Search NASA⌕ Search

SEARCH · Search NASA

Results for “directional cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Direct numerical simulations of turbulent premixed cool flames: Global and local flame dynamics analysis

The cool flame dynamics, especially in turbulent flows, is of great interest for both practical application and fundamental research. Here, in this study, a series of direct numerical simulations of turbulent premixed n-C 7 H 16 /O 2 /O 3 /N 2 cool flames are performed, with the focus on the influence of turbulence intensity (u'/S L , where S L is the laminar flame speed) on the flame structure as well as the global and local cool flame dynamics. It is found that the cool flame front is considerably wrinkled by turbulence at high u'/S L , leading to significantly thickened turbulent cool flame brush and largely altered local reactivity compared with the reference laminar flame. However, the turbulent flame structure in the temperature space is found to be insensitive to u'/S L . Besides, with increasing u'/S L , the normalized turbulent cool flame speed (S L /S L ) is monotonically increased, attributed to substantial augmentation on the flame surface area (A T /A L ), while the stretching factor (I 0 ) remains almost constant and is smaller than 1. The underlying mechanisms for such variations are revealed through local flame dynamics analysis. Specifically, the local flame displacement speed S d is found to be strongly negatively correlated with flame curvature; meanwhile, such negative correlation and the probability distribution function (PDF) of flame curvature are barely influenced by u'/S L , leading to a weak dependence of I 0 on u'/S L . In contrast, the PDF of the tangential strain rate is found to span a much wider range and shift to the positive side as u'/S L increases, suggesting that the enhanced tangential strain rate is the main cause for the increase in surface area of the turbulent premixed cool flame. Finally, the influence of equivalence ratio on above findings is found to be insignificant, indicating that although the local reactivity of turbulent premixed cool flames is altered due to the differential diffusion, the resultant flame- stretch interaction is insensitive to the equivalence ratio. This study presents some unique cool flame dynamics that are distinct from hot flames, which can help improve the understanding and modeling of turbulent cool flames.

Cool flames↗

Effects of stratification and charge cooling on combustion in a gasoline direct-injection compression ignition (GDCI) engine

With the development of low temperature engine combustion strategies, performance of gasoline-type fuels under compression ignition conditions has attracted extensive research interest. Meanwhile, for the sake of co-optimization of engines and fuels for future ground transportation, identification and evaluation of general fuel properties should be a core research priority instead of endless testing of specific fuels. In this study, the roles of fuel octane sensitivity in characterizing the ignition performance of gasoline surrogates have been systematically investigated under typical gasoline direct ignition compression ignition (GDCI) engine conditions using 3D combustion CFD simulation, especially considering the subsequent in-cylinder charge stratification and charge cooling. Two different operating conditions, high boost pressure low boost temperature (beyond-RON) case and low boost pressure high boost temperature (beyond-MON) case, were considered. By comparing with our previous zero-dimensional chemical kinetic study of gasoline surrogates in advanced compression ignition (ACI) engines, the effects of stratification and charge cooling on the combustion processes are investigated. It is found that different fuel octane sensitivities lead to slight difference in equivalence ratio stratification and charge cooling due to differences in volatility. However, fuel reactivity is still the more dominant factor than the stratification and charge cooling effects in determining combustion phasing. The present results help to justify the P-T domain framework for engine autoignition analysis of overlapping pressure-temperature trajectory with ignition delay iso-contour. Here, the results also provide useful guidance to the understanding of GCI combustion process, and to the evaluation of controlling fuel properties and the selection of alternative fuels in GCI engines.

33 ADVANCED PROPULSION SYSTEMS↗

Pilgrim Hot Springs: GEOPHIRES Inputs and Outputs for Direct-Use Geothermal District Heating and Cooling

This dataset includes files for a techno-economic analysis conducted using the GEOPHIRES simulator to examine the feasibility of expanding a larger district heating site in a remote location: Pilgrim Hot Springs, Alaska. Files included here are GEOPHIRES inputs and outputs for five different scenarios with varying demand, cycle, and system design characteristics to analyze. Also included is the link to the GEOPHIRES GitHub, as well as a link to the dataset that contains the energy modelling used to determine the heating demand for the district. For a list of the differences between scenarios, see the included "Input Overview.txt" file. Fields included in the input files are: subsurface technical parameters, surface technical parameters, financial parameters, capital and O&M parameters, as well as simulation parameters. The output files are case reports that summarize all equipment, reservoir characteristics, costs, and heating profiles.

15 GEOTHERMAL ENERGY↗

Stochastic scheduling for commercial building cooling systems: considering uncertainty in zone temperature prediction

Here, this paper presents the first attempt to address the uncertainty in zone temperature prediction with stochastic optimization. The uncertain zone temperature is a process uncertainty and has not been considered in the existing stochastic optimization for building control. To fill this gap, we proposed a novel formulation of stochastic optimization to handle process uncertainty in building control. Specifically, we first examined the accuracy of a typical linear model for predicting zone temperature. We then formulated the scheduling of the building cooling system as a stochastic optimization problem over a 24-hour look-ahead period to minimize the electricity cost of the studied building cooling system. After that, we applied the proposed stochastic load scheduling (SLS) to a direct expansion (DX) cooling system that serves a medium office building. Through simulation with a detailed building energy simulation software, EnergyPlus, we evaluated the operational cost and the thermal comfort compared with a deterministic load scheduling. The operation cost of scheduling was found to vary with the level of zone temperature prediction uncertainty. The proposed SLS can mitigate the impacts of uncertain zone temperature predictions on both operational cost and thermal comfort. The evaluation results indicate that the proposed SLS works better when the uncertainty level is more significant.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cooling rate and dendrite spacing control in direct metal deposition printed Cu-Fe alloys

Over the last several decades, additive manufacturing (AM) has been primarily used for rapid prototyping or to create novel geometries that would be difficult or impossible to create by normal manufacturing methods. More recently, research has been focused on expanding the list of materials that can be made through additive manufacturing, opening a greater range of material properties for this manufacturing method. Due to the unusual conditions during AM, including the high cooling rates and voxel by voxel method of production, AM parts often have anisotropic material microstructures and properties. In this investigation, the laser power, composition, and nozzle head speed during direct metal deposition of copper-iron alloys was varied to understand how the grain structure within the printed parts could be changed and controlled. The resulting dendrite spacing was measured and compared to calculated cooling rates from Gaussian beams on flat plates under similar material and laser properties, which resulted in a cooling rate to dendrite spacing relationship following an inverse square root, as is found in other dendritic systems [Young and Kerkwood, Metall. Trans. A 6, 197–205 (1975)]. Thus, it is demonstrated that in the Cu-Fe system, dendrite spacing can be controlled through manipulation of printing parameters.

36 MATERIALS SCIENCE↗

Water Recovery From Cooling Tower Plumes

According to studies by the UN and the US State Department, we are on the path to an extreme freshwater shortage by 2030. The US’s largest water withdrawal source is power plants, which account for 39% of total US freshwater withdrawals, mostly for cooling. Cooling towers are the most common cooling system. To solve these problems and enable efficient water- based cooling – Infinite Cooling’s novel technology uses electric fields to ionize the air, charge the escaping water leaving cooling towers and direct the water toward mesh collectors where it collects and gets recycled for use in the cooling system. This technology was developed at MIT and was reduced to practice on a lab-scale prototype, and a prototype at the MIT Cogeneration Power Plant. This DOE award funded taking this technology from a lab-scale prototype to TRL 5 on an operating cooling tower in the field at the MIT Nuclear Research Laboratory. The funding helped to design and optimize an electrostatic plume collection system and test it in high-fidelity lab setting and in actual field conditions on a cooling tower. Throughout the award, Infinite Cooling investigated the formation of plumes on cooling towers, used that information to optimize the design, material and electrical properties of the collection device and quantified the collection yield via flow rate and water quality.

20 FOSSIL-FUELED POWER PLANTS↗

U-gas +Cool GTL™ - A New Integrated Process for Direct Biomass Conversion to Liquid Fuels

The U-Gas gasification technology, marketed by Sungas, is a proven fluid bed gasification technology for biomass conversion. U-Gas has been tested on a wide variety of biomass feeds including wood and waste streams. The U-Gas Technology has successfully converted wood for more than 20 years in a gasification plant in Skive Denmark at the 150t/d size. GTI has also recently developed the Cool GTL process for converting biogas to high quality gasoline, jet, and diesel fuels. The technoeconomics and LCA for the combination of the two technologies results an integrated optimized process, which will be discussed. The Cool GTL process is still in development and the development should be complete by 2023. Cool GTL converts high CO2 content feeds to synthesis gas with a 2-2.4/1 H2/CO ratio suitable for fuels synthesis. The process is based on a novel, highly stabile CO2/steam reforming catalyst. The 2.0-2.4/1 H2/CO synthesis gas ratio is always achieved, independently of feed CO2 content, by adjusting the amount of water added according to the amount of CO2 in the feed. The reformer catalyst has been tested for 500 hours and shows no measurable deactivation. The product from the reformer then goes directly to a low temperature slurry bed Fischer Tropsch reactor with an integrated finishing hydroisomerization reactor which makes hydrocarbon liquids from the synthesis gas. With this configuration no wax is produced. The technoeconomics and carbon intensity for the integration of UGas and the Cool GTL processes will be compared to other biomass conversion approaches. The use of electrolysis to boost H2 in the feed and increase liquid production will also be analyzed as a potential process improvement with sensitivities to the cost of electricity and the use of renewable electricity.

09 BIOMASS FUELS↗

Realization of a gas puff imaging system on the Wendelstein 7-X stellarator

A system for studying the spatiotemporal dynamics of fluctuations in the boundary of the W7-X plasma using the “Gas-Puff Imaging” (GPI) technique has been designed, constructed, installed, and operated. This GPI system addresses a number of challenges specific to long-pulse superconducting devices, such as W7-X, including the long distance between the plasma and the vacuum vessel wall, the long distance between the plasma and diagnostic ports, the range of last closed flux surface (LCFS) locations for different magnetic configurations in W7-X, and management of heat loads on the system’s plasma-facing components. The system features a pair of “converging–diverging” nozzles for partially collimating the gas puffed locally ≈135 mm radially outboard of the plasma boundary, a pop-up turning mirror for viewing the gas puff emission from the side (which also acts as a shutter for the re-entrant vacuum window), and a high-throughput optical system that collects visible emission resulting from the interaction between the puffed gas and the plasma and directs it along a water-cooled re-entrant tube directly onto the 8 × 16 pixel detector array of the fast camera. The DEGAS 2 neutral code was used to simulate the Hα (656 nm) and HeI (587 nm) line emission expected from well-characterized gas-puffs of H2 and He and excited within typical edge plasma profiles in W7-X, thereby predicting line brightnesses used to reduce the risks associated with system sensitivity and placement of the field of view. Operation of GPI on W7-X shows excellent signal-to-noise ratios (>100 at 2 Mframes/s) over the field of view for minimally perturbing gas puffs. The GPI system provides detailed measurements of the two-dimensional (radial and poloidal) dynamics of plasma fluctuations in the W7-X edge and scrape-off layer and in and around the magnetic islands outside the LCFS that make up the island divertor configuration employed on W7-X.

Instruments & Instrumentation↗

Two dimensional meta-material windows

Conductive nanoshells are oriented so as to redirect incident radiation as a function of wavelength. Nanoshells can be formed on templates such as nanospheres or gratings and embedded in an elastomeric layer. In some examples, conductive nanoshells are coupled to a layer that is configured to unbuckle and buckle as a function of temperature, so that radiation in one or more wavelength ranges is directed differently at different temperatures. Building windows can include such layers to that infrared radiation is reflected on warm days and directed into a building on cool days. Such layers can also direct incident visible radiation to a room ceiling so as to enhance interior lighting.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Closed-loop brayton cycle system with turbine blade cooling

A closed-loop Brayton cycle system utilizes supercritical carbon dioxide as the working fluid for the system to achieve higher efficiencies than can be achieved with traditional open-loop gas turbine engines. A bleed channel is used to direct a flow of cooling fluid to cool the turbine blades during operation of the system, preventing damage to the turbine blades during operation of the system. The bleed channel includes a bleed inlet fluidly coupled between a first recuperator and a second recuperator and a bleed outlet fluidly coupled to the turbine blades. The bleed channel is configured to direct the flow of cooling fluid to the turbine blades at a desired temperature and pressure.

Taylor, Stephen H.↗

The environmental footprint of data centers in the United States

Much of the world's data are stored, managed, and distributed by data centers. Data centers require a tremendous amount of energy to operate, accounting for around 1.8% of electricity use in the United States. Large amounts of water are also required to operate data centers, both directly for liquid cooling and indirectly to produce electricity. For the first time, we calculate spatially-detailed carbon and water footprints of data centers operating within the United States, which is home to around one-quarter of all data center servers globally. Our bottom-up approach reveals one-fifth of data center servers direct water footprint comes from moderately to highly water stressed watersheds, while nearly half of servers are fully or partially powered by power plants located within water stressed regions. Approximately 0.5% of total US greenhouse gas emissions are attributed to data centers. We investigate tradeoffs and synergies between data center's water and energy utilization by strategically locating data centers in areas of the country that will minimize one or more environmental footprints. Our study quantifies the environmental implications behind our data creation and storage and shows a path to decrease the environmental footprint of our increasing digital footprint.

54 ENVIRONMENTAL SCIENCES↗

Aircraft electric motor

Aircraft electric motors are described. The aircraft electric motors include a motor unit having a rotor and a stator, wherein the stator includes a plurality of windings and cooling channels arranged to provide cooling to the plurality of windings, a drive unit configured to drive operation of the motor unit, and a cooling system having at least one directional feature forming a portion of at least one cooling channel, the at least one directional feature configured to prevent backflow of a cooling fluid that passes through the at least one cooling channel.

Alahyari, Abbas A.↗

High-performance multimode elastocaloric cooling system

Developing zero–global warming potential refrigerants has emerged as one area that helps address global climate change concerns. Various high-efficiency caloric cooling techniques meet this goal, but scaling them up to technologically meaningful performance remains challenging. We have developed an elastocaloric cooling system with a maximum cooling power of 260 watts and a maximum temperature span of 22.5 kelvin. These values are among the highest reported for any caloric cooling system. Its key feature is the compression of fatigue-resistant elastocaloric nitinol (NiTi) tubes configured in a versatile multimode heat exchange architecture, which allows the harnessing of both high delivered cooling power and large temperature spans. Our system shows that elastocaloric cooling, which only emerged 8 years ago, is a promising direction for commercializing caloric cooling.

Science & Technology - Other Topics↗

MELCOR Accident Progression and Source Term Demonstration Calculations for a FHR

MELCOR is an integrated thermal hydraulics, accident progression, and source term code for reactor safety analysis that has been developed at Sandia National Laboratories for the United States Nuclear Regulatory Commission (NRC) since the early 1980s. Though MELCOR originated as a light water reactor (LWR) code, development and modernization efforts have expanded its application scope to include non-LWR reactor concepts. Current MELCOR development efforts include providing the NRC with the analytical capabilities to support regulatory readiness for licensing non-LWR technologies under Strategy 2 of the NRC's near- term Implementation Action Plans. Beginning with the Next Generation Nuclear Project (NGNP), MELCOR has undergone a range of enhancements to provide analytical capabilities for modeling the spectrum of advanced non-LWR concepts. This report describes the generic plant model developed to demonstrate MELCOR capabilities to perform fluoride-salt-cooled high-temperature reactor (FHR) safety evaluations. The generic plant model is based on publicly-available FHR design information. For plant aspects (e.g., reactor building leak rate and details of the cover-gas system) that are not described in the FHR references, the analysts made assumptions needed to construct a MELCOR full-plant model. The FHR model uses a TRi-structural ISOtropic (TRISO)-particle fuel pebble-bed reactor with a primary system rejecting heat to two coiled tube air heat ex changers. Three passive direct reactor auxiliary cooling systems provide heat removal to supplement or replace the emergency secondary system heat removal during accident conditions. Surrounding the reactor vessel is a low volume reactor cavity that insulates the reactor with fire bricks and thick concrete walls. A refractory reactor liner system provides water cooling to reduce the concrete wall temperatures. Example calculations are performed to show the plant response and MELCOR capabilities to characterize a range of accident conditions. The accidents selected for evaluation consider a range of degraded and failed modes of operation for key safety functions providing reactivity control, the primary system decay heat removal and also a piping leak of the line to the coolant drain tank.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Direct Observation of Two-Step, Stratified Crystallization and Morphology in Conjugated Polymer Thin Films

A two-step stratified crystallization process has been directly observed during cooling of poly(3-hexylthiophene) (P3HT) thin films of thickness h = 20-250 nm: a thin (<20 nm) layer at the free surface crystallizes ~25 °C higher than the bulk crystallization temperature (T C,bulk ), whereas the rest of the film (i.e. the underlayer) crystallizes near T C,bulk . In-situ measurements of films with and without a free surface unequivocally ascribe the high-temperature crystallization to a surface-induced process, which correlates with the formation of large birefringent structures and highly oriented edge-on crystallites at the air–polymer interface. In contrast, crystallization of the bulk-like underlayer leads to mostly edge-on-oriented crystallites in thinner films and becomes increasingly isotropic in thicker films. For h < 20 nm, free-surface effects dominate and only high-temperature crystallization is observed. These results highlight the potential of melt crystallization to tailor morphology and orientation across thin film thickness for specific electronic applications.

36 MATERIALS SCIENCE↗

Expansion-driven Weibel instability in magnetohydrodynamics: Linear theory for static systems

The Weibel dispersion relation is obtained in the magnetohydrodynamic (MHD) approximation by including a tensor expression for temperature. MHD gives an upper cutoff wavenumber for Weibel growth identical to kinetic theory if the electron drift velocity is included in the evolution of the electron temperature. MHD overestimates growth rates compared to kinetic theory and gives maximum growth at larger wavenumbers, but it only leads to divergent results as temperature anisotropy tends to infinity. Thermal conduction in MHD lowers the growth rates and shifts maximum growth to smaller wavenumbers, but flux-limited or nonlocal thermal conduction is found to significantly limit these effects. The results are used as a first step in evaluating the potential of MHD to simulate expansion-driven Weibel instability, which occurs due to the temperature tensor only cooling in the direction of expansion. Finally, the small temperature anisotropy found in expansion-driven Weibel instability means that MHD could be an adequate model because growth rates are much less than the electron plasma frequency, and wavelengths are much greater than the Debye length.

Davies, J. R. [Univ. of Rochester, NY (United Stat↗