Search NASA⌕ Search

SEARCH · Search NASA

Results for “data filtration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Tank 9H Salt Solution Supernatant Characterization in Support of Potential Operating Strategies of Tank 9H Supernatant Through the Tank Closure Cesium Removal System

Savannah River Remediation (SRR) recently initiated an ion exchange process to remove radioactive cesium from dissolved salt solution in Tank 10H, known as Tank Closure Cesium Removal (TCCR). As part of that ongoing campaign, the salt in Tank 9H will be dissolved and transferred to Tank 10H for processing through the TCCR system, and SRR requested the characterization of the dissolved salt solution in Tank 9H prior to the transfer to Tank 10H. On July 18, 2019, Savannah River Remediation Engineering (SRR-E) delivered two variable depth Tank 9H salt solution samples, identified as samples HTF-9-19-74 and HTF-9-19-75 (combined total sample volume of about 400 mL) to the Savannah River National Laboratory (SRNL) for characterization. These two Tank 9H variable depth samples (HTF-9-19-74 and HTF-9-19-75 taken at ~180” and 42”, respectively) were retrieved from Riser 7 after hydro-lancing activities were complete. Approximately 4200 gallons of water were added to the tank during this activity. This report presents the analytical characterization results for the Tank 9H salt solution variable depth samples HTF-9-19-74 and HTF-9-19-75 and contains mainly the filtrate analytical results for anions, elements, mass spectral data, total cesium characterization results and select radionuclide results, along with the X-ray diffraction characterization of the solid fractions from the liquid /solid separation of the variable depth salt solutions. Most of these analyses were performed in duplicate with the percent relative standard deviation (%RSD), a measure of the variability between each duplicate data set expressed as a percentage, used to estimate the analytical result quality for each analyte.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Application of OMI, SCIAMACHY and GOME-2 Satellite SO2 Retrievals for Detection of Large Emission Sources

Retrievals of sulfur dioxide (SO2) from space-based spectrometers are in a relatively early stage of development. Factors such as interference between ozone and SO2 in the retrieval algorithms often lead to errors in the retrieved values. Measurements from the Ozone Monitoring Instrument (OMI), Scanning Imaging Absorption Spectrometer for Atmospheric Chartography (SCIAMACHY), and Global Ozone Monitoring Experiment-2 (GOME-2) satellite sensors, averaged over a period of several years, were used to identify locations with elevated SO2 values and estimate their emission levels. About 30 such locations, detectable by all three sensors and linked to volcanic and anthropogenic sources, were found after applying low and high spatial frequency filtration designed to reduce noise and bias and to enhance weak signals to SO2 data from each instrument. Quantitatively, the mean amount of SO2 in the vicinity of the sources, estimated from the three instruments, is in general agreement. However, its better spatial resolution makes it possible for OMI to detect smaller sources and with additional detail as compared to the other two instruments. Over some regions of China, SCIAMACHY and GOME-2 data show mean SO2 values that are almost 1.5 times higher than those from OMI, but the suggested spatial filtration technique largely reconciles these differences.

SO2 retrievals↗

SU-E-P-15: Technique Factor Modulation and Reference Plane Air Kerma Rates in Response to Simulated Patient Thickness Variations for a Sample of Current Generation Fluoroscopes

Purpose: To evaluate and compare approaches to technique factor modulation and air kerma rates in response to simulated patient thickness variations for four state-of-the-art and one previous-generation interventional fluoroscopes. Methods: A polymethyl methacrylate (PMMA) phantom was used as a tissue surrogate for the purposes of determining fluoroscopic reference plane air kerma rates, kVp, mA, and spectral filtration over a wide range of simulated tissue thicknesses. Data were acquired for each fluoroscopic and acquisition dose curve within a default abdomen or body imaging protocol. Results: The data obtained indicated vendor- and model-specific variations in the approach to technique factor modulation and reference plane air kerma rates across a range of tissue thicknesses. Some vendors have made hardware advances increasing the radiation output capabilities of their fluoroscopes; this was evident in the acquisition air kerma rates. However, in the imaging protocol evaluated, all of the state-of-the-art systems had relatively low air kerma rates in the fluoroscopic low-dose imaging mode as compared to the previous-generation unit. Each of the newest-generation systems also employ copper filtration in the selected protocol in the acquisition mode of imaging; this is a substantial benefit, reducing the skin entrance dose to the patient in the highest dose-rate mode of fluoroscope operation. Conclusion: Understanding how fluoroscopic technique factors are modulated provides insight into the vendor-specific image acquisition approach and provides opportunities to optimize the imaging protocols for clinical practice. The enhanced radiation output capabilities of some of the fluoroscopes may, under specific conditions, may be beneficial; however, these higher output capabilities also have the potential to lead to unnecessarily high dose rates. Therefore, all parties involved in imaging, including the clinical team, medical physicists, and imaging vendors, must work together to ensure that adequate but not excessive radiation doses are used.

60 APPLIED LIFE SCIENCES↗

A beam hardening and dispersion correction for x-ray dark-field radiography

Purpose: X-ray dark-field imaging promises information on the small angle scattering properties even of large samples. However, the dark-field image is correlated with the object’s attenuation and phase-shift if a polychromatic x-ray spectrum is used. A method to remove part of these correlations is proposed. Methods: The experimental setup for image acquisition was modeled in a wave-field simulation to quantify the dark-field signals originating solely from a material’s attenuation and phase-shift. A calibration matrix was simulated for ICRU46 breast tissue. Using the simulated data, a dark-field image of a human mastectomy sample was corrected for the finger print of attenuation- and phase-image. Results: Comparing the simulated, attenuation-based dark-field values to a phantom measurement, a good agreement was found. Applying the proposed method to mammographic dark-field data, a reduction of the dark-field background and anatomical noise was achieved. The contrast between microcalcifications and their surrounding background was increased. Conclusions: The authors show that the influence of and dispersion can be quantified by simulation and, thus, measured image data can be corrected. The simulation allows to determine the corresponding dark-field artifacts for a wide range of setup parameters, like tube-voltage and filtration. The application of the proposed method to mammographic dark-field data shows an increase in contrast compared to the original image, which might simplify a further image-based diagnosis.

60 APPLIED LIFE SCIENCES↗

Fibreoptic distributed temperature sensor with spectral filtration by directional fibre couplers

We demonstrate a Raman-based all-fibre temperature sensor utilising a pulsed erbium fibre laser. The sensor is made of a standard single-mode telecom fibre, SMF-28, and includes a number of directional couplers as band-pass filters. The temperature profile along a 7-km fibreoptic line is measured with an accuracy of 2{sup o}C and a spatial resolution of 10 m. In data processing, we take into account the difference in attenuation between the spectral components of the backscatter signal. (optical fibres and fibreoptic sensors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Durability of Disposable N95 Mask Material When Exposed to Improvised Ozone Gas Disinfection

The principle finding of this report is that both commercial and a novel material used for N95 mask filters can endure many cycles of disinfection by ozone gas (20 ppm for 30 minutes) without detectable degradation or loss of filtration efficiency. N95 masks and surgical masks (hereafter referred to as masks) typically use a filtration material fabricated from meltblown polypropylene. To achieve maximum filtration efficiency while maintaining a reasonable pressure drop, these nonwoven fabrics are also electrostatically charged (corona discharge is the most common method used), to maximize attraction and capture of aerosols and solid particulates. Under normal circumstances, the reuse of masks is generally discouraged, but in times of crisis has become a necessity, making disinfection after each use a necessity. To be acceptable, any disinfection procedure must cause minimal degradation to the performance of the filter material. Possible performance degradation mechanisms include mechanical damage, loss of electrostatic charge, or both. One of the most practical and direct ways to measure combined mechanical and electrostatic integrity, and the subsequent ability to reuse mask filter material, is by the direct measurement of filtration efficiency. In this paper, we report that small numbers of disinfection cycles at reasonable virucidal doses of ozone do not significantly degrade the filtration efficiency of meltblown polypropylene filter material. By comparison, laundering quickly results in a significant loss of filtration efficiency and requires subsequent recharging to restore the electrostatic charge and filtration efficiency. A common assumption among biomedical scientists that ozone is far too destructive for this application. However, these direct measurements show that mask materials, specifically the filtration material, can withstand dozens of ozone disinfection cycles without any measurable degradation of filtration efficiency, nor any visible discoloration or loss of fiber integrity. The data are clear: when subjected to a virucidal dose of ozone for a much longer duration than is required for viral inactivation, there was no degradation of N95 filtration efficiency. The specific dosages of ozone needed for ~99% viral inactivation are thought to be at least 10 ppm for up to 30 minutes based upon an extensive literature review, but to standardize our testing, we consider a dose of 20 ppm for 30 minutes to be a reasonable and conservatively high ozone disinfection cycle. Finally, the material tested in this study withstood dosages of up to 200 ppm for 90 minutes, or alternatively 20 ppm for up to 36 hours, without detectable degradation, and further testing suggests that up to 30 or more disinfection cycles (at 20 ppm for 30 minutes) would result in less than a 5% loss of filtration efficiency. This report does not address the effect of ozone cycling on other mask components, such as elastics.

60 APPLIED LIFE SCIENCES↗

Multiresolution persistent homology for excessively large biomolecular datasets

Although persistent homology has emerged as a promising tool for the topological simplification of complex data, it is computationally intractable for large datasets. We introduce multiresolution persistent homology to handle excessively large datasets. We match the resolution with the scale of interest so as to represent large scale datasets with appropriate resolution. We utilize flexibility-rigidity index to access the topological connectivity of the data set and define a rigidity density for the filtration analysis. By appropriately tuning the resolution of the rigidity density, we are able to focus the topological lens on the scale of interest. The proposed multiresolution topological analysis is validated by a hexagonal fractal image which has three distinct scales. We further demonstrate the proposed method for extracting topological fingerprints from DNA molecules. In particular, the topological persistence of a virus capsid with 273 780 atoms is successfully analyzed which would otherwise be inaccessible to the normal point cloud method and unreliable by using coarse-grained multiscale persistent homology. The proposed method has also been successfully applied to the protein domain classification, which is the first time that persistent homology is used for practical protein domain analysis, to our knowledge. The proposed multiresolution topological method has potential applications in arbitrary data sets, such as social networks, biological networks, and graphs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Particle size influences decay rates of environmental DNA in aquatic systems

Abstract Environmental DNA (eDNA) analysis is a powerful tool for remote detection of target organisms. However, obtaining quantitative and longitudinal information from eDNA data is challenging, requiring a deep understanding of eDNA ecology. Notably, if the various size components of eDNA decay at different rates, and we can separate them within a sample, their changing proportions could be used to obtain longitudinal dynamics information on targets. To test this possibility, we conducted an aquatic mesocosm experiment in which we separated fish‐derived eDNA components using sequential filtration to evaluate the decay rate and changing proportion of various eDNA particle sizes over time. We then fit four alternative mathematical decay models to the data, building towards a predictive framework to interpret eDNA data from various particle sizes. We found that medium‐sized particles (1–10 μm) decayed more slowly than other size classes (i.e., <1 and > 10 μm), and thus made up an increasing proportion of eDNA particles over time. We also observed distinct eDNA particle size distribution (PSD) between our Common carp and Rainbow trout samples, suggesting that target‐specific assays are required to determine starting eDNA PSDs. Additionally, we found evidence that different sizes of eDNA particles do not decay independently, with particle size conversion replenishing smaller particles over time. Nonetheless, a parsimonious mathematical model where particle sizes decay independently best explained the data. Given these results, we suggest a framework to discern target distance and abundance with eDNA data by applying sequential filtration, which theoretically has both metabarcoding and single‐target applications.

Brandão‐Dias, Pedro F. P.↗

Current status of cadmium as an environmental health problem

Cadmium is a toxic metal occurring in the environment naturally and as a pollutant emanating from industrial and agricultural sources. Food is the main source of cadmium intake in the non-smoking population. The bioavailability, retention and toxicity are affected by several factors including nutritional status such as low iron status. Cadmium is efficiently retained in the kidney (half-time 10-30 years) and the concentration is proportional to that in urine (U-Cd). Cadmium is nephrotoxic, initially causing kidney tubular damage. Cadmium can also cause bone damage, either via a direct effect on bone tissue or indirectly as a result of renal dysfunction. After prolonged and/or high exposure the tubular injury may progress to glomerular damage with decreased glomerular filtration rate, and eventually to renal failure. Furthermore, recent data also suggest increased cancer risks and increased mortality in environmentally exposed populations. Dose-response assessment using a variety of early markers of kidney damage has identified U-Cd points of departure for early kidney effects between 0.5 and 3 {mu}g Cd/g creatinine, similar to the points of departure for effects on bone. It can be anticipated that a considerable proportion of the non-smoking adult population has urinary cadmium concentrations of 0.5 {mu}g/g creatinine or higher in non-exposed areas. For smokers this proportion is considerably higher. This implies no margin of safety between the point of departure and the exposure levels in the general population. Therefore, measures should be put in place to reduce exposure to a minimum, and the tolerably daily intake should be set in accordance with recent findings.

60 APPLIED LIFE SCIENCES↗

Modeling Evolvable Water Recovery Systems for Short and Long-Duration Missions in Partial Gravity

Water recovery technologies on the International Space Station (ISS) are designed and optimized for microgravity environments, thus creating a need for innovative systems optimized for mission operations in the presence of gravity. Alternative water recovery technologies under research by the Life Support Systems division were compiled into a series of Partial Gravity Water Recovery System (PGWRS) architectures. Individual unit processes were modeled via fundamental physical-chemical process equations to simulate their method of treatment, including chemical or biological oxidation, flash evaporation, filtration, or adsorption and ion exchange. Dimension and sizing data were then utilized to scale each architecture. Modeling was completed on an assortment of architectures assuming three scenarios in which treatment methods could take advantage of partial gravity: a short-duration mission with a temporary surface habitat, a longer duration mission with a more permanent habitat, and a long duration mission with minimal resupply. Total system mass was estimated to quantitatively compare architectures within scenarios, but qualitative observations were also made regarding system robustness, flexibility, and capacity to meet more stringent demands. Technologies that traded most favorably between the scenarios were those that included a pre-oxidation stage to minimize mass loading to downstream absorption and ion exchange beds, exploited gravity in liquid-vapor separation processes, and reconstituted wastewater components into recyclable material streams.

Avery L. Carlson↗

Modeling Evolvable Water Recovery Systems for Short and Long-Duration Missions in Partial Gravity

Water recovery technologies on the International Space Station (ISS) are designed and optimized for microgravity environments, thus creating a need for innovative systems optimized for mission operations in the presence of gravity. Alternative water recovery technologies under research by the Life Support Systems division were compiled into a series of Partial Gravity Water Recovery System (PGWRS) architectures. Individual unit processes were modeled via fundamental physical-chemical process equations to simulate their method of treatment, including chemical or biological oxidation, flash evaporation, filtration, or adsorption and ion exchange. Dimension and sizing data were then utilized to scale each architecture. Modeling was completed on an assortment of architectures assuming three scenarios in which treatment methods could take advantage of partial gravity: a short-duration mission with a temporary surface habitat, a longer duration mission with a more permanent habitat, and a long duration mission with minimal resupply. Total system mass was estimated to quantitatively compare architectures within scenarios, but qualitative observations were also made regarding system robustness, flexibility, and capacity to meet more stringent demands. Technologies that traded most favorably between the scenarios were those that included a pre-oxidation stage to minimize mass loading to downstream absorption and ion exchange beds, exploited gravity in liquid-vapor separation processes, and reconstituted wastewater components into recyclable material streams.

Avery Carlson↗

A BPF-FBP tandem algorithm for image reconstruction in reverse helical cone-beam CT

Purpose: Reverse helical cone-beam computed tomography (CBCT) is a scanning configuration for potential applications in image-guided radiation therapy in which an accurate anatomic image of the patient is needed for image-guidance procedures. The authors previously developed an algorithm for image reconstruction from nontruncated data of an object that is completely within the reverse helix. The purpose of this work is to develop an image reconstruction approach for reverse helical CBCT of a long object that extends out of the reverse helix and therefore constitutes data truncation. Methods: The proposed approach comprises of two reconstruction steps. In the first step, a chord-based backprojection-filtration (BPF) algorithm reconstructs a volumetric image of an object from the original cone-beam data. Because there exists a chordless region in the middle of the reverse helix, the image obtained in the first step contains an unreconstructed central-gap region. In the second step, the gap region is reconstructed by use of a Pack-Noo-formula-based filteredbackprojection (FBP) algorithm from the modified cone-beam data obtained by subtracting from the original cone-beam data the reprojection of the image reconstructed in the first step. Results: The authors have performed numerical studies to validate the proposed approach in image reconstruction from reverse helical cone-beam data. The results confirm that the proposed approach can reconstruct accurate images of a long object without suffering from data-truncation artifacts or cone-angle artifacts. Conclusions: They developed and validated a BPF-FBP tandem algorithm to reconstruct images of a long object from reverse helical cone-beam data. The chord-based BPF algorithm was utilized for converting the long-object problem into a short-object problem. The proposed approach is applicable to other scanning configurations such as reduced circular sinusoidal trajectories.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Should WIPP Resume Unfiltered Discharge of Underground Ventilation?

On February 14, 2014 an incident in Panel 7, Room 7 of the Waste Isolation Pilot Plant (WIPP) underground repository resulted in the release of americium and plutonium (mostly {sup 241}Am) into the environment and contaminated portions of the repository primarily along the ventilation path from the location of the incident. The WIPP uses a ventilation system to ensure that underground air is circulated throughout the repository and to ensure that conditions are safe for the workers. Since the air in the repository exits to the surface through an exhaust shaft, this shaft is the sole potential pathway for airborne radioactivity release from the repository. During normal operations, exhaust air is released to the environment unfiltered. However, since the radiation release event, the WIPP ventilation system has been, and will likely remain in what is called 'filtration mode', (i.e., exhaust air is routed through a HEPA filter system). Redirection of the ventilation system through the HEPA (High Efficiency Particulate Air) filter system was necessary at the peak of the radiation release event to protect aboveground workers at the site and the public in the surrounding areas. However, evaluation of more than two years of underground ventilation sampling data indicates that residual radioactivity levels in the underground no longer warrant HEPA filtration in order to meet either worker or environmental protection criteria. WIPP should consider resumption of the unfiltered discharge of underground ventilation to the environment. Recent sampling data indicate that there have been no detectable releases that would have resulted in a hypothetical dose to a worker or a member of the public in excess of the 0.1 mSv (10 mrem) per year limit for periodic confirmatory sampling as required for operating repositories by the Environmental Protection Agency (40 CFR 191)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Observation of radon mitigation in MicroBooNE by a liquid argon filtration system

We report the MicroBooNE liquid argon time projection chamber (LArTPC) maintains a high level of liquid argon purity through the use of a filtration system that removes electronegative contaminants in continuously-circulated liquid, recondensed boil off, and externally supplied argon gas. We use the MicroBooNE LArTPC to reconstruct MeV-scale radiological decays. Using this technique we measure the liquid argon filtration system's efficacy at removing radon. This is studied by placing a 500 kBq 222 Rn source upstream of the filters and searching for a time-dependent increase in the number of radiological decays in the LArTPC. In the context of two models for radon mitigation via a liquid argon filtration system, a slowing mechanism and a trapping mechanism, MicroBooNE data supports a radon reduction factor of greater than 97% or 99.999%, respectively. Furthermore, a radiological survey of the filters found that the copper-based filter material was the primary medium that removed the 222 Rn. This is the first observation of radon mitigation in liquid argon with a large-scale copper-based filter and could offer a radon mitigation solution for future large LArTPCs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-J-183: Interior Region-Of-Interest Tomography by Using Inverse Geometry System

Purpose: The inverse geometry computed tomography (IGCT) composed of multiple source and small size detector has several merits such as reduction of scatter effect and large volumetric imaging within one rotation without cone-beam artifact, compared to conventional cone-beam computed tomography (CBCT). By using this multi-source characteristics, we intend to present a selective and multiple interior region-of-interest (ROI) imaging method by using a designed source on-off sequence of IGCT. Methods: All of the IGCT sources are operated one by one sequentially, and each projection in the shape of narrow cone-beam covers its own partial volume of full field of view (FOV) determined from system geometry. Thus, through controlling multi source operation, limited irradiation within ROI is possible and selective radon space data for ROI imaging can be acquired without additional X-ray filtration. With this feature, we designed a source on-off sequence for multi ROI-IGCT imaging, and projections of ROI-IGCT were generated by using the on-off sequence. Multi ROI-IGCT images were reconstructed by using filtered back-projection algorithm. All these imaging process of our study has been performed by utilizing digital phantom and patient CT data. ROI-IGCT images of the phantom were compared to CBCT image and the phantom data for the image quality evaluation. Results: Image quality of ROI-IGCT was comparable to that of CBCT. However, the distal axial-plane from the FOV center, large cone-angle region, ROI-IGCT showed uniform image quality without significant cone-beam artifact contrary to CBCT. Conclusion: ROI-IGCT showed comparable image quality and has the capability to provide multi ROI image within a rotation. Projection of ROI-IGCT is performed by selective irradiation, hence unnecessary imaging dose to non-interest region can be reduced. In this regard, it seems to be useful for diagnostic or image guidance purpose in radiotherapy such as low dose target localization and patient alignment. This research was supported by the Mid-career Researcher Program through NRF funded by the Ministry of Science, ICT & Future Planning of Korea (NRF-2014R1A2A1A10050270) and by the Radiation Technology R&D program through the National Research Foundation of Korea funded by the Ministry of Science, ICT & Future Planning (No. 2013M2A2A7038291)

60 APPLIED LIFE SCIENCES↗

The Development of Legacy Waste Scaling Factors for Radioactively Contaminated Soils at Chalk River Laboratories - 19333

The Chalk River Laboratories (CRL) began nuclear operations in 1947. Beginning in 1952 after the NRX accident, the management of excess contaminated liquids from the accident, and later in 1953, other waste liquids, were intermittently dispersed to trenches and pits in the local sand. The local sands proved effective at immobilization of actinides, and most activation and fission products. However there was very limited retention of some more commonly mobile radionuclides. Sand filtration performance and radionuclide migration was studied beginning in 1952. Monitoring data indicated slow migration of most radioactive contaminants away from the trenches and pits due to the adsorbing capacity of the sand substrate. The radionuclide migration continues to be studied today in frequent plume monitoring studies. Because many hard-to measure (HTM) radionuclides may also present as long term dose contributors in post remediation scenarios, or in disposal site performance assessments, the quantification of these HTM radionuclides is important. The use of scaling factors between HTM radionuclides and easy-to-measure (ETM) radionuclides (gamma emitters) for packaged soil wastes would alleviate significant effort in sampling individual waste containers. As part of plume monitoring studies and the environmental remediation process, significant characterization of soils have been performed at the site. The soil sample data from multiple historic waste management areas across site is combined and relationships between HTM radionuclides and ETM or key radionuclides are examined. Additional (secondary) relationships between ETM key nuclides are also explored to evaluate secondary scaling relationships between ETM key radionuclides (e.g., Co- 60/Cs-137), because of the significant decay of the activation product key radionuclide Co-60, (predominantly 10-20 half-lives). The evaluation is yielding consistent scaling factors for legacy soil wastes in the historic waste management areas. Given the hydrogeology of the site, a sandy shallow unconfined aquifer, and the annual precipitation of about 0.85 m/a, this evaluation reveals some expected relationships between fission products and actinides and some unanticipated relationships between more mobile radionuclides and key gamma emitters. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of an Indexing Media Filtration System for Long Duration Space Missions

The effective maintenance of air quality aboard spacecraft cabins will be vital to future human exploration missions. A key component will be the air cleaning filtration system which will need to remove a broad size range of particles including skin flakes, hair and clothing fibers, other biological matter, and particulate matter derived from material and equipment wear. In addition, during surface missions any extraterrestrial planetary dust, including dust generated by near-by ISRU equipment, which is tracked into the habitat will also need to be managed by the filtration system inside the pressurized habitat compartments. An indexing media filter system is being developed to meet the demand for long-duration missions that will result in dramatic increases in filter service life and loading capacity, and will require minimal crew involvement. These features may also benefit other closed systems, such as submarines, and remote location terrestrial installations where servicing and replacement of filter units is not practical. The filtration system consists of three stages: an inertial impactor stage, an indexing media stage, and a high-efficiency filter stage, packaged in a stacked modular cartridge configuration. Each stage will target a specific range of particle sizes that optimize the filtration and regeneration performance of the system. An 1/8th scale and full-scale prototype of the filter system have been fabricated and have been tested in the laboratory and reduced gravity environments that simulate conditions on spacecrafts, landers and habitats. Results from recent laboratory and reducegravity flight tests data will be presented.

Filtration↗

Modification of the TASMIP x-ray spectral model for the simulation of microfocus x-ray sources

Purpose: The availability of accurate and simple models for the estimation of x-ray spectra is of great importance for system simulation, optimization, or inclusion of photon energy information into data processing. There is a variety of publicly available tools for estimation of x-ray spectra in radiology and mammography. However, most of these models cannot be used directly for modeling microfocus x-ray sources due to differences in inherent filtration, energy range and/or anode material. For this reason the authors propose in this work a new model for the simulation of microfocus spectra based on existing models for mammography and radiology, modified to compensate for the effects of inherent filtration and energy range. Methods: The authors used the radiology and mammography versions of an existing empirical model [tungsten anode spectral model interpolating polynomials (TASMIP)] as the basis of the microfocus model. First, the authors estimated the inherent filtration included in the radiology model by comparing the shape of the spectra with spectra from the mammography model. Afterwards, the authors built a unified spectra dataset by combining both models and, finally, they estimated the parameters of the new version of TASMIP for microfocus sources by calibrating against experimental exposure data from a microfocus x-ray source. The model was validated by comparing estimated and experimental exposure and attenuation data for different attenuating materials and x-ray beam peak energy values, using two different x-ray tubes. Results: Inherent filtration for the radiology spectra from TASMIP was found to be equivalent to 1.68 mm Al, as compared to spectra obtained from the mammography model. To match the experimentally measured exposure data the combined dataset required to apply a negative filtration of about 0.21 mm Al and an anode roughness of 0.003 mm W. The validation of the model against real acquired data showed errors in exposure and attenuation in line with those reported for other models for radiology or mammography. Conclusions: A new version of the TASMIP model for the estimation of x-ray spectra in microfocus x-ray sources has been developed and validated experimentally. Similarly to other versions of TASMIP, the estimation of spectra is very simple, involving only the evaluation of polynomial expressions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗