Search NASA⌕ Search

SEARCH · Search NASA

Results for “digital data acquisition”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

VLSI-based Video Event Triggering for Image Data Compression

Long-duration, on-orbit microgravity experiments require a combination of high resolution and high frame rate video data acquisition. The digitized high-rate video stream presents a difficult data storage problem. Data produced at rates of several hundred million bytes per second may require a total mission video data storage requirement exceeding one terabyte. A NASA-designed, VLSI-based, highly parallel digital state machine generates a digital trigger signal at the onset of a video event. High capacity random access memory storage coupled with newly available fuzzy logic devices permits the monitoring of a video image stream for long term (DC-like) or short term (AC-like) changes caused by spatial translation, dilation, appearance, disappearance, or color change in a video object. Pre-trigger and post-trigger storage techniques are then adaptable to archiving only the significant video images.

Williams, Glenn L.↗

Advanced Data Management for the Wastewater Industry

This information sheet discusses the technology pillar Advanced Data Management as a pathway toward improving wastewater infrastructure sustainability and resiliency. To supplement existing literature on current technologies and policies for improving resiliency at wastewater treatment plants (WWTPs), this document aims to accomplish the following: • Summarize key technologies such as Supervisory Control and Data Acquisition (SCADA), digital twins, and smart sensors • Summarize relevant cybersecurity measures and data management tools available for WW utilities • Summarize advances in sensing and monitoring technologies • Serve as a comprehensive (though not exhaustive) repository for data management for wastewater utilities The Advanced Management Technical Information Sheet should be viewed as a general guide to established best practices for the water and wastewater sector when considering implementing energy capture and energy- or process-efficient technologies. Further details are presented in the SWIFt Technology Information Sheet Series for accompanying Technology Pillars.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Gas Flow Detection System

This system provides a portable means to detect gas flow through a thin-walled tube without breaking into the tubing system. The flow detection system was specifically designed to detect flow through two parallel branches of a manifold with only one inlet and outlet, and is a means for verifying a space shuttle program requirement that saves time and reduces the risk of flight hardware damage compared to the current means of requirement verification. The prototype Purge Vent and Drain Window Cavity Conditioning System (PVD WCCS) Flow Detection System consists of a heater and a temperature-sensing thermistor attached to a piece of Velcro to be attached to each branch of a WCCS manifold for the duration of the requirement verification test. The heaters and thermistors are connected to a shielded cable and then to an electronics enclosure, which contains the power supplies, relays, and circuit board to provide power, signal conditioning, and control. The electronics enclosure is then connected to a commercial data acquisition box to provide analog to digital conversion as well as digital control. This data acquisition box is then connected to a commercial laptop running a custom application created using National Instruments LabVIEW. The operation of the PVD WCCS Flow Detection System consists of first attaching a heater/thermistor assembly to each of the two branches of one manifold while there is no flow through the manifold. Next, the software application running on the laptop is used to turn on the heaters and to monitor the manifold branch temperatures. When the system has reached thermal equilibrium, the software application s graphical user interface (GUI) will indicate that the branch temperatures are stable. The operator can then physically open the flow control valve to initiate the test flow of gaseous nitrogen (GN2) through the manifold. Next, the software user interface will be monitored for stable temperature indications when the system is again at thermal equilibrium with the test flow of GN2. The temperature drop of each branch from its "no flow" stable temperature peak to its stable "with flow" temperature will allow the operator to determine whether a minimum level of flow exists. An alternative operation has the operator turning on the software only long enough to record the ambient temperature of the tubing before turning on the heaters and initiating GN2 flow. The stable temperature of the heated tubing with GN2 flow is then compared with the ambient tubing temperature to determine if flow is present in each branch. To help quantify the level of flow in the manifolds, each branch will be bench calibrated to establish its thermal properties using the flow detection system and different flow rates. These calibration values can then be incorporated into the software application to provide more detailed flow rate information.

Moss, Thomas↗

Experimental Investigation of Jet Impingement Heat Transfer Using Thermochromic Liquid Crystals

Jet impingement cooling of a hypersonic airfoil leading edge is experimentally investigated using thermochromic liquid crystals (TLCS) to measure surface temperature. The experiment uses computer data acquisition with digital imaging of the TLCs to determine heat transfer coefficients during a transient experiment. The data reduction relies on analysis of a coupled transient conduction - convection heat transfer problem that characterizes the experiment. The recovery temperature of the jet is accounted for by running two experiments with different heating rates, thereby generating a second equation that is used to solve for the recovery temperature. The resulting solution requires a complicated numerical iteration that is handled by a computer. Because the computational data reduction method is complex, special attention is paid to error assessment. The error analysis considers random and systematic errors generated by the instrumentation along with errors generated by the approximate nature of the numerical methods. Results of the error analysis show that the experimentally determined heat transfer coefficients are accurate to within 15%. The error analysis also shows that the recovery temperature data may be in error by more than 50%. The results show that the recovery temperature data is only reliable when the recovery temperature of the jet is greater than 5 C, i.e. the jet velocity is in excess of 100 m/s. Parameters that were investigated include nozzle width, distance from the nozzle exit to the airfoil surface, and jet velocity. Heat transfer data is presented in graphical and tabular forms. An engineering analysis of hypersonic airfoil leading edge cooling is performed using the results from these experiments. Several suggestions for the improvement of the experimental technique are discussed.

Dempsey, Brian Paul↗

Enhanced Data-Acquisition System

Time-consuming, costly digitization of analog signals on magnetic tape eliminated. Proposed data-acquisition system provides nearly immediate access to data in incoming signals by digitizing and recording them both on magnetic tape and on optical disk. Tape and/or disk later played back to reconstruct signals in analog or digital form for analysis. Of interest in industrial and scientific applications in which necessary to digitize, store, and/or process large quantities of experimental data.

Mustain, Roy W.↗

Infrared astronomical imaging using a microcomputer data system

A small, portable data-acquisition and display system with a unique coprocessor was designed and built to collect data from infrared array detectors for astronomical and laboratory use. The system consists of a microcomputer board, two 12-bit analog-to-digital data-acquisition boards, a color-graphics driver board, and two coprocessor boards. The coprocessors are arithmetic logic units designed to achieve the high computation rates necessary for real-time infrared background cancellation. The system can collect data from infrared detectors of 1 to 256 pixel elements with a computation rate of 768 kHz. The software for the system was designed to collect data in the system's background, while performing other tasks in the system's foreground. The data for the detector arrays is stored in block fashion to facilitate variable image size.

Stafford, P. S.↗

Improving Signal to Noise Ratios in Ion Mobility Spectrometry and Structures for Lossless Ion Manipulations (SLIM) using a High Dynamic Range Analog-to-Digital Converter

Signal digitization is a commonly overlooked part of ion mobility-mass spectrometry (IMS-MS) workflows, yet it is a significant contributor for determining signal-to-noise ratios and MS resolution. Here we report on the integration of a 2 GS/s, 14-bit ADC with a structures for lossless ion manipulations (SLIM)-IMS-MS and compare the performance to a commonly used 8-bit ADC. The 14-bit ADC provided an effective reduction in digitized noise by factor of ~6, owing largely to the use of smaller bit sizes. The low baseline allowed the threshold voltage levels to be set very close to the MCP baseline voltage, allowing for as much signal to be acquired as possible without causing overloading or excessive digitization of MCP baseline noise. Analyses of Agilent tuning mixture ions and a complex mixture of heavy labeled phosphopeptides showed that the 14-bit ADC (compared to the 8-bit ADC) provided a modest signal-to-noise increase (~1.5 to 2-fold) for high intensity ions, such as the Agilent tuning mixture ions and the 2+ and 3+ charge states of many phosphopeptide constituents. However, signal enhancements were as much as 10-fold for low intensity ions, and the 14-bit ADC enabled discernable signal intensities otherwise lost using an 8-bit digitizer. Additionally, the 14-bit ADC required ~14-fold fewer mass spectra to be averaged to produce a mass spectrum with similar S/N as the 8-bit ADC under identical conditions, potentially providing an order of magnitude higher measurement throughput. The high resolution, low baseline, and fast speed of the new 14-bit ADC enables high performance digitization of MS, IMS-MS, and SLIM-IMS-MS spectra, and allows a much fuller picture of analyte profiles in complex mixtures to be acquired.

data acquisition, digitization, ion mobility spect↗

Overview and first measurements of the MAST Upgrade bolometer diagnostic

Here, a suite of multi-channel resistive bolometers has been implemented to measure the total radiation from Mega Amp Spherical Tokamak Upgrade plasmas, with cameras covering the core plasma and lower divertor chamber. Data are digitized and processed using novel field-programmable gate array-based electronics, offering improved compactness and new operational capabilities. A synthetic diagnostic has been developed to explore the quality of 2D reconstructions available from the system and to quantify the uncertainty on quantities such as the total radiated power. Measurements in the first campaign have demonstrated correct functioning of the diagnostic while also highlighting issues with electrical noise and some failure mechanisms of the detectors, as well as significant neutral beam fast-particle losses.

47 OTHER INSTRUMENTATION↗

The impact of detection rate changes and correlations on random-coincidence background measurements

Coincidence detection of multiple particles emitted during an experiment can yield a new depth of understanding of the underlying process under study. However, the probability of detecting particles that are generated from the same physical event within a given coincidence time window is generally much lower than that of detecting particles that appear in the same coincidence time window, but were not created from the same physical event, and are therefore detected randomly in coincidence with each other. Thus, accurate and precise methods of measuring this random-coincidence background are essential for a wide variety of fields of science. A method to determine this background directly using the data themselves without any additional experimental run time or fake signals introduced in the data was recently established (O’Donnell, 2016). This method yields a statistical uncertainty on the random-coincidence background that is orders of magnitude smaller than that of the true coincidence data, though the potential for systematic errors of backgrounds from this method was never explored. In this work, we discuss common varieties of correlated and uncorrelated changes in the detection rates of each particle detected in an experiment. Here we demonstrate here that a correlation between particle detection rates from, for example, an incident particle beam that initiates a physical process of interest, creates systematic errors in the random-coincidence background measurement. We also discuss the impact of a variety of other realistic scenarios for rate changes in experiments. Lastly, a method is introduced to correct for errors in the random-coincidence background from any source, yielding an optimization between statistical precision and eliminating potential lingering systematic errors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Digital events evaluator

Real time digital event evaluator description for Saturn launch vehicle checkout

SATURN LAUNCH VEHICLE↗

Use of the single-breath method of estimating cardiac output during exercise-stress testing.

The single-breath cardiac output measurement technique of Kim et al. (1966) has been modified for use in obtaining cardiac output measurements during exercise-stress tests on Apollo astronauts. The modifications involve the use of a respiratory mass spectrometer for data acquisition and a digital computer program for data analysis. The variation of the modified method for triplicate steady-state cardiac output measurements was plus or minus 1 liter/min. The combined physiological and methodological variation seen during a set of three exercise tests on a series of subjects was 1 to 2.5 liter/min. Comparison of the modified method with the direct Fick technique showed that although the single-breath values were consistently low, the scatter of data was small and the correlation between the two methods was high. Possible reasons for the low single-breath cardiac output values are discussed.

Buderer, M. C.↗

Directional velocity analyzer for measuring electron distribution functions in plasmas

A directional velocity analyzer has been developed for measuring electron distribution functions in plasmas. It contains a collimating aperture which selects particles from a narrow cone in velocity space and a retarding potential analyzer. The distribution function f(v, theta, phi) is obtained from a large number of analyzer traces taken at different angles theta, phi. In addition, the small analyzer can be moved in space and the measurements are time resolved so as to obtain the complete phase space information f(v,r,t). The large data flow of this seven-variable function is processed with a high-speed digital data-acquisition system. The new electron velocity analyzer is applicable over a wide parameter range in electron energies and densities. Various cases of anisotropic distributions such as beams, shells, tails, and drifts have been successfully investigated.

Stenzel, R. L.↗

A computerized aircraft battery servicing facility

The latest upgrade to the Aerospace Energy Systems Laboratory (AESL) is described. The AESL is a distributed digital system consisting of a central system and battery servicing stations connected by a high-speed serial data bus. The entire system is located in two adjoining rooms; the bus length is approximately 100 ft. Each battery station contains a digital processor, data acquisition, floppy diskette data storage, and operator interfaces. The operator initiates a servicing task and thereafter the battery station monitors the progress of the task and terminates it at the appropriate time. The central system provides data archives, manages the data bus, and provides a timeshare interface for multiple users. The system also hosts software production tools for the battery stations and the central system.

Glover, Richard D.↗

Earth Observing-1 Advanced Land Imager: Imaging Performance On-Orbit

This report analyzes the on-orbit imaging performance of the Advanced Land Imager (ALI) on the Earth Observing-1 satellite. The pre-flight calibrations are first summarized. The methods used to reconstruct and geometrically correct the image data from this push-broom sensor are described. The method used here does not refer to the position and attitude telemetry from the spacecraft. Rather, it is assumed that the image of the scene moves across the focal plane with a constant velocity, which can be ascertained from the image data itself. Next, an assortment of the images so reconstructed is presented. Color images sharpened with the 10-m panchromatic band data are shown, and the algorithm for producing them from the 30-m multispectral data is described. The approach taken for assessing spatial resolution is to compare the sharpness of features in the on-orbit image data with profiles predicted on the basis of the pre-flight calibrations. A large assortment of bridge profiles is analyzed, and very good fits to the predicted shapes are obtained. Lunar calibration scans are analyzed to examine the sharpness of the edge-spread function at the limb of the moon. The darkness of the space beyond the limb is better for this purpose than anything that could be simulated on the ground. From these scans, we find clear evidence of scattering in the optical system, as well as some weak ghost images. Scans of planets and stars are also analyzed. Stars are useful point sources of light at all wavelengths, and delineate the point-spread functions of the system. From a quarter-speed scan over the Pleiades, we find that the ALI can detect 6th magnitude stars. The quality of the reconstructed images verifies the capability of the ALI to produce Landsat-type multi spectral data. The signal-to-noise and panchromatic spatial resolution are considerably superior to those of the existing Landsat sensors. The spatial resolution is confirmed to be as good as it was designed to be.

ALI (ADVANCED LAND IMAGER)↗

Statistics of the charge spectrum of photo-multipliers and methods for absolute calibration

We derive the full expression for the shape of the charge spectrum that results from the illumination of a photo-multiplier tube. The derivation is for low intensity illumination with constant gain, a common condition for most nuclear and particle physics applications. Under these conditions, it is shown that an analytic expression can be formulated that describes details of the spectrum including the pedestal and dark noise with excellent fidelity to allow statistical fits to data. The derivation and full formula using either Gaussian or Poisson models for gain, and its limiting forms under various simplifying assumptions are presented with strategies on their use. The analytic description can be used to formulate data acquisition strategies to perform precise absolute calibration of photo-multipliers, the digitizers, and the data acquisition system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗