Search NASA⌕ Search

SEARCH · Search NASA

Results for “delta rays”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

ASCA solid state imaging spectrometer observations of O stars

We report ASCA Solid State Imaging Spectrometer (SIS) x-ray observations of the O stars delta Ori and lambda Ori. The energy resolution of the SIS allows us to resolve features in the O star x-ray spectra which are not apparent in spectra obtained by x-ray spectrometers with lower energy resolution. SIS spectra from both stars show evidence of line emission, suggesting the thermal nature of the x-ray source. However, the observed line strengths are different for the two stars. The observed stellar x-ray spectra are not well described by isothermal models although absorbed thermal emission models with two or more temperatures can provide an adequate fit to the data. For both stars we present evidence of absorbing columns significantly larger than the known ISM columns, indicative of absorption by a circumstellar medium, presumably the stellar winds. In addition, the lambda Ori spectrum shows the presence of emission at energies greater than 3 keV which is not seen in the delta Ori spectrum.

Corcoran, M. F.↗

ASCA solid state imaging spectrometer observations of O stars

We report ASCA Solid State Imaging Spectrometer (SIS) X-ray observations of the O stars delta Ori and lambda Ori. The energy resolution of the SIS allows us to resolve features in the O star X-ray spectra which are not apparent in spectra obtained by X-ray spectrometers with lower energy resolution. SIS spectra from both stars show evidence of line emission, suggesting the thermal nature of the X-ray source. However, the observed line strengths are different for the two stars. The observed stellar X-ray spectra are not well described by isothermal models although absorbed thermal emission models with two or more temperatures can provide an adequate fit to the data. For both stars we present evidence of absorbing columns significantly larger than the known Interstellar Medium (ISM) columns, indicative of absorption by a circumstellar medium, presumably the stellar winds. In addition, the lambda Ori spectrum shows the presence of emission at energies greater than 3 keV which is not seen in the delta Ori spectrum.

Corcoran, M. F.↗

Einstein observations of three classical Cepheids

We have looked for X-ray emission from the classical Cepheids delta Cep, beta Dor, and zeta Gem during phases when the latter two stars show emission in low excitation chromospheric lines. No X-ray flux was detected except possibly from zeta Gem at phase 0.26. Derived upper limits are in line with emission flux or upper limits obtained for other F and G supergiants.

Bohm-Vitense, E.↗

A Broadband Superconducting Detector Suitable for Use in Large Arrays

Cryogenic detectors are extremely sensitive and have a wide variety of applications (particularly in astronomy), but are difficult to integrate into large arrays like a modern CCD (charge-coupled device) camera. As current detectors of the cosmic microwave background (CMB) already have sensitivities comparable to the noise arising from the random arrival of CMB photons, the further gains in sensitivity needed to probe the very early Universe will have to arise from large arrays. A similar situation is encountered at other wavelengths. Single-pixel X-ray detectors now have a resolving power of (Delta)E < 5 eV for single 6-keV photons, and future X-ray astronomy missions anticipate the need for 1,000-pixel arrays. Here we report the demonstration of a superconducting detector that is easily fabricated and can readily be incorporated into such an array. Its sensitivity is already within an order of magnitude of that needed for CMB observations, and its energy resolution is similarly close to the targets required for future X-ray astronomy missions.

Day, Peter K.↗

X-ray photoelectron spectroscopy study of chemically-etched Nd-Ce-Cu-O surfaces

Acetic acid, Br2, and HCl solutions are investigated for removing insulating species from Nd(1.85)Ce(0.15)CuO(4-delta) (NCCO) thin film surfaces. X-ray photoelectron spectroscopy (XPS) shows that the HCl etch is most effective, yielding O 1s spectra comparable to those obtained from samples cleaned in vacuum and a clear Fermi edge in the valence band region. Reduction and oxidation reversibly induces and eliminates, respectively, Fermi level states for undoped samples, but has no clearly observable effect on the XPS spectra for doped samples. Reactivity to air is much less for NCCO compared to hole superconductors, which is attributed to the lack of reactive alkaline earth elements in NCCO.

Vasquez, R. P.↗

The x-ray spectra of O stars

Under the ASCA AO-1 GO Program, an effective exposure time of 17.8 ksec was obtained to investigate the X-ray emission from the O9.5 II star, Delta Ori. The observation was accomplished on March 15, 1994. The main purpose of the observation was spectroscopy to search for evidence of X-ray line emission throughout the ASCA SIS bandpass, and stellar wind absorption at X-ray energies below 1 KeV.

Corcoran, Michael Francis↗

The Chandra Delta Ori Large Project: Occultation Measurements of the Shocked Gas tn the Nearest Eclipsing O-Star Binary

Delta Ori is the nearest massive, single-lined eclipsing binary (O9.5 II + B0.5III). As such it serves as a fundamental calibrator of the mass-radius-luminosity relation in the upper HR diagram. It is also the only eclipsing O-type binary system which is bright enough to be observable with the CHANDRA gratings in a reasonable exposure. Studies of resolved X-ray line complexes provide tracers of wind mass loss rate and clumpiness; occultation by the X-ray dark companion of the line emitting region can provide direct spatial information on the location of the X-ray emitting gas produced by shocks embedded in the wind of the primary star. We obtained phase-resolved spectra with Chandra in order to determine the level of phase-dependent vs. secular variability in the shocked wind. Along with the Chandra observations we obtained simultaneous photometry from space with the Canadian MOST satellite to help understand the relation between X-ray and photospheric variability.

eclipsing binary↗

Nonpotential magnetic fields at sites of gamma ray flares

The relation between the degree of nonpotentiality of photospheric magnetic fields and the occurrence of gamma ray flares is examined. The parameter delta phi (magnetic shear) and the strength of the magnetic field intensity are used as measures of the degree of nonpotentiality, where delta phi is defined as the angular difference between the observed direction of the transverse component of the photospheric field and the direction of the potential field prescribed by the distribution of measured photospheric flux. An analysis of the great flare of April 24 to 25, 1984 is presented as an example of this technique to quantify the nonpotential characteristics of the pre-flare magnetic field. For this flare, which produced a large gamma ray event, strong shear and high field strengths prevailed over an extended length of the magnetic neutral line where the flare occurred. Moreover, the flare began near the area of strongest measured shear (89 to 90 deg). Four other flaring regions were analyzed; one of these produced a moderate gamma ray event while the other three did not produce detectable gamma rays. For all four regions the flares were located in the area where the field was not nonpotential, regardless of the class of flare. The fields of the gamma ray flares were compared with those associated with the flares without gamma rays, and little distinction was found in the degree of magnetic shear. The major difference is seen in the extent of the sheared field: for gamma ray events, the field is sheared over a longer length of the neutral line.

Hagyard, M. J.↗

Delta XTE Lift and Mate at Complex 17A

This NASA Kennedy Space Center (KSC) video release presents footage of the lift and mate of NASA's X-ray Timing Explorer (XTE) to a McDonnell Douglas Delta II rocket at Launch Complex 17A, Cape Canaveral Air Station. The video includes shots of the workcrews as well as wide angle views of the spacecraft in its launching position. The XTE was launched into a circular orbit with an altitude of 600 km and an inclination of 23 degrees on Dec. 30, 1995.

Source record↗

Research and Development of Satellites, Small Expendable Deployer System (SEDS)

The work proposed in this task order was successfully accomplished. This is reflected in the approval by three NASA centers of the Students for the Exploration and Development of Space Satellite (SEDSAT) to fly as a payload on the shuttle. All documentation necessary for evaluation of the satellite as a Shuttle payload was submitted and approved by the appropriate safety boards. The Small Expendable Deployer System - SEDS - Earth Atmosphere and Space Imaging System (SEASIS) instrument was demonstrated to work and its inclusion as a SEDSAT payload was accomplished in the task period. Finally, the SEDSAT interface to the NASA GSFC PES was approved by MSFC and GSFC with no substantive issues outstanding. As of the end of the contract date all milestones were met. However the NASA MSFC SEDS program was canceled by the center. Since that time SEDSAT has gone on to be manifested on a Delta vehicle.

Wingo, Dennis Ray↗

Demonstration of Time Domain Multiplexed Readout for Magnetically Coupled Calorimeters

Magnetically coupled calorimeters (MCC) have extremely high potential for x-ray applications due to the inherent high energy resolution capability and being non-dissipative. Although very high energy-resolution has been demonstrated, until now there has been no demonstration of multiplexed read-out. We report on the first realization of a time domain multiplexed (TDM) read-out. While this has many similarities with TDM of transition-edge-sensors (TES), for MGGs the energy resolution is limited by the SQUID read-out noise and requires the well established scheme to be altered in order to minimize degradation due to noise aliasing effects. In cur approach, each pixel is read out by a single first stage SQUID (SQ1) that is operated in open loop. The outputs of the SQ1 s are low-pass filtered with an array of low cross-talk inductors, then fed into a single-stage SQUID TD multiplexer. The multiplexer is addressed from room temperature and read out through a single amplifier channel. We present results achieved with a new detector platform. Noise performance is presented and compared to expectations. We have demonstrated multiplexed X-ray spectroscopy at 5.9keV with delta_FWHM=10eV. In an optimized setup, we show it is possible to multiplex 32 detectors without significantly degrading the Intrinsic detector resolution.

Porst, J.-P.↗

A Gamma-Ray Burst Trigger Toolkit

The detection rate of a gamma-ray burst detector can be increased by using a count rate trigger with many accumulation times DELTAt and energy bands DELTAE Because a burst's peak flux varies when averaged over different DELTAt and DELTAE the nominal sensitivity (the numerical value of the peak flux) of a trigger system is less important than how much fainter a burst could be at the detection threshold as DELTAt and DELTAE are changed. The relative sensitivity of different triggers can be quantified by referencing the detection threshold back to the peak flux for a fiducial value of DELTAt and DELTA E. This mapping between peak flux values for different sets of DELTAt and DELTAE varies from burst to burst. Quantitative estimates of the burst detection rate for a given detector and trigger system can be based on the observed rate at a measured peak flux value in this fiducial trigger. Predictions of a proposed trigger's burst detection rate depend on the assumed burst population, and these predictions can be wildly in error for triggers that differ significantly from previous missions. I base the fiducial rate on the BATSE observations: 550 bursts per sky above a peak flux of 0.3 ph per square centimeter per second averaged over DELTAt=1.024 sec and DELTAE=50-300 keV. Using a sample of 100 burst lightcurves I find that triggering on any value of DELTAt that is a multiple of 0.064 sec decreases the average threshold peak flux on the 1.024 sec timescale by a factor of 0.6. Extending DELTAE to lower energies includes the large flux of the X-ray background, increasing the background count rate. Consequently a low energy DELTAE is advantageous only for very soft bursts. Whether a large fraction of the population of bright bursts is soft is disputed; the new population of X-ray Flashes is soft but relatively faint.

Band, David L.↗

SWIFT BAT Survey of AGN

We present the results1 of the analysis of the first 9 months of data of the Swift BAT survey of AGN in the 14-195 keV band. Using archival X-ray data or follow-up Swift XRT observations, we have identified 129 (103 AGN) of 130 objects detected at [b] > 15deg and with significance > 4.8-delta. One source remains unidentified. These same X-ray data have allowed measurement of the X-ray properties of the objects. We fit a power law to the logN - log S distribution, and find the slope to be 1.42+/-0.14. Characterizing the differential luminosity function data as a broken power law, we find a break luminosity logL*(ergs/s)= 43.85+/-0.26. We obtain a mean photon index 1.98 in the 14-195 keV band, with an rms spread of 0.27. Integration of our luminosity function gives a local volume density of AGN above 10(exp 41) erg/s of 2.4x10(exp -3) Mpc(sup -3), which is about 10% of the total luminous local galaxy density above M* = -19.75. We have obtained X-ray spectra from the literature and from Swift XRT follow-up observations. These show that the distribution of log nH is essentially flat from nH = 10(exp 20)/sq cm to 10(exp 24)/sq cm, with 50% of the objects having column densities of less than 10(exp 22)/sq cm. BAT Seyfert galaxies have a median redshift of 0.03, a maximum log luminosity of 45.1, and approximately half have log nH > 22.

Tueller, J.↗

Optical scanner

An optical scanner for imaging lines in an object plane onto a linear array in a focal plane either continuously or discretely is described. The scanner consists of a set of four mutually perpendicularly oriented plane corner mirrors which provide a reflecting path that describes a parallelogram. In addition, there is a plane parallel scanning mirror with a front and back reflecting surface located midway between the first and fourth corner mirrors. It is oriented so that in the mid-scan position it is parallel to the first corner mirror, and therefore perpendicular to the fourth corner mirror. As the scan mirror rotates, rays incident from a plurality of lines in the object plane are selectively directed through the optical system arriving at a common intersection on the back surface of the scanning mirror where the rays are colinearly directed toward a lens and then imaged onto the linear array in the focal plane. A set of compensating mirrors may be introduced just before the imaging lens to compensate for a small and generally negligible path difference delta sub l between the axial and marginal rays.

Finkel, Mitchell W.↗

Performance and Characterization of Magnetic Penetration Thermometer Devices for X-Ray Spectroscopy

We are developing magnetic penetration thermometers (MPTs) for applications in X-ray astronomy. These non-dissipative devices consist of an X-ray absorber in good thermal contact to a superconducting thin film with a transition temperature around T=100mK. A microfabricated superconducting planar inductor underneath is used to store a persistent current and couple the superconductor's diamagnetic response to a readout SQUID. The strong temperature dependence of the diamagnetic response make these devices suitable for highly sensitive macroscopic thermometers that are capable of achieving very high energy resolution. We present results achieved with MPTs consisting of MoAu bilayer sensors attached to overhanging square 250 micron by 250 micron gold absorbers that have demonstrated an energy resolution of delta E_FWHM=2.3eV at an X-ray energy of 5.9keV. A similar device has shown delta E_FWHM=2.0eV at 1.5 keV. Under certain conditions and for specific device geometries, the temperature responsivity of the MPTs can vary on long timescales degrading the spectral performance. We present the characterization of different inductor geometries to optimize the design for the highest possible temperature sensitivity and compare different device designs with respect to responsivity stability.

Porst, J. -P.↗

Distance corrections for single- and dual-color lasers by ray tracing

The physical arc length difference between the red and blue beam of a dual-color laser generates an error term in determining Delta-n as well as n (the refractive index) and D (the line length). Numerical ray trace examples and theoretical approximations show that the resulting relative error Delta-D/D increases as D-squared. Error reduction by a factor of nearly 10 is possible by using the pressure, temperature, and humidity of both endpoints to calculate n. The present study results from a desire to improve the precision of monitoring the local and regional position of the Lunar Laser Ranging Observatory atop Haleakala, Maui, Hawaii; the monitoring of the earth's crustal deformation and strain is a primary concern of the study.

Berg, E.↗

Nature and origin of interstellar diamond from the Allende CV3 meteorite

Data and experimental evidence which support the contention that the C delta diamonds may result from grain-grain collisions in supernova shocks in the interstellar medium are presented. Fragments of the Allende CV3 chondrite were acid-treated. A whitish powder was obtained. For the Analytical Electron Microscopy (AEM) a small drop of ethanol suspension was transferred onto holey carbon support films on 3 mm EM grids. The AEM was performed on transmission-thin fragments of the material which overlay holes in the film, to eliminate interference from the substrate. Electron Spectroscopy for Chemical Analysis (ESCA) was performed on a large aliquot of C. Diamond was identified by selected area electron diffraction. Scanning Transmission Electron Microscope / Energy Dispersive X-ray (STEM-EDS) microanalyses of the C delta diamond, using a light-element detector, show that oxygen and possibly nitrogen are the only impurities consistently present. ESCA spectra from bulk C delta material confirm the presence of N at a level of 0.35 percent or less. Under UV irradiation a yellow-red fluorescence is observed, consistent with that of natural diamonds containing substitutional N. Electron Energy Loss Spectra (EELS) were recorded at 2 eV resolution from the C delta diamond, high pressure synthetic diamond, a diamond film produced in a low pressure plasma by chemical vapor deposition (CVD) on a heated silicon substrate (Roy, 1987), graphite, and amorphous arc sputtered carbon. Comparison of the carbon K edge shape and fine structure shows the Allende C delta phase to be largely diamond, but with a significant pre-edge absorption feature indicative of transitions of C 1s electrons into pi asterisk orbitals which are absent in the purely sp(3)-bonded diamond but present in graphite and amorphous carbon.

Blake, David↗

Black hole accretion disks - Electrodynamic coupling of accretion-disk coronae and the partitioning of soft and hard X-ray emission

It is demonstrated that the observed large ratio of hard to soft X-ray emission and the bimodel behavior of black hole accreting X-ray sources such as Cygnus X-1 can be described in terms of a magnetically structured accretion disk corona which is electrodynamically coupled to the disk turbulent motions while the disk is thermodynamically coupled to the corona as described by a feedback parameter delta. The observed ratio of hard to soft X-ray emission is independent of the disk thickness, and weakly dependent of the disk parameter alpha relating the disk viscous stresses to the total pressure. Observed values of the luminosity ratio point towards strong differences of the feedback of the low state compared to the high state, in the sense that low state means small feedback (delta less than 0.2) and high state means strong feedback delta of about 0.5.

Kuperus, M.↗