Search NASA⌕ Search

SEARCH · Search NASA

Results for “detector array readout”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Characterization of EJ-270 and Ce-doped LiCAF scintillators for the development of high-rate neutron reflectometer detectors

The Second Target Station of the Spallation Neutron Source at Oak Ridge National Laboratory is anticipated to provide a neutron source with ∼20 times increase in peak brightness than the First Target Station. The neutron reflectometers currently in operation at the First Target Station need to be upgraded due to the increased neutron flux. A prototype neutron detector module based upon a pixelated scintillator array readout by silicon photomultipliers is being developed to address the high-rate challenge faced with future neutron reflectometer instruments at the Second Target Station. Two types of scintillator materials were considered for this detector development, i.e., 6 Li-loaded EJ-270 plastic scintillator and Ce-doped LiCAF single crystal. This paper reports the scintillator characterization results, including light yield, pulse shape discrimination performance, capability to detect thermal neutrons in a high γ-ray field, and γ-ray sensitivity. The number of photons produced per neutron capture by EJ-270 and LiCAF:Ce was measured to be 2176 ± 91 and 2651 ± 108, respectively. EJ-270 demonstrated a good capability to discriminate between neutrons and γ-rays by employing the commonly used charge comparison method (figure-of-merit: 1.13 ± 0.01 for an energy cut of 292–426 keVee) and a reasonable performance when using the time-over-threshold techniques; however, no discrimination was observed from LiCAF:Ce regardless of the pulse shape discrimination approaches utilized, making pulse height discrimination necessary for LiCAF:Ce to differentiate between neutrons and γ-rays. Both EJ-270 and LiCAF:Ce exhibited an acceptable capacity to detect thermal neutrons at high exposure rates up to approximately 584 mR/h. Furthermore, the γ-ray sensitivities measured with a 60 Co source at an exposure rate of around 1145 mR/h were determined to be (6.11 ± 0.87) × 10 −6 and (7.64 ± 1.08) × 10 −7 for EJ-270 and LiCAF:Ce, respectively.

EJ-270↗

Development of a unit cell for a Ge:Ga detector array

Two modules of gallium-doped germanium (Ge:Ga) infrared detectors with integrated multiplexing readouts and supporting drive electronics were designed and tested. This development investigated the feasibility of producing two-dimensional Ge:Ga arrays by stacking linear modules in a housing capable of providing uniaxial stress for enhanced long-wavelength response. Each module includes 8 detectors (1x1x2 mm) mounted to a sapphire board. The element spacing is 12 microns. The back faces of the detector elements are beveled with an 18 deg angle, which was proved to significantly enhance optical absorption. Each module includes a different silicon metal-oxide semiconductor field effect transistor (MOSFET) readout. The first circuit was built from discrete MOSFET components; the second incorporated devices taken from low-temperature integrated circuit multiplexers. The latter circuit exhibited much lower stray capacitance and improved stability. Using these switched-FET circuits, it was demonstrated that burst readout, with multiplexer active only during the readout period, could successfully be implemented at approximately 3.5 K.

Source record↗

A superconducting nanowire binary shift register

We present a design for a superconducting nanowire binary shift register, which stores digital states in the form of circulating supercurrents in high-kinetic-inductance loops. Adjacent superconducting loops are connected with nanocryotrons, three-terminal electrothermal switches, and fed with an alternating two-phase clock to synchronously transfer the digital state between the loops. A two-loop serial-input shift register was fabricated with thin-film NbN and a bit error rate of less than 10 –4 was achieved, when operated at a maximum clock frequency of 83 MHz and in an out-of-plane magnetic field of up to 6 mT. A shift register based on this technology offers an integrated solution for low-power readout of superconducting nanowire single photon detector arrays and is capable of interfacing directly with room-temperature electronics and operating unshielded in high magnetic field environments.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

CCAT-prime: Designs and status of the first light 280 GHz MKID array and mod-cam receiver

The CCAT-prime project's first light array will be deployed in Mod-Cam, a single-module testbed and first light cryostat, on the Fred Young Submillimeter Telescope (FYST) in Chile's high Atacama desert in late 2022. FYST is a six-meter aperture telescope being built on Cerro Chajnantor at an elevation of 5600 meters to observe at millimeter and submillimeter wavelengths. 1 Mod-Cam will pave the way for Prime-Cam, the primary first generation instrument, which will house up to seven instrument modules to simultaneously observe the sky and study a diverse set of science goals from monitoring protostars to probing distant galaxy clusters and characterizing the cosmic microwave background (CMB). At least one feedhorn-coupled array of microwave kinetic inductance detectors (MKIDs) centered on 280 GHz will be included in Mod-Cam at first light, with additional instrument modules to be deployed along with Prime-Cam in stages. The first 280 GHz detector array was fabricated by the Quantum Sensors Group at NIST in Boulder, CO and includes 3,456 polarization- sensitive MKIDs. Current mechanical designs allow for up to three hexagonal arrays to be placed in each single instrument module. We present details on this first light detector array, including mechanical designs and cold readout plans, as well as introducing Mod-Cam as both a testbed and predecessor to Prime-Cam.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantum Devices for Neutrino and Rare Particle Detection (Final Report)

This report summarizes the technical work completed under the DOE-QuanISED program. This grant allowed the MIT group --and associated groups on the project, including UMass Amherst and Argonne National Laboratory -- to explore the use of superconducting bolometers for the purpose of neutrino and low mass dark matter detection. These low threshold bolometric detection techniques have wide applicability in nuclear and particle physics, including searching for low mass weakly-interacting dark matter; detecting neutrinos via coherent neutrino scattering; searching for axions and nuclear non-proliferation. In addition, we explored how using techniques readily used by the quantum computing community–such as multiplexed microwave resonators and quantum amplifiers—could be used as a low noise readout scheme for an array of superconducting detectors. We briefly summarized the accomplishments under the project, and what future research directions have spawned from this research.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Space infrared telescope facility wide field and diffraction limited array camera (IRAC)

The wide-field and diffraction limited array camera (IRAC) is capable of two-dimensional photometry in either a wide-field or diffraction-limited mode over the wavelength range from 2 to 30 microns with a possible extension to 120 microns. A low-doped indium antimonide detector was developed for 1.8 to 5.0 microns, detectors were tested and optimized for the entire 1.8 to 30 micron range, beamsplitters were developed and tested for the 1.8 to 30 micron range, and tradeoff studies of the camera's optical system performed. Data are presented on the performance of InSb, Si:In, Si:Ga, and Si:Sb array detectors bumpbonded to a multiplexed CMOS readout chip of the source-follower type at SIRTF operating backgrounds (equal to or less than 1 x 10 to the 8th ph/sq cm/sec) and temperature (4 to 12 K). Some results at higher temperatures are also presented for comparison to SIRTF temperature results. Data are also presented on the performance of IRAC beamsplitters at room temperature at both 0 and 45 deg angle of incidence and on the performance of the all-reflecting optical system baselined for the camera.

Fazio, Giovanni G.↗

Modeling Charge Collection in Detector Arrays

A detector array charge collection model has been developed for use as an engineering tool to aid in the design of optical sensor missions for operation in the space radiation environment. This model is an enhancement of the prototype array charge collection model that was developed for the Next Generation Space Telescope (NGST) program. The primary enhancements were accounting for drift-assisted diffusion by Monte Carlo modeling techniques and implementing the modeling approaches in a windows-based code. The modeling is concerned with integrated charge collection within discrete pixels in the focal plane array (FPA), with high fidelity spatial resolution. It is applicable to all detector geometries including monolithc charge coupled devices (CCDs), Active Pixel Sensors (APS) and hybrid FPA geometries based on a detector array bump-bonded to a readout integrated circuit (ROIC).

Hardage, Donna↗

Ultra-Sensitive Transition-Edge Sensors for the Background Limited Infrared/Sub-mm Spectrograph (BLISS)

We report progress in fabricating ultra-sensitive superconducting transition-edge sensors (TESs) for BLISS. BLISS is a suite of grating spectrometers covering 35-433 micron with R approx. 700 cooled to 50 mK that is proposed to fly on the Japanese space telescope SPICA. The detector arrays for BLISS are TES bolometers readout with a time domain SQUID multiplexer. The required noise equivalent power (NEP) for BLISS is NEP = 10(exp -19) W/Hz(exp 1/2) with an ultimate goal of NEP= 5 x 10(exp -20) W/Hz(exp 1/2) to achieve background limited noise performance. The required and goal response times are tau = 150 ms and tau = 50ms respectively to achieve the NEP at the required and goal optical chop frequency 1-5 Hz. We measured prototype BLISS arrays and have achieved NEP = 6 x 10(exp -18) W/Hz(exp 1/2) and tau = 1.4 ms with a Ti TES (T(sub C) = 565 mK) and NEP approx. 2.5 x 10(exp -19) W/Hz(exp 1/2) and tau approximates 4.5 ms with an Ir TES (T(sub C) = 130 mK). Dark power for these tests is estimated at 1-5 fW.

transition-edge sensors (TESs)↗

Superconducting kinetic inductance photon detectors.

We are investigating a novel superconducting detector and readout method that could lead to photon counting, energy resolving focal plane arrays. This concept is intrinsically different from STJ and TES detectors, and in principle could deliver large pixel counts, high sensitivity, and Fano-limited spectral resolution in the ptical/UV/X-ray bands. The readout uses the monotonic relation between the kinetic surface inductance L***subs***, of a superconductor and the density of quasiparticles n, which holds even at temperatures far below T***subc***. This allows a sensitive readout of the number of excess quasiparticles in the detector by monitoring the transmission phase of a resonant circuit. The most intriguing aspect of this concept is that passive frequency multiplexing could be used to read out ~ l0***super4*** detectors with a single HEMT amplifier. Single x-ray events have been observed in prototype detectors.

kinetic↗

Development of a Robust, Efficient Process to Produce Scalable, Superconducting Kilopixel Far-IR Detector Arrays

The far-IR band is uniquely suited to study the physical conditions in the interstellar medium from nearby sources out to the highest redshifts. FIR imaging and spectroscopy instrumentation using incoherent superconducting bolometers represents a high sensitivity technology for many future suborbital and space missions, including the Origins Space Telescope. Robust, high sensitivity detector arrays with several 104 pixels, large focal plane filling factors, and low cosmic ray cross sections that operate over the entire far-IR regime are required for such missions. These arrays could consist of smaller sub-arrays, in case they are tileable. The TES based Backshort Under Grid array architecture which our group has fielded in a number of FIR cameras, is a good candidate to meet these requirements: BUGs are tileable, and with the integration of the SQUID multiplexer scaleable beyond wafer sizes; they provide high filling factors, low cosmic cross section and have been demonstrated successfully in far-infrared astronomical instrumentation. However, the production of BUGs with integrated readout multiplexers has many time and resource consuming process steps. In order to meet the requirement of robustness and efficiency on the production of future arrays, we have developed a new method to provide the superconducting connection of BUG detectors to the readout multiplexers or general readout boards behind the detectors. This approach should allow us to reach the goal to produce reliable, very large detector arrays for future FIR missions.

Staguhn, Johannes↗

A 4 x 4 SiPM Sensor Array with Fast Preamplified Output Engineered for the PWO Detectors of the EIC EEEMCAL

The PbWO4 scintillation detectors for the Electron-Ion Collider Electron Endcap Electromagnetic Calorimeter (EEEMCAL) cannot use vacuum photomultipler tubes due to the high magnetic field environment. We are presenting a readout solution with a 4 x 4 SiPM array directly coupled to a preamplification and summing stage. A second amplification stage with variable gain and offset adjustments is also included in the compact electronics module. The integrated power supply feeds the signal processing chain and the adjustable bias control. The parameter settings are saved locally on a EEPROM and are adjustable via the integrated communication interface through USB or RS485. The design was optimized to maximize signal collection energy resolution, for fast timing and wide dynamic range while keeping a small footprint with low power consumption and heat dissipation. The output response is fast enough to meet the 100 ? 200 ns digitization gate requirements for the detector. The electronics assembly requires no active cooling and includes a temperature sensor and a gain compensation of thermal variations which are important features for stable operation in large scale detector structures. A detector prototype was constructed with 20 mm x 20 mm x 200 mm PWO crystals affixed with individual SiPM array readouts and arranged in a 3 x 3 array. This detector was tested at the Thomas Jefferson National Accelerator Facility with 5GeV positrons. We will present the results of these detector characterization measurements.

Philip, O.↗

Crosstalk Effects in Microwave SQUID Multiplexed TES Bolometer Readout

Transition-edge sensor (TES) bolometers are broadly used for background-limited astrophysical measurements from the far-infrared to mm-waves. Many planned future instruments require increasingly large detector arrays, but their scalability is limited by their cryogenic readout electronics. Microwave SQUID multiplexing offers a highly capable scaling solution through the use of inherently broadband circuitry, enabling readout of hundreds to thousands of channels per microwave line. As with any multiplexing technique, the channelization mechanism gives rise to electrical crosstalk which must be understood and controlled so as to not degrade the instrument sensitivity. Here, in this study, we explore implications relevant for TES bolometer array applications, focusing in particular on upcoming mm-wave observatories such as the Simons Observatory and AliCPT. We model the relative contributions of the various underlying crosstalk mechanisms, evaluate the difference between fixed-tone and tone-tracking readout systems, and discuss ways in which crosstalk nonlinearity will complicate on-sky measurements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The development and test of ultra-large-format multi-anode microchannel array detector systems

The specific tasks that were accomplished with each of the key elements of the multi-anode microchannel array detector system are described. The modes of operation of position-sensitive electronic readout systems for use with high-gain microchannel plates are described and their performance characteristics compared and contrasted. Multi-anode microchannel array detector systems with formats as large as 256 x 1024 pixels are currently under evaluation. Preliminary performance data for sealed ultraviolet and visible-light detector tubes show that the detector systems have unique characteristics which make them complementary to photoconductive array detectors, such as CCDs, and superior to alternative pulse-counting detector systems employing high-gain MCPs.

Timothy, J. G.↗

Study of advanced InSb arrays for SIRTF (Space Infrared Telescope Facility)

The Santa Barbara Research Center has completed a study leading to the development of advanced Indium Antimonide detector arrays for the Space Infrared Telescope Facility (SIRTF) Focal Plane Array Detector (FPAD) Subsystem of the Infrared Array Camera (IRAC) Band 1. The overall goal of the study was to perform design tradeoff studies, analysis and research to develop a Direct Readout Integrated Circuit to be hybridized to an advanced, high performance InSb detector array that would satisfy the technical requirements for Band 1 as specified in the IRAC Instrument Requirements Document (IRD), IRAC-202. The overall goal of the study was divided into both a near-term goal and a far-term goal. The near-term goal identifies current technology available that approaches, and in some cases meets the program technological goals as specified in IRAC-202. The far-term goal identifies technology development required to completely achieve SIRTF program goals. Analyses of potential detector materials indicates that InSb presently meets all Band 1 requirements and is considered to be the baseline approach due to technical maturity. The major issue with regard to photovoltaic detectors such as InSb and HgCdTe is to achieve a reduction in detector capacitance.

Hoffman, Alan↗

A Deposited Magnetic Thermometer for Temperatures below 0.1 Kelvin

Magnetic thermometers are much less sensitive to self-heating due to rf noise than are traditional resistive thermometers. This makes them appealing at temperatures well below 0.1 Kelvin in the operating range of many space-flight detectors. We have developed and tested a magnetic thermometer which is deposited directly onto a substrate. This device, which uses the temperature dependence of iron-doped palladium's magnetic susceptibility, includes self-shielding deposited coils surrounding a sputtered palladium layer. It is read out using a SQUID to achieve high resolution. Its small size and perfect heat sinking should make it useful for the temperature control of space flight detector arrays, in particular those already using SQUID readouts. The design and test results for this device are discussed.

Tuttle, J. G.↗

A Deposited Magnetic Thermometer for Temperatures Below 0.1 Kelvin

Magnetic thermometers are less sensitive to self-heating due to rf noise than are traditional resistive thermometers. This makes them appealing at temperatures well below 0.1 Kelvin in the operating range of many space-flight detectors. We have built and tested a magnetic thermometer which is deposited directly onto a substrate. This device, which uses the temperature dependence of iron-doped palladium s magnetic susceptibility, includes self-shielding deposited coils surrounding a sputtered palladium layer. It is read out using a SQUID to achieve high resolution. Its small size and very good heat-sinking should eventually make it useful for the temperature control of space flight detector arrays, in particular those already using SQUID readouts. The design and test results for this device are discussed.

Tuttle, J. G.↗

The GALILEO γ-ray array at the Legnaro National Laboratories

GALILEO, a new 4 pi high-resolution gamma-detection array, based on HPGe detectors, has been developed and installed at the Legnaro National Laboratories. The GALILEO array greatly benefits from a fully-digital readout chain, customized DAQ, and a variety of complementary detectors to improve the resolving power by the detection of particles, ions or high-energy gamma-ray transitions. In this paper, a full description of the array, including electronics and DAQ, is presented together with its complementary instrumentation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low-background direct readout array performance

The development and evaluation of an integrated array of antimony-doped silicon detectors is described. The spectral range of extrinsic silicon-integrated arrays useful for low-background IR astronomical applications is extended to about 31 microns with this development. The 58 x 62-element array is accessed by a direct readout multiplexer. The device is evaluated with a flexible microcomputer-based drive and readout electronics system in a low-background test dewar. Acceptance testing indicates single-pixel NEPs in the mid-10 to the -18th W/sq rt Hz range, and good global uniformity statistics.

Goebel, J. H.↗