Search NASA⌕ Search

SEARCH · Search NASA

Results for “diameter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Target normal sheath acceleration with a large laser focal diameter

In this work, the dependence of the laser-driven ion acceleration from thin titanium foils in the Target Normal Sheath Acceleration (TNSA) regime on target and laser parameters is explored using two dimensional particle-in-cell simulations. The oblique incidence (θ L = 45°) and large focal spot size (w 0 = 40μm) are chosen to take an advantage of quasi one-dimensional geometry of sheath fields and effective electron heating. This interaction setup also reveals low and achromatic angular divergence of a proton beam. It is shown that the hot electron temperature deviates from the ponderomotive scaling for short laser pulses and small pre-plasmas. This deviation is mainly due to the laser sweeping, as the short duration laser pulse each moment in time effectively heats only a fraction of a focal spot on the foil. This instantaneous partial heating results in an electron temperature deviation from the ponderomotive scaling and, thus, lower maximum proton energies than it could have been expected from the TNSA theory.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measuring type Ia supernova angular-diameter distances with intensity interferometry

This paper investigates the potential of intensity interferometry, based on the Hanbury Brown-Twiss effect, for measuring supernova sizes and distances. With optimized telescope positioning, observing strategy, and advancements in single-photon detection technology, this method can provide precise angular size measurements of supernovae with apparent magnitudes as bright as 12 mag. For type Ia supernovae, this limiting brightness corresponds to a local volume extending to redshift z∼0.004 and an anticipated discovery rate of approximately 1 event per year. The combination of angular size data with known physical dimensions enables accurate distance determination. Multiple telescope pairs at different relative positions allow tomographic mapping of the ejecta structure while reducing distance uncertainties. As type Ia supernovae serve as standardizable candles for measuring the Universe’s expansion history, combining intensity interferometry distances with the supernova Hubble diagram facilitates measurements of the Hubble constant H0.

cosmological parameters↗

Methodology for Determining Impulse and Quasi-Static Pressure Loading for Design of 6-ft Inner Diameter Confinement Vessel

A brief study of the TNT-equivalence of PBX-9501 is presented herein utilizing a new basis via application of one-dimensional spherical (1DS) hydrocode models in a 6-ft ID confinement vessel geometry with no internal furniture. Specifically, TNT-equivalence herein is based upon two separate features: (1) matching the peak reflected specific impulse of PBX-9501 to TNT under detonation process, and (2) matching quasi-static peak gas pressure of PBX-9501 to TNT at steady-state.

42 ENGINEERING↗

Digital fabrication of a small diameter polymer optical waveguide

A novel polymer optical waveguide and method of manufacturing is presented herein. A digitally manufactured process is described which utilizes a micro-dispensed UV optical adhesive as the contour guiding cladding, a fused deposition modeling technology for creating a core, and a subtractive laser process to finish the two ends of the optical interconnect. The optical waveguide can be printed directly on a circuit board in some embodiments. Alternatively, using a slightly modified process including a step to bond the optical fiber to the substrate, the optical interconnect can be manufactured on a flexible substrate.

Bhethanabotla, Venkat Rama↗

A Novel Method for Preoperative Positioning of Total Ankle Replacement Using 3D Digital Model

Abstract Objective To establish a digital model of the ankle joint through 3D imaging technology and explore the preoperative placement of ankle replacement prostheses. Methods Computed tomography images of intact ankle joints from 54 cases in the outpatient and inpatient departments of our hospital were collected; according to the INBONE® total ankle system surgery process, the surgery model and surgical osteotomy were finished using MIMICS based on computer simulation method. The shortest distance was measured between the center point and the anterior, posterior, medial, and lateral, respectively, to ensure the precise position of the ankle replacement prosthesis by digital simulation surgery. The relationship between the two variables was analyzed by bivariate correlation analysis. Results The dataset of this study included 48 cases of the sub‐data set (26 males and 22 females) and included 27 cases of left ankle and 21 cases of right ankle. The average medial malleolar angle was 18.67°± 2.87°, the average amount of bone resection was 12.13 ± 1.86 cm 3 , the mid‐anterior distance was 1.72 ± 0.19 cm, the mid‐posterior distance was 2.00 ± 0.19 cm, the ratio of mid‐anterior to mid‐posterior was 0.87, the mid‐medial distance was 1.26 ± 0.17 cm, the mid‐lateral distance was 1.19 ± 0.16 cm, and the ratio of mid‐medial to mid‐lateral was 1.06. After osteotomy, the anteroposterior diameter was 3.73 ± 0.32 cm, the transverse diameter was 2.46 ± 0.27 cm, and the ratio of anteroposterior diameter to transverse diameter was 1.53. In the bottom view, the shape after osteotomy is rectangular. The mid‐anterior distance was strongly negatively correlated with age, the mid‐anterior distance and the amount of bone resection, the mid‐medial distance and the amount of bone resection, the mid‐lateral distance and the amount of bone resection, the mid‐lateral distance and the anteroposterior diameter, the anteroposterior diameter and the transverse diameter were all strongly positively correlated. Conclusion The projection point of the lower tibia centerline on the tibial horizontal osteotomy surface is located at a position slightly anterior to the midpoint of the transverse diameter after ankle arthroplasty. The rational positioning of the total ankle replacement is located at both a position slightly anterior to the midpoint of the transverse diameter and midpoint of the anteroposterior diameter, which can be used as a reference method before total ankle arthroplasty surgery.

Wu, Shi‐xun↗

Heat Transfer Coefficients of Additively Manufactured Tubes with Internal Pin Fins for Supercritical Carbon Dioxide Cycle Recuperators

This paper describes the measurement of convective heat transfer coefficients and friction factors for sCO 2 flowing in additively manufactured tubes with internal pin fins at the US DOE’s National Energy Technology Laboratory in Morgantown, WV. The measurement procedures were validated by conducting benchmark tests with smooth stainless-steel tube and comparing the results with published correlations for Nusselt number (Nu) and friction factor. Over Reynolds numbers (ReD) ranging from 5 × 10 4 to 2.5 × 10 5 , measured Nu was within 5% of the Dittus-Boelter correlation and measured friction factors were within 5% of the McAdams correlation for smooth tube flow. The candidate pin fin patterned pipes were additively manufactured (AM) at the Oak Ridge National Laboratory. The pins were circular or elliptical in cross-section and were printed at a 30⁰ angle relative to the inner wall (to meet AM constraints). The pin arrangement was helical to promote enhanced heat transfer due to swirl flow. Pin length to diameter aspect ratio was 1.33, 2, and 8, while the pin diameter to tube diameter ratio was 0.188, 0.125, and 0.063. Tests were performed for ReD varying from 6.9 × 10 4 to 2.2 × 10 5 and at conditions equivalent to the low pressure (LP) outlet (8.69 MPa, 361 K) and the high pressure (HP) inlet (20.7 MPa, 350 K) of the low temperature recuperator (LTR) in an indirect sCO 2 cycle. The Wilson plot technique was utilized to measure the bulk heat transfer coefficients. For the best performing design (tube A, pin length to tube diameter ratio: 1.33, pin diameter to tube diameter ratio: 0.19), the local heat transfer coefficient increased by 136% relative to the Dittus-Boelter correlation at the LTR low pressure outlet and 194% at the LTR high pressure inlet. These correspond to a 282% and a 271% increase in the product of the heat transfer coefficient and surface area (adjusted for fin efficiency) product, respectively. Large pressure drops across the test articles were observed. For Tube Design A, the average friction factor, across the range of ReD considered, was significantly larger than the McAdams correlation at both the LTR LP outlet and the LTR HP inlet. A thermal performance factor was utilized to express the ratio of material required to build a finned heat exchanger relative to a finless heat exchanger with the same heat duty and pumping power. Tube Design A was estimated to decrease the required heat exchanger material by 13%.

Searle, Matthew↗