Performance of filament-wound vessels from an organic fiber in several epoxy matrices

A study was carried out to select a state-of-the-art epoxy for wet filament winding. Ten epoxy systems were used to filament wind pressure vessels with a high-modulus, high-strength organic fiber. Data are reported on vessel performance, fiber strand strengths, and shear strengths for the different systems. Using our criteria (processibility, neat resin properties, and vessel performance), we find that an epoxy system based on the rubber-modified bis-phenol-F resin, diluted with vinyl cyclohexane dioxide and cured with mixed aromatic amines, can easily replace bis-phenol-A epoxies diluted with bis-(2, 3-epoxycyclopentyl) ether (such as ERL 2256 epoxy of Union Carbide) with comparable overall performance.

Chiao, T. T.↗

Calibration of longwavelength exotech model 20-C spectroradiometer

A brief description of the Exotech model 20-C field spectroradiometer which measures the spectral radiance of a target in the wavelength ranges 0.37 to 2.5 microns (short wavelength unit), 2.8 to 5.6 microns and 7.0 to 14 microns (long wavelength unit) is given. Wavelength calibration of long wavelength unit was done by knowing the strong, sharp and accurately known absorption bands of polystyrene, atmospheric carbon dioxide and methyl cyclohexane (liquid) in the infrared wavelength region. The spectral radiance calibration was done by recording spectral scans of the hot and the cold blackbodies and assuming that spectral radiance varies linearly with the signal.

Kumar, R.↗

Ultraviolet absorption of common spacecraft contaminants

Organic contamination of ultraviolet optical systems is discussed. Degradation of signal by reflection, scattering, interference, and absorption is shown. The first three processes depend on the physical state of the contaminant while absorption depends on its chemical structure. The latter phenomenon is isolated from the others by dissolving contaminants in cyclohexane and determining absorption spectra from 2100A to 3600A. A variety of materials representing the types of contaminants responsible for most spaceflight hardware problems is scanned and the spectra is presented. The effect of thickness is demonstrated for the most common contaminant, di(2 ethyl hexyl)phthalate, by scanning successive dilutions.

Colony, J. A.↗

Calibration of long wavelength Exotech model 20C spectroradiometer

A brief description of the Exotech model 20C field spectroradiometer, which measures the spectral radiance of a target in the wavelength ranges from 0.37 to 2.5 microns (short wavelength unit), 2.8 to 5.6 microns, and 7.0 to 14 microns (long wavelength unit) is given. It is a rugged field instrument which uses four circular-variable-filters to get wavelength scan. Wavelength calibration of the long wavelength unit was done by use of the strong, sharp, and accurately known absorption bands of polystyrene, atmospheric carbon dioxide, and methyl cyclohexane (liquid) in the IR wavelength region. The spectral radiance calibration was done by recording spectral scans of the hot and the cold blackbody targets and assuming that spectral radiance varies linearly with the signal.

Kumar, R.↗

A fundamental approach to adhesion: Synthesis, surface analysis, thermodynamics and mechanics

The acid-base properties of titanium 6-4 plates (low surface area) were investigated after three different pretreatments, namely Turco, phosphate-fluoride and Pasa-Jell. A series of indicators was used and color changes were detected using diffuse reflectance visible spectroscopy. Electron spectroscopy for chemical analysis was used to examine the indicator on the Ti 6-4 surface. Specular reflectance infra-red spectroscopy was used to study the adsorption of stearic acid from cyclohexane solutions on the Ti 6-4 surface.

Siriwardane, R.↗

Prepolymer Syrup for Encapsulating Solar Cells

Clear polymer syrup, made by disolving n-butyl acrylate prepolymer in monomer, used to encapsulate solar cells by any of three standard processes (dipping, multiple coating, or automated machine coating). Use of cyclohexane instead of methanol/water solvent during initial polymerization stage maintains high molecular weight and raises yield of linear polymer to essentially 100 percent.

Gupta, A.↗

Effect of deoxygenation and prestressing on hydrocarbon fuel thermal stability

A jet fuel thermal oxidation tester was used to study the effect of deoxygenation and deoxygenated prestressing on deposit formation when hydrocarbon fuels are thermally stressed. Four pure hydrocarbons (n-decane, cyclohexane, benzene and 1-hexene) and two mixtures (10 percent tetralin in n-dodecane and commercial Jet A) were used at temperatures of 250 C to 400 C. Deoxygenation decreased deposit formation for cycloheaxane but increased it for benzene. Deoxygenation decreased deposit formation for the two fuel mixtures at 250 C but had no effect at 350 C. Deoxygenated prestressing either increased or decreased deposit formation depending on the fuel used and the temperature.

Bittker, D. A.↗

Polymers in solar energy utilization

A laser photoacoustic technique (LPAT) has been verified for performing accelerated life testing of outdoor photooxidation of polymeric materials used in solar energy applications. Samples of the material under test are placed in a chamber with a sensitive microphone, then exposed to chopped laser radiation. The sample absorbs the light and converts it to heat by a nonradiative deexcitation process, thereby reducing pressure fluctuations within the cell. The acoustic signal detected by the microphone is directly proportional to the amount of light absorbed by the specimen. Tests were performed with samples of ethylene/methylacrylate copolymer (EMA) reprecipitated from hot cyclohexane, compressed, and molded into thin (25-50 microns) films. The films were exposed outdoors and sampled by LPAT weekly. The linearity of the light absorbed with respect to the acoustic signal was verified.Correlations were established between the photoacoustic behavior of the materials aged outdoors and the same kinds of samples cooled and heated in a controlled environment reactor. The reactor tests were validated for predicting outdoor exosures up to 55 days.

Liang, R. H.↗

Polyvinyl alcohol coating of polystyrene inertial confinement fusion targets

An inertial confinement fusion (ICF) target made of polystyrene is first levitated in an acoustic field. The surface of the target is then etched using an appropriate solution (e.g., cyclohexane) to enhance the wetting characteristics. A specially prepared polyvinyl alcohol solution is atomized using an acoustic atomizer and deposited on the surface of the target. The solution is air dried to form a thin coating (2 microns) on the target (outside diameter of about 350-850 microns). Thicker coatings are obtained by repeated applications of the coating solutions. Preliminary results indicate that uniform coatings may be achievable on the targets with a background surface smoothness in the order of 1000 A.

Annamalai, P.↗

Precise Viscosity Measurements Very Close to Critical Points

A torsion oscillator is being developed to measure the viscosity of fluids at moderate temperatures (0-100 C) and pressures (0-10 MPa) at very low frequencies (0.5 Hz) and very low shear rates (0.05/sec). These conditions are required to measure the shear viscosity of fluids extremely close to the critical point. The oscillator, thermostat, vacuum system, and instrumentation were assembled and are undergoing debugging. Preliminary measurements indicate that the system has a noise corresponding to 0.2% of the viscosity of methanol-cyclohexane mixtures near the consolute point.

Moldover, M. R.↗

Temperature and velocity profiles in sooting free boundary layer flames

Temperature and velocity profiles are presented for cyclohexane, n-heptane, and iso-octane free, laminar, boundary layer, sooting, diffusion flames. Temperatures are measured with 3 mil Pt/Pt-13 percent Rh thermocouples. Corrected gas temperatures are derived by performing an energy balance of convection to and radiation from the thermocouple bead incorporating the variation of air conductivity and platinum emissivity with temperature. Velocities are measured using laser doppler velocimetry techniques. Profiles are compared with previously reported analytic temperature and velocity fields. Comparison of theoretical and experimental temperature profiles suggests improvement in the analytical treatment is needed, which accounts more accurately for the local soot radiation. The velocity profiles are in good agreement, with the departure of the theory from observation partially due to the small fluctuations inherent in these free flows.

Ang, J. A.↗

Velocity profiles in laminar diffusion flames

Velocity profiles in vertical laminar diffusion flames were measured by using laser Doppler velocimetry (LDV). Four fuels were used: n-heptane, iso-octane, cyclohexane, and ethyl alcohol. The velocity profiles were similar for all the fuels, although there were some differences in the peak velocities. The data compared favorably with the theoretical velocity predictions. The differences could be attributed to errors in experimental positioning and in the prediction of temperature profiles. Error in the predicted temperature profiles are probably due to the difficulty in predicting the radiative heat losses from the flame.

Lyons, Valerie J.↗

Critical exponent for the viscosity of four binary liquids

The viscosity of the following binary mixtures was measured near their consolute points: (1) methanol + cyclohexane, (2) isobutyric acid + water, (3) nitroethane + 3-methylpentane, and (4) 2-butoxyethanol + water. It is shown that the multiplicative hypothesis is valid for these mixtures. It is also found that the concentration closest to critical has the largest viscosity enhancement.

Berg, Robert F.↗

Critical point wetting drop tower experiment

The 100 m Drop Tower at NASA-Marshall was used to provide the step change in acceleration from 1.0 to 0.0005 g. An inter-fluid meniscus oscillates vertically within a cylindrical container when suddenly released from earth's gravity and taken into a microgravity environment. Oscillations damp out from energy dissipative mechanisms such as viscosity and interfacial friction. Damping of the oscillations by the later mechanism is affected by the nature of the interfacial junction between the fluid-fluid interface and the container wall. In earlier stages of the project, the meniscus shape which developed during microgravity conditions was applied to evaluations of wetting phenomena near the critical temperature. Variations in equilibrium contact angle against the container wall were expected to occur under critical wetting conditions. However, it became apparent that the meaningful phenomenon was the damping of interfacial oscillations. This latter concept makes up the bulk of this report. Perfluoromethyl cyclohexane and isopropanol in glass were the materials used for the experiment. The wetting condition of the fluids against the wall changes at the critical wetting transition temperature. This change in wetting causes a change in the damping characteristics of the interfacial excursions during oscillation and no measurable change in contact angle. The effect of contact line friction measured above and below the wetting transition temperature was to increase the period of vertical oscillation for the vapor-liquid interface when below the wetting transition temperature.

Kaukler, William F.↗

Evaluation of on-board hydrogen storage methods f or high-speed aircraft

Hydrogen is the fuel of choice for hypersonic vehicles. Its main disadvantage is its low liquid and solid density. This increases the vehicle volume and hence the drag losses during atmospheric flight. In addition, the dry mass of the vehicle is larger due to larger vehicle structure and fuel tankage. Therefore it is very desirable to find a fuel system with smaller fuel storage requirements without deteriorating the vehicle performance substantially. To evaluate various candidate fuel systems, they were first screened thermodynamically with respect to their energy content and cooling capacities. To evaluate the vehicle performance with different fuel systems, a simple computer model is developed to compute the vehicle parameters such as the vehicle volume, dry mass, effective specific impulse, and payload capacity. The results indicate that if the payload capacity (or the gross lift-off mass) is the most important criterion, only slush hydrogen and liquid hydrogen - liquid methane gel shows better performance than the liquid hydrogen vehicle. If all the advantages of a smaller vehicle are considered and a more accurate mass analysis can be performed, other systems using endothermic fuels such as cyclohexane, and some boranes may prove to be worthy of further consideration.

Akyurtlu, Ates↗

Modulating Concentration Of Hydrazine Vapor To Aid Detection

Three techniques, flow modulation, filament modulation, and reactive-filter modulation developed to obtain selective response to hydrazine or to methyl hydrazines from photoionization detector. Implemented in portable selective hydrazine detectors, useful where continuous or rapid, repetitive quantitative measurements of concentrations of vapors of these toxic substances required. Measure concentration of gaseous hydrazines in presence of other gases like cyclohexane, chlorofluorocarbons, and ammonia. Produce modulated signal, amplitude and phase indicating amount of hydrazine, monomethyl hydrazine, or 1,1-dimethyl hydrazine present in mixture. Used with such other detectors as electrochemical cells.

Stetter, Joseph R.↗

Comparison of hecter fuel with export aviation gasoline

Among the fuels which will operate at compression ratios up to at least 8.0 without preignition or "pinking" is hecter fuel, whence a careful determination of its performance is of importance. For the test data presented in this report the hecter fuel used was a mixture of 30 per cent benzol and 70 per cent cyclohexane, having a low freezing point, and distilling from first drop to 90 per cent at nearly a constant temperature, about 20 degrees c. below the average distillation temperature ("mean volatility") of the x gasoline (export grade). The results of these experiments show that the power developed by hecter fuel is the same as that developed by export aviation gasoline at about 1,800 r.p.m. at all altitudes. At lower speeds differences in the power developed by the fuels become evident. Comparisons at ground level were omitted to avoid any possibility of damaging the engine by operating with open throttle on gasoline at so high a compression. The fuel consumption per unit power based on weight, not volume, averaged more than 10 per cent greater with hecter than with x gasoline. The thermal efficiency of the engine when using hecter is less than when using gasoline, particularly at higher speeds. A generalization of the difference for all altitudes and speeds being 8 per cent. A general deduction from these facts is that more hecter is exhausted unburnt. Hecter can withstand high compression pressures and temperature without preignition. (author)

Dickinson, H C↗

Marangoni-Benard Convection in a Evaporating Liquid Thin Layer

Marangoni-Benard convection in evaporating liquid thin layers has been investigated through flow visualization and temperature profile measurement. Twelve liquids, namely ethyl alcohol, methanol, chloroform, acetone, cyclohexane, benzine, methylene chloride, carbon tetrachloride, ethyl acetate, n-pentane, silicone oil (0.65 cSt.), and freon-113, were tested and convection patterns in thin layers of these samples were observed. Comparison among these tested samples shows that some liquids are sensitive to surface contamination from aluminum powder but some are not. The latter is excellent to be used for the investigation of surface-tension driven convection through visualization using the tracer. Two sample liquids, alcohol and freon-113 were particularly selected for systematic study. It was found that the wavelength of Benard cells would not change with thickness of the layer when it evaporates at room temperature. Special attention was focused on cases in which a liquid layer was cooled from below, and some interesting results were obtained. Convection patterns were recorded during the evaporation process and the patterns at certain time frame were compared. Benard cells were observed in thin layers with a nonlinear temperature profile and even with a zero or positive temperature gradient. Wavelength of the cells was found to increase as the evaporation progressed.