Search NASA⌕ Search

SEARCH · Search NASA

Results for “detector performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

The 10 to the 8th power bit solid state spacecraft data recorder

The results are summarized of a program to demonstrate the feasibility of Bubble Domain Memory Technology as a mass memory medium for spacecraft applications. The design, fabrication and test of a partially populated 10 to the 8th power Bit Data Recorder using 100 Kbit serial bubble memory chips is described. Design tradeoffs, design approach and performance are discussed. This effort resulted in a 10 to the 8th power bit recorder with a volume of 858.6 cu in and a weight of 47.2 pounds. The recorder is plug reconfigurable, having the capability of operating as one, two or four independent serial channel recorders or as a single sixteen bit byte parallel input recorder. Data rates up to 1.2 Mb/s in a serial mode and 2.4 Mb/s in a parallel mode may be supported. Fabrication and test of the recorder demonstrated the basic feasibility of Bubble Domain Memory technology for such applications. Test results indicate the need for improvement in memory element operating temperature range and detector performance.

Murray, G. W.↗

Temperature Evolution in Excitonic Absorptions of Cd(0.96)Zn(0.04) Materials

We report cryogenic optical properties of Cd(0.96)Zn(0.04)Te wafers that are used as substrate seed layers in HgCdTe focal-plane array detectors. These studies are motivated by the fact that the substrate optical properties influence the overall detector performance. The studies consist of measuring the sample frequency dependent transmittance (T) and reflectance (R) above and below the optical band-gap in the UV/Visible and infrared frequency ranges, and with temperature variation of the sample from 5 to 300 K. These measurements show that the optical gap near 1.49 eV at 300 K increases to 1.62 eV at 5 K. Finally, we observe sharp absorption peaks near this gap energy at low temperatures. The close proximity of these peaks to the optical transition threshold suggests that they originate from the creation of bound electron-hole pairs or excitons. The decay of these excitonic absorptions may contribute to a photoluminescence and transient background response of these back-illuminated HgCdTe CCD detectors.

Quijada, Manuel A.↗

Mirror Illumination and Spillover Measurements of the Atacama Cosmology Telescope

The Atacama Cosmology Telescope (ACT) is a 6 m telescope designed to map the Cosmic Microwave Background (CMB) simultaneously at 145 GHz, 220GHz and 280GHz, The receiver in ACT, the Millimeter Bolometer Array Camera, features 1000 TES bolometers in each band, The detector performance depends critically on the total optical loading, requiring the spmover contributions from the optics to be minimal. This inspired the use of a cold Lyot stop to limit the illumination of the primary and the use of guard rings surrounding the primary and secondary reflectors. Here, we present a direct measurement of the illumination aperture for both reflectors and of the attenuation level outside the main optical path. We used a 145 GHz, 1 m W source and a chopper wheel to produce a time-varying signal with a broad heam proflle, We sampled the response of the camera for different locations of the source, placed in front and beside the primary and secondary mirrors. The aperture of the primary was measured to be 5,72 plus or minus 0,17m in diameter (95 plus or minus 3% of its geometrical size), while the aperture of the secondary yielded 2 plus or minus 0.12m in diameter. Both apertures are consistent with the optical design. Comparing to previous measurements of the beam solid angle from planet observations, we estimate an optical efficiency of 72.3 plus or minus 4,8%. We found that the attenuation outside the primary aperture was -16 plus or minus 2dB, which is below the theoretical expectations, and -22 plus or minus 1 dB outside the secondary aperture, which is consistent with simulations. These results motivated the extension of the baffles surrounding the secondary mirror, with the following reduction in detector optical loading from 2,24 pW to 188pW.

Gallardo, Patricio↗

Detached Melt and Vapor Growth of InI in SUBSA hardware

Indium iodide (InI) single crystals, grown by the Bridgman process, have shown a significant promise as room temperature detector material for X-rays and γ-rays due to the large, close to ideal, bandgap of Eg = 2 eV, and high electrical resistivity. Yet the transport properties of the charge and the detector performance remain inadequate. The Bridgman growth of semiconductor crystals in microgravity have typically resulted in partial dewetting and Marangoni convection, which disturbed the diffusion-controlled growth and produced nonuniform dopant distribution. However, unconfined or partially confined solidification drastically reduced the number of stress-induced defects compared to the confined growth in crucibles on Earth.The goal of the present investigation was to explore melt growth of a heavy metal halide in microgravity, focusing on dewetting, in order to improve the crystalline perfection, i.e., to reduce the number of stress-related defects. InI was chosen because it is non-toxic and has a low melting point of only 365 C (~150 C below the melting point of InSb, used in the SUBSA experiments in 2002). Furthermore, InI melts and evaporates congruently, making it suitable for both growth by directional solidification and growth from the vapor phase. In preparation for the flight experiments, ground-based experiments were conducted in the SUBSA ground unit, consisting of 4 melt growth and 2 vapor growth experiments. The crystals were grown by a gradient freeze method by lowering the setpoint of the furnace. The transparent section of the SUBSA furnace did not allow observations of the solid-liquid interface. Contrary to our expectations, the possible occurrence of dewetting during growth could not be observed. We will present i) the ampoule design and preparation, ii) the experiments conducted in the SUBSA ground unit, iii) the images obtained during the microgravity experiments and iv) the results of the characterization of the grown crystals and detector fabrication.

Crystal Growth↗

Analysis of a Decision-Directed Receiver with Unknown Priors

A decision-directed receiver (DDR) uses previous outputs (decisions) to estimate unknown parameters and, on the basis of these estimates, modifies the detector structure for subsequent decisions. Although the DDR is less complex to instrument than other adaptive schemes, inherent in the decision-directed approach is the possibility of a runaway. This occurs when the detector commits a sequence of decision errors resulting in a degradation of parameter estimates, which, in turn, results in a further deterioration of detector performance. Because of the dependencies introduced by the learning process, runaway is difficult to analyze. In this paper, a DDR with unknown a priori probabilities is considered. The priors are estimated by the relative frequency of decisions of that event. For binary detection, it is shown that there is a positive probability of a runaway (the estimates converge to 1 or 0), which equals 1 if the signal-to-noise ratio is below a critical value. A tight bound on the probability of a runaway is obtained by approximating the learning process by a random walk with independent increments. The analysis demonstrates that a runaway is quite improbable even for moderate signal-to-noise ratios. The analysis is extended to multiple signals and to the situation where the estimates of the priors are updated continuously through exponential weighting rather than allowed to converge.

Davisson, Lee D.↗

Recent progress in the transition radiation detector techniques

A list of some of the major experimental achievements involving charged particles in the relativistic region are presented. With the emphasis mainly directed to the X-ray region, certain modes of application of the transition radiation for the identification and separation of relativistic charged particles are discussed. Some recent developments in detection techniques and improvements in detector performances are presented. Experiments were also carried out to detect the dynamic radiation, but no evidence of such an effect was observed.

Yuan, L. C. L.↗

Cryogenic and low temperature heat pipe/cooler studies for spacecraft application

The prime purpose of the present work is to examine cryogenic heat pipe/cooler feasibility in the 80 to 100 K temperature range and in the regimes of operation required for NASA spacecraft. Present requirements within these regimes are (1) cooling load of less than 1 to 2 watt per cooler, (2) small detector/heat pipe interface area, and (3) high system reliability and long lifetime operations. The cooling capacity of practical radiant coolers is very low in this temperature range, and very temperature sensitive. Detector performance is also strongly dependent on temperatures in this regime. It is, therefore important to understand the interplay of the heat pipe and its effects on overall system performance.

Sherman, A.↗

Simulation of the reconstruction of distorted digital data

Results of simulation runs obtained while varying detector sampling rates and threshold levels for a 20,000 foot equalized cable and a bit rate of 1 Mbs are given. The simulation techniques appear useful for preliminary design of detector levels and sampling rates and for analyzing sensitivity of detector performance as system transfer function parameters are varied.

Zobrist, G. W.↗

Survey report on the state-of-the-art of cryogenic thermometry and signal conditioners and their potential for standardized space hardware

The possibility of standard low temperature detector(s) for use in upcoming cryogenically cooled satellite and Space Shuttle Payloads was investigated. These payloads operate from .3 Kelvin to 300 Kelvin. Standard detectors were selected and matching signal conditioning equipment were specified. This equipment will operate in a spacecraft environment and be compatible with the selected detector, typical spacecraft voltages, typical spacecraft telemetry systems, and the radiation encountered by a typical earth orbiting spacecraft. Work statements to better define and advance detector performance are presented.

Source record↗

A quantitative study of the orientation bias of some edge detector schemes

The article discusses the orientational biases of various edge detection methods. On the basis of ERTS satellite images, three methods are compared: (1) Heuckel's local visual operator (1973), (2) Macleod's Gaussian edge mask detector (1972), and (3) Rosenfeld's local difference calculations (1971). The results yielded by these techniques are compared to the method for quantifying edge detector performance developed by Herskovits (1970).

Deutsch, E. S.↗

Engineering evaluations and studies. Report for IUS studies

The reviews, investigations, and analyses of the Inertial Upper Stage (IUS) Spacecraft Tracking and Data Network (STDN) transponder are reviewed. Carrier lock detector performance for Tracking and Data Relay Satellite System (TDRSS) dual-mode operation is discussed, as is the problem of predicting instantaneous frequency error in the carrier loop. Coastal loop performance analysis is critiqued and the static tracking phase error induced by thermal noise biases is discussed.

Source record↗

A bismuth germanate-shielded mercuric iodide X-ray detector for space applications

The development of HgI2 for solid state X-ray detector applications over the past decade was carried out in connection with the ability of the crystal to operate as a detector at room temperature. In order to achieve the lowest background possible for HgI2 detectors in a space-like environment (balloon and/or satellite altitudes), attention was given to the design of a shielding system which actively vetoes nonaperture events such as gamma rays and charged particles that can mimic signal X-rays by partial deposition of energy in the main detector. The detector system consists of two HgI2 detectors mounted back to back and operated in anticoincidence. The two detectors are placed inside a bismuth germanate scintillating shield along with two hybrid charge-sensitive preamps. Monte Carlo simulations of detector performance are discussed.

Vallerga, J. V.↗

The state-of-the-art of cryogenic thermometry and signal conditioners and their potential for standardized space hardware

The possibility of standard low temperature detector(s) for use in upcoming cryogenically cooled satellite and Space Shuttle payloads were investigated. These payloads operate from .3 kelvin to 300 kelvin. Standard detectors were selected and matching signal conditioning equipment compatible with the selected detector, typical spacecraft voltages, typical spacecraft telemetry systems, and the radiation encountered by a typical Earth orbiting spacecraft. Work statements to better define and advance detector performance were presented.

Source record↗

Highly versatile computer-controlled television detector system

A description is presented of a television detector system which has been designed to accommodate a wide range of applications. It is currently being developed for use in X-ray diffraction, X-ray astrophysics, and electron microscopy, but it is also well suited for astronomical observations. The image can be integrated in a large, high-speed memory system, in the memory of a computer system, or the target of the TV tube or CCD array. The detector system consists of a continuously scanned, intensified SIT vidicon with scan and processing electronics which generate a digital image that is integrated in the detector memory. Attention is given to details regarding the camera system, scan control and image processing electronics, the memory system, and aspects of detector performance.

Kalata, K.↗

Active plasma release experiments

A pulse code modulator (PCM) encoder capable of storing data onboard into the mass memory in the encoder at up to 12 megabits per second was designed and constructed. This telemetry system was programed for two successful flights. All parts of the electronic system functioned perfectly during both previous flights and the detectors performed perfectly. However, in the first flight in Pokerflat, Alaska, an electron arm did not deploy for reasons as yet unkown. The ion arm deployed perfectly and good data was acquired.

Source record↗

Preliminary measurements of very low dark currents in MLA/SWIR HgCdTe/DRO arrays

In infrared astronomy observations, one of the key detector performance parameters is the dark current which, together with the optics, establishes the fundamental limit of a space-based instrument. This technical note summarizes an effort to measure dark current performance of the MLA/Short Wave Infrared photovoltaic HgCdTe array (2.5 micron cutoff) at temperatures from 65 to 120 K. The preliminary results indicate that dark current decreased systematically to 100 K, then the value became measurement-limited at about 3.0 E-18 A/pixel, or 19 electrons/sec/pixel.

Yang, B. T.↗