Search NASA⌕ Search

SEARCH · Search NASA

Results for “data acquisition systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Time-tagging data acquisition system for testing superconducting electronics based on an RFSoC and custom analog frontend

Novel electronic devices can often be operated in a plethoraof ways, which makes testing circuits comprised of them difficult.Often, no single tool can simultaneously analyze the operatingmargins, maximum speed, and failure modes of a circuit, particularlywhen the intended behavior of subcomponents of the circuit is notstandardized. This work demonstrates a cost-effective time-domaindata acquisition system for electronic circuits that enables moreintricate verification techniques than are practical withconventional experimental setups. We use high-speeddigital-to-analog converters and real-timemulti-gigasample-per-second waveform processing to push experimentalcircuits beyond their maximum operating speed. Our customtime-tagging data capture firmware reduces memory requirements andcan be used to determine when errors occur. The firmware iscombined with a thermal-noise-limited analog frontend with50 dB of dynamic range. Compared to currentlyavailable commercial test equipment that is seven times moreexpensive, this data acquisition system was able to operate asuperconducting shift register at a nearly three-times-higher clockfrequency (200 MHz vs. 80 MHz).

Foster, Reed A. [MIT] (ORCID:0000000231002127)↗

Constellation: The autonomous control and data acquisition system for dynamic experimental setups

The operation of instruments and detectors in laboratory or beamline environments presents a complex challenge, requiring stable operation of multiple concurrent devices, often controlled by separate hardware and software solutions. These environments frequently undergo modifications, such as the inclusion of different auxiliary devices depending on the experiment or facility, adding further complexity. The successful management of such dynamic configurations demands a flexible and robust system capable of controlling data acquisition, monitoring experimental setups, enabling seamless reconfiguration, and integrating new devices with limited effort. This paper presents Constellation, a flexible and network-distributed control and data acquisition software framework tailored to laboratory and beamline environments, that addresses the limitations of existing solutions. The framework is designed with a focus on extensibility, providing a streamlined interface for instrument integration. It supports efficient system setup via network discovery mechanisms, promotes stability through autonomous operational features, and provides comprehensive documentation and supporting tools for operators and application developers such as controllers and logging interfaces. At the core of the architectural design is the autonomy of the individual components, called satellites, which can make independent decisions about their operation and communicate these decisions to other components. This paper introduces the design principles and framework architecture of Constellation, presents the available graphical user interfaces, shares insights from initial successful deployments, and provides an outlook on future developments and applications.

Autonomy↗

Multi-Sensor Data Acquisition System for Process Monitoring

Idaho National Laboratory is building a new nuclear fuel cycle test bed. This fuel cycle test bed named “Beartooth” will give researchers the opportunity to study the nuclear fuel cycle process. The process operations include the use of centrifugal contactors and process flow for the purification of special nuclear material recovery in used fuel. This new research facility has the need to use non-traditional measurement sensors to determine the state-of-health of the solvent extraction process. These non-traditional sensors can also enhance nuclear nonproliferation supervision and other activities. The non-traditional sensors include accelerometers, acoustic, current, flow, colorimetric, temperature, pH and conductivity. The challenge behind deploying all these sensors, is the need for fast and reliable data collection. The data acquisition system (DAQ) needs to be capable of recording up to 12 accelerometers and/or acoustic microphones simultaneously at rates up to 12.8 kSamples/second/channel. This requires the need for a strong architecture and data collection solution. This summary identifies the system architecture, DAQ, and sensors needed to support non-traditional measurements in a solvent extraction process.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Data Acquisition System Selection and Calibration of Resistive Moisture Content Measurements for Large-Scale Field Studies in Cold Climate Residential Building Envelope Performance

The residential building stock built before the energy codes were enforced has several significant inefficiency problems in terms of insulation and air leakage. To decrease these inefficiencies, building retrofits are necessary. However, if the envelope is not appropriately designed, excessive accumulation of moisture content and thus mold formation and decay inside the envelope layers can be a vital problem. This risk becomes higher, especially in extreme climate conditions such as cold winters and hot and humid summers as in some northern regions of the U.S. Field studies are essential to test the long-term hygrothermal performance of building envelopes. Although in-situ temperature, RH, and heat flux measurements are straightforward, moisture content measurements are cumbersome. Mainly, because of the heterogeneous nature of the wood materials, deviations and nonuniformities within the materials are unavoidable. Resistance measurements are one of the oldest methods used to measure the moisture content of wood and other building materials. In large-scale studies, it is commonly preferred to use multi-purpose data acquisition systems (DAQ) and custom-made or prefabricated moisture pins to measure the electrical resistance (and thus moisture content) of critical building materials. These multi-purpose DAQ systems generally provide lower costs and offer more flexibility. However, these systems require calibration and fine-tuning to achieve accurate moisture content measurements. A large-scale, two-year-long field study was conducted in northern Minnesota to monitor the hygrothermal performance of residential retrofit wall systems in cold climates. Two base case walls and sixteen different wall treatments were tested. Moisture contents were measured at various layers in each wall treatment using 85 sets of moisture pins. This paper focuses on the overall approach, fabrication, and calibration methodology for the combination of custom-made moisture pins and a multi-purpose DAQ. The aim is to directly use the low-excitation multi-purpose DAQ without any extra voltage regulator. A half-bridge circuit is used to measure wood resistance with 4V excitation voltage and 100 kΩ and 500 kΩ reference resistors. The system is calibrated for four different materials: Douglas fir, lodgepole pine, western red cedar, and oriented strand board (OSB). Calibration experiments were done under controlled conditions in 50% and 65% RH test chambers. Resistance-based moisture content calibration curves are obtained for each species. Results show that higher reference resistors provided better calibration curves for lower excitation voltages.

Desjarlais, Andre Omer↗

A data acquisition system for HV-CMOS sensor research and development in the upgrade of ATLAS experiment

In the High Luminosity LHC (HL-LHC) upgrade of ATLAS experiment in 2026, the new inner tracker detector will be installed. As a promising candidate for the outer layer of the inner tracker detector, the High Voltage CMOS (HV-CMOS) pixel sensors are being investigated by the ATLAS collaboration. A Front-End LInk eXchange (FELIX) based Data Acquisition (DAQ) system is developed for the R&D of the HV-CMOS sensors. A FELIX card with PCIe interface in the back-end is used to control, monitor, calibrate and read out the front-end electronics. In the front-end, a Xilinx evaluation board ZC706 works as the interface between the back- end and custom boards with HV-CMOS sensors and the readout ASIC. In conclusion, the DAQ system was successfully deployed for the testbeam experiment at CERN. Design of the DAQ system, the tuning of sensors and testbeam results will be described in details.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The JSNS 2 data acquisition system

The JSNS 2 (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) experiment aims to search for neutrino oscillations over a 24 m short baseline at J-PARC. The JSNS 2 inner detector is filled with 17 tons of gadolinium(Gd)-loaded liquid scintillator (LS) with an additional 31 tons of unloaded LS in the intermediate γ-catcher and an optically separated outer veto volumes. A total of 120 10-inch photomultiplier tubes observe the scintillating optical photons and each analog waveform is stored with flash analog-to-digital converters. Here, we present details of the data acquisition, processing, and data quality monitoring system. We also present two different trigger logics which are developed for the beam and self-trigger.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Integration of the Trigger and Data Acquisition Systems in ATLAS

During 2006 and the first half of 2007, the installation, integration and commissioning of trigger and data acquisition (TDAQ) equipment in the ATLAS experimental area have progressed. There have been a series of technical runs using the final components of the system already installed in the experimental area. Various tests have been run including ones where level 1 preselected simulated proton-proton events have been processed in a loop mode through the trigger and dataflow chains. The system included the readout buffers containing the events, event building, level 2 and event filter trigger algorithms. The scalability of the system with respect to the number of event building nodes used has been studied and quantities critical for the final system, such as trigger rates and event processing times, have been measured using different trigger algorithms as well as different TDAQ components. This paper presents the TDAQ architecture, the current status of the installation and commissioning and highlights the main test results that validate the system.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The IceCube data acquisition system: Signal capture, digitization,and timestamping

IceCube is a km-scale neutrino observatory under construction at the South Pole with sensors both in the deep ice (InIce) and on the surface (IceTop). The sensors, called Digital Optical Modules (DOMs), detect, digitize and timestamp the signals from optical Cherenkov-radiation photons. The DOM Main Board (MB) data acquisition subsystem is connected to the central DAQ in the IceCube Laboratory (ICL) by a single twisted copper wire-pair and transmits packetized data on demand. Time calibration ismaintained throughout the array by regular transmission to the DOMs of precisely timed analog signals, synchronized to a central GPS-disciplined clock. The design goals and consequent features, functional capabilities, and initial performance of the DOM MB, and the operation of a combined array of DOMs as a system, are described here. Experience with the first InIce strings and the IceTop stations indicates that the system design and performance goals have been achieved.

79 ASTRONOMY AND ASTROPHYSICS↗

Data Acquisition System for RF Cavity Hadron Monitor

As Fermilab pursues intensity frontier physics, the conventional detectors are not up to the challenge of higher radiation exposure. The detectors in the NuMI beamline rely on knowing the beam composition in order to infer properties of the resultant neutrino beam. Anovel gas-filled RF cavity beam detector is proposed that will be simple and radiation robust in high-radiation environments. Charged particles passing through the cavity produce ionized plasma, which changes the permittivity of the gas and modulate the stored RF field in the cavity. The recent preliminary beam result demonstrates the proof of principle of the beam detector. In an effort to acquire a large amount of data for various cavity parameters, an automatic data acquisition(DAQ)system is designed in LabVIEW. The DAQ system utilizes a Real-Time Power meter from Boonton to acquire RF power data from the cavity.

43 PARTICLE ACCELERATORS↗

Data Acquisition System for RF Cavity Hadron Monitor

As Fermilab pursues intensity frontier physics, the conventional detectors are not up to the challenge of higher radiation exposure. The detectors in the NuMI beamline rely on knowing the angular distribution of the secondary hadrons in order to infer properties of the resultant neutrino beam. A novel gas-filled RF cavity beam detector is proposed that will be simple and radiation robust in high-radiation environments. Charged particles passing through the cavity produce ionized plasma, which changes the permittivity of the gas and modulate the stored RF field in the cavity. The preliminary beam test of an RF cavity demonstrates the proof of principle of the beam detector. In an effort to acquire a large amount of data for various cavity parameters, an automatic data acquisition (DAQ) system is designed in LabVIEW. The DAQ system utilizes a Real-Time Power meter from Boonton to acquire RF power data from the cavity.

43 PARTICLE ACCELERATORS↗

Development and test of a mini-Data Acquisition system for the High-Luminosity LHC upgrade of the ATLAS Monitored Drift Tube detector

New front-end electronics including ASICs and FPGA boards are under development for the ATLAS Monitored Drift Tube (MDT) detector to handle the large data rates and harsh environment expected at high-luminosity LHC runs. A mobile Data Acquisition (miniDAQ) system is designed to perform integration tests of these front-end electronics. In addition, it will be used for surface commissioning of 96 small-radius MDT (sMDT) chambers and for integration and commissioning of new front-end electronics on the present ATLAS MDT chambers. Details of the miniDAQ hardware and firmware are described in this article. Here, the miniDAQ system is also used to read out new front-end electronics on an sMDT prototype chamber using cosmic muons and results obtained are shown.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The SciBooNE Data Acquisition System

SciBooNE started in June 2007 primarily to study neutrino and anti-neutrino interactions in the energy region below 1 GeV. The SciBooNE detector is located in Booster Neutrino Beamline at Fermi National Accelerator Laboratory. The SciBooNE data aquisition system consists of the readout software and an event builder, which collects data from each detector component (SciBar detector, an electromagnetic calorimeter, Muon Range Detector and GPS). The typical DAQ readout time per trigger is 20 ms, which is fast enough to take every beam spill. The system is also very stable and the probability of missing a beam spill due to the readout time is less than 0.002 %.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Upgrade of the CAESium-iodide scintillator ARray (CAESAR) electronics and data acquisition system for optimized performance at FRIB

Here, we report on the upgrade of the electronics and data acquisition (DAQ) of the high-efficiency CAESium-iodide scintillator ARray (CAESAR) at the Facility for Rare Isotope Beams (FRIB). With the on-going capability ramp-up of FRIB, CAESAR is expected to continue to be an in-demand -ray spectrometer owing to its high detection efficiency, compactness, and modularity, enabling easy integration with additional detection and DAQ systems. Within this context, the CAESAR electronics and DAQ were upgraded to remove obsolete modules, enhance the ease of integration with external instruments, and optimize the DAQ live time. We present the comprehensive results from offline (γ-ray sources) and online (in-beam experiment) commissioning, characterizing the performance of CAESAR’s new electronics and DAQ.

CsI(Na) scintillator array↗

Calibration of a compact ASIC-based data acquisition system for neutron/$γ$ discrimination and spectroscopy with organic scintillators

Segmented neutron detectors that use silicon photomultipliers (SiPMs) are receiving significant attention in nuclear security applications. Some of these detectors employ hundreds of channels and would therefore benefit from the use of high-channel-density and low-cost-per-channel data acquisition (DAQ) systems. Candidate DAQ systems that meet these requirements exist, but few perform full waveform digitization, which permits neutron and gamma-ray interaction discrimination via pulse shape. In this work, we study the performance of the TOFPET2 (PETsys Electronics), an ASIC-based DAQ designed for positron emission tomography, which has been adapted to provide sensitivity to pulse shape by the use of variable-period charge integration. We use a light-emitting diode to calibrate a combination of an ON Semiconductor (SensL) 60035-64P J-Series SiPM and TOPFET2 DAQ and evaluate the linearity of their response and dynamic range. Here, the calibration curve was obtained by comparing the DAQ response to that measured with a photodiode interfaced with a traditional waveform digitizer. This calibration process was used for rudimentary spectroscopy of various neutron and sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast integrator based data acquisition system for the SST-1 Thomson scattering system

An operational transconductance amplifier based fast charge-integrating module (FCIM) is designed and developed for an easy acquisition of fast Thomson scattered and background signal. FCIM based data acquisition technique can be used for the measurement of charge pulses of <20 ns duration. The response of the module is tested using a standard pulsed charge-generating module. The measuring charge range of the module depends on the integrating capacitor. Comparison of the performance of FCIM to commercially available module shows that it has better dynamic range with higher sensitivity and less measurement error. The module is quite cost effective and has many new features.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A faster and more reliable data acquisition system for the full performance of the SciCRT

The SciBar Cosmic Ray Telescope (SciCRT) is a massive scintillator tracker to observe cosmic rays at a very high-altitude environment in Mexico. The fully active tracker is based on the Scintillator Bar (SciBar) detector developed as a near detector for the KEK-to-Kamioka long-baseline neutrino oscillation experiment (K2K) in Japan. Since the data acquisition (DAQ) system was developed for the accelerator experiment, we determined to develop a new robust DAQ system to optimize it to our cosmic-ray experiment needs at the top of Mt. Sierra Negra (4600 m). One of our special requirements is to achieve a 10 times faster readout rate. We started to develop a new fast readout back-end board (BEB) based on 100 Mbps SiTCP, a hardware network processor developed for DAQ systems for high energy physics experiments. Then we developed the new BEB which has a potential of 20 times faster than the current one in the case of observing neutrons. Lastly, we installed the new DAQ system including the new BEBs to a part of the SciCRT in July 2015. The system has been operating since then. In this article, we describe the development, the basic performance of the new BEB, the status after the installation in the SciCRT, and the future performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A scaler-based data acquisition system for measuring parity-violating asymmetry in deep inelastic scattering

An experiment that measured the parity violating asymmetries in deep inelastic scattering was completed at the Thomas Jefferson National Accelerator Facility in experimental Hall A. From these asymmetries, a combination of the quark weak axial charge could be extracted with a factor of five improvement in precision over world data. To achieve this, asymmetries at the 10^-4 level needed to be measured at event rates up to 500 kHz and the high pion background typical to deep inelastic scattering experiments needed to be rejected efficiently. A specialized data acquisition (DAQ) system with intrinsic particle identification (PID) was successfully developed and used: The pion contamination in the electron samples was controlled at the order of 2 × 10^-4 or below with an electron efficiency of higher than 91% throughout the production period of the experiment, the systematic uncertainty in the measured asymmetry due to DAQ deadtime was below 0.2%, and the statistical quality of the asymmetry measurement agreed with the Gaussian distribution to over five orders of magnitudes. The DAQ system is presented here with an emphasis on its design scheme, the achieved PID performance, deadtime effect and the capability of measuring small asymmetries.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Snowmass Topical Group Summary Report: IF04 -- Trigger and Data Acquisition Systems

A trend for future high energy physics experiments is an increase in the data bandwidth produced from the detectors. Datasets of the Petabyte scale have already become the norm, and the requirements of future experiments -- greater in size, exposure, and complexity -- will further push the limits of data acquisition technologies to data rates of exabytes per seconds. The challenge for these future data-intensive physics facilities lies in the reduction of the flow of data through a combination of sophisticated event selection in the form of high-performance triggers and improved data representation through compression and calculation of high-level quantities. These tasks must be performed with low-latency (i.e. in real-time) and often in extreme environments including high radiation, high magnetic fields, and cryogenic temperatures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗