Search NASA⌕ Search

SEARCH · Search NASA

Results for “distributed power”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Electric Utility Distribution Costs: Scoping Study on Trends, Drivers, and Possible Response Strategies [Slides]

This scoping study synthesizes information that will help stakeholders understand the scope, scale, and drivers of recent increases in investor-owned utility (IOU) expenditures on local distribution power grids, while providing regulators and other decision-makers with potential strategies to keep electricity bills down. The study includes five distinct components. Drawing first on data from FERC Form 1, it summarizes key trends in past and recent IOU distribution costs. Next, through a review of a sample of distribution-system plans, it characterizes material drivers of planned distribution expenditures. Ultimately, regulators must approve cost recovery for IOU expenditures, including those for the distribution system. The study therefore also: examines trends in utility requests and regulatory approvals related to changes in retail rates and return on equity; identifies areas where utility shareholder and customer incentives may be misaligned; and develops a menu of options that state regulators might consider to optimize distribution system expenditures. Some of the key findings include: - IOU distribution spending at a national level has grown by 6%/yr since 2014 in real dollar terms, 4x faster than in the prior 20 years and consisting mostly of capital (not operating) expenditure. - On a per-kWh basis, increases in IOU distribution costs since 2014 represent over 30% of the overall national-average increase in retail electricity rates. - Regional spending growth has ranged from 2-8%/yr, with larger estimated rate impacts in CAISO, then NYISO & ISO-NE, and then the Southeast, MISO & PJM (see figure). - Some utilities are planning for significantly increased distribution system spending. Planned spending on managing the existing system (asset replacement, safety & reliability, and resilience are all important drivers) exceeds that for capacity expansion. - IOU rate increase requests ($18 billion in 2025) and public utility commission (PUC) approval levels (average of 64% of requested amounts from 2021-2025) have recently hit multi-decadal highs. - PUCs in New England and the Southeast have recently approved a greater fraction of rate requests (>75%, on average) than in ther regions, while PUCs in California and the Southeast have generally authorized higher equity returns than in other regions. - Regulators have many tools to tackle potential misalignments between utility and customer interests and, more specifically, to optimize and reduce distribution costs. Shorter-term options include those related to return on equity, capital structure, depreciation, trackers, construction work in progress, and securitization. Longer-term options include performance-based regulation and a wide variety of planning-related requirements. All options embed important tradeoffs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Modeling Communication Infrastructures of Cyber Physical Systems

This effort explores modeling cyber infrastructure, including communication devices like switches, routers, sensors, and controllers, and physical media attributes like propagation of radio signals, in coordination with power distribution system model layouts. To do this, the project studies real-world configurations to define axioms of how different communication media is deployed with control equipment. These axioms will be used to develop tools to generate realistic cyber infrastructure models from starting power system models. This effort leverages and builds on the co-simulation platform developed by the other RD2C projects. The axioms and tools will be validated and demonstrated with the NS3 simulation tool as part of a co-simulation to show the behavior/impacts of cyber infrastructure on control operations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Enhancing Power Resilience for Remote Communities: A Comprehensive Renewable Energy Solution for Itbayat Island

The island of Itbayat, Philippines, faces significant challenges in maintaining a reliable and resilient power supply due to its current reliance on a vulnerable power distribution system managed by a local electric cooperative. The existing infrastructure, which includes diesel generators and a radial network configuration with some above-ground lines, is highly susceptible to frequent typhoons and adverse weather conditions. These factors, combined with inadequate staffing and high operational costs, result in frequent power outages that disrupt daily life and hinder economic development. This white paper proposes a comprehensive solution to enhance the resilience and reliability of Itbayat's power system by integrating renewable energy sources, specifically solar photovoltaic (PV) systems, battery storage, and a microgrid controller. The proposed solution aims to reduce dependency on diesel fuel, optimize energy use, and provide a sustainable and robust power supply for the island. Key components of the solution include: 1. Solar PV Installation: Deploying solar PV panels to harness abundant solar energy, reducing reliance on diesel fuel. 2. Battery Storage Systems: Installing battery storage to store excess solar energy and ensure a continuous power supply during low solar generation periods. 3. Microgrid Controller: Implementing a microgrid controller to manage and optimize the integration of solar PV, battery storage, and existing diesel generators. The proposed solution addresses several critical issues, including system vulnerability, generator dependency, and operational inefficiencies. By adopting this innovative approach, Itbayat Island can achieve a more resilient, efficient, and sustainable energy infrastructure, ensuring a stable power supply for its residents and enhancing overall energy security.

14 SOLAR ENERGY↗

Data Centers and Digital Assurance Workshop 3 – Mitigations for Digital Assurance Risks

The third session of the TADA (Technical Assistance for Digital Assurance) Data Centers Cohort, held on November 18, 2025, focused on developing mitigation strategies for digital assurance risks identified in previous workshops. Hosted by Idaho National Laboratory (INL) and ScottMadden, the session emphasized the application of Cyber-Informed Engineering (CIE) to data center infrastructure, particularly at the utility–data center interface. Participants revisited and ranked key digital assurance risks, including architecture and interface weaknesses, governance gaps, and AI-enabled threats. The workshop introduced the 12 principles of CIE, advocating for consequence-focused design, engineered controls, and secure information architecture to proactively reduce cyber-physical vulnerabilities. These principles were applied to critical data center systems such as power distribution, UPS, cooling, SCADA/BMS, and grid-forming batteries. The session also addressed governance challenges at the interconnection boundary, highlighting the need for clear roles in telemetry sharing, firmware management, and trip settings. Special attention was given to emerging risks from behind-the-meter (BTM) generation, including reverse-power flow and the integration of small modular reactors (SMRs), which shift data centers from large loads to complex generation nodes. Participants explored how interconnection agreements can serve as enforceable instruments for digital assurance, and reviewed gaps in current standards such as NERC CIP, IEC 62443, and IEEE 1547. The workshop concluded with pathways to standardization, including model agreement language, state-level programs, and expanded NERC guidance. INL also presented tools and frameworks for secure procurement and supplier risk management, reinforcing the need for integrated engineering and policy solutions to secure the evolving data center–grid ecosystem. Session 3 of 3.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Intercell Power Transformer for Power Balancing of Polyphase Wireless Power Transfer Systems

Polyphase wireless power transfer (PWPT) systems experience receiver side imbalances in misaligned conditions. This paper proposes a method for power balancing in PWPT systems, specifically addressing the challenges caused by receivers coil unequal coupling. An intercell power transformer (IPT) is introduced at the receiver side to mitigate the effects of coil mismatch. Simulations of the PWPT system incorporating IPT demonstrate its effectiveness in enhancing power distribution. For voltage-fed rectifiers (VFR), the IPT increases the conduction angle, resulting in higher output power. In current- fed rectifiers (CFR), the IPT promotes uniform power sharing among rectifiers, thereby reducing electrical stress on semiconductor devices and passive components. Simulation results indicate that, under coil misalignment, the IPT improves output power by approximately 49% for VFRs and 44% for CFRs compared to conventional PWPT systems without IPT.

Wojda, Rafal [ORNL] (ORCID:0000000286609268)↗

Grid Topology Discovery Algorithm Evaluation of Suitability for Utility Deployment (CRADA 606 Final Report)

This work presents the results of a field-informed demonstration aimed at evaluating the practical suitability of a topology discovery algorithm for utility environments. We demonstrated an algorithm that uses a graph-theory-informed state estimation approach for model selection. In collaboration with Survalent and Peninsula Light Co., the algorithm was applied to real feeder models and field measurements from supervisory control and data acquisition (SCADA) and advanced metering infrastructure (AMI) systems to identify the operational topology of a power distribution system. The demonstration assessed the algorithm’s performance under realistic data conditions, including sparse and noisy measurements, and examined its ability to identify the most likely network configurations. The results confirmed that the approach can effectively narrow down feasible topologies, providing operators with improved situational awareness of network status. Key lessons learned emphasize the need for systematic data validation and strategic sensor placement to enhance observability. These insights inform future deployment strategies and guide refinements for broader adoption in utility operations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Demonstrating the data center as a flexible grid asset using a C-HIL setup

Increasing data center demand is outpacing grid infrastructure development. Artificial intelligence workloads and hyperscale cloud growth are creating unprecedented demand for power, while traditional grid expansion faces multiyear development timelines. Verrus is developing an innovative datacenter solution for this challenge, data centers that act as active grid-supportive assets rather than passive loads. Our approach integrates a novel grid-aware power flow management system with battery energy storage systems(BESS) into a microgrid-controlled, medium-voltage power distribution architecture that delivers critical capabilities, such as: * Fast response to grid disturbances such over/ under voltage or over/ under frequency * Demand flexibility that can service requests from the utility within 10 s * Uninterrupted transition to islanded operation during grid outages * Continuous uptime assurance for compute loads while maintaining all customer service level agreements. Through Verrus' strategic partnership with the National Renewable Energy Laboratory (NREL), these capabilities were validated using NREL's Advanced Research on Integrated Energy Systems (ARIES) virtual emulation environment to model a 70-MW grid-interactive data center. This paper outlines the design, methodology, and results of this emulated deployment, demonstrating that data centers can provide both critical load resilience and ancillary grid support without compromising uptime requirements. Specifically, we present a digital real time simulation of a 70 MW data center integrated with a physical microgrid controller, and demonstrate the data center response in the event of a grid voltage and frequency event, utility demand response request and utility outage.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Adaptive Online Model Update Algorithm for Predictive Control in Networked Systems

In this article, we introduce an adaptive on-line model update algorithm designed for predictive control applications in networked systems, particularly focusing on power distribution systems. Unlike traditional methods that depend on historical data for offline model identification, our approach utilizes real-time data for continuous model updates. This method integrates seamlessly with existing online control and optimization algorithms and provides timely updates in response to real-time changes. This methodology offers significant advantages, including a reduction in the communication network bandwidth requirements by minimizing the data exchanged at each iteration and enabling the model to adapt after disturbances. Furthermore, our algorithm is tailored for non-linear convex models, enhancing its applicability to practical scenarios. The efficacy of the proposed method is validated through a numerical study, demonstrating improved control performance using a synthetic IEEE test case.

data-driven model predictive control↗

Data-Driven Voltage Regulation of Distribution Grid Using Nonlinear Autoregressive Model with Exogenous Inputs (NARX)

This article proposes data-driven control via a nonlinear autoregressive model with exogenous inputs (NARX) for real-time voltage regulation of a modified feeder using reactive power sources. Traditional voltage control strategies rely on rule-based heuristics or optimization techniques, which often require detailed system models and extensive computational resources. The NARX-based controller learns system dynamics from historical data and predicts optimal reactive power dispatch in real-time for voltage correction. The proposed approach is evaluated on a power system feeder model under varying load and network conditions. Simulation results demonstrate that the NARX-based controller achieves improved voltage regulation, offering higher adaptability to system fluctuations. This study highlights the potential of data-driven control for enhancing the reliability of power distribution networks.

Donge, Vrushabh [ORNL] (ORCID:0000000306062803)↗

The infrared imaging video bolometer at Wendelstein 7-X

The radiated power distribution is a crucial aspect of heat transport, heat load mitigation, and plasma exhaust performance. An imaging video bolometer camera has been installed to measure the plasma radiated power in the divertor region of the Wendelstein 7-X (W7-X) stellarator. This diagnostic offers a wide-angle (40° × 68°) sampling of the plasma volume in both the poloidal and toroidal directions. The field-of-view is covered with a large number (> 500) of bolometer channels, providing imaging capability. The diagnostic design is introduced here together with its data analysis procedure. A set of laboratory experiments is performed to assess the thermal properties of the gold absorber foil and their spatial uniformity. Following installation, a heat source originating from the inertially cooled front of the diagnostic is identified and filtered out. The discharge data indicate a satisfactory signal-to-noise ratio as well as spatiotemporal resolution. These represent the first toroidally resolved images of the line-integrated radiated power in the W7-X island divertor. The diagnostic was then upgraded with a thinner platinum absorber and adjusted mirrors. Early data from the most recent experimental campaign employing the upgraded design show a considerable improvement in the diagnostic performance with more bolometer channels (> 1400), extended coverage, and increased spatial resolution.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

EVI-EnSitePy (Electric Vehicle Infrastructure – Energy Estimation and Site Optimization Tool in Python) [EVI-X Modeling Suite] [SWR-25-07]

EVI-EnSitePy is a comprehensive agent-based tool designed for the analysis and design of high-power charging sites, encompassing a wide array of site agents including Electric Vehicles (EVs), chargers, energy storage units (ESS), renewable energy resources (DER), and loads. This versatile tool offers diverse functionalities and a modular modeling approach, allowing detailed configuration of agents based on power ratings, port numbers, energy capacities, demand requirements, charger interfaces, and flexibility to customize the tool for project specific goals. By simulating agent interactions and employing various metrics, EVI-EnSitePy enables the assessment of site performance, exploration of energy management systems (EMS), and implementation of innovative EV charging policies. Utilizing EV charge schedules and arrival states, the tool performs thorough charging site simulations, with outputs consisting of agent and site-level power profiles and statistical metrics. Employing a tree graph structure, EVI-EnSitePy supports nested site structures and power distribution modeling. The tool's ability to generate charging schedules deterministically or via stochastic analysis further enhances its versatility. Through its features and capabilities, EVI-EnSitePy offers a powerful platform for informed decision-making in the realm of high-power charging site design and operation.

Jackson, Derek [National Renewable Energy Laborato↗

Scale effects on core design, fuel costs, and spent fuel volume of pressurized water reactors

The desire to improve the economic competitiveness and deployment pace of nuclear energy through modularization, manufacturing, and series production had led to the development of smaller size reactors. As the standard 17x17 fuel technology is mainly maintained in the pressurized water reactors (PWRs) category, this translates into a lower number of fuel assemblies in the core and sometimes a reduced fuel height. To assess the impact of such scale change in core design on fuel cycle cost and spent fuel volume, a scoping analysis tool is developed based on infinite lattice calculations, leakage, fuel management reduced models, and levelized unit cost of electricity (LCOE) estimate. As such, cost dynamics driven by fuel specific power, burnup, core leakage, feed, cycle length, fuel assembly height as well as uranium market data are captured with consistent set of assumptions and analysis methods. A selection of 5 reactor designs representative of leading PWR developers is assessed and compared. Pursuing higher specific powers and optimal burnups are highlighted as the main fuel cost reduction drivers, nevertheless, practical limitations and opportunities must be evaluated to establish the feasibility of such enhanced fuel operation. In consequence, a detailed core design is performed using SIMULATE3 code for 5 PWR variations including natural and forced coolant circulation modes, two reactor scales, power densities of 73, 112, and 123 kW/l and higher discharge burnups. Design and optimization are performed at the lattice level, for the reflector, and at the core loading level. Satisfactory steady-state operation including power distribution, coolant operating limits, and reactivity requirements are analyzed and reported in this paper. The fuel economics of the detailed core designs confirm the scoping analysis findings. Despite the unlocked power uprates in small PWRs, the achievable burnup for a given fuel specific power requires more enrichment and shorter fuel height results in higher fabrication costs per mass of fuel, which makes scaling down core size a more expensive endeavor on the fuel cycle front. Spent fuel volumes are reported for the PWRs designed in this paper. Furthermore, these volumes are driven by the core average discharge burnup regardless of the scale in consideration. Additional cost and core performance aspects related to heavy reflector gains, fuel-reflector substitution, and disposal cost policy in the U.S. are examined.

42 ENGINEERING↗

User Manual for the Thermal Hydraulic Code SE2RCT

SE2-ANL is a modified version of SUPERENERGY-2 which interfaces the power distribution in the ANL maintained physics codes for the user. SE2RCT is a special version of SE2-ANL developed for specific use on models of the Experimental Breeder Reactor-II (EBR-II). SE2RCT fulfills a specific role in the calculated results as part of the Fuels Irradiation and Physics Database (FIPD) and is built to connect with the Physics and Analysis DataBase (PADB) for metallic fuel research and development in advanced sodium-cooled fast reactors (SFRs) created for EBR-II. SE2RCT is primarily a thermal analysis code that interfaces with the RCT based pin power details instead of the built-in pin power dehomogenization strategy in SE2-ANL. Beyond the thermal hydraulic calculation, the SE2RCT code provides detailed axial distributions of the RCT calculated results. SE2RCT also calculates the the axial distribution of pin wise DPA for the cladding materials which is part of the FIPD calculated results. This report serves as the user manual for SE2RCT and thus eliminates the QA gap of missing documentation on the SE2RCT software. All of the features and limitations of SE2RCT are documented in this report. The input and output specifications of SE2RCT are discussed in detail, and some unique features of SE2RCT, e.g. accurate pin power and temperature results for problems with non-uniform composition within an assembly, are also demonstrated and tested.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

ANS Winter 2024 Summary: Optimizing the ATF-2Ramp Power Profile

When the Halden Boiling Water Reactor closed down in 2018, a need to restore the capability for in-reactor power ramp testing arose. Such testing is valuable for studying pellet-clad interaction phenomena in nuclear fuels. The data from these studies is of great interest to a number of research programs, including the accident-tolerant fuel (ATF) program at Idaho National Laboratory (INL). In 2022, Woolstenhulme et al. proposed several power ramp testing ideas using facilities at INL, including irradiation in the Transient Reactor Test Facility (better known as TREAT) and the Advanced Test Reactor (ATR) [1]. Worrall et al. [2] and Labossiere-Hickman et al. [3] subsequently performed feasibility studies for the ATR testing options in 2023. This summary further investigates the three-pin trefoil design (Fig. 1) for the proposed ATF-2Ramp Experiment discussed in Labossiere-Hickman et al. [3]. ATF-2Ramp is designed to operate in the center flux trap (CFT) of the ATR during a powered axial locator mechanism (PALM) cycle: a short, variable-powered cycle with an asymmetric power distribution. Previously, it was shown that tailoring the thickness of the hafnium (Hf) neutron shields (“mini-shrouds”) surrounding each pin offered a degree of control sufficient to achieve the programmatic linear heat generation rate (LHGR) targets for ATF-2Ramp during the high-power period of a PALM cycle. New work involves shortening the experiment test train for consistency with the fuel pins in ATF-2D [4] and then shaping the axial power profile of the three test pins.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Accelerated Fuel Qualification of Fast Modular Reactor Fuel in a Thermal Reactor: Modeling and Simulation Paired with Irradiation Testing

The accelerated fuel qualification (AFQ) methodology is applied by simulating accelerated fuel tests of the General Atomics Electromagnetic Systems’ fuel system for its 44-MW(electric) gas-cooled, fast-spectrum fast modular reactor (FMR). This fuel is comprised of UO 2 pellets in SiGA® cladding, a silicon carbide ceramic matrix composite. Fast reactors, like the FMR, offer many benefits, including high fuel utilization and flexibility, but may require a lengthy material design process if tests are performed using fast neutron irradiation alone. A thermal neutron irradiation can instead be used to rapidly test how well key components of the current material models extend to high burnup. Thermal neutrons produce a different radial power distribution within the pin than fast neutrons. However, the temperature and burnup values for the two neutron types are comparable, and the differences between the simulated fuel responses are relatively small, demonstrating the weak sensitivity of the physics-based fuel model calculations on the neutron type and the irradiation rate. Furthermore, the deformation of the SiGA cladding saturates after about 1 displacement per atom for both neutron spectra. In an accelerated fuel test, the irradiation time required to reach the target fuel burnup can be reduced by a factor of 3 by using a small rodlet with a 45% smaller pellet diameter while maintaining the same linear power. Therefore, the time for data collection up to high burnup can be significantly reduced while maintaining the same temperature profile, which largely determines the material response. Tests of fuel rodlets of standard and compact size will be carried out in the Idaho National Laboratory’s Advanced Test Reactor (ATR), including full size and compact rodlets with varying gap sizes. By applying physics-based mechanistic modeling and simulation in accordance with the AFQ methodology, this type of compact rodlet testing in a thermal test reactor captures the necessary phenomena to test fuel material models up to high burnup and to simulate the expected impact of fast neutron radiation on the fuel in FMR operations. Finally, this approach to testing fast reactor fuels in existing thermal test reactors, paired with advanced physics-based mechanistic modeling and simulation, is expected to be applicable to a range of advanced fuels and will decrease the overall fuel qualification timeframe from decades to years.

Advanced test reactor (ATR)↗

Multi-cycle reload analysis of a long cycle gas-cooled fast modular reactor

There is currently significant interest in deploying HALEU-fueled fast reactors, including the General Atomics (GA) Fast Modular Reactor (FMR). Such reactors can achieve very long fuel cycles, but with multi-batch loading will take decades to reach equilibrium. This motivates design and analysis of both the initial core and multi-cycle reload, which is typically performed using fast-running, deterministic fast reactor codes such as the Argonne Reactor Computation (ARC) codes. In this paper, multicycle reload of the GA FMR is analyzed using the ARC codes. The GA FMR utilizes 19.75 % enriched fuel in a 16 year cycle with a three-batch strategy, with twice-burned fuel placed on the core periphery. The GA FMR has a softened neutron spectrum due to reflecting elements in the core, so the neutronic solution is first benchmarked against the OpenMC Monte Carlo code. Discrepancy on k eff is 400–600 pcm, likely due to the softened neutron spectrum, heterogeneous fuel assembly design and central reflector. However, the rms discrepancy on the assembly power distribution is only 0.6 %, despite the presence of the central reflector. A reload strategy is devised for the first three cycles of such a reactor, ultimately spanning the first 45–48 years of its operation. The fresh core uses 19.75 %, 19.25 % and 16.75 % enriched fuel in place of fresh, once-burned and twice-burned and is then subsequently refueled with only 19.75 % enriched fuel. The cycle length is varied over 3 cycles of operation to balance fuel utilization and reactor availability, specifically with use of an extended 18-year Cycle 1, followed by a shortened 11-year Cycle 2. Cycle 3 is close to the target 16-year length. Finally, placing twice burned assemblies next to the GA FMR central reflector can reduce power peaking by 3 %, at the expense of slightly reducing the cycle length.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A317_Fast and Thermal Neutron Spectrum Dosimetry Measurements in the Advanced Test Reactor large-B and small-I Positions Following the Sixth Core Internals Change-out

The Advanced Test Reactor (ATR) has a wide variety of irradiation positions that have had experiments that were developed by users from around the world. Most experiment irradiations rely on thoroughly benchmarked numerical models. However, some irradiation positions in ATR are not as well- characterized and are complicated by spectral perturbations from control cylinder orientation. The “small I” and “large-B” irradiation positions are located nearby control cylinders and suffer from these flux perturbations from control cylinder orientations that change during an irradiation cycle to maintain the desired core power distribution. Models predicted that these types of position would exhibit both spectral shifts and amplitude changes in neutron flux, but few measurements have been conducted to benchmark these predictions. Recently, requalification testing was performed to confirm the operational readiness of the ATR following the completion of the Core Internals Change-out (CIC). These tests provided a unique opportunity to validate the analytical methods used to simulate the ATR because nearly all components in the reactor were in a clean as-built state, significantly reducing modelling uncertainties. One subset of the testing included characterization of the fast and thermal neutron flux in the “small-I” and “large-B” positions using silver, cobalt, and nickel neutron dosimetry. In contrast to typical irradiation cycles, the control cylinders were held in position during the post-CIC nuclear testing. The specific activity of these dosimeter wires was measured following two low-power tests with different control cylinder positions.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Community-Engaged Energy Transition Planning in Holyoke

The overarching motivation of this project is to provide stakeholder-engaged research and education to enable a clean, equitable, and resilient energy transition. Presently, low-income communities and people of color are disproportionately burdened by environmental harm, while also being routinely left out of planning processes and benefits from infrastructure improvements. The Energy Transition Institute (ETI) addresses these issues in three ways: community engagement, educating diverse future leaders, and cutting-edge research. As municipalities across the Commonwealth plan their transition to a climate-friendly energy system, research from ETI will advance technical and social understanding of heating electrification, energy storage, demand flexibility, reliability and resiliency of power distribution infrastructure, with attention to equity. This will benefit surrounding communities, cities and towns across Massachusetts, and the global research community

14 SOLAR ENERGY↗