Search NASA⌕ Search

SEARCH · Search NASA

Results for “diffraction contrast”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Dark field X-ray microscopy below liquid-helium temperature: The case of NaMnO 2

Dark field X-ray microscopy (DFXM) is an experimental technique employed to investigate material properties by probing their ‘mesoscale,’ or microscale structures, in a bulk-sensitive manner using hard X-rays at synchrotron radiation sources. However, challenges remain when it comes to applications of this technique to examine low-temperature phenomena in quantum materials, which exhibit complex phase transitions at cryogenic temperatures. One such material is NaMnO 2 , which hosts an antiferromagnetic transition at 45 K that is suspected to coincide with local structural transitions from its majority monoclinic phase to nanoscale triclinic domains. Direct observation of local heterogeneities and this effect at low temperatures in NaMnO 2 is an important step in understanding this material and serves as an ideal candidate study for expanding the DFXM experimental design space. This paper details a foundational high-resolution DFXM study, down to liquid-helium temperature and below, conducted to explore phase transitions in NaMnO 2 . In conclusion, the outlined experiment ushers in the evaluation of other functional materials at low temperatures using this technique.

36 MATERIALS SCIENCE↗

Denticity and Mobility of the Carbonate Groups in AMCO 3 F Fluorocarbonates: A Study on KMnCO 3 F and High Temperature KCaCO 3 F Polymorph

We report on a thorough structural study on two members of layered fluorocarbonates KMCO 3 F (M = Ca, Mn). The Ca-based member demonstrates a phase transition at ~320 °C, evidenced for the first time. The crystal structure of the high temperature phase (HT-KCaCO 3 F) was solved using neutron powder diffraction. A new Mn-based phase KMnCO 3 F was synthesized, and its crystal structure was solved from electron diffraction tomography data and refined from a combination of X-ray synchrotron and neutron powder diffraction. In contrast to other members of the fluorocarbonate family, the carbonate groups in the KMnCO 3 F and HT-KCaCO 3 F structures are not fixed to two distinct orientations corresponding to mono- and bidentate coordinations of the M cation. In KMnCO 3 F, the carbonate group can be considered as nearly “monodentate”, forming one short (2.14 Å) and one long (3.01 Å) Mn–O contact. This topology provides more flexibility to the MCO 3 layer and enables diminishing the mismatch between the MCO 3 and KF layers. This conclusion is corroborated by the HT-KCaCO 3 F structure, in which the carbonate groups can additionally be tilted away from the layer plane thus relieving the strain arising from geometrical mismatch between the layers. The correlation between denticity of the carbonate groups, their mobility, and cation size variance is discussed. KMnCO 3 orders antiferromagnetically below T N = 40 K.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Precision-controlled ultrafast electron microscope platforms. A case study: Multiple-order coherent phonon dynamics in 1T-TaSe2 probed at 50 fs–10 fm scales

We report on the first detailed beam tests attesting the fundamental principle behind the development of high-current-efficiency ultrafast electron microscope systems where a radio frequency (RF) cavity is incorporated as a condenser lens in the beam delivery system. To allow for the experiment to be carried out with a sufficient resolution to probe the performance at the emittance floor, a new cascade loop RF controller system is developed to reduce the RF noise floor. Temporal resolution at 50 fs in full-width-at-half-maximum and detection sensitivity better than 1% are demonstrated on exfoliated 1T-TaSe2 system under a moderate repetition rate. To benchmark the performance, multi-terahertz edge-mode coherent phonon excitation is employed as the standard candle. The high temporal resolution and the significant visibility to very low dynamical contrast in diffraction signals via high-precision phase-space manipulation give strong support to the working principle for the new high-brightness femtosecond electron microscope systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of High-Performance Ni-base Alloys for Gas Turbine Wheels Using a Coprecipitation Approach (Final Technical Report)

In this project, a synergistic approach involving experiments informed by modelling was used to develop γ'/γ'' coprecipitation-strengthened Ni-base superalloys for land-based gas turbine wheels. In thick sections of such turbine wheels, the slow cooling rate normally observed, as well as variations in cooling rate could potentially result in drastically inhomogeneous and coarsened microstructure. Thus, ten alloy compositions were selected based on coprecipitation and sluggish γ’ growth and coarsening during three iterations of alloy development, assisted by extensive CALPHAD modeling. Phase equilibrium calculations, informed by the characterization of early alloys, were successful in predicting suitable aging treatments to obtain bimodal coprecipitate distribution in several alloys. These aging treatments were applied to the subsequent round of alloys and the resulting microstructures were characterized in detail. Two different cooling rates were used during each of these heat treatments to simulate the range of cooling rates observed in a thick section forging. The microstructures were used to calibrate a multi-phase field model (MPF), which was used to study the formation mechanisms of various coprecipitate morphologies observed in the experiments. Following this, the most promising alloys in each round were selected and studied using high temperature tensile and creep tests. Considering that a slower cooling rate would lead to a strength debit, while a faster cooling rate might lead to a decline in creep rupture life of a full-scale wheel, tensile tests were carried out for slower cooled samples, while creep tests were carried out for faster cooled samples. The deformation microstructures were then characterized using advanced characterization techniques such as Diffraction Contrast-Scanning Transmission Electron Microscopy (DC-STEM) and Electron Channeling Contrast Imaging (ECCI). Further, a mean-field creep model was developed and calibrated using these experimental findings to predict long-term creep behavior of these coprecipitation-strengthened alloys.

36 MATERIALS SCIENCE↗

Comparison of dislocation characterization by electron channeling contrast imaging and cross-correlation electron backscattered diffraction

In this paper, the relative capabilities and limitations of electron channeling contrast imaging (ECCI) and cross-correlation electron backscattered diffraction (CC-EBSD) have been assessed by studying the dislocation distributions resulting from nanoindentation in body centered cubic Ta. Qualitative comparison reveals very similar dislocation distributions between the CC-EBSD mapped GNDs and the ECC imaged dislocations. Approximate dislocation densities determined from ECC images compare well to those determined by CC-EBSD. Nevertheless, close examination reveals subtle differences in the details of the distributions mapped by these two approaches. Finally, the details of the dislocation Burgers vectors and line directions determined by ECCI have been compared to those determined using CC-EBSD and reveal good agreement.

36 MATERIALS SCIENCE↗

X-ray Diffraction and Multi-Frame Phase Contrast Imaging Diagnostics for IMPULSE at the Advanced Photon Source

The diagnostic needs of any dynamic loading platform present unique technical challenges that must be addressed in order to accurately measure in situ material properties in an extreme environment. The IMPULSE platform (IMPact system for Ultrafast Synchrotron Experiments) at the Advanced Photon Source (APS) is no exception and, in fact, may be more challenging, as the imaging diagnostics must be synchronized to both the experiment and the 60 ps wide x-ray bunches produced at APS. The technical challenges of time-resolved x-ray diffraction imaging and high-resolution multi-frame phase contrast imaging (PCI) are described in this paper. Example data from recent IMPULSE experiments are shown to illustrate the advances and evolution of these diagnostics with a focus on comparing the performance of two intensified CCD cameras and their suitability for multi-frame PCI. The continued development of these diagnostics is fundamentally important to IMPULSE and many other loading platforms and will benefit future facilities such as the Dynamic Compression Sector at APS and MaRIE at Los Alamos National Laboratory.

IMPULSE, x-ray, diffraction, PCI, imaging↗

Simultaneous 8.2 keV phase-contrast imaging and 24.6 keV X-ray diffraction from shock-compressed matter at the LCLS

In this paper, we demonstrate simultaneous phase-contrast imaging (PCI) and X-ray diffraction from shock compressed matter at the Matter in Extreme Conditions endstation, at the Linac Coherent Light Source (LCLS). We utilize the chromaticity from compound refractive X-ray lenses to focus the 24.6 keV 3rd order undulator harmonic of the LCLS to a spot size of 5 μm on target to perform X-ray diffraction. Simultaneous PCI from the 8.2 keV fundamental X-ray beam is used to visualize and measure the transient properties of the shock wave over a 500 μm field of view. Furthermore, we demonstrate the ability to extend the reciprocal space measurements by 5 Å –1 , relative to the fundamental X-ray energy, by utilizing X-ray diffraction from the 3rd harmonic of the LCLS.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Phase-Contrast Imaging of Nanostructures with Incoherent Femtosecond Laser Driven Soft X-Ray Source

Application of polychromatic (1.5-15 nm) soft X-ray emission of a spatially large (>0.1 mm) bright femtosecond laser driven plasma source for propagation based phase contrast imaging of nanometer thick foils and biological samples is considered. Diffraction and phase contrast effects increased quality and contrast of the experimental images, registered by LiF crystal X-ray detector with submicron resolution.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Hybrid quantitative simulation on the in-line phase-contrast x-ray imaging of three dimensional samples under actual clinic imaging parameters

A hybrid model combining Monte Carlo method with diffraction theory of wave optics has been developed and applied to quantitatively simulate the in-line diffractive phase-contrast x-ray imaging of three dimensional tissue samples under actual clinic imaging parameters. The primary microcosmic interactions of medical-energy x-ray within matter including photoabsorption, Compton scattering, and coherent scattering, have been taken into account in the Monte Carlo simulation. A diffraction processing based on Fresnel diffraction theory is carried out to simulate the macroscopic diffraction effect. A comparison with experiment results has also been performed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Whole-cell phase contrast imaging at the nanoscale using Fresnel Coherent Diffractive Imaging Tomography

X-ray tomography can provide structural information of whole cells in close to their native state. Radiation-induced damage, however, imposes a practical limit to image resolution, and as such, a choice between damage, image contrast, and image resolution must be made. New coherent diffractive imaging techniques, such Fresnel Coherent Diffractive Imaging (FCDI), allows quantitative phase information with exceptional dose efficiency, high contrast, and nano-scale resolution. Here we present three-dimensional quantitative images of a whole eukaryotic cell by FCDI at a spatial resolution below 70 nm with sufficient phase contrast to distinguish major cellular components. From our data, we estimate that the minimum dose required for a similar resolution is close to that predicted by the Rose criterion, considerably below accepted estimates of the maximum dose a frozen-hydrated cell can tolerate. Based on the dose efficiency, contrast, and resolution achieved, we expect this technique will find immediate applications in tomographic cellular characterisation.

MICROSCOPY↗

Phase retrieval by coherent modulation imaging

Phase retrieval is a long-standing problem in imaging when only the intensity of the wavefield can be recorded. Coherent diffraction imaging (CDI) is a lensless technique that uses iterative algorithms to recover amplitude and phase contrast images from diffraction intensity data. For general samples, phase retrieval from a single diffraction pattern has been an algorithmic and experimental challenge. Here we report a method of phase retrieval that uses a known modulation of the sample exit-wave. This coherent modulation imaging (CMI) method removes inherent ambiguities of CDI and uses a reliable, rapidly converging iterative algorithm involving three planes. It works for extended samples, does not require tight support for convergence, and relaxes dynamic range requirements on the detector. CMI provides a robust method for imaging in materials and biological science, while its single-shot capability will benefit the investigation of dynamical processes with pulsed sources, such as X-ray free electron laser.

36 MATERIALS SCIENCE↗

The importance of temporal and spatial incoherence in quantitative interpretation of 4D-STEM

Recent developments in pixelated detectors, when combined with aberration correction of probe forming optics have greatly enhanced the field of scanning electron diffraction. Differential phase contrast is now routine and deep learning has been proposed as a method to extract maximum information from diffraction patterns. This study examines the effects of temporal and spatial incoherence on convergent beam electron diffraction patterns and demonstrates that simple center of mass measurements cannot be naively interpreted. The inclusion of incoherence in deep learning data sets is also discussed.

36 MATERIALS SCIENCE↗

Quantitative measurement of phase variation amplitude of ultrasonic diffraction grating based on diffraction spectral analysis

A new method based on diffraction spectral analysis is proposed for the quantitative measurement of the phase variation amplitude of an ultrasonic diffraction grating. For a traveling wave, the phase variation amplitude of the grating depends on the intensity of the zeroth- and first-order diffraction waves. By contrast, for a standing wave, this amplitude depends on the intensity of the zeroth-, first-, and second-order diffraction waves. The proposed method is verified experimentally. The measured phase variation amplitude ranges from 0 to 2π, with a relative error of approximately 5%. A nearly linear relation exists between the phase variation amplitude and driving voltage. Our proposed method can also be applied to ordinary sinusoidal phase grating.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison of Dislocation Characterization by Electron Channeling Contrast Imaging and Cross-Correlation Electron Backscattered Diffraction

The characterization and quantification of dislocations is predominately carried out using transmission electron microscopy (TEM). Nevertheless, the sample preparation necessary for TEM foils can be cumbersome and possibly introduce defects. Two other techniques for characterizing and quantifying dislocations are electron channeling contrast imaging (ECCI) and cross-correlation electron backscattered diffraction (CC-EBSD). ECCI is similar to TEM in that specific imaging (channeling or diffraction) conditions need to be established, but is carried out in a scanning electron microscope on bulk samples, resulting in less complex sample preparation. CC-EBSD measures subtle changes in orientation measured from EBSD patterns to calculate elastic strains and the Nye tensor to deduce and map the total geometrically necessary dislocation (GND) content. Furthermore, this work presented here compares the capabilities of ECCI and CC-EBSD to map dislocations generated from nanoindentation.

42 ENGINEERING↗

Optimization of Crystals of an Inhibitory Antibody of Urokinase Plasminogen Activator Receptor (uPAR) with Hydrogen Peroxide and Low Protein Concentration

Optimization of protein crystal formation is often a necessary step leading to diffraction-quality crystals to enable collection of a full X-ray data set. Typical protein crystal optimization involves screening different components, e.g., pH, precipitants, and additives of the precipitant solution. Here we present an example using an inhibitory antibody of urokinase plasminogen activator receptor (uPAR) where such procedures did not yield diffracting crystals. In contrast, it was the treatment of the protein with hydrogen peroxide incubation and the protein concentration reduction that were found to be key factors in obtaining diffracting crystals. Final crystals diffracted to 1.75 {angstrom}, and belong to orthorhombic P212121 space group with unit cell parameters a = 37.162 {angstrom}, b = 84.474 {angstrom}, c = 134.030 {angstrom}, and contain one molecule of Fab fragment of anti-uro kinase receptor antibody in the asymmetric unit.

59 BASIC BIOLOGICAL SCIENCES↗

In-situ X-ray observations of ultrasound-induced explosive decomposition

High-strain mechanical loading of polymer-bonded explosives can produce significant stress concentrations due to microstructural heterogeneities, resulting in localized thermal “hot spots”. Ultrasound produces similar effects and has been proposed as a tool to study the thermomechanical interactions related to explosive initiation. Detailed observations of the processes governing the generation of heat in these materials are severely lacking, yet they are vital for identifying salient physics, improving the modeling tools used to predict mechanical response, improving explosives safety, and providing insight into the initiation mechanisms of explosion. Here we discuss high-speed, high-resolution in-situ observations, obtained via synchrotron X-ray phase contrast imaging and diffraction, of the heating and decomposition of an explosive material under ultrasonic excitation. We demonstrate that interfacial friction is a dominant heating mechanism and can yield violent reaction of explosive particles. Moreover, sub-surface particle temperatures are estimated via diffraction.

36 MATERIALS SCIENCE↗