Search NASA⌕ Search

SEARCH · Search NASA

Results for “direct power control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

A Scalable, Distribution Network-Aware, Customer Privacy-Preserving Framework for Operation of Virtual Power Plants

This poster presents a hierarchical control framework for a virtual power plant that leverages behind-the-meter resources for grid services while maintaining customer privacy during setpoint disaggregation. Unlike many existing approaches, the virtual power plant model uses a hierarchical control strategy and an iterative approach to determine the optimal set point dis-aggregation without direct load control while maintaining system-level power flow and voltage constraints. The proposed approach is numerically validated on a synthetic distribution feeder in San Francisco, demonstrating the ability of the framework to provide privacy-preserving virtual power plant services.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Integrated Stirling Convertor and Hall Thruster Test Conducted

An important aspect of implementing Stirling Radioisotope Generators on future NASA missions is the integration of the generator and controller with potential spacecraft loads. Some recent studies have indicated that the combination of Stirling Radioisotope Generators and electric propulsion devices offer significant trip time and payload fraction benefits for deep space missions. A test was devised to begin to understand the interactions between Stirling generators and electric thrusters. An electrically heated RG- 350 (350-W output) Stirling convertor, designed and built by Stirling Technology Company of Kennewick, Washington, under a NASA Small Business Innovation Research agreement, was coupled to a 300-W SPT-50 Hall-effect thruster built for NASA by the Moscow Aviation Institute (RIAME). The RG-350 and the SPT-50 shown, were installed in adjacent vacuum chamber ports at NASA Glenn Research Center's Electric Propulsion Laboratory, Vacuum Facility 8. The Stirling electrical controller interfaced directly with the Hall thruster power-processing unit, both of which were located outside of the vacuum chamber. The power-processing unit accepted the 48 Vdc output from the Stirling controller and distributed the power to all the loads of the SPT-50, including the magnets, keeper, heater, and discharge. On February 28, 2001, the Glenn test team successfully operated the Hall-effect thruster with the Stirling convertor. This is the world's first known test of a dynamic power source with electric propulsion. The RG-350 successfully managed the transition from the purely resistive load bank within the Stirling controller to the highly capacitive power-processing unit load. At the time of the demonstration, the Stirling convertor was operating at a hot temperature of 530 C and a cold temperature of -6 C. The linear alternator was producing approximately 250 W at 109 Vac, while the power-processing unit was drawing 175 W at 48 Vdc. The majority of power was delivered to the Hall thruster discharge circuit operating at 115 Vdc and 0.9 A. Testing planned for late 2001 will examine the possibility of directly driving the Hall thruster discharge circuit using rectified and filtered output from the Stirling alternator.

Mason, Lee S.↗

A safe reinforcement learning algorithm for supervisory control of power plants

Traditional control theory-based methods require tailored engineering for each system and constant fine-tuning. In power plant control, one often needs to obtain a precise representation of the system dynamics and carefully design the control scheme accordingly. Model-free Reinforcement learning (RL) has emerged as a promising solution for control tasks due to its ability to learn from trial-and-error interactions with the environment. It eliminates the need for explicitly modeling the environment’s dynamics, which is potentially inaccurate. However, the direct imposition of state constraints in power plant control raises challenges for standard RL methods. To address this, we propose a chance-constrained RL algorithm based on Proximal Policy Optimization for supervisory control. Our method employs Lagrangian relaxation to convert the constrained optimization problem into an unconstrained objective, where trainable Lagrange multipliers enforce the state constraints. In conclusion, our approach achieves the smallest distance of violation and violation rate in a load-follow maneuver for an advanced Nuclear Power Plant design.

constrained optimization↗

Controller for a string engine

Hydraulic mechanism enables operator to adjust power and rotational direction of output of Stirling engine by applying only small force to control lever. Stirling engine has expander and displacer sections.

Mcdougal, A. R.↗

Physics-based modeling and information-theoretic sensor and settings selection for tool wear detection in precision machining

Precision machining of metals is an energy intensive process with applications and impacts across the manufacturing industry. The energy efficiency, product yield, and maintenance of the precision machine require a digital twin that can assist with prognostics and health management. In this report a physics-based model is developed and validated against face milling data, and then used for the timely and precise inference of machining faults that cannot be measured directly. Computer numerical control (CNC) measurements of power and force are used through this physics-based machining model to predict deviations of the outputs of power consumption and cutting forces during normal operation. A model-based fault detection and isolation methodology is applied to determine the optimal (traditional and available) sensor suite and the test settings (admissible input values) that improve the inference of tool wear in face milling. The optimal sensor suite and input test settings are obtained by solving a mixed integer non-linear program that optimizes information-theoretic metrics relevant to the detection and isolation of tool wear from steady-state or transient machining measurements. Dynamic time warping and k—NN classification are then used to validate the robustness of the optimal design for fault detection test design, including the optimal sensor suite.

42 ENGINEERING↗

Embedded EPICS server for PowerPMAC motion controllers

An embedded server layer of Experimental Physics and Industrial Control System (EPICS) for PowerPMAC motion controllers has been developed and deployed at two undulator beamlines of the National Institute of General Medical Sciences and the National Cancer Institute (GM/CA) Structural Biology Facility at the Advanced Photon Source (APS). This compact, open source solution makes the power and versatility of PowerPMAC motion controls directly accessible to distributed EPICS clients. At GM/CA the system controls about 200 servo and stepper motors — both encoded and unencoded — and multiple digital and analog I/O accessories. The server stack comprises two sublayers: a lower-level driver and database that communicates directly with PowerPMAC, and a facility-specific soft sublayer built on top. The paper describes installing EPICS on PowerPMAC, the implementation of both layers and client examples, including on-the-fly scanning.

EPICS↗

Chandra Space Flight Software: Using Software to Autonomously Operation the Largest and Most Sensitive X-Ray Telescope in the World

Chandra is the world's largest and most sensitive X-ray telescope. The Chandra X-ray Observatory is the third in NASA's family of "Great Observatories." The Chandra X-ray Observatory, launched by Space Shuttle Columbia on July 23, 1999, is NASA's newest Great Observatory. The Chandra space flight software is the operational software, which controls and directs the Chandra X-ray Observatory. The Chandra flight software has executed faultlessly for over 13,000 hours on-orbit. The Chandra flight software directly controls the Pointing, Aspect Determination, Electrical Power Subsystem, Propulsion system, and the Command, Communications, and Data Management subsystems. The software controls the spacecraft operations during all phases of the mission. The software also performs thermal control of the telescope to maintain pointing accuracy and monitors radiation levels throughout the orbit so that the Science Instruments can be safed if radiation thresholds are exceeded. The efficient operation of Chandra flight software has enabled the gathering of crucial science data. The Chandra flight software fault protection is the key to early detection and prevention of science instrument or spacecraft damage in an operating platform/environment, which is completely unforgiving. Permanently open Sun Shade Door and ACIS focal plane radiator sensitivity exposes science instruments and mirrors to damage for pointing anomalies causing an attitude excursion. The Chandra flight software must prevent these attitude excursions from occurring for ANY failure. Another example is that the power system has an unregulated bus, which imposes severe operating requirements on Chandra flight software to control array pointing and battery connection/disconnect using a unique algorithmic and logic approach. The Chandra flight software has enabled a truly autonomous vehicle with greater than 99% of all mission data collected as planned. Less than 15% of spacecraft operations are conducted in view (1 hour out of 8) leading to very extended periods without ground contact. The Chandra flight software implements the flexible mission plan during this out of view period, manages the solid state recorder capacity, controls all pointing and maneuvers, provides fault detection for all satellite subsystems, and initiates communications with the ground at the appropriate time. This paper will describe the software architecture features, key design elements and software testing techniques that have facilitated Chandra's success.

Crumbley, Tim↗

Description of a 20 Kilohertz power distribution system

A single phase, 440 VRMS, 20 kHz power distribution system with a regulated sinusoidal wave form is discussed. A single phase power system minimizes the wiring, sensing, and control complexities required in a multi-sourced redundantly distributed power system. The single phase addresses only the distribution link; mulitphase lower frequency inputs and outputs accommodation techniques are described. While the 440 V operating potential was initially selected for aircraft operating below 50,000 ft, this potential also appears suitable for space power systems. This voltage choice recognizes a reasonable upper limit for semiconductor ratings, yet will direct synthesis of 220 V, 3 power. A 20 kHz operating frequency was selected to be above the range of audibility, minimize the weight of reactive components, yet allow the construction of single power stages of 25 to 30 kW. The regulated sinusoidal distribution system has several advantages. With a regulated voltage, most ac/dc conversions involve rather simple transformer rectifier applications. A sinusoidal distribution system, when used in conjunction with zero crossing switching, represents a minimal source of EMI. The present state of 20 kHz power technology includes computer controls of voltage and/or frequency, low inductance cable, current limiting circuit protection, bi-directional power flow, and motor/generator operating using standard induction machines. A status update and description of each of these items and their significance is presented.

Hansen, I. G.↗

Description of a 20 kilohertz power distribution system

A single phase, 440 VRMS, 20 kHz power distribution system with a regulated sinusoidal wave form is discussed. A single phase power system minimizes the wiring, sensing, and control complexities required in a multi-sourced redundantly distributed power system. The single phase addresses only the distribution links multiphase lower frequency inputs and outputs accommodation techniques are described. While the 440 V operating potential was initially selected for aircraft operating below 50,000 ft, this potential also appears suitable for space power systems. This voltage choice recognizes a reasonable upper limit for semiconductor ratings, yet will direct synthesis of 220 V, 3 power. A 20 kHz operating frequency was selected to be above the range of audibility, minimize the weight of reactive components, yet allow the construction of single power stages of 25 to 30 kW. The regulated sinusoidal distribution system has several advantages. With a regulated voltage, most ac/dc conversions involve rather simple transformer rectifier applications. A sinusoidal distribution system, when used in conjunction with zero crossing switching, represents a minimal source of EMI. The present state of 20 kHz power technology includes computer controls of voltage and/or frequency, low inductance cable, current limiting circuit protection, bi-directional power flow, and motor/generator operating using standard induction machines. A status update and description of each of these items and their significance is presented.

Hansen, I. G.↗

Automated Power-Distribution System

Automated power-distribution system monitors and controls electrical power to modules in network. Handles both 208-V, 20-kHz single-phase alternating current and 120- to 150-V direct current. Power distributed to load modules from power-distribution control units (PDCU's) via subsystem distributors. Ring busses carry power to PDCU's from power source. Needs minimal attention. Detects faults and also protects against them. Potential applications include autonomous land vehicles and automated industrial process systems.

Thomason, Cindy↗

Optimized V1G and V2G Electric Vehicle Fleet Management and Grid Transaction at Marine Corps Air Station Miramar in San Diego, CA

The overall technical goal of the project was to demonstrate an all-electric bi-directional non-tactical fleet at Marine Corps Air Station (MCAS) Miramar that was integrated and controlled with other distributed energy resources (DERs) (i.e., PV, stationary battery, and building loads) to provide resilience to critical electric loads in the event of grid outages, to minimize charging costs, and to provide economic energy resources to electricity markets. In this project, the specific, technical objectives were: 1. Demonstrate that bi-directional electric vehicles can provide critical complementary services to fixed storage batteries in microgrid applications while performing function as non-tactical vehicles. 2. Demonstrate participation of bi-directional (V2G) and unidirectional (V1G) PEVs for demand management and minimization of charging costs. 3. Demonstrate integration of multiple DERs for grid service participation. US Marine Corps Air Station (MCAS) Miramar in San Diego was the site of this electric vehicle-to-microgrid-utility grid test and demonstration project. Existing microgrid assets in this study included (1) a public works building; (2) a 30-kW rooftop photovoltaic (PV) system and (3) a separate 250 kW carport PV system. In this project, six bi-directional V2G vans were located at the MCAS Miramar’s showcase building-scale microgrid to develop and test technical capabilities that V2G can provide in microgrid applications (e.g., cost reduction and resiliency). These resources provided aggregated demand management and simulated participation in current retail DR programs. The vehicles used in this demonstration were selected because they provided functionality that MCAS Miramar needed, 15 passenger transport and facilities work cargo carrying capacity, and bi-directional charging capability that the research project required. All vehicles in this study were manufactured and distributed by VIA Motors, Inc. There were six vehicles total and each was VIA’s VTRUX eREV V2G model, a modified General Motors Chevrolet 2500 2WD van. Three of the vans were configured as passenger vans and the other three were configured as cargo vans. Each van had an on-board bi-direcrtional inverter/charger, Bel Power Solutions model 350INVCHGT150-120-240-8G nominally rated at +/-15 kW. The VIA van’s charging connector follows the J1772 charging protocol. The bi-directional EVSEs demonstrated in this study were manufactured by Coritech, Inc. Each VGI-80-AC charging station enabled enhanced V2G charging capability to a Clipper Creek CS-100 charging module. The enhanced capabilities included ethernet communication following the SEP2.0 protocol with a distributed energy resource function set and an operator screen displaying real-time SOC, voltage, and current. The VGI-80-AC charging stations are classified as level 2 with a maximum current output of 80 A or effectively 19 kW. The VIA van’s onboard charger limited the charging and discharging power to 15 kW in each direction. A control computer was installed in the EWOC and connected to an existing monitor. The V2G control communication network was a completely stand-alone closed system that did not have any connection to any other networks on the base. A cybersecure remote communication connection was created with a cellular modem, firewall hardware, and a virtual private network configuration.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Extension of Argonne’s Plant Dynamics Code (PDC) Capabilities to TerraPower Direct-Cycle Supercritical CO2 (“Pascal”) Nuclear Reactor Concept. Final CRADA report

Argonne National Laboratory (the Contractor) and TerraPower, LLC, (the Participant), entered into a Cooperative Research and Development Agreement (CRADA) to extend the Plant Dynamics Code (PDC) to model the Pascal reactor plant. PDC is the system-level computer code developed at Argonne, primarily for design and transient analysis of supercritical carbon dioxide (sCO2) energy conversion systems for various power plants. Pascal is a supercritical carbon dioxide (sCO2)-cooled direct-cycle nuclear power reactor under development by TerraPower. New features were added to the code to model components and systems specific to the Pascal plant and to make the code readily available as a tool for design, control, and safety analysis for this and other direct-cycle power plants. TerraPower provided design information of the Pascal reactor and the requirements for the development of the new PDC features. Argonne modified the PDC capabilities to introduce the new features.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Constrained power reference control for wind turbines

The cost of wind energy can be reduced by controlling the power reference of a turbine to increase energy capture, while maintaining load and generator speed constraints. We apply standard torque and pitch controllers to the direct inputs of the turbine and use their set points to change the power output and reduce generator speed and blade load transients. A power reference controller increases the power output when conditions are safe and decreases it when problematic transient events are expected. Transient generator speeds and blade loads are estimated using a gust measure derived from a wind speed estimate. A hybrid controller decreases the power rating from a maximum allowable power. Compared to a baseline controller, with a constant power reference, the proposed controller results in generator speeds and blade loads that do not exceed the original limits, increases tower fore-aft damage equivalent loads by 1%, and increases the annual energy production by 5%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Implementation and Operation of Power Flow Control Solutions for Transmission Systems

Power-flow controls (PFCs) technologies provide a suite of alternatives to more-efficiently direct the flow of power on the grid, improving flexibility and enabling the grid to be more responsive and resilient. PFCs can be used in many cases to mitigate overloads and consequently defer the installation of grid-expansion projects. They can also be suitable options in situations where new transmission lines cannot be built because of environmental constraints, land use, or other types of restrictions. Other uses include mitigation of loop or unintended flows, forcing of contractual or scheduled flows, reduction of congestion, and mitigation solutions during large maintenance or construction projects. While many studies have demonstrated the potential economic benefits of PFC for different types of applications, the implementation implications of using multiple PFCs for system operation and reliability have not been analyzed in detail. The lack of information and practical experience on these aspects hinders adoption of this technology. One use case would be that multiple PFCs are required to coordinate congestion management. In such cases, multiple PFCs are deployed in a meshed power system to control power flows across a wide area. The challenges are associated with PFC interaction—namely, the self and mutual power-flow sensitivity of each PFC, which must be accounted for in the calculation of the respective operating setpoints. This report analyzes implementation and operation that must be considered in evaluating transmission solutions using PFCs. The report first analyzes attributes with which PFC-based solutions should comply, based on the objective and characteristics of each particular use case. It then describes different approaches for coordinated control of multiple PFC devices for different applications, including options to avoid adverse interactions and reduce risks due to inappropriate coordination. Control and operation are illustrated through case studies performed on both generic and actual power system models. This report provides insights for transmission planners and operation engineers about the implementation of PFC-based transmission solutions; consequently, it will help them make informed decisions about the adoption of the technology.

24 POWER TRANSMISSION AND DISTRIBUTION↗

EVs@Scale Lab Consortium High-Power Charging Pillar Deep-Dive Technical Meeting

Managed under the the U.S. Department of Energy (DOE)-funded EVs@Scale Consortium, the High-Power Electric Vehicle Charging Hub Integration Platform (eCHIP) project aims to create an experimental platform for integration and control approaches in a direct current (DC), distribution-based high-power charging (HPC) system. The eCHIP project addresses the crucial need to design and validate efficient, low-cost, reliable, and interoperable solutions for a DC-coupled charging hub ("DC hub" for short). This report explains the design, development, and implementation process of an experimental platform for the DC hub. DC distribution holds significant potential for enhancing the operation of an HPC station architecture. However, there are challenges in establishing a DC hub, including interoperability, commoditization, distributed energy resource integration, stability, DC protection, and a lack of common system-level controllers. To address these challenges, a testing setup is required that accommodates commercial off-the-shelf (COTS) products, as well as novel, in-house designed solutions, to evaluate different use cases at rated power and voltage levels. The developed proof-of-concept charging platform and open-source SEMS allow the development and testing of various controllers and chargers from different vendors. The DC hub platform integrated EVs, an ESS, a PV system, and building load to demonstrate the flexibility of the platform. The open-source SEMS controlled the devices within the hub using a rule-based implementation, realizing available standards.

ADVANCED PROPULSION SYSTEMS↗

Wake Steering Wind Farm Control With Preview Wind Direction Information: Preprint

Wake steering is a wind farm control strategy in which upstream turbines operate with a yaw misalignment to deflect their wakes away from downstream turbines, yielding a net power gain for the wind plant. But the inability of wake steering controllers to perfectly track the wind direction leads to suboptimal performance. In this paper, we propose the use of preview wind direction measurements upstream of the turbine to improve controller performance by anticipating wind direction changes. Further, data from an operational wind plant are used to determine realistic preview measurement accuracy. Using the FLORIS engineering wind farm control tool, we compare the performance of standard and preview-enabled baseline and wake steering control for a two-turbine array during below-rated operation. Assuming perfect preview information, preview-based wake steering increases energy production by the equivalent of 9.5% of the baseline wake losses, compared to a wake loss recovery of 5.6% with standard wake steering. However, when realistic measurement accuracy is included, the preview-based controller provides no advantage over standard control, motivating the need for more sophisticated control and wind direction forecasting strategies.

49 EE - Wind and Water Power Program - Wind (EE-4W↗

Performance of Heterogeneous Algorithm Scheduling in CMSSW

The CMS experiment started to utilize Graphics Processing Units (GPU) to accelerate the online reconstruction and event selection running on its High Level Trigger (HLT) farm in the 2022 data taking period. The projections of the HLT farm to the High-Luminosity LHC foresee a significant use of compute accelerators in the LHC Run 4 and onwards in order to keep the cost, size, and power budget of the farm under control. This direction of leveraging compute accelerators has synergies with the increasing use of HPC resources in HEP computing, as HPC machines are employing more and more compute accelerators that are predominantly GPUs today. In this work we review the features developed for the CMS data processing framework, CMSSW, to support the effective utilization of both compute accelerators and many-core CPUs within a highly concurrent task-based framework. We measure the impact of various design choices for the scheduling of heterogeneous algorithms on the event processing throughput, using the Run-3 HLT application as a realistic use case.

Bocci, Andrea↗