Search NASA⌕ Search

SEARCH · Search NASA

Results for “data acquisition circuits”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Radiation-Hardened Circuitry Using Mask-Programmable Analog Arrays. Final Report

As the recent accident at Fukushima Daiichi so vividly demonstrated, telerobotic technologies capable of withstanding high radiation environments need to be readily available to enable operations, repair, and recovery under severe accident scenarios where human entry is extremely dangerous or not possible. Telerobotic technologies that enable remote operation in high dose rate environments have undergone revolutionary improvement over the past few decades. However, much of this technology cannot be employed in nuclear power environments due the radiation sensitivity of the electronics and the organic insulator materials currently in use. This is the final report of the activities involving the NEET 2 project Radiation Hardened Circuitry Using Mask-Programmable Analog Arrays. We present a detailed functional block diagram of the proposed data acquisition system, the thought process leading to technical decisions, the implemented system, and the tested results from the systems. This system will be capable of monitoring at least three parameters of importance to nuclear reactor monitoring: temperature, radiation level, and pressure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Architecture of a Silicon Strip Beam Position Monitor

A collaboration between Fermilab and the Institute for High Energy Physics (IHEP), Beijing, has developed a beam position monitor for the IHEP test beam facility. This telescope is based on 5 stations of silicon strip detectors having a pitch of 60 microns. The total active area of each layer of the detector is about 12 x 10 cm{sup 2}. Readout of the strips is provided through the use of VA1 ASICs mounted on custom hybrid printed circuit boards and interfaced to Adapter Cards via copper-over-kapton flexible circuits. The Adapter Cards amplify and level-shift the signal for input to the Fermilab CAPTAN data acquisition nodes for data readout and channel configuration. These nodes deliver readout and temperature data from triggered events to an analysis computer over gigabit Ethernet links.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Versatile Planetary Radio Science Microreceiver

We have developed a low-power. programmable radio "microreceiver" that combines the functionality of two science instruments: a Relative Ionospheric Opacity Meter (riometer) and a swept-frequency, VTF/HF radio spectrometer. The radio receiver, calibration noise source, data acquisition and processing, and command and control functions are all contained on a single circuit board. This design is suitable for miniaturizing as a complete flight instrument. Several of the subsystems were implemented in a field-programmable gate array (FPGA), including the receiver detector, the control logic, and the data acquisition and processing blocks. Considerable efforts were made to reduce the power consumption of the instrument, and eliminate or minimize RF noise and spurious emissions generated by the receiver's digital circuitry. A prototype instrument was deployed at McMurdo Station, Antarctica, and operated in parallel with a traditional riometer instrument for approximately three weeks. The attached paper (accepted for publication by Radio Science) describes in detail the microreceiver theory of operation, performance specifications and test results.

Fry, Craig D.↗

Predicting Trends in VOC Through Rapid, Multimodal Characterization of State-of-the-Art p-i-n Perovskite Devices

Perovskite photovoltaic technologies are approaching commercial deployment, yet single junction and tandem architectures both still have significant room to improve power conversion efficiency and stability. The ability to perform rapid screening of material quality after altering processing conditions is critical to accelerating the optimization and commercialization of perovskite-based technologies. Currently, researchers utilize a wide range of stand-alone metrology tools to isolate sources of power loss throughout a device stack, which can be slow and labor intensive. Here, we demonstrate the use of a multimodal metrology approach to rapidly determine the maximum achievable and predicted open circuit voltages of >100 perovskite devices during fabrication. Acquisition of these different data is facilitated by combining them into a single integrated measurement platform. We show that these data and automated analysis can be used to rapidly understand and ultimately predict quantitative trends in open circuit voltages of state-of-the-art device architectures. The data and automated analysis workflow presented provides a reliable approach to quickly identify absorber and charge transport layer combinations that can lead to improved open circuit voltages.

14 SOLAR ENERGY↗

Program Calibrates Strain Gauges

Program dramatically reduces personnel and time requirements for acceptance tests of hardware. Data-acquisition system reads output from Wheatstone full-bridge strain-gauge circuit and calculates strain by use of shunt calibration technique. Program nearly instantaneously tabulates and plots strain data against load-cell outputs. Modified to acquire strain data for other specimens wherever full-bridge strain-gauge circuits used. Written in HP BASIC.

Okazaki, Gary D.↗

Design of the SLAC RCE Platform: A General Purpose ATCA Based Data Acquisition System

The SLAC RCE platform is a general purpose clustered data acquisition system implemented on a custom ATCA compliant blade, called the Cluster On Board (COB). The core of the system is the Reconfigurable Cluster Element (RCE), which is a system-on-chip design based upon the Xilinx Zynq family of FPGAs, mounted on custom COB daughter-boards. The Zynq architecture couples a dual core ARM Cortex A9 based processor with a high performance 28nm FPGA. The RCE has 12 external general purpose bi-directional high speed links, each supporting serial rates of up to 12Gbps. 8 RCE nodes are included on a COB, each with a 10Gbps connection to an on-board 24-port Ethernet switch integrated circuit. The COB is designed to be used with a standard full-mesh ATCA backplane allowing multiple RCE nodes to be tightly interconnected with minimal interconnect latency. Multiple shelves can be clustered using the front panel 10-gbps connections. The COB also supports local and inter-blade timing and trigger distribution. An experiment specific Rear Transition Module adapts the 96 high speed serial links to specific experiments and allows an experiment-specific timing and busy feedback connection. This coupling of processors with a high performance FPGA fabric in a low latency, multiple node cluster allows high speed data processing that can be easily adapted to any physics experiment. RTEMS and Linux are both ported to the module. The RCE has been used or is the baseline for several current and proposed experiments (LCLS, HPS, LSST, ATLAS-CSC, LBNE, DarkSide, ILC-SiD, etc).

43 PARTICLE ACCELERATORS↗

Linear Array Photodiode and Data Acquisition System Development for Multi-Point Line FLDI Measurements

The continuous development and advancement of multi-point line focused laser differential interferometry (FLDI) instruments requires larger numbers of acquisition channels to make more finely spatially resolved measurements of high-frequency flow fluctuations. No current off-the-shelf system exists for these line FLDI measurements, and so a single unified system consisting of a linear array photodiode, required electronics, and a data acquisition system has been developed to enhance the measurement resolution, both spatially and temporally. A printed circuit board was developed on which the linear array photodiode is mounted for inclusion into an existing FLDI system, and amplifier breakout boards incorporate electronics to condition the signal for the data acquisition system while retaining the necessary high frequency response. The data acquisition system uses a National Instruments chassis and multiple oscilloscope modules, with a specially-designed LabVIEW user interface for laboratory and wind tunnel setup, calibration, and testing. Details regarding the development of the linear array photodiode system and the data acquisition system are provided, and systematic testing of all components is presented, culminating in a test of the system integrated into an existing line FLDI system for measurements of a turbulent jet.

Joshua M Weisberger↗

Command and data handling of science signals on Spacelab

The Orbiter Avionics and the Spacelab Command and Data Management System (CDMS) combine to provide a relatively complete command, control, and data handling service to the instrument complement during a Shuttle Sortie Mission. The Spacelab CDMS services the instruments and the Orbiter in turn services the Spacelab. The CDMS computer system includes three computers, two I/O units, a mass memory, and a variable number of remote acquisition units. Attention is given to the CDMS high rate multiplexer, CDMS tape recorders, closed circuit television for the visual monitoring of payload bay and cabin area activities, methods of science data acquisition, questions of transmission and recording, CDMS experiment computer usage, and experiment electronics.

Mccain, H. G.↗

NASA Tech Briefs, October 1995

A special focus in this issue is Data acquisition and analysis. Topics covered include : Electronic Components and Circuits; Electronic Systems; Physical Sciences; Materials; Life Sciences; Mechanics; Machinery; Fabrication Technology; and Mathematics and Information Sciences. Also included in this issue are Laser Tech Briefs and Industry Focus: Motion Control/ Positioning Equipment

Source record↗

A Brief Technical History of the Large-Area Picosecond Photodetector (LAPPD) Collaboration

The Large Area Picosecond PhotoDetector (LAPPD) Collaboration was formed in 2009 to develop large-area photodetectors capable of time resolutions measured in pico-seconds, with accompanying sub-millimeter spatial resolution. During the next three and one-half years the Collaboration developed the LAPPD design of 20 x 20 cm modules with gains greater than $10^7$ and non-uniformity less than $15\%$, time resolution less than 50 psec for single photons and spatial resolution of 700~microns in both lateral dimensions. We describe the R\&D performed to develop large-area micro-channel plate glass substrates, resistive and secondary-emitting coatings, large-area bialkali photocathodes, and RF-capable hermetic packaging. In addition, the Collaboration developed the necessary electronics for large systems capable of precise timing, built up from a custom low-power 15-GigaSample/sec waveform sampling 6-channel integrated circuit and supported by a two-level modular data acquisition system based on Field-Programmable Gate Arrays for local control, data-sparcification, and triggering. We discuss the formation, organization, and technical successes and short-comings of the Collaboration. The Collaboration ended in December 2012 with a transition from R\&D to commercialization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Demodulator electronics for laser vibrometry

One of the most important parts of a fiber-laser vibrometer is demodulation electronic section. The distortion, nonlinearity, offset and added noise of measured signal come from electronic circuits and they have direct influence on finale measuring results. Two main parameters of an investigated vibrating object: velocity V(t) and displacement s(t), influence of detected beat signals. They are: the Doppler frequency deviation f(t) and phase shift {phi}(t), respectively. Because of wide range of deviations it is difficult to use just one demodulator. That is the reason why we use three different types of demodulators. The first one is the IQ demodulator, which is the most sensitive one and its output is proportional to the displacement. Each IQ channel is sampled simultaneously by an analog to digital converter (ADC) integrated in a digital signal processor (DSP). The output signals from the two FM demodulators are proportional to the frequency deviation of heterodyne signals. They are sensitive directly to the velocity of the object. The main disadvantage of scattered light interferometry system is a ''speckle effect'', appearing in relatively large amplitude fluctuation of a heterodyne signal. To minimize ''speckle effect'' influence on quality of beat signals we applied the automatic gain control (AGC) system. Data acquisition, further signal processing (e.g. vibration frequency spectra) and presentation of results is realized by PC via USB interface.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Chopper-stabilized phase detector

Phase-detector circuit for binary-tracking loops and other binary-data acquisition systems minimizes effects of drift, gain imbalance, and voltage offset in detector circuitry. Input signal passes simultaneously through two channels where it is mixed with early and late codes that are alternately switched between channels. Code switching is synchronized with polarity switching of detector output of each channel so that each channel uses each detector for half time. Net result is that dc offset errors are canceled, and effect of gain imbalance is simply change in sensitivity.

Hopkins, P. M.↗

NASA Tech Briefs, January 2000

Topics include: Data Acquisition; Computer-Aided Design and Engineering; Electronic Components and Circuits; Electronic Systems; Bio-Medical; Physical Sciences; Materials; Computer Programs; Mechanics; Machinery/Automation; Information Sciences; Books and reports.

Source record↗

NASA Tech Briefs, July 2000

Topics covered include: Data Acquisition; Computer-Aided Design and Engineering; Electronic Components and Circuits; Electronic Systems; Test and Measurement; Physical Sciences; Materials; Computer Programs; Mechanics; Machinery/Automation; Manufacturing/Fabrication; Mathematics and Information Sciences; Life Sciences; Books and Reports.

Source record↗

Detector Control and Data Acquisition for the Wide-Field Infrared Survey Telescope (WFIRST) with a Custom ASIC

The Wide-Field Infrared Survey Telescope (WFIRST) will have the largest near-IR focal plane ever flown by NASA, a total of 18 4K x 4K devices. The project has adopted a system-level approach to detector control and data acquisition where 1) control and processing intelligence is pushed into components closer to the detector to maximize signal integrity, 2) functions are performed at the highest allowable temperatures, and 3) the electronics are designed to ensure that the intrinsic detector noise is the limiting factor for system performance. For WFIRST, the detector arrays operate at 90 to 100 K, the detector control and data acquisition functions are performed by a custom ASIC at 150 to 180 K, and the main data processing electronics are at the ambient temperature of the spacecraft, notionally approx.300 K. The new ASIC is the main interface between the cryogenic detectors and the warm instrument electronics. Its single-chip design provides basic clocking for most types of hybrid detectors with CMOS ROICs. It includes a flexible but simple-to-program sequencer, with the option of microprocessor control for more elaborate readout schemes that may be data-dependent. All analog biases, digital clocks, and analog-to-digital conversion functions are incorporated and are connected to the nearby detectors with a short cable that can provide thermal isolation. The interface to the warm electronics is simple and robust through multiple LVDS channels. It also includes features that support parallel operation of multiple ASICs to control detectors that may have more capability or requirements than can be supported by a single chip.

data acquisition↗

FPGA-based prototype of portable environmental radiation monitor

This new portable radiological environmental monitor consists of 2 main components, Gamma ionization chamber and a FPGA-based electronic enclosure linked to convivial software for treatment and analyzing. The HPIC ion chamber is the heart of this radiation measurement system and is running in range from 0 to 100 mR/h, so that the sensitivity at the output is 20 mV/μR/h, with a nearly flat energy response from 0,07 to 10 MEV. This paper presents a contribution for developing a new nuclear measurement data acquisition system based on Cyclone III FPGA Starter Kit ALTERA, and a user-friendly software to run real-time control and data processing. It was developed to substitute the older radiation monitor RSS-112 PIC installed in CNESTEN's Laboratory in order to improve some of its functionalities related to acquisition time and data memory capacity. As for the associated acquisition software, it was conceived under the virtual LabView platform from National Instrument, and offers a variety of system setup for radiation environmental monitoring. It gives choice to display both the statistical data and the dose rate. Statistical data shows a summary of current data, current time/date and dose integrator values, and the dose rate displays the current dose rate in large numbers for viewing from a distance as well as the date and time. The prototype version of this new instrument and its data processing software has been successfully tested and validated for viewing and monitoring the environmental radiation of Moroccan nuclear center. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time-tagging data acquisition system for testing superconducting electronics based on an RFSoC and custom analog frontend

Novel electronic devices can often be operated in a plethoraof ways, which makes testing circuits comprised of them difficult.Often, no single tool can simultaneously analyze the operatingmargins, maximum speed, and failure modes of a circuit, particularlywhen the intended behavior of subcomponents of the circuit is notstandardized. This work demonstrates a cost-effective time-domaindata acquisition system for electronic circuits that enables moreintricate verification techniques than are practical withconventional experimental setups. We use high-speeddigital-to-analog converters and real-timemulti-gigasample-per-second waveform processing to push experimentalcircuits beyond their maximum operating speed. Our customtime-tagging data capture firmware reduces memory requirements andcan be used to determine when errors occur. The firmware iscombined with a thermal-noise-limited analog frontend with50 dB of dynamic range. Compared to currentlyavailable commercial test equipment that is seven times moreexpensive, this data acquisition system was able to operate asuperconducting shift register at a nearly three-times-higher clockfrequency (200 MHz vs. 80 MHz).

Foster, Reed A. [MIT] (ORCID:0000000231002127)↗

Attentional Ptycho-Tomography (APT) for three-dimensional nanoscale X-ray imaging with minimal data acquisition and computation time

Abstract Noninvasive X-ray imaging of nanoscale three-dimensional objects, such as integrated circuits (ICs), generally requires two types of scanning: ptychographic, which is translational and returns estimates of the complex electromagnetic field through the IC; combined with a tomographic scan, which collects these complex field projections from multiple angles. Here, we present Attentional Ptycho-Tomography (APT), an approach to drastically reduce the amount of angular scanning, and thus the total acquisition time. APT is machine learning-based, utilizing axial self-Attention for Ptycho-Tomographic reconstruction. APT is trained to obtain accurate reconstructions of the ICs, despite the incompleteness of the measurements. The training process includes regularizing priors in the form of typical patterns found in IC interiors, and the physics of X-ray propagation through the IC. We show that APT with ×12 reduced angles achieves fidelity comparable to the gold standard Simultaneous Algebraic Reconstruction Technique (SART) with the original set of angles. When using the same set of reduced angles, then APT also outperforms Filtered Back Projection (FBP), Simultaneous Iterative Reconstruction Technique (SIRT) and SART. The time needed to compute the reconstruction is also reduced, because the trained neural network is a forward operation, unlike the iterative nature of these alternatives. Our experiments show that, without loss in quality, for a 4.48 × 93.2 × 3.92 µm 3 IC (≃6 × 10 8 voxels), APT reduces the total data acquisition and computation time from 67.96 h to 38 min. We expect our physics-assisted and attention-utilizing machine learning framework to be applicable to other branches of nanoscale imaging, including materials science and biological imaging.

47 OTHER INSTRUMENTATION↗