Search NASA⌕ Search

SEARCH · Search NASA

Results for “detector resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Passive Confirmation of the Presence Of High-Explosive Material Via Neutron Transmission Spectroscopy

The goal of this project was to explore a novel approach for identifying presence and potential types of high explosives (HE) in treaty-controlled items with passive neutron sources by using passive neutron transmission spectroscopy. We predominantly look to measure relative elemental abundance of Carbon, Hydrogen, Oxygen, and Nitrogen (CHON) since most relevant materials are certain mix of these elements, as shown in Table 1. Previously, most studies exploring potential identification of CHON elemental content of targets in the vicinity of passive neutron source were focused solely on gamma spectroscopy using high resolution gamma detectors. Using neutron transmission spectroscopy with pulse-shape discrimination (PSD) capable organic scintillators is not only a novel idea in of itself, but arguably necessary for accurate identification of the CHON elemental content of an interrogated target. While high resolution gamma spectroscopy in principle can determine a presence of hydrogen and nitrogen, it is effectively blind to a quantitatively measuring areal densities of C, O. The initially proposed approach, described in detail in the project proposal, was to leverage previous Monte Carlo study on neutron transmission spectroscopy using slab shaped target interrogated with well-collimated (“pencil”) neutron beam. In this study, a simulated test CO 2 target was interrogated by a pencil neutron beam and transmitted neutron spectra were measured using PSD capable organic scintillator using MLEM based unfolding technique. To establish relative elemental content of carbon and oxygen, the unfolded neutron spectrum was fit with a parametrized combination of their respective elemental spectral templates. The individual spectral template was calculated by convoluting ENDF neutron crosssection with the known resolution of the PSD detector used in the study. This approach in the studied configuration successfully quantitatively established relative elemental composition of carbon and oxygen.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

FRAM Isotopic Analysis of High-Resolution CZT Data

H3D Inc. has introduced a new type of CZT detectors that has resolution several times better than that of a typical, single crystal CZT detector. The better resolution has made it easier for software codes to analyze its spectra for isotopic composition of nuclear materials. The Fixed-energy Response-function Analysis with multiple efficiency (FRAM) is one of such software codes. The good peak resolution of the H3D CZT detectors allows the current FRAM v.6.1 and earlier to successfully analyze uranium spectra with minimal modification of the parameter sets and get reasonable results. (A parameter set governs how an analysis is performed.) The exceptionally large high-energy tail of the peaks makes it difficult to achieve good uranium results and impossible to successfully analyze plutonium spectra. The FRAM code needed to be modified to better fit the high-energy tail of the peaks in order to analyze plutonium data and to get better uranium analysis results. Results of this modification, encoded in beta version FRAM v.7.0i, are reported herein.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Demonstration of Sub-Percent Energy Resolution in the NEXT-100 Detector

NEXT-100 is a high-pressure xenon time projection chamber with electroluminescent amplification, designed to operate with up to approximately 70.5 kg at 13.5 bar. It is the most recent detector developed by the NEXT collaboration to search for the neutrinoless double-beta decay ($ββ0ν$) of Xe-136. The NEXT gas TPC technology offers the best energy resolution near the Q-value of the decay ($Q_{ββ}$ = 2458 keV) among xenon detectors, which is set by design to be <1% FWHM. We report here the high-energy calibration of the detector using a Th-228 source, demonstrating linear response and an energy resolution of $(0.90 \pm 0.02)$% FWHM at the Tl-208 photopeak (2615 keV). This performance extrapolates to a resolution at the double-beta decay end-point of $R(Q_{ββ})$ = $(0.93 \pm 0.02)$% FWHM, confirming the detector's capability for precision energy measurement in the search for $ββ0ν$.

Pérez Maneiro, M. [Santiago de Compostela U., IGFA↗

Search for low-mass electron-recoil dark matter using a single-charge sensitive SuperCDMS-HVeV detector

We present constraints on low-mass dark matter electron scattering and absorption interactions using a SuperCDMS high-voltage eV-resolution (HVeV) detector. Data were taken underground in the NEXUS facility located at Fermilab with an overburden of 225 meters of water equivalent. The experiment benefits from the minimizing of luminescence from the printed circuit boards in the detector holder used in all previous HVeV studies. A blind analysis of 6.1 g · days of exposure produces exclusion limits for dark matter-electron scattering cross sections for masses as low as 1 MeV/𝑐 2 , as well as on the photon-dark photon mixing parameter and the coupling constant between axionlike particles and electrons for particles with masses >1.2 eV/𝑐 2 probed via absorption processes.

dark matter direct detection↗

Search for low-mass electron-recoil dark matter using a single-charge sensitive SuperCDMS-HVeV Detector

We present constraints on low mass dark matter-electron scattering and absorption interactions using a SuperCDMS high-voltage eV-resolution (HVeV) detector. Data were taken underground in the NEXUS facility located at Fermilab with an overburden of 225 meters of water equivalent. The experiment benefits from the minimizing of luminescence from the printed circuit boards in the detector holder used in all previous HVeV studies. A blind analysis of $6.1\,\mathrm{g\cdot days}$ of exposure produces exclusion limits for dark matter-electron scattering cross-sections for masses as low as $1\,\mathrm{MeV}/c^2$, as well as on the photon-dark photon mixing parameter and the coupling constant between axion-like particles and electrons for particles with masses $>1.2\,\mathrm{eV}/c^2$ probed via absorption processes.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Characterizing the energy resolution of the MicroBooNE LArTPC at the MeV scale using monoenergetic features of $^{208}$Tl decays

A detailed understanding of the capabilities and fidelity of low-energy reconstruction is crucial for taking advantage of MeV-scale neutrino physics opportunities in liquid argon time projection chambers (LArTPCs). This study presents a measurement of the resolution of reconstructed energy in the MicroBooNE LArTPC at $\approx 1.5$ MeV. The characterization is performed using monoenergetic signals generated by $2.614$ MeV $γ$-rays from $^{208}$Tl decays undergoing pair production in the detector. The resolution is found to be ($7.52 \pm 0.78 \text{(stat)} \pm 0.92 \text{(syst)}$)%. This value is consistent with the MicroBooNE simulation prediction of ($9.70 \pm 0.65 \text{(stat)}$)% at the $1.6 σ$ level. This study represents the first ever measurement of LArTPC energy resolution at the MeV scale and provides a pathway for monoenergetic energy calibrations in future experiments using LArTPC detectors.

Abratenko, P. [Tufts U.]↗

Picosecond Timing Resolution Measurements of Low Gain Avalanche Detectors with a 120 GeV Proton Beam for the TOPSiDE Detector Concept

This paper presents results that take a critical step toward proving 10 ps timing resolution’s feasibility for particle identification in the TOPSiDE detector concept for the Electron-Ion Collider. Measurements of LGADs with a thickness of 35 μm and 50 μm are evaluated with a 120 GeV proton beam. The performance of the gain and timing response is assessed, including the dependence on the reverse bias voltage and operating temperature. The best timing resolution of UFSDs in a test beam to date is achieved using three combined planes of 35 μm thick LGADs at -30°C with a precision of 14.3 ± 1.5 ps.

Particle tracking detectors↗

The Search for μ+ → e+γ with 10–14 Sensitivity: The Upgrade of the MEG Experiment

The MEG experiment took data at the Paul Scherrer Institute in the years 2009–2013 to test the violation of the lepton flavor conservation law, which originates from an accidental symmetry that the Standard Model of elementary particle physics has, and published the most stringent limit on the charged lepton flavor violating decay μ+→e+γ: BR(μ+→e+γ) <4.2×10−13 at 90% confidence level. The MEG detector has been upgraded in order to reach a sensitivity of 6×10−14. The basic principle of MEG II is to achieve the highest possible sensitivity using the full muon beam intensity at the Paul Scherrer Institute (7×107 muons/s) with an upgraded detector. The main improvements are better rate capability of all sub-detectors and improved resolutions while keeping the same detector concept. In this paper, we present the current status of the preparation, integration and commissioning of the MEG II detector in the recent engineering runs.

physics beyond the Standard Model↗

Interplay between phonon downconversion efficiency, density of states at Fermi energy, and intrinsic energy resolution for microwave kinectic inductance detectors

Microwave Kinetic Inductance detectors (MKIDs) have been recognized as a powerful new tool for single photon detection. These highly multiplexed superconducting devices give timing and energy measurement for every detected photon. However, the full potential of MKID single photon spectroscopy has not been reached , the achieved energy resolution is lower than expected from first principles. Here, we study the efficiency in the phonon downconversion process following the absorption of energetic photons in MKIDs. Assuming previously published material properties, we measure an average downconversion efficiency for three TiN resonators is $\eta$=0.14. We discuss how this efficiency can impact the intrinsic energy resolution of MKID, and how any uncertainty in the unknown density of electron states at the Fermi energy directly affects the efficiency estimations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast Muon Capture Monitoring in Mu2e with the CAPHRI Detector

The Mu2e experiment at Fermilab will search for the charged lepton flavor violating (CLFV) process of a neutrinoless muon-to-electron conversion in the field of an aluminum nucleus. Reaching the experiment’s target sensitivity requires precise normalization of the physics signal through accurate monitoring of the muon capture rate on the stopping target. For this purpose, the Calorimeter Precise High-Resolution Intensity detector (CAPHRI) has been developed. The detector is composed of four LYSO crystals installed in the upstream disk of the Mu2e calorimeter and read out with the standard calorimeter readout. CAPHRI measures the muon capture rate by detecting the characteristic 1.8~MeV gamma emission line of the $^{27}Al(\mu^−, \nu n \gamma) ^{26}Mg$ nuclear reaction. The fast, precise response enables injection-by-injection monitoring of proton beam intensity fluctuations. We report on the commissioning and performance characterization of CAPHRI. The response of each channel is calibrated at two SiPM overvoltages using both the intrinsic self-emission of the LYSO crystals and cosmic ray signals. In parallel, Monte Carlo simulations are used to evaluate the detector acceptance and the expected signal-to-background ratio under realistic running conditions. Preliminary results show a crystal light yield consistent with expectations and a channel inter-calibration at the 2--4% level. Simulation studies indicate that the detector acceptance and background rejection satisfy the requirements for physics operations, with about 1000 detected events per beam injection at a beam power of 1.5~kW. These results demonstrate that CAPHRI is an effective tool for beam monitoring and signal normalization in Mu2e.

Ciccarella, V. [Frascati; U. Rome La Sapienza (mai↗

Exclusion and Verification of Remote Nuclear Reactors with a 1-kiloton Gd -Doped Water Detector

To date, antineutrino experiments built for the purpose of demonstrating a nonproliferation capability have typically employed organic scintillators situated as close to the core as possible (typically at a distance of a few meters to tens of meters) and have not exceeded a few tons in size. One problem with this approach is that proximity to the reactor core requires accommodation by the host facility. Water Cherenkov detectors located offsite, at distances of a few kilometers or greater, may facilitate nonintrusive monitoring and verification of reactor activities over a large area. As the standoff distance increases, the detector target mass must scale accordingly. This paper quantifies the degree to which a kiloton-scale gadolinium-doped water Cherenkov detector can exclude the existence of undeclared reactors within a specified distance, and remotely detect the presence of a hidden reactor in the presence of declared reactors, by verifying the operational power and standoff distance using a Feldman-Cousins-based likelihood analysis. A 1-kton scale (fiducial) water Cherenkov detector can exclude gigawatt-scale nuclear reactors up to tens of kilometers within a year. In conclusion, when attempting to identify the specific range and power of a reactor, the detector energy resolution is not sufficient to delineate between the two.

42 ENGINEERING↗

Beyond the Standard Model physics prospects at DUNE

The Deep Underground Neutrino Experiment (DUNE) is an international project for neutrino physics and proton-decay searches, currently in the design and construction stages. Once built, DUNE will consist of two detectors exposed to the world's most intense neutrino beam. The near detector will record neutrino interactions near the beginning of the beamline, at Fermilab. The other, much larger, detector, comprising four 17-kton liquid argon time projection chambers (LArTPCs), will be installed at a depth of 1.5 km at the Sanford Underground Research Facility in South Dakota, about 1300 km away from the neutrino source.The unique combination of the high-intensity neutrino beam with DUNE's high-resolution near detector system and massive LArTPC far detector enables a variety of probes of BSM physics, either novel or with unprecedented sensitivity, from the potential discovery of new particles (sterile neutrinos or dark matter), to precision tests of the three-flavour neutrino mixing paradigm, or the detailed study of rare processes.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Beyond the Standard Model physics prospects at the Deep Underground Neutrino Experiment

The Deep Underground Neutrino Experiment (DUNE) is an international project for neutrino physics and proton-decay searches, currently in the design and planning stages. Once built, DUNE will consist of two detectors exposed to the world's most intense neutrino beam. The near detector at Fermilab will record neutrino interactions near the beginning of the beam line. The other, much larger, detector, comprising four 10-kton liquid argon time projection chambers (LArTPCs), will be installed at a depth of 1.5 km at the Sanford Underground Research Facility in South Dakota, about 1,300 km away from the neutrino source. The unique combination of the high-intensity neutrino beam, DUNE's high-resolution near detector system, and massive LArTPC far detector enables a variety of probes of Beyond-the-Standard-Model (BSM) physics, from the discovery of new particles (sterile neutrinos or dark matter), to precision tests of beyond the three-flavor mixing paradigm, non-standard neutrino interactions (NSIs), heavy neutral leptons, and the detailed study of rare processes (e.g., neutrino trident production). This article reviews these physics topics and discusses the prospects for their discovery at the DUNE experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Neutron Detectors for Scattering Applications

The book covers, for the first time, the most common neutron detectors used in neutron scattering facilities and all of those in use at Oak Ridge National Lab. The first two chapters describe the facilities, instruments and the critical detector parameters needed by various instruments. The third chapter focuses on the key components of the 3He-based linear position sensitive detectors as well as on their electronics, which require particular attention to signal-processing and noise reduction. The fourth chapter is dedicated to the 3He alternatives where scintillators play a critical role. Finally, chapter 5 covers emerging neutron detection technologies including semiconductors, vacuum-based devices and their associated readouts, which will be required in the future for high rate and high-resolution neutron detectors.

Diawara, Yacouba↗

Novel technique for the study of pileup events in cryogenic bolometers

Precise characterization of detector time resolution is of crucial importance for next-generation cryogenic-bolometer experiments searching for neutrinoless double-beta decay, such as CUPID, in order to reject background due to pile-up of two-neutrino double-beta decay events. In this paper, we describe a technique developed to study the pile-up rejection capability of cryogenic bolometers. Our approach, which consists of producing controlled pile-up events with a programmable waveform generator, has the benefit that we can reliably and reproducibly control the time separation and relative energy of the individual components of the generated pile-up events. The resulting data allow us to optimize and benchmark analysis strategies to discriminate between individual and pile-up pulses. We describe a test of this technique performed with a small array of detectors at the Laboratori Nazionali del Gran Sasso, in Italy; we obtain a 90% rejection efficiency against pulser-generated pile-up events with rise time of ~15 ms down to time separation between the individual events of 2 ms.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Wellbore detector with azimuthal and spectral energy resolution

A wellbore inspection device includes a radiation generation source operable to emit neutrons, and a radiation detector fixed relative to the radiation generation source and operable to detect backscattered neutron radiation from a surrounding environment. The radiation detector includes a plurality of individually addressable detector elements arranged in one or more concentric rings. Respective amounts of backscattered neutron radiation detected by the individually addressable detector elements within a ring is indicative of the azimuthal direction of the detected backscattered neutron radiation, and the respective amount of backscattered neutron radiation detected by the individually addressable detector elements of two or more concentric rings is indicative of an energy level of the backscattered neutron radiation. The inspection device determines whether a potential anomaly is present in or around the wellbore, based at least in part on the respective amounts of backscattered radiation detected by the individually addressable detector elements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High spatial resolution direct conversion amorphous selenium X-ray detectors with monolithically integrated CMOS readout

Recent progress in the field of micron-scale spatial resolution direct conversion X-ray detectors for high-energy synchrotron light sources serve applications ranging from nondestructive and noninvasive microscopy techniques which provide insight into the structure and morphology of crystals, to medical diagnostic measurement devices. Amorphous selenium ( a -Se) as a wide-bandgap thermally evaporated photoconductor exhibits ultra-low thermal generation rates for dark carriers and has been extensively used in X-ray medical imaging. Being an amorphous material, it can further be deposited over large areas at room temperatures and at substantially lower costs as compared to crystalline semiconductors. Here, to address the demands for a high-energy and high spatial resolution X-ray detector for synchrotron light source applications, we have thermally evaporated a -Se on a Mixed-Mode Pixel Array Detector (MM-PAD) Application Specific Integrated Circuit (ASIC). The ASIC format consists of 128 × 128 square pixels each 150 μm on a side. A 200 μm a -Se layer was directly deposited on the ASIC followed by a metal top electrode. The completed detector assembly was tested with 45 kV Ag and 23 kV Cu X-ray tube sources. The detector fabrication, performances, Modulation Transfer Function (MTF) measurements, and simulations are reported.

36 MATERIALS SCIENCE↗