Search NASA⌕ Search

SEARCH · Search NASA

Results for “distortion correction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Computer correction of an image distorted by turbulent atmosphere

The method for computer correction of images distorted by turbulent atmosphere is realised by means of the simplest optical system comprising a telescope and digital TV-camera. Real-time images with the diffraction resolution are obtained at ground paths of length up to 1800 m.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tidally distorted exoplanets: Density corrections for short-period hot-Jupiters based solely on observable parameters

The close proximity of short-period hot-Jupiters to their parent star means they are subject to extreme tidal forces. This has a profound effect on their structure and, as a result, density measurements that assume that the planet is spherical can be incorrect. We have simulated the tidally distorted surface for 34 known short-period hot-Jupiters, assuming surfaces of constant gravitational equipotential for the planet, and the resulting densities have been calculated based only on observed parameters of the exoplanet systems. Comparing these results to the density values, assuming the planets are spherical, shows that there is an appreciable change in the measured density for planets with very short periods (typically less than two days). For one of the shortest-period systems, WASP-19b, we determine a decrease in bulk density of 12% from the spherical case and, for the majority of systems in this study, this value is in the range of 1%-5%. On the other hand, we also find cases where the distortion is negligible (relative to the measurement errors on the planetary parameters) even in the cases of some very short period systems, depending on the mass ratio and planetary radius. For high-density gas planets requiring apparently anomalously large core masses, density corrections due to tidal deformation could become important for the shortest-period systems.

79 ASTRONOMY AND ASTROPHYSICS↗

Correcting nonlinear drift distortion of scanning probe and scanning transmission electron microscopies from image pairs with orthogonal scan directions

Unwanted motion of the probe with respect to the sample is a ubiquitous problem in scanning probe and scanning transmission electron microscopies, causing both linear and nonlinear artifacts in experimental images. We have designed a procedure to correct these artifacts by using orthogonal scan pairs to align each measurement line-by-line along the slow scan direction, by fitting contrast variation along the lines. We demonstrate the accuracy of our algorithm on both synthetic and experimental data and provide an implementation of our method.

36 MATERIALS SCIENCE↗

Correction of atmospheric distortion with an image-sharpening telescope

A 30 x 5 cm aperture telescope employing six movable mirrors to compensate for atmospherically induced phase distortion is built and tested. A feedback system adjusts the mirrors in real time to maximize the intensity of light passing through a narrow slit in the image plane. Essentially diffraction-limited performance is achieved when imaging both laser and white-light objects through 250 m of turbulent atmosphere. The behavior of the telescope is accurately predicted by computer simulations. The system has yet to achieve its full potential, but has already operated successfully for objects as dim as 5th magnitude.

Buffington, A.↗

Correction of instrumental distortion by analytical deconvolution of data

A general analytical theorem developed by van de Hulst (1946) for inverting the convolution integral is reviewed and illustrated both with synthetic data and with experimental data from time-of-flight measurements. If the undesired influence of an instrument used in an experimental measurement can be represented by the convolution integral, the original undistorted or true distribution may sometimes be recovered in postprocessing the data by means of deconvolution. Analytical deconvolution is achieved by using the coefficients from a power series representation of the distorted output distribution and a set of 'solving polynomials' which may be readily derived from the response function of the instrument.

Morton, D. C.↗

Corrections to fringe distortion due to flow density gradients in optical interferometry

An analytical method is formulated to account for distortions of optical interferograms used for studies of flow over airfoils experiencing dynamic stall. It is shown that such distortions are generated primarily due to optical path deflections in the test flow, caused by large density gradients. Such in-flow optical path deflections are neglected in conventional optical techniques for flow studies. The present method employs a ray analysis to determine these in-flow optical path deflections, and accurately predicts the interferogram distortions.

Cho, Y. C.↗

Anti-distortion bioinspired camera with an inhomogeneous photo-pixel array

The bioinspired camera, comprising a single lens and a curved image sensor—a photodiode array on a curved surface—, was born of flexible electronics. Its economical build lends itself well to space-constrained machine vision applications. The curved sensor, much akin to the retina, helps image focusing, but the curvature also creates a problem of image distortion, which can undermine machine vision tasks such as object recognition. Here we report an anti-distortion single-lens camera, where 4096 silicon photodiodes arrayed on a curved surface in a nonuniform pattern assimilated to the distorting optics are the key to anti-distortion engineering. That is, the photo-pixel distribution pattern itself is warped in the same manner as images are warped, which correctively reverses distortion. Acquired images feature no appreciable distortion across a 120° horizontal view, as confirmed by their neural-network recognition accuracies. This distortion correction via photo-pixel array reconfiguration is a form of in-sensor computing.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Improved measurement method for electron energy distribution functions with high accuracy and reliability

An improved ac superimposed method for measuring the electron energy distribution function (EEDF) with high accuracy is proposed. Although high amplitude of the superimposed ac voltage provides a higher signal-to-noise ratio (SNR), it causes the distortion in the EEDF. To correct the distortion, we used two different EEDFs measured by applying two different amplitudes. The distortion was accurately corrected over the entire electron energy region, and the corrected EEDF had the better SNR. The reliability of the corrected EEDF was proved by comparing the effective electron temperatures obtained from the measured EEDFs, and as a result, the corrected EEDF was very reliable.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Far Ultraviolet Imaging from the Image Spacecraft

Direct imaging of the magnetosphere by the IMAGE spacecraft will be supplemented by observation of the global aurora. The IMAGE satellite instrument complement includes three Far Ultraviolet (FUV) instruments. The Wideband Imaging Camera (WIC) will provide broad band ultraviolet images of the aurora for maximum spatial and temporal resolution by imaging the LBH N2 bands of the aurora. The Spectrographic Imager (SI), a novel form of monochromatic imager, will image the aurora, filtered by wavelength. The proton-induced component of the aurora will be imaged separately by measuring the Doppler-shifted Lyman-a. Finally, the GEO instrument will observe the distribution of the geocoronal emission to obtain the neutral background density source for charge exchange in the magnetosphere. The FUV instrument complement looks radially outward from the rotating IMAGE satellite and, therefore, it spends only a short time observing the aurora and the Earth during each spin. To maximize photon collection efficiency and use efficiently the short time available for exposures the FUV auroral imagers WIC and SI both have wide fields of view and take data continuously as the auroral region proceeds through the field of view. To minimize data volume, the set of multiple images are electronically co-added by suitably shifting each image to compensate for the spacecraft rotation. In order to minimize resolution loss, the images have to be distort ion-corrected in real time. The distortion correction is accomplished using high speed look up tables that are pre-generated by least square fitting to polynomial functions by the on-orbit processor. The instruments were calibrated individually while on stationary platforms, mostly in vacuum chambers. Extensive ground-based testing was performed with visible and near UV simulators mounted on a rotating platform to emulate their performance on a rotating spacecraft.

Mende, S. B.↗

Corrections for the geometric distortion of the tube detectors on SANS instruments at ORNL

Small-angle neutron scattering instruments at the Oak Ridge National Laboratory's High Flux Isotope Reactor were upgraded in area detectors from the large, single volume crossed-wire detectors originally installed to staggered arrays of linear position-sensitive detectors (LPSDs). The specific geometry of the LPSD array requires that approaches to data reduction traditionally employed be modified. Here, two methods for correcting the geometric distortion produced by the LPSD array are presented and compared. The first method applies a correction derived from a detector sensitivity measurement performed using the same configuration as the samples are measured. In the second method, a solid angle correction is derived that can be applied to data collected in any instrument configuration during the data reduction process in conjunction with a detector sensitivity measurement collected at a sufficiently long camera length where the geometric distortions are negligible. Furthermore, both methods produce consistent results and yield a maximum deviation of corrected data from isotropic scattering samples of less than 5% for scattering angles up to a maximum of 35°. The results are broadly applicable to any SANS instrument employing LPSD array detectors, which will be increasingly common as instruments having higher incident flux are constructed at various neutron scattering facilities around the world.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Peculiarities of adaptive phase correction of optical wave distortions under conditions of ‘strong’ intensity fluctuations

The reason for the loss of efficiency of adaptive phase correction in the propagation of optical waves in a turbulent atmosphere under conditions of ‘strong’ intensity fluctuations is experimentally explained for the first time. Based on the data from experiments conducted on both horizontal and vertical atmospheric paths, we have found that intensity fluctuations begin to significantly affect phase measurements when the coherence radius of the optical wave becomes less than the radius of the first Fresnel zone. Under these conditions, the main meter of adaptive optics systems, i. e. the Hartmann sensor, no longer provides correct measurements of the phase distribution in the presence of deep amplitude modulation. Based on the study of the behaviour of the mode components of the phase fluctuations reconstructed from the results of measurements in various operating regimes, we have found that, first of all, the amplitudes of the lowest modes of phase fluctuation expansion (tilts, defocusing, and astigmatism) are distorted, which, as the analysis shows, is very different from the regime of weak fluctuations. (atmospheric optics)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Close-range photogrammetry with video cameras

Examples of photogrammetric measurements made with video cameras uncorrected for electronic and optical lens distortions are presented. The measurement and correction of electronic distortions of video cameras using both bilinear and polynomial interpolation are discussed. Examples showing the relative stability of electronic distortions over long periods of time are presented. Having corrected for electronic distortion, the data are further corrected for lens distortion using the plumb line method. Examples of close-range photogrammetric data taken with video cameras corrected for both electronic and optical lens distortion are presented.

Burner, A. W.↗

Close-Range Photogrammetry with Video Cameras

Examples of photogrammetric measurements made with video cameras uncorrected for electronic and optical lens distortions are presented. The measurement and correction of electronic distortions of video cameras using both bilinear and polynomial interpolation are discussed. Examples showing the relative stability of electronic distortions over long periods of time are presented. Having corrected for electronic distortion, the data are further corrected for lens distortion using the plumb line method. Examples of close-range photogrammetric data taken with video cameras corrected for both electronic and optical lens distortion are presented.

Burner, A. W.↗

Integrators

Many electromagnetic measurements detect signals that are the time derivative of the actual quantity of interest. Examples include so-called “B-dot” and “D-dot” detectors that are used for measuring transient magnetic and electric fields. Integration of these signals to recover the quantity of interest is performed either by hardware integrators in the signal line, or by software coding in the analysis programming. Hardware integration is usually done using a classic resistive-capacitive (RC) circuit, or internally in the detector by induction (L/R) or stray capacitance (RC). These hardware integration methods are only approximate, and must be corrected for distortion. This is usually called “droop correction.” In this note, we will examine this correction in some detail. Transient analysis via Laplace transforms will be used to simplify the mathematics. A rudimentary understanding of this method is assumed.

42 ENGINEERING↗

Guide to the use of Mariner images

Planetary imaging from unmanned spacecraft, almost exclusively done by digital systems, is examined. The Mars Mariner 9 television camera, representative of such systems, is considered. Each image consists of 700 lines, each containing 832 picture elements, or pixels. Each pixel contains nine binary bits of information capable of displaying 512 discrete brightness levels. Several problems inherent in television systems are discussed. These include nonuniform target response, residual images, noise, and blemishes. These defects can be removed to some extent by decalibration of the image. The final product is geometrically corrected for camera distortion and photometrically corrected. Several versions of the decalibrated images are available. The most generally useful are the geometrically corrected images with enhanced contrast. The Mariner 10 imaging of Mercury is briefly discussed.

Saunders, R. S.↗

Programmable Remapper

Input image remapped rapidly and accurately onto different coordinate grid. Analog/digital electronic image-processing system developed to warp input images onto arbitrary coordinate grids at video rates. Advantages of system include antialiasing effect of many-to-one data path and speed of lookup-table operation. Lookup tables reprogrammed easily with help of computer that generates table values from mathematical description of desired transformation. Applications include real-time corrections of distortions in input optics of image sensors, corrections for repeatable nonlinear scanning, and aiding persons of impaired vision by deliberately distorting images onto remaining functional portions of retinas.

Juday, Richard D.↗