standard. This paper presents a critical review of existing adaptive protection schemes, the technical challenges for the use of classical protection techniques and the need for an adaptive, smart protection system. However, the risk of communication link failures and cyber security threats still remain a challenge in implementing a reliable adaptive protection scheme. A contingency is needed where a communication issue prevents the relay from adjusting to a lower current level during islanded mode. An adaptive protection scheme is proposed that utilizes energy storage (ES) and hybrid ES (HESS) already available in the network as a mechanism to source the higher fault current. Four common grid ES and HESS are reviewed for their suitability in feeding the fault while some solutions are proposed.

25 ENERGY STORAGE↗

Review of internal cyber attacks in nuclear facilities and an artificial neural network model for implementing internal cyberforensics

Deployment of digital technologies within a modern shift in cyber defense systems is essential for protecting the energy production units. One of the important components of defense is cyberforensics: once an attack has been detected to locate its origin. In this paper, a review of well-known cyberattacks in nuclear facilities is provided, with the lessons learned leading to the development of a machine learning approach implementing identification of internal at- tacks in the facility's data networks. Our approach may be seen as one of the layers in a defense-in-depth strategy that identifies if the attack comes from inside, which may result in identifying faster the attacker's origin. The presented model exploits network packet examination to cast accurate predictions on detailing the origin of malicious network connections. The approach fuses multiple mathematical functions within an artificial neural network to provide a response in the form of 0/1, i. e., whether the attack is identified as internal or not. The utilization of a variety of test cases is developed to explore the relevance and validity of the predictive approach. The proposed implementation is examined with network data packet variance, and the results obtained exhibit a highly accurate detection rate.

Nuclear Science & Technology↗

Cyber-attack detection and neutralization

The example embodiments are directed to a system and method for neutralizing abnormal signals in a cyber-physical system. In one example, the method includes receiving input signals comprising time series data associated with an asset and transforming the input signals into feature values in a feature space, detecting one or more abnormal feature values in the feature space based on a predetermined normalcy boundary associated with the asset, and determining an estimated true value for each abnormal feature value, and performing an inverse transform of each estimated true value to generate neutralized signals comprising time series data and outputting the neutralized signals.

97 MATHEMATICS AND COMPUTING↗

Two-Stage Optimization Framework for Detecting and Correcting Parameter Cyber-Attacks in Power System State Estimation

One major tool of Energy Management Systems for monitoring the status of the power grid is State Estimation. Since the results of state estimation are used within the energy management system, the security of the state estimation process is most important. The focus research in this area is on detecting False Data Injection attacks on measurements. While this is important, State Estimation also rely on database that are used to describe the relationship between measurements and systems' states. This paper presents a two-stage programming framework to detect and correct attacks in the parameters of the measurement model used by the state estimation process in the Energy Management System. In the first stage, an estimate of the line parameters ratios are obtained. In the second stage, the estimated ratios from stage I are used in a Bi-Level model for obtaining a final estimate of the measurements' model parameters. Hence, the presented framework does not only unify the detection and correction in a single optimization run, but also provide a monitoring scheme for the SE database that is typically considered static. In addition, in the two stages, linear programming framework is preserved. For validation, the IEEE 118 bus system is used for implementation. The results of this paper illustrate the effectiveness of the proposed model for detecting attacks in the database used in the state estimation process.

state estimation, two-stage optimization, cyber-ph↗

Protecting and Defending against Autonomous Control Systems and Digital Twin Cyber Attacks: Response Strategy for Hyperparameter attacks of Digital Twin Machine Learning Models in Nuclear Power Plants (Final)

Navigating through the complex tapestry of technological advancements, "Response Strategy for Hyperparameter attacks of Digital Twin Machine Learning Model in Nuclear Power Plants" stands at the intersection of cybersecurity and nuclear power plant operations, embarking on a journey through the intricacies of securing digital twins against malicious cyber activities. As nuclear power plants progressively integrate digital twin technology and machine learning models to optimize operations and ensure system reliability, they inadvertently expose themselves to a new spectrum of vulnerabilities, notably in the realm of hyperparameter attacks. Hyperparameters, integral in machine learning model tuning and optimal performance of digital twins, have emerged as a target for adversaries aiming to destabilize the predictive capabilities and therefore, the operational accuracy of these digital entities within critical infrastructures like nuclear plants. This paper, therefore, meticulously threads the needle through the development of a robust response strategy, poised to shield these digital reflections against calculated hyperparameter manipulations, ensuring that the digital twin can effectively and securely function as a reliable proxy for its physical counterpart. The ensuing sections delve into the orchestrated maelstrom of multi-rate time-changing intelligent coordinated hyperparameter attacks and the implementation of event-triggered predictive control, laying down a structured, predictive, and responsive framework that safeguards the nexus where the digital and physical realms of nuclear power plants coalesce. The operational integrity of digital twins in nuclear power plants depends critically on the security of machine learning hyperparameters. This study makes two different contributions. First, a decision-based idea known as a multi-rate time changing intelligent coordinated hyperparameter attack is put forth. In this attack, many hyperparameters are repeatedly changed using both random and intelligent optimal techniques by the attacker. These assaults introduce varied rates at different attack steps, compromise various amounts of hyperparameters, and improve stealth and flexibility. Second, a technique is developed for event triggered predictive control to rapidly respond to potential hyperparameter attacks. This control integrates a sliding window framework, retaining a history of previous data points and employing linear regression to predict the next data point from the current dataset. The control gain K is determined using the Lyapunov-Krasovskii method, and subsequently, an action is developed. Finally, the outcome of the simulation demonstrates the viability of the proposed method for defending nuclear power plant digital twins from hyperparameter attacks.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A Method of Synchrophasor Technology for Detecting and Analyzing Cyber-Attacks

Studying cybersecurity events and analyzing their impacts encourage planners and operators to develop innovative approaches for preventing attacks in order to avoid outages and other disruptions. This work considers two parts in security studies; detecting an integrity attack and examining its effects on power system generators. The detection was conducted through employing synchrophasor technology to provide authentication of ACG commands based on observed system operating characteristics. The examination of an attack is completed via a detailed simulation of a modified IEEE 68-bus benchmark model to show the associated power system dynamic response. The results of the simulation are discussed for assessing the impacts of cyber threats.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Using Structured Intelligence Graph (STIG) to protect our critical infrastructure against cyber attacks [Poster]

STIG is a revolutionary cybersecurity tool developed by researchers at the U. S. Department of Energy's Idaho National Laboratory and it is a software that allows utility owners and operators to easily visualize, create, and edit cyberthreat intelligence information. STIG uses Structured Threat Information eXpression (STIX) and converts complex data on cybersecurity vulnerabilities into a visualization that is easy to understand and act on. With STIG, utility owners and operators have a common system for sharing threat intelligence information, thus increasing the chances of detecting and mitigating cyber exploits before they lead to a cyberattack.

24 POWER TRANSMISSION AND DISTRIBUTION↗