Search NASA⌕ Search

SEARCH · Search NASA

Results for “detector control systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Characterization and Evolution of the Swift X-ray Telescope Instrumental Background

The X-ray telescope (XRT) on board the Swift Gamma Ray Burst Explorer has successfully operated since the spacecraft launch on 20 November 2004, automatically locating GRB afterglows, measuring their spectra and lightcurves and performing observations of high-energy sources. In this work we investigate the properties of the instrumental background, focusing on its dynamic behavior on both long and short timescales. The operational temperature of the CCD is the main factor that influences the XRT background level. After the failure of the Swift active on-board temperature control system, the XRT detector now operates at a temperature range between -75C and -45C thanks to a passive cooling Heat Rejection System. We report on the long-term effects on the background caused by radiation, consisting mainly of proton irradiation in Swift's low Earth orbit and on the short-term effects of transits through the South Atlantic Anomaly (SAA), which expose the detector to periods of intense proton flux. We have determined the fraction of the detector background that is due to the internal, instrumental background and the part that is due to unresolved astrophysical sources (the cosmic X-ray background) by investigating the degree of vignetting of the measured background and comparing it to the expected value from calibration data.

Hill, Joanne↗

Imaging arrangement and microscope

An embodiment of the present invention is an imaging arrangement that includes imaging optics, a fiducial light source, and a control system. In operation, the imaging optics separate light into first and second tight by wavelength and project the first and second light onto first and second areas within first and second detector regions, respectively. The imaging optics separate fiducial light from the fiducial light source into first and second fiducial light and project the first and second fiducial light onto third and fourth areas within the first and second detector regions, respectively. The control system adjusts alignment of the imaging optics so that the first and second fiducial light projected onto the first and second detector regions maintain relatively constant positions within the first and second detector regions, respectively. Another embodiment of the present invention is a microscope that includes the imaging arrangement.

42 ENGINEERING↗

Intercomparison of gamma scattering, gammatography and radiography techniques for mild steel nonuniform corrosion detection

This paper focuses on the mild steel (MS) corrosion detection and intercomparison of results obtained by gamma scattering, gammatography, and radiography techniques. The gamma scattering non-destructive evaluation (NDE) method utilizes scattered gamma radiation for the detection of corrosion, and the scattering experimental setup is an indigenously designed automated personal computer (PC) controlled scanning system consisting of computerized numerical control (CNC) controlled six-axis source detector system and four-axis job positioning system. The system has been successfully used to quantify the magnitude of corrosion and the thickness profile of a MS plate with nonuniform corrosion, and the results are correlated with those obtained from the conventional gammatography and radiography imaging measurements. A simple and straightforward reconstruction algorithm to reconstruct the densities of the objects under investigation and an unambiguous interpretation of the signal as a function of material density at any point of the thick object being inspected is described. In this simple and straightforward method the density of the target need not be known and only the knowledge of the target material's mass attenuation coefficients (composition) for the incident and scattered energies is enough to reconstruct the density of the each voxel of the specimen being studied. The Monte Carlo (MC) numerical simulation of the phenomena is done using the Monte Carlo N-Particle Transport Code (MCNP) and the quantitative estimates of the values of signal-to-noise ratio for different percentages of MS corrosion derived from these simulations are presented and the spectra are compared with the experimental data. The gammatography experiments are carried out using the same PC controlled scanning system in a narrow beam, good geometry setup, and the thickness loss is estimated from the measured transmitted intensity. Radiography of the MS plates is carried out using 160 kV x-ray machine. The digitized radiographs with a resolution of 50 {mu}m are processed for the detection of corrosion damage in five different locations. The thickness losses due to the corrosion of the MS plate obtained by gamma scattering method are compared with those values obtained by gammatography and radiography techniques. The percentage thickness loss estimated at different positions of the corroded MS plate varies from 17.78 to 27.0, from 18.9 to 24.28, and from 18.9 to 24.28 by gamma scattering, gammatography, and radiography techniques, respectively. Overall, these results are consistent and in line with each other.

36 MATERIALS SCIENCE↗

Early detection of deteriorations affecting neutrons boron detectors

The objective of these studies is to design and to industrialize a new device taking back the features of the actual system of control of boron detectors and updating them by adding some analysis of the pulses shapes for predictive maintenance. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optical Detection Of Flameout In A Combustor

Fuel supply shut down in time to prevent explosion. Optical flameout detector designed to signal control system of facility to cut off supply of fuel into combustion chamber if flame goes out. Combustor which optical flameout detector designed burns methane in air to provide hot gases for 8-ft high-temperature test chamber. Acoustical flameout detector for same combustor described in "Acoustical Detection of Flameout in Combustor" (LAR-14900). Fiber optic probes mounted to fuel-spray bar upstream of flame. No focusing optics used, and probes aimed across flow of gases at spot on combustion chamber wall downstream from spray bar. Arrangement enables flameout detection system to respond quickly to potential loss of flame since it detects movement of flame front away from spray bar face. Overall response time of detection system under 10 milliseconds.

Borg, Stephen E.↗

A rocket borne instrument for the study of soft X-ray emission from cosmic X-ray sources

Details about a rocket-borne instrument designed for studying the various characteristics of soft X-ray emission from cosmic X-ray sources in the energy range of 0.2 to 3 keV are presented. The X-ray detector consists of a bank of four multilayer, wall-less proportional counters, each with an area of 400 sq cm. The detectors are covered by windows of 1.4-micron polypropylene and are maintained at a constant pressure in flight using a gas control system. Two of the detectors are equipped with 0.4- by 10-deg collimators for mapping the spatial distribution of soft X-rays from extended X-ray sources. A pair of balanced filters consisting of oxygen and CF4 are used for detecting oxygen emission lines.

Agrawal, P. C.↗

The ADAQ framework: An integrated toolkit for data acquisition and analysis with real and simulated radiation detectors

Here, the ADAQ framework is a collection of software tools that is designed to streamline the acquisition and analysis of radiation detector data produced in modern digital data acquisition (DAQ) systems and in Monte Carlo detector simulations. The purpose of the framework is to maximize user scientific pro-ductivity by minimizing the effort and expertise required to fully utilize radiation detectors in a variety of scientific and engineering disciplines. By using a single set of tools to span the real and simulation domains, the framework eliminates redundancy and provides an integrated workflow for high-fidelity comparison between experimental and simulated detector performance. Built on the ROOT data analysis framework, the core of the ADAQ framework is a set of Cþþ and Python libraries that enable high-level control of digital DAQ systems and detector simulations with data stored into standardized binary ROOT files for further analysis. Two graphical user interface programs utilize the libraries to create powerful tools: ADAQAcquisition handles control and readout of real-world DAQ systems and ADAQAnalysis provides data analysis and visualization methods for experimental and simulated data. At present, the ADAQ framework supports digital DAQ hardware from CAEN S.p.A. and detector simulations performed in Geant4; however, the modular design will facilitate future extension to other manufacturers and simulation platforms.

detector simulation↗

Characterizations of a KHz Pulsed Laser Detection System

A KHz Pulsed Laser Detection System was developed employing the concept of charge integration with an electrometer, in the NASA Goddard Space Flight Center, Code 618 Calibration Lab for the purpose of using the pulsed lasers for radiometric calibration. Comparing with traditional trans-impedance (current-voltage conversion) detection systems, the prototype of this system consists of a UV-Enhanced Si detector head, a computer controlled shutter system and a synchronized electrometer. The preliminary characterization work employs light sources running in either CW or pulsed mode. We believe this system is able to overcome the saturation issue when a traditional trans-impedance detection system is used with the pulsed laser light source, especially with high peak-power pulsed lasers operating at kilohertz repetition rates (e.g. Ekspla laser or KHz OPO). The charge integration mechanism is also expected to improve the stability of measurements for a pulsed laser light source overcoming the issue of peak-to-peak stability. We will present the system characterizations including signal-to-noise ratio and uncertainty analysis and compare results against traditional trans-impedance detection systems.

Ding, Leibo↗

Characterizations of a KHz Pulsed Laser Detection System

A KHz Pulsed Laser Detection System was developed employing the concept of charge integration with an electrometer, in the NASA Goddard Space Flight Center, Code 618 Calibration Lab for the purpose of using the pulsed lasers for radiometric calibration. Comparing with traditional trans-impedance (current-voltage conversion) detection systems, the prototype of this system consists of a UV-Enhanced Si detector head, a computer controlled shutter system and a synchronized electrometer. The preliminary characterization work employs light sources running in either CW or pulsed mode. We believe this system is able to overcome the saturation issue when a traditional trans-impedance detection system is used with the pulsed laser light source, especially with high peak-power pulsed lasers operating at kilohertz repetition rates (e.g. Ekspla laser or KHz OPO). The charge integration mechanism is also expected to improve the stability of measurements for a pulsed laser light source overcoming the issue of peak-to-peak stability. We will present the system characterizations including signal-to-noise ratio and uncertainty analysis and compare results against traditional trans-impedance detection systems.

Ding, Leibo↗

Distributed state machine supervision for long-baseline gravitational-wave detectors

The Laser Interferometer Gravitational-wave Observatory (LIGO) consists of two identical yet independent, widely separated, long-baseline gravitational-wave detectors. Each Advanced LIGO detector consists of complex optical-mechanical systems isolated from the ground by multiple layers of active seismic isolation, all controlled by hundreds of fast, digital, feedback control systems. This article describes a novel state machine-based automation platform developed to handle the automation and supervisory control challenges of these detectors. The platform, called Guardian, consists of distributed, independent, state machine automaton nodes organized hierarchically for full detector control. User code is written in standard Python and the platform is designed to facilitate the fast-paced development process associated with commissioning the complicated Advanced LIGO instruments. While developed specifically for the Advanced LIGO detectors, Guardian is a generic state machine automation platform that is useful for experimental control at all levels, from simple table-top setups to large-scale multi-million dollar facilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SLMod

The software is a modular framework for controlling data acquisition systems (DAQs) for radiation detectors. Its capabilities include hardware configuration and control as well as data readout and storage. In addition to a generalized extensible framework for building DAQs, the package also includes specific implementations for a number of commercially available hardware devices commonly used in nuclear instrumentation (digitizers, high voltage controllers, etc.).

Cabrera-Palmer, Belkis↗

SLMod

The software is a modular framework for controlling data acquisition systems (DAQs) for radiation detectors. Its capabilities include hardware configuration and control as well as data readout and storage. In addition to a generalized extensible framework for building DAQs, the package also includes specific implementations for a number of commercially available hardware devices commonly used in nuclear instrumentation (digitizers, high voltage controllers, etc.).

Source record↗

The EXO-200 detector, part II: auxiliary systems

The EXO-200 experiment searched for neutrinoless double-beta decay of 136 Xe with a single-phase liquid xenon detector. It used an active mass of 110 kg of 80.6%-enriched liquid xenon in an ultra-low background time projection chamber with ionization and scintillation detection and readout. Here, this paper describes the design and performance of the various support systems necessary for detector operation, including cryogenics, xenon handling, and controls. Novel features of the system were driven by the need to protect the thin-walled detector chamber containing the liquid xenon, to achieve high chemical purity of the Xe, and to maintain thermal uniformity across the detector.

47 OTHER INSTRUMENTATION↗

Detection techniques for tenuous planetary atmospheres

The development of new types of detectors for analysis of planetary atmospheres is discussed. Initially, the interest was in detectors for use under partial vacuum conditions. The program has been extended to include detectors for use at one atmosphere and adsorption system for control and separation of gases. Results to date have included detectors for O2 and H2 under partial vacuum conditions. Experiments on detectors for use at high pressures began in 1966, and systems for CO, H2, and O2, were reported. Electrically controlled adsorbent was developed. It was demonstrated that under proper conditions a thin film of semiconductor material could be electrically cycled to adsorb and desorb a specific gas. This work was extended to obtain quantitative data on the use of semiconductors as controllable adsorbents.

Hoenig, S. A.↗

The history of IUE

The early organizational and development history of the NASA-ESA-SERC International UV Explorer (IUE) satellite observatory is reviewed. Consideration is given to the progress of UV astronomy prior to the launch of the IUE in 1978; the initial feasibility and design studies; preliminary proposals (e.g., UVAS) and the reasons for their rejection; the designs selected for the telescope, spectrographs, detectors, and attitude-control system; the preflight preparations; and the commissioning phase.

Boggess, Albert↗

The Role of NASA Engineering & Safety Center (NESC) in Advancing NASA’s Astrophysics Missions (Past, Present, and Future)

The NASA Engineering & Safety Center (NESC) was established in 2003 (after the Columbia accident) to provide an independent technical resource for the resolution of challenging technical problems (through the use of studies, analysis, tests, etc.) for NASA programs and projects. Since its inception, NESC has completed nearly 1000 technical assessments for NASA’s Human Exploration and Operation Mission Directorate (HEOMD), Science Mission Directorate (SMD), Space Technology Mission Directorate (STMD), and Aeronautics Research Mission Directorate (ARMD). Of the SMD related assessments, several were for the resolution of technical problems, analysis, or studies related to NASA’s astrophysics missions in various phases of the project from design to operation. Some of the recent examples of NESC technical support for NASA astrophysics missions have been for: Hubble Space Telescope (HST), Chandra X-ray Observatory (CXO), Fermi Gamma-ray Space Telescope, Kepler Space Telescope, Transiting Exoplanet Survey Satellite (TESS), James Webb Space Telescope (JWST), and Laser Interferometer Space Antenna (LISA). In this paper, we outline some of the technical challenges faced by these astrophysics missions and describe how NESC contributed to their resolution. The case studies cover a wide range of disciplines involving space telescopes, detectors, lasers, and attitude control systems. These efforts include innovative solutions for extending the life of the missions, technical resolution of challenging problems, strategies for risk mitigation, and failure investigations combined with lessons learned reports to advance discipline knowledge, enhance NASA capabilities, and avoid future problems.

NASA↗

Deployment of Diamond-Based Radiation Detector for Very High Dose Rate Measurements - 17042

The diamond-based radiation detector system has been developed at the University of Bristol to measure radiation within nuclear facilities known to exhibit high dose rates. The challenge at Sellafield site in the UK, described herein also applies to many other nuclear operators worldwide, making the transfer of diamond detector technology to other applications feasible. Development of an operator-friendly system, extensive detector testing and controlled calibrations have led to several successful deployments of the device at Sellafield site, providing them with valuable data about the radiological contamination within their highly active plants. Designed for measurements of intense radiation fields, this new tool for characterisation of radiologically hazardous environments is a game-changer, improving the availability and quality of dose rate data used in safety case justifications. Compared with conventional technology diamond detectors are radiation tolerant, miniature, and can measure an extraordinary range of dose rates. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detection techniques for tenuous planetary atmospheres

The development of new types of detectors for analysis of planetary atmospheres is discussed. Initially, the interest was in detectors for use under partial vacuum conditions; recently, the program has been extended to include detectors for use at one atmosphere and adsorption systems for control and separation of gases. Results to date have included detector for O2 and H2 under partial vacuum conditions. Experiments on detectors for use at high pressures began in 1966; and systems for CO, H2, and O2 were reported in 1967 and 1968. In 1968 studies began on an electrically controlled adsorbent. It was demonstrated that under proper conditions a thin film of semiconductor material could be electrically cycled to absorb and desorb a specific gas. This work was extended to obtain quantitative data on the use of semiconductors as controllable adsorbents.

Hoenig, S. A.↗