Search NASA⌕ Search

SEARCH · Search NASA

Results for “cyber security controls”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Cyber–physical vulnerability and resiliency analysis for DER integration: A review, challenges and research needs

High penetration of renewable and sustainable Distributed Energy Resources (DER) into the traditional distribution system requires a well-coordinated control strategy for the improvement of system-wide reliability and resiliency. Implementation of such a holistic control architecture requires a flexible, near real-time, and bi-directional communication framework for facilitating the participation of various agents in a multi-vendor heterogeneous smart grid. While the sustainability of energy generation is ensured, this exposes the smart grid to extrinsic cyber threats, and appropriate defense mechanism(s) must be deployed to guarantee continued reliability and resiliency of the power grid. Further, the comprehensive literature review presented in this paper discusses the latest trends in the DER control schemes with fast communication requirements and their accompanying cyber–physical vulnerabilities. These control schemes are compared and contrasted for various traits. A three-level DER system architecture has been depicted, facilitating the deployment of these control schemes. The current developments of standard communication protocols, key security mechanisms, and best practices along major standards and guidelines are explored. The impacts of different attack types with miscellaneous DER functions based on various control schemes and associated mitigation solutions are also provided. Finally, challenges and future research directions for limiting cyber-power susceptibility to enhance resiliency are summarized. The work presented here will help us enabling a cyber-resilient and sustainable smart electric grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

CRITICAL FUNCTION ASSURANCE: Understanding Critical Function and Critical Function Delivery is Foundational for Meaningful ICS Security Improvement and Policy Efforts

Modern life is enabled by a complex and interdependent web of critical functions, including energy, communications, transportation, food, and water. Automation has significantly reduced or replaced human interactions in the delivery of these functions, resulting in a web of goods and services that are made available 24/7 only through unique and intentional deployments of microprocessors, software, and firmware technologies. The prospect of cyber-enabled sabotage of these processes disrupts traditional risk determination models. Critical Function Assurance (CFA) is a foundational approach to identifying, prioritizing, and mitigating the risk that is inherent in the delivery of critical functions that depend on digital technology. It provides rapid focus to what matters most and illuminates elements and areas of risk that otherwise are often overlooked. This focus enables effective application of available security resources and optimizes security strategy and policy efforts. This paper introduces CFA to decision makers and risk executives (including CEOs, COOs, CFOs, and CISOs) whose organizations support and deliver the critical functions that underpin national defense, societal health and safety, and a vibrant economy.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

CyTRICS: Vulnerability Analysis Tailored for Critical Infrastructure

Society and modern life are dependent on critical infrastructure that is composed of expensive, special purpose devices that have long life cycles and may be in use for decades before being replaced. There are an abundance of organizations and individuals doing vulnerability analysis on a variety of systems, but what makes the Cyber Testing for Resilient Industrial Control Systems (CyTRICS) program unique and valuable is its strategic focus on high-priority critical infrastructure, close partnership with vendors, and ability to leverage bills of materials (BOMs) to identify and relate vulnerabilities to affected systems. Creating a bill of materials is a formal way of understanding and documenting the components of a system, including everything from integrated circuits to operating systems to third-party libraries. This is beneficial for connecting known vulnerabilities to affected devices, since vulnerabilities in a specific component are often not mapped to all systems that use that vulnerable component. Additionally, CyTRICS finds novel vulnerabilities through its vulnerability testing process and works closely with vendor partners to provide vulnerability reports so that affected systems can be patched in a timely manner. This presentation will describe the interrelated technical processes CyTRICS uses to create bills of materials and conduct vulnerability analysis.

99 GENERAL AND MISCELLANEOUS↗

Automated Programmable Logic Controller Memory Forensics Using RGB Image Analysis and Deep Learning

The introduction of Industry 4.0 and Internet-based technologies has enhanced industrial control system operations but have inadvertently increased their vulnerabilities to cyber attacks. When an industrial control system is compromised, security analysts need to identify the root cause quickly to start the recovery process and develop mitigation strategies. Memory forensics is critical in the incident analysis process to ascertain what occurred. Approaches for analyzing the persistent memory in industrial control devices are limited and almost nonexistent for volatile memory. This chapter proposes an automated methodology for programmable logic controller memory dump analysis using computer vision and deep learning techniques. The methodology converts the sequences of bytes in a programmable logic controller memory dump to red-green-blue pixels and employs a deep learning model that learns the underlying patterns and features of pre-labeled forensic artifacts in images and segments them into distinct regions. The trained model is employed to automatically segment new memory images and identify forensic artifacts. Evaluation of the methodology on a Schneider Electric Modicon M221 programmable logic controller under code injection and code modification attacks demonstrates its ability to detect attack artifacts in memory dumps.

Asmar Awad, Rima [ORNL] (ORCID:0000000233407742)↗

Cyber-Physical Smart Light Control System Integration with Smart Grid using Zigbee

This paper presents a hardware-in-the-loop cyber-physical system architecture design to monitor and control smart lights connected to the active distribution grid. The architecture uses Zigbee-based (IEEE 802.15.4) wireless sensor networks and publish-subscribe architecture to exchange monitoring and control signals between smart-light actuators (SLAs) and a smart-light central controller (SLCC). Each SLA integrated into a smart light consists of a Zigbee-based endpoint module to send and receive signals to and from the SLCC. The SLCC consists of a Zigbee-based coordinator module, which further exchanges the monitoring and control signals with the active distribution management system over the TCP/IP communication network. The monitoring signals from the SLAs include light status, brightness level, voltage, current, and power data, whereas, the control signals to the SLAs include light intensity, turn ON, turn OFF, standby, and default settings. We have used our existing hardware-in-the-loop (HIL) cyber-physical system (CPS) security SCADA testbed to process signals received from the SLCC and respond suitable control signals based on the smart light schedule requirements, system operation, and active distribution grid dynamic characteristics. We have integrated the proposed cyber-physical smart light control system (CPSLCS) testbed to our existing HIL CPS SCADA testbed. We use the integrated testbed to demonstrate the efficacy of the proposed algorithm by real-time performance and latency between the SLCC and SLAs. The experiments demonstrated significant results by 100% realtime performance and low latency while exchanging data between the SLCC and SLAs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Epistemology of voltage control in DER-rich power system

Despite the recent development of several scalable, robust, and resilient control approaches with superior convergence properties considering an increasing penetration of distributed energy resources (DERs), cognitive oversights often simplify several aspects of the cyber–physical power system in the controller development. Here, following the identification of the limitations of classical controller definitions, we justify alternative definitions of voltage control approaches classifiers considering three inter-disciplinary domains: (i) power system, (ii) optimization and decision-making, and (iii) networking and cyber-security, to develop a taxonomy for helping in real-world comparative performance analysis and deployability of these controllers. We observe that classical and introduced domain-based definitions together can better classify the control algorithms.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A High-Fidelity Cyber-Physical Testbed-Based Benchmarking Dataset For Testing Operational Technology Specific Intrusion Detection Systems

Quality datasets serve a critical purpose in cyber security research. Data is needed to understand system behavior and develop security controls to protect critical systems. However, for critical infrastructure operational environments there is a lack of available datasets to study because of the high cost and specialized capabilities necessary to generate them. This paper documents the development of a dataset of high fidelity hardware in the loop laboratory simulated models of electric and natural gas distribution systems with real cyber attack test cases. A deep dive discussion for the experimental setup and controls for generating the data is provided along with observations from using the data in evaluating intrusion detection approaches.

Ashok, Aditya↗

Cyber-Physical Power Systems Protection: The Byzantine Cybersecurity Framework

Cybersecurity of smart grids have been topic of much interest in recent years. As this critical infrastructure operation increases dependency on automated processes and controls, exposure to cyber-physical threats become inevitable. Considering cyber-physical security of the grid, much focus of attention has been made towards smart grids real-time monitoring solutions, including the state estimation process. Analyzing the relevant literature, one can note though that seldom research has been done on cyber-physical security of smart grids protection systems. Protection systems have intangible value towards grid reliability. This paper presents a cybersecurity framework for smart grids protection systems. A physics-based inspired machine learning solution is at the core process of the framework. Processed relay inputs and outputs are used by a deep predictive coding network. Formal models, a quasi-static state estimator, provides an oracle when low confidence decision is reached. Evolving knowledge is derived through reinforcement learning. Implementation aspects considering the Pacific Northwest National Laboratory Electricity Infrastructure Operations Center are presented. Built as an extra control layer to protection systems, without hard-to-derive parameters, highlights potential aspects towards real-life applications.

Bretas, Arturo Suman↗

Resilient State Recovery Using Prior Measurement Support Information

Resilient state recovery of cyber-physical systems has attracted much research attention due to the unique challenges posed by the tight coupling between communication, computation, and the underlying physics of such systems. By modeling attacks as additive adversary signals to a sparse subset of measurements, this resilient recovery problem can be formulated as an error correction problem. To achieve exact state recovery, most existing results require less than 50% of the measurement nodes to be compromised, which limits the resiliency of the estimators. In this paper, we show that observer resiliency can be further improved by incorporating data-driven prior information. Here, we provide an analytical bridge between the precision of prior information and the resiliency of the estimator. By quantifying the relationship between the estimation error of the weighted ℓ 1 observer and the precision of the support prior, this quantified relationship provides guidance for the estimator’s weight design to achieve optimal resiliency. Several numerical simulations and an application case study are presented to validate the theoretical claims.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Distributed Energy Resource Cybersecurity Framework Best Practices

Current cybersecurity challenges for distributed energy resources (DERs) stem from the integration of various systems and the cyber-physical security concerns they bring. Although frameworks exist for industrial control systems and other energy systems, a simple guided tool that can prioritize recommended actions for controls specific to DERs is lacking. Additionally, the novelty of the field has made it difficult to create a standardized procedure for DERs with cybersecurity in mind. In response to this critical need to address cybersecurity risk management, the National Renewable Energy Laboratory (NREL) has developed a framework and accompanying web application known as the Distributed Energy Resources Cybersecurity Framework (DERCF) (Powell, 2019). A brief overview of the DERCF can be found in Section 1.2. This document provides a guide to cybersecurity best practices identified by technical research and site visits where the framework was used to assess the cybersecurity posture of DER systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Security Architecture for Microgrid Integration

The purpose of this document is to present cyber security risk considerations and mitigations for community microgrids. The mitigations discussed herein specifically focus on cyber security technical requirements for the De-centralized Autonomous Community Controller (DAC) as part of the SECURE project’s technology development effort. These requirements also consider the associated security implementation challenges involved with the decentralized characteristics of microgrids where upstream communications to utility security management functions are lost. These security recommendations and technical requirements may be used by microgrid implementers and technology vendors to specify the security design of the microgrid systems and their components.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Protecting and Defending against Autonomous Control Systems and Digital Twin Cyber Attacks: Response Strategy for Hyperparameter attacks of Digital Twin Machine Learning Models in Nuclear Power Plants (Final)

Navigating through the complex tapestry of technological advancements, "Response Strategy for Hyperparameter attacks of Digital Twin Machine Learning Model in Nuclear Power Plants" stands at the intersection of cybersecurity and nuclear power plant operations, embarking on a journey through the intricacies of securing digital twins against malicious cyber activities. As nuclear power plants progressively integrate digital twin technology and machine learning models to optimize operations and ensure system reliability, they inadvertently expose themselves to a new spectrum of vulnerabilities, notably in the realm of hyperparameter attacks. Hyperparameters, integral in machine learning model tuning and optimal performance of digital twins, have emerged as a target for adversaries aiming to destabilize the predictive capabilities and therefore, the operational accuracy of these digital entities within critical infrastructures like nuclear plants. This paper, therefore, meticulously threads the needle through the development of a robust response strategy, poised to shield these digital reflections against calculated hyperparameter manipulations, ensuring that the digital twin can effectively and securely function as a reliable proxy for its physical counterpart. The ensuing sections delve into the orchestrated maelstrom of multi-rate time-changing intelligent coordinated hyperparameter attacks and the implementation of event-triggered predictive control, laying down a structured, predictive, and responsive framework that safeguards the nexus where the digital and physical realms of nuclear power plants coalesce. The operational integrity of digital twins in nuclear power plants depends critically on the security of machine learning hyperparameters. This study makes two different contributions. First, a decision-based idea known as a multi-rate time changing intelligent coordinated hyperparameter attack is put forth. In this attack, many hyperparameters are repeatedly changed using both random and intelligent optimal techniques by the attacker. These assaults introduce varied rates at different attack steps, compromise various amounts of hyperparameters, and improve stealth and flexibility. Second, a technique is developed for event triggered predictive control to rapidly respond to potential hyperparameter attacks. This control integrates a sliding window framework, retaining a history of previous data points and employing linear regression to predict the next data point from the current dataset. The control gain K is determined using the Lyapunov-Krasovskii method, and subsequently, an action is developed. Finally, the outcome of the simulation demonstrates the viability of the proposed method for defending nuclear power plant digital twins from hyperparameter attacks.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

On the Limits of EM Based Detection of Control Logic Injection Attacks In Noisy Environments

The difficulty in applying traditional security mechanisms in Industrial Control System (ICS) environments makes a large portion of these mission-critical assets vulnerable to cyber attacks. Therefore, there is a dire need for the development of novel security mechanisms specifically designed to protect such critical systems. Recently a lot of attention has been given to mechanisms that exploit the EM emanations of devices for defense purposes. Such practices may lead to the development of robust external and non-intrusive anomaly detection systems. Nevertheless, the majority of current work in the area neglects to consider the implications of real-life environments, particularly environmental noise. In this work, we explore the limits of EM-based anomaly detection towards identifying injection attacks in control logic software in noisy environments. Our study conducted upon both synthetically generated and real signals identified that indeed environmental noise might significantly degrade the accuracy of the anomaly detection process. Experiments done upon synthetic data indicated that assuming that signals are captured with high sampling rates, even minor code injections can be detected with above-90% accuracy in noisy environments where SNR is up to -2dB. This is true even if naive detection methods are considered. Moreover, experiments done using a real-life testbed attest that even single-instruction injections can be detected with near-perfect accuracy in relatively clean environments. Finally, noise-elimination techniques can drastically improve the reliability of the detection mechanism even in noisy environments.

97 MATHEMATICS AND COMPUTING↗

IEEE PES GM Poster - Cyber-Informed Engineering Approach to Mitigating BESS Supply Chain Concerns

Battery energy storage systems (BESS) are increasingly important to meet the needs of grid resilience and reliability. BESS provide critical grid services, maintaining stability of the grid with increased variable conditions. However, there are significant geopolitical and security concerns regarding their operation in critical infrastructure, due to lack of a domestic supply chain and prevalence of foreign entity of concern (FEOC) components in BESS and associated inverter-based resources. The supply chain challenge is dually exacerbated by a lack of alternative suppliers who can meet the economic targets for energy delivery and a potentially adversarial supply chain. Solutions are needed to secure components, addressing mixed layers of risk and engineering controls. This paper presents a specific application of Cyber-Informed Engineering (CIE) principles for BESS and recommends an alternative strategy to blocking the supply chain, ensuring that grid modernization targets can be met despite lack of a validated or secure supply chain. This study focuses on the United State (U.S.) use case, but the process can be applied globally to address supply chain security challenges. CIE practices represent the next step in functional assurance and risk mitigation, ensuring optimal resource allocation and enhancing security measures to safeguard the future of energy in the U.S. and beyond.

25 - ENERGY STORAGE↗

Autonomous Tools for Attack Surface Reduction (Final Report)

The electric power grid is a complex critical infrastructure that forms the lifeline of modern society, and its secure and reliable operation is of paramount importance to national security and economic wellbeing. However, recent findings documented in authoritative sources indicate the threat of cyber-based attacks growing in numbers and sophistication. However, securing the grid against stealthy cyberattacks is a challenging task due to legacy nature of the infrastructure coupled with dynamic nature of threat landscape and ever-growing sophistication of the adversaries. Additionally, the grid’s attack surface continues to grow with the increased dependence on digital communications and control that now extends to each consumer through smart meters and distributed energy resources. Unfortunately, this expansive surface increases the grid’s vulnerability and further exposes critical control systems in both substations and control centers. To respond to this emerging need, we had successfully assembled an interdisciplinary team with academic- industry partnership to successfully conduct research, development, evaluation, demonstration, and commercialization of attack surface reduction tools, whose goal was to significantly reduce the cyber attack surface in the North American power grid. Our proposed project was a synergistic collaborative effort leveraging the synergistic expertise of the team members across power systems, cyber security and CPS security, testbeds, field deployments and demonstration, and successful commercialization. The following are the specific tasks that have been successfully completed two phases (2016-2020). Phase I: Task 1: Developed and implemented a robust Project Management and Data Management Plan, coupled with a well thought out Risk Mitigation Plan. Task 2.1: Developed a comprehensive framework that continually assesses and autonomously reduces the attack surface for the power grid control environment spanning across substations, control center and the SCADA network to significantly reduce the risks of cyber attacks. Task 2.2: Developed attack surface analysis techniques, metrics, and tools that assess the attack surface at multiple levels including the control center, substations, and the SCADA network. Task 2.3: Developed attack surface reduction techniques and tools that dynamically reduce attack surface and hence increase attacker’s cost without interfering in the critical functions of the system. Task 2.4: Prototyped, implemented, and quantitatively evaluated/validated the techniques and tools on a realistic industrial CPS security testbed environment by leveraging the unique resources of the team. Task 3: Developed Commercialization plan to transition the developed tools into power system industry stakeholders for a broader adoption by leveraging the expertise of our industrial members. Phase II: Task 4: Successfully completed field demonstration, verification, and evaluation of the effectiveness of the attack surface analysis and reduction techniques on a realistic utility testbed environment. This also involved the development of realistic scenarios, sound metrics, data sets, evaluation criteria, and documentation. Technology integration & Field demonstration: The project had significantly advanced the state-of-the-art research and practice in improving the cybersecurity of our nation’s power grid infrastructure against cyber threats. In particular, the proposed, designed, and deployed attack surface analysis and reduction algorithms and tools have contributed to significantly reducing the exposure and risk of the devices, substations, and the integrated SCADA/EMS/ DMS grid environment to cyber threat. Strong demonstration and evaluation techniques have verified the feasibility of the developed techniques on realistic cyber-physical testbeds and utility partner's real grid environment, and collaborative research and evaluation of attack surface reduction techniques (for wide-are monitoring and control) within a vendor (GE) EMS platform. The Attack Host Analyzer (AHA) tool that was developed through this project was made available through GitHub.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Enhancing grid reliability and resilience through novel DER control, total situational awareness and integrated distribution-transmission representation

High penetration of distributed energy resources (DERs) can lead to overvoltage and thermal violations, miscoordination of protection devices and potential adverse control interactions. The challenges are exacerbated by a lack of operator situational awareness of behind-the-meter DERs, and T&D interactions. Furthermore, the large attack surface of a DER environment creates significant cyber security challenges. The motivation is to address these barriers. The main goal is to enable extreme levels of DERs in distribution systems while simultaneously enhancing their reliability and resiliency. This is achieved by a data-driven approach for operation, planning and control of distribution systems with total situational awareness and real-time DER control enabled by a network of edge intelligent devices, a cloud-based analytical platform, and secure communications.

14 SOLAR ENERGY↗

Virtualizing Industrial Control Networks for Cyber Resilience Experiments

Industrial control systems (ICS) networks are undergoing constant shifts to accommodate new security measures. It is challenging to test varying network configurations and security tools with physical systems as they typically include large, expensive equipment. Not only this, but researchers often do not have access to this type of equipment for development of new security tools and techniques. As a solution to these issues, this work presents a set of tools for utilizing GNS3 and Docker as a virtual ICS network. Additionally, the virtual network can be attached to physical devices including network switches, hardware simulations, and intelligent electronic devices (IEDs). Two case studies showcase a relatively complex automatically generated network and an attack on a simple ICS network with an example mitigation.

42 ENGINEERING↗