Search NASA⌕ Search

SEARCH · Search NASA

Results for “digital pulse processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

High repetition rate neutron flux array using digital-signal processing and scintillators for study of high performance plasma at JT-60U

Aiming at increasing the count rate capability of the radial neutron collimator system in JT-60U, a digital-signal processing system has been extended to seven channels for data acquisition of stilbene crystal detector using analog-to-digital converters equipped with a fast flash memory. In this method, the detected pulses were postprocessed concerning pulse shape and pulse height. Using this system, the radial neutron collimator system can provide the information on the temporal evolution of emission rate of d-T neutrons and gamma rays as well as d-D neutrons. On the course of the development, the fast and stable handling of the large data around 7 GB is undertaken for a discharge.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Application of a digital pileup resolving method to high count rate neutron measurements

The possibility of working in high count rate conditions is an important issue for neutron measurements applied to fusion experiments in order to extend the measurement dynamic range and time resolution. One of the main issues of high count rate operation is the overlapping of closely spaced events (pileup) that produces a distortion in their amplitude and therefore in the pulse height spectra. The usual way to deal with such pileup events using standard analog electronics is to reject them in the energy analysis process. Thanks to digital acquisition techniques, the waveforms of pileup events can be recorded and elaborated in order to reconstruct the contributing original single events. This work presents the results of the application of a pileup resolving method for the reconstruction and analysis of overlapping events to pulses acquired digitally from a NE213 liquid scintillator detector. The measurements have been carried out at the PTB accelerator facility with 14 MeV neutrons at total count rates over 400 kHz.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A New Method of Prompt Fission Neutron Energy Spectrum Unfolding

The prompt neutron emission in spontaneous fission of {sup 252}Cf has been investigated applying digital signal electronics along with associated digital signal processing algorithms. The goal was to find out the reasons of a long time existing discrepancy between theoretical calculations and the measurements of prompt fission neutron (PFN) emission dependence on the total kinetic energy (TKE) of fission fragments (FF). On the one hand the {sup 252}Cf(sf) reaction is one of the main references for nuclear data, on the other hand the understanding of PFN emission mechanism is very important for nuclear fission theory. Using a twin Frisch-grid ionization chamber for fission fragment (FF) detection and a NE213-equivalent neutron detector in total about 10{sup 7} fission fragment-neutron coincidences have been registered. Fission fragment kinetic energy, mass and angular distribution, neutron time-of-flight and pulse shape have been investigated using a 12 bit waveform digitizer. The signal waveforms have been analyzed using digital signal processing algorithms. For the first time the dependence of the number of emitted neutrons as a function of total kinetic energy (TKE) of the fragments is in very good agreement with theoretical calculations in the range of TKE from 140-220 MeV.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of Fission Neutron Spectrum and Multiplicity using a Gamma Tag Double Time-of-flight Setup

Recent efforts have been made to improve the prompt fission neutron spectrum and nu-bar measurements for Uranium and Plutonium isotopes particularly in the keV region. A system has been designed at Rensselaer Polytechnic Institute (RPI) utilizing an array of EJ-301 liquid scintillators as well as lithium glass and plastic scintillators to experimentally determine these values. An array of BaF2 detectors was recently obtained from Oak Ridge National Laboratory to be used in conjunction with the neutron detectors. The system uses a novel gamma tagging method for fission which can offer an improvement over conventional fission chambers due to increased sample mass. A coincidence requirement on the gamma detectors from prompt fission gammas is used as the fission tag for the system as opposed to fission fragments in a conventional fission chamber. The system utilizes pulse digitization using Acqiris 8 bit digitizer boards which allow for gamma/neutron pulse height discrimination on the liquid scintillators during post processing. Additionally, a 252Cf fission chamber was designed and constructed at RPI which allowed for optimization and testing of the system without the need for an external neutron source. The characteristics of the gamma tagging method such as false detection rate and detection efficiency were determined using this fission chamber and verified using MCNP Polimi modeling. Prompt fission neutron spectrum data has been taken using the fission chamber focusing on the minimum detectable neutron energy for each of the various detectors. Plastic scintillators were found to offer a significant improvement over traditional liquid scintillators allowing energy measurements down to 50 keV. Background was also characterized for all detectors and will be discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Acoustic camera

Apparatus for generating accurate 3-dimensional images of objects immersed in liquids including optically opaque liquids which may also have significant sound attenuation, is described. Sound pulses are caused to impinge on the object, and the time-of-flight of the reflected sound is used to create a 3-dimensional image of the object in almost real-time. The apparatus is capable of creating images of objects immersed in fluids that are optically opaque and have high sound attenuation at resolutions less than about 1 mm. The apparatus may include a piezoelectric transducer for generating the acoustic pulses; a high-density polyethylene compound acoustic lens, a 2-dimensional segmented piezoelectric detecting array positioned behind the lens for receiving acoustic pulses reflected by the object, the electric output of which is directed to digital signal processing electronics for generating the image.

47 OTHER INSTRUMENTATION↗

Digitalized two parametric system for gamma/neutron spectrometry - Paper 59

Many types of detectors like stilbene, NE-213 etc. in conjunction with photomultiplier loaded with low working resistance produce pulses of approximately 100 ns length and contain information about deposited particle in the trailing edge. Using fast analog to digital converters (ADC) and field-programmable gate array (FPGA) it is possible to create a spectrometric system working in mixed gamma and neutron fields which is not loaded dead time. The count rate of processed pulses can reach more than one million per second. Such a high count rate of processed pulses can be achieved due to the pulse processing is implemented in FPGA. The output of this pulse processing is amplitude which describes the energy of deposited particle and discrimination parameter whereby it is possible to discriminate photons and neutrons. To increase the dynamic range of energy of detectable particle the signal from photomultiplier is separated into two branches with different amplification. Each branch is digitalized by separate ADC. Components from which the system is composed are so light that the spectrometer can be easily transported. Its weight is less than 3 kilograms. Spectrometer was tested in the research reactor LR-0 in Rez near Prague (Czech Republic). The measured data was processed using deconvolution into a neutron flux density and compared with nowadays used analog spectrometer and simulation result. Measured neutron spectrum of Cf-252 is included. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Predicted performance of a tangential viewing hard x-ray camera for the DIII-D high field side lower hybrid current drive experiment

High field side launch of lower hybrid current drive (LHCD) has improved accessibility and penetration over low field side launch on DIII-D. Simulations predict single pass absorption under a wide range of plasma conditions. Hard x-ray (HXR) measurement of LHCD generated fast electron bremsstrahlung (50–250 keV) will validate wave propagation and absorption. Emissivity profiles are recovered from one-dimensional inversion of HXR brightness to determine LH damping location, fast electron slowing down time, and some indication of the fast electron energy. The camera will be implemented by populating 32 tangential sightlines of the existing Gamma Ray Imager with Kromek SPEARTM Cadmium Zinc Telluride (CZT) detectors sensitive to 10–1000 keV photons with 10 keV energy resolution. Expected count rates allow for <0.5 ms time resolution. Pulses are processed using 50 ns shaping time Cremat CR-200 Gaussian shaping modules and are digitized by 25 MHz D-TACQ ACQ216 digitizers. The performance of the HXR camera is evaluated by comparing predicted fast electron density profiles and inverted synthetic brightnesses obtained from the ray-tracing/Fokker–Planck codes GENRAY/CQL3D. Inversions closely matched predicted fast electron profiles for a range of experimental parameters.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

X-ray multi-probe data acquisition: A novel technique for laser pump x-ray transient absorption spectroscopy

We report the development and implementation of a novel data acquisition (DAQ) technique for synchrotron-based laser pump X-ray Transient Absorption (XTA) spectroscopy, called X-ray Multi-Probe DAQ (XMP DAQ). This technique utilizes high performance analog to digital converters and home-built software to efficiently measure and process the XTA signal from all x-ray pulses between laser excitations. XMP DAQ generates a set of time resolved x-ray absorption spectra at thousands of different pump–probe time delays simultaneously. Two distinct XMP DAQ schemes are deployed to accommodate different synchrotron storage ring filling patterns. Current Integration (CI) DAQ is a quasi-analog technique that implements a fitting procedure to extract the time resolved absorption intensity from the averaged fluorescence detector response. The fitting procedure eliminates issues associated with small drifts in the voltage baseline and greatly enhances the accuracy of the technique. Photon Counting (PC) DAQ is a binary technique that uses a time resolved histogram to calculate the XTA spectrum. While PC DAQ is suited to measure XTA data with closely spaced x-ray pulses (~10 ns) and a low count rate (<1 detected photon/pulse), CI DAQ works best for widely spaced pulses (tens of ns or greater) with a high count rate (>1 detected photon/pulse). XMP DAQ produces a two-dimensional XTA dataset, enabling efficient quantitative analysis of photophysical and photochemical processes from the sub-nanosecond timescale to 100 μs and longer.

47 OTHER INSTRUMENTATION↗

High Sensitivity Readout and Data Processing for Environmental Spectral Radiation Measurements

We have developed a new version of high sensitivity electronics front end and analog signal processing for use with high pressure ionization chambers in environmental radiation measurements. The readout circuit provides low noise signal readout from individual events of gas ionization. Readout electronics is connected to the analog-to?digital converter providing continuous high rate data sampling. The data processing algorithm allows noise rejection and extraction of pulse shape and amplitude information related to the ionization loss in the gas for each ionization event. The output of the detector could be presented in a traditional way as the accumulated ionization charge per unit time, and as a signal amplitude spectroscopic distribution. Results of the initial evaluation are presented. These results were obtained using the designed electronics connected to the RSS-1013 Reuter-Stokes high pressure ionization chamber filled with Ar at 25 atm. The HPIC detector was tested using cosmic radiation and several external radiation sources. Combined measurements of total ionization and ionization spectrum in the detector provide a new type of powerful instrument capable of better separation between the natural background radiation and the radiation form external sources, as well as the improved low energy gamma radiation detection.

Popov, Vladimir↗

Pulse shape discrimination performance of stilbene coupled to low-noise silicon photomultipliers

Pulse shape discrimination (PSD) techniques can be used to discern between neutron and gamma-ray interactions in certain organic scintillators. Traditionally, photomultiplier tubes (PMTs) have been used in organic-scintillator assemblies. However, silicon photomultipliers (SiPMs) have great potential to be used in many applications in which PMTs have been predominantly used, including those utilizing PSD techniques. To evaluate the current state of the art of the SiPM technology, SensL's 6-mm B-Series and C-Series SiPMs were compared to a fast Hamamatsu PMT in conjunction with a 6×6×6-mm3 stilbene organic scintillator to assess the PSD performance of the detector assemblies. Measurements with a Cf-252 source were performed and a figure of merit (FOM) for discriminating between neutron and gamma-ray pulses between 100 keVee and 200 keVee was calculated for each assembly. A digital charge-integration PSD technique was used to process all measured data. The FOM for the B-Series SiPM, PMT, and C-Series SiPM was 1.37, 1.93, and 2.13, respectively. The C-Series SiPM was shown to perform as well as the PMT in the experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Air Shower Measurements with Radio Antennas: The LOPES Project

LOPES is set up at the location of the KASCADE-Grande extensive air shower experiment in Karlsruhe, Germany and aims to measure and calibrate radio pulses from Extensive Air Showers. LOPES is designed as a digital radio interferometer using high bandwidths and fast data processing and profits from the reconstructed air shower observables of KASCADE-Grande. First results of the LOPES experiment are very promising for a future large scale application of the technique to detect cosmic rays of highest energies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigation of a digitizer for the plastic scintillation detectors of time-of-flight mass measurements

A CAEN DT5742 digitizer has been investigated to process the fast signals from the photomultiplier tubes of the time-of-flight detectors for fast ion beams. A test setup consisting of two plastic scintillation detectors and a pulsed laser source provided signals which were recorded by the digitizer and systematically analyzed with different algorithms to derive the amplitude, rise time and arrival time of the detection signal. To obtain the best amplitude and time resolutions, various optimization techniques including peak fitting and signal smoothing, interpolation improvement, and time-walk correction by amplitude and rise time have been performed and compared in detail. Here we compared the time resolutions obtained by three digital algorithms of leading-edge, zero-crossing constant-fraction (ZC-CFD) and direct constant-fraction discriminations. Finally, we found that the best time-of-flight resolution between two PMTs can be achieved as 12 ps by the method using sample minimum for peak location and using the time-walk-resistant ZC-CFD with 4-point interpolation for timing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

FPGA-based trigger system for the LUX dark matter experiment

LUX is a two-phase (liquid/gas) xenon time projection chamber designed to detect nuclear recoils resulting from interactions with dark matter particles. Signals from the detector are processed with an FPGA-based digital trigger system that analyzes the incoming data in real-time, with just a few microsecond latency. The system enables first pass selection of events of interest based on their pulse shape characteristics and 3D localization of the interactions. It has been shown to be >99% efficient in triggering on S2 signals induced by only few extracted liquid electrons. It is continuously and reliably operating since its full underground deployment in early 2013. This document is an overview of the systems capabilities, its inner workings, and its performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Differential B-dot and D-dot monitors for current and voltage measurements on a 20-MA 3-MV pulsed-power accelerator.

We have developed a system of differential-output monitors that diagnose current and voltage in the vacuum section of a 20-MA 3-MV pulsed-power accelerator. The system includes 62 gauges: 3 current and 6 voltage monitors that are fielded on each of the accelerator's 4 vacuum-insulator stacks, 6 current monitors on each of the accelerator's 4 outer magnetically insulated transmission lines (MITLs), and 2 current monitors on the accelerator's inner MITL. The inner-MITL monitors are located 6 cm from the axis of the load. Each of the stack and outer-MITL current monitors comprises two separate B-dot sensors, each of which consists of four 3-mm-diameter wire loops wound in series. The two sensors are separately located within adjacent cavities machined out of a single piece of copper. The high electrical conductivity of copper minimizes penetration of magnetic flux into the cavity walls, which minimizes changes in the sensitivity of the sensors on the 100-ns time scale of the accelerator's power pulse. A model of flux penetration has been developed and is used to correct (to first order) the B-dot signals for the penetration that does occur. The two sensors are designed to produce signals with opposite polarities; hence, each current monitor may be regarded as a single detector with differential outputs. Common-mode-noise rejection is achieved by combining these signals in a 50-{Omega} balun. The signal cables that connect the B-dot monitors to the balun are chosen to provide reasonable bandwidth and acceptable levels of Compton drive in the bremsstrahlung field of the accelerator. A single 50-{omega} cable transmits the output signal of each balun to a double-wall screen room, where the signals are attenuated, digitized (0.5-ns/sample), numerically compensated for cable losses, and numerically integrated. By contrast, each inner-MITL current monitor contains only a single B-dot sensor. These monitors are fielded in opposite-polarity pairs. The two signals from a pair are not combined in a balun; they are instead numerically processed for common-mode-noise rejection after digitization. All the current monitors are calibrated on a 76-cm-diameter axisymmetric radial transmission line that is driven by a 10-kA current pulse. The reference current is measured by a current-viewing resistor (CVR). The stack voltage monitors are also differential-output gauges, consisting of one 1.8-cm-diameter D-dot sensor and one null sensor. Hence, each voltage monitor is also a differential detector with two output signals, processed as described above. The voltage monitors are calibrated in situ at 1.5 MV on dedicated accelerator shots with a short-circuit load. Faraday's law of induction is used to generate the reference voltage: currents are obtained from calibrated outer-MITL B-dot monitors, and inductances from the system geometry. In this way, both current and voltage measurements are traceable to a single CVR. Dependable and consistent measurements are thus obtained with this system of calibrated diagnostics. On accelerator shots that deliver 22 MA to a low-impedance z-pinch load, the peak lineal current densities at the stack, outer-MITL, and inner-MITL monitor locations are 0.5, 1, and 58 MA/m, respectively. On such shots the peak currents measured at these three locations agree to within 1%.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Performance of a fast digital integrator in on-field magnetic measurements for particle accelerators

The fast digital integrator has been conceived to face most demanding magnet test requirements with a resolution of 10 ppm, a signal-to-noise ratio of 105 dB at 20 kHz, a time resolution of 50 ns, an offset of 10 ppm, and on-line processing. In this paper, the on-field achievements of the fast digital integrator are assessed by a specific measurement campaign at the European Organization for Nuclear Research (CERN). At first, the architecture and the metrological specifications of the instrument are reported. Then, the recent on-field achievements of (i) {+-}10 ppm of uncertainty in the measurement of the main field for superconducting magnets characterization, (ii) {+-}0.02 % of field uncertainty in quality assessment of small-aperture permanent magnets, and (iii) {+-}0.15 % of drift, in an excitation current measurement of 600 s under cryogenic conditions, are presented and discussed.

43 PARTICLE ACCELERATORS↗

The power of event-driven analytics in Large Scale Data Processing

FeedZai is a software company specialized in creating high-­‐throughput low-­‐latency data processing solutions. FeedZai develops a product called "FeedZai Pulse" for continuous event-­‐driven analytics that makes application development easier for end users. It automatically calculates key performance indicators and baselines, showing how current performance differ from previous history, creating timely business intelligence updated to the second. The tool does predictive analytics and trend analysis, displaying data on real-­‐time web-­‐based graphics. In 2010 FeedZai won the European EBN Smart Entrepreneurship Competition, in the Digital Models category, being considered one of the "top-­‐20 smart companies in Europe". The main objective of this seminar/workshop is to explore the topic for large-­‐scale data processing using Complex Event Processing and, in particular, the possible uses of Pulse in the scope of the data processing needs of CERN. Pulse is available as open-­‐source and can be licensed both for non-­‐commercial and commercial applications. FeedZai is interested in exploring possible synergies with CERN in high-­‐volume low-­‐latency data processing applications. The seminar will be structured in two sessions, the first one being aimed to expose the general scope of FeedZai's activities, and the second focused on Pulse itself: 10:00-11:00 FeedZai and Large Scale Data Processing; Introduction to FeedZai; FeedZai Pulse and Complex Event Processing; Demonstration; Use-Cases and Applications; Conclusion and Q&A. 11:00-11:15 Coffee break 11:15-12:30 FeedZai Pulse Under the Hood; A First FeedZai Pulse Application; PulseQL overview; Defining KPIs and Baselines; Conclusion and Q&A. About the speakers Nuno Sebastião is the CEO of FeedZai. Having worked for many years for the European Space Agency (ESA), he was responsible the overall design and development of Satellite Simulation Infrastructure of the agency. Having left ESA to found FeedZai, Nuno is currently responsible for the whole operations of the company. Nuno holds an M.Eng. in Informatics Engineering for the University of Coimbra, and an MBA from the London Business School. Paulo Marques is the CTO of FeedZai, being responsible for product development. Paulo is an Assistant Professor at the University of Coimbra, in the area of Distributed Data Processing, and an Adjunct Associated Professor at Carnegie Mellon, in the US. In the past Paulo lead a large number of projects for institutions like the ESA, Microsoft Research, SciSys, Siemens, among others, being now fully dedicated to FeedZai. Paulo holds a Ph.D. in Distributed Systems from the University of Coimbra.

97 MATHEMATICS AND COMPUTING↗

Towards Digital and Performance-Based Supervisory HVAC Control Delivery

Upgrading supervisory HVAC control in commercial buildings is one of the most attractive decarbonization tools at our disposal. Modern controls are software programs and can in theory be deployed at scale and with a low up-front carbon "pulse". In practice, however, control delivery is a disjointed and inefficient process, dominated by manual handoffs of imprecise English language documents. A particularly high barrier exists between control implementation and building energy modeling (BEM) which results in control sequences typically not being tested for correctness or performance before implementation. Together with industry partners, DOE and the national labs are developing an ecosystem of tools and standards that can support fully digital performance-based control delivery workflows. This paper describes this ecosystem, which consists of three mutually supportive efforts. Semantic models of buildings and their systems enable automatic configuration and installation of control software. Platform-neutral control descriptions separate control algorithms from control platforms and enable the creation of libraries of reference control implementations. Dynamic whole-building energy-control simulation that can execute physically realistic control sequences makes it possible to test and evaluate the performance of control sequences and then directly compile them for installation and execution in control systems. In addition to digitizing and streamlining project-level control delivery, these standards and related software support benchmarking of control algorithms, both rule-based and optimization-based, and help to both advance the state of the art and to implement ratings and programs that encourage the adoption of high-performance control.

building controls↗

Hahn-Echo Assisted Deconvolution (HEAD)

This repository contains the Bruker pulse program for acquire 2D HEAD data in addition to the C++ program used for data processing. Data must be acquired with identical digital resolution in both dimensions. The resulting 2D spectrum is converted to a ASCII file using the Topspin 'totxt' command. This file can be handled by the HEAD_processing program.

Perras, Frederic [Ames National Laboratory; Ames N↗